Luca Canalini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Luca Canalini has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Dorothea Miller
Department of Neurosurgery, University Hospital Knappschaftskrankenhaus, Bochum, Germany
4 shared publicationsJan Klein
Fraunhofer MEVIS, Institute for Digital Medicine
4 shared publicationsRon Kikinis
Surgical Planning Laboratory, Brigham and Women’s Hospital, Harvard Medical School, Boston, USA
4 shared publications- Jan Klein
Fraunhofer MEVIS, Bremen, Germany
3 shared publications Alessa Hering
Fraunhofer MEVIS, Institute for Digital Medicine
2 shared publicationsHorst K. Hahn
Fraunhofer MEVIS, Institute for Digital Medicine
2 shared publications
Latest Publications
- 18 July 2023
- Published by Springer Nature
- p. 262-272
Iterative Method to Register Longitudinal MRI Acquisitions in Neurosurgical Context
- 18 July 2023
- Published by Springer Nature
- p. 262-272
Iterative Method to Register Longitudinal MRI Acquisitions in Neurosurgical Context
- Open Access
- 5 November 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (3) , 1-9
MR-CT multi-atlas registration guided by fully automated brain structure segmentation with CNNs
Purpose: Computed tomography (CT) is widely used to identify anomalies in brain tissues because their localization is important for diagnosis and therapy planning. Due to the insufficient soft tissue contrast of CT, the division of the brain into anatomical meaningful regions is challenging and is commonly done with magnetic resonance imaging (MRI). Methods: We propose a multi-atlas registration approach to propagate anatomical information from a standard MRI brain atlas to CT scans. This translation will enable a detailed automated reporting of brain CT exams. We utilize masks of the lateral ventricles and the brain volume of CT images as adjuvant input to guide the registration process. Besides using manual annotations to test the registration in a first step, we then verify that convolutional neural networks (CNNs) are a reliable solution for automatically segmenting structures to enhance the registration process. Results: The registration method obtains mean Dice values of 0.92 and 0.99 in brain ventricles and parenchyma on 22 healthy test cases when using manually segmented structures as guidance. When guiding with automatically segmented structures, the mean Dice values are 0.87 and 0.98, respectively. Conclusion: Our registration approach is a fully automated solution to register MRI atlas images to CT scans and thus obtain detailed anatomical information. The proposed CNN segmentation method can be used to obtain masks of ventricles and brain volume which guide the registration.
- 5 November 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (3) , 1-9
Open AccessMR-CT multi-atlas registration guided by fully automated brain structure segmentation with CNNs
Purpose: Computed tomography (CT) is widely used to identify anomalies in brain tissues because their localization is important for diagnosis and therapy planning. Due to the insufficient soft tissue contrast of CT, the division of the brain into anatomical meaningful regions is challenging and is commonly done with magnetic resonance imaging (MRI). Methods: We propose a multi-atlas registration approach to propagate anatomical information from a standard MRI brain atlas to CT scans. This translation will enable a detailed automated reporting of brain CT exams. We utilize masks of the lateral ventricles and the brain volume of CT images as adjuvant input to guide the registration process. Besides using manual annotations to test the registration in a first step, we then verify that convolutional neural networks (CNNs) are a reliable solution for automatically segmenting structures to enhance the registration process. Results: The registration method obtains mean Dice values of 0.92 and 0.99 in brain ventricles and parenchyma on 22 healthy test cases when using manually segmented structures as guidance. When guiding with automatically segmented structures, the mean Dice values are 0.87 and 0.98, respectively. Conclusion: Our registration approach is a fully automated solution to register MRI atlas images to CT scans and thus obtain detailed anatomical information. The proposed CNN segmentation method can be used to obtain masks of ventricles and brain volume which guide the registration.
- Open Access
- 20 September 2022
- Published by Frontiers Media SA in Frontiers in Neuroimaging
- Vol. 1, 977491
Quantitative evaluation of the influence of multiple MRI sequences and of pathological tissues on the registration of longitudinal data acquired during brain tumor treatment
Registration methods facilitate the comparison of multiparametric magnetic resonance images acquired at different stages of brain tumor treatments. Image-based registration solutions are influenced by the sequences chosen to compute the distance measure, and the lack of image correspondences due to the resection cavities and pathological tissues. Nonetheless, an evaluation of the impact of these input parameters on the registration of longitudinal data is still missing. This work evaluates the influence of multiple sequences, namely T1-weighted (T1), T2-weighted (T2), contrast enhanced T1-weighted (T1-CE), and T2 Fluid Attenuated Inversion Recovery (FLAIR), and the exclusion of the pathological tissues on the non-rigid registration of pre- and post-operative images. We here investigate two types of registration methods, an iterative approach and a convolutional neural network solution based on a 3D U-Net. We employ two test sets to compute the mean target registration error (mTRE) based on corresponding landmarks. In the first set, markers are positioned exclusively in the surroundings of the pathology. The methods employing T1-CE achieves the lowest mTREs, with a improvement up to 0.8 mm for the iterative solution. The results are higher than the baseline when using the FLAIR sequence. When excluding the pathology, lower mTREs are observable for most of the methods. In the second test set, corresponding landmarks are located in the entire brain volumes. Both solutions employing T1-CE obtain the lowest mTREs, with a decrease up to 1.16 mm for the iterative method, whereas the results worsen using the FLAIR. When excluding the pathology, an improvement is observable for the CNN method using T1-CE. Both approaches utilizing the T1-CE sequence obtain the best mTREs, whereas the FLAIR is the least informative to guide the registration process. Besides, the exclusion of pathology from the distance measure computation improves the registration of the brain tissues surrounding the tumor. Thus, this work provides the first numerical evaluation of the influence of these parameters on the registration of longitudinal magnetic resonance images, and it can be helpful for developing future algorithms.
- 20 September 2022
- Published by Frontiers Media SA in Frontiers in Neuroimaging
- Vol. 1, 977491
Open AccessQuantitative evaluation of the influence of multiple MRI sequences and of pathological tissues on the registration of longitudinal data acquired during brain tumor treatment
Registration methods facilitate the comparison of multiparametric magnetic resonance images acquired at different stages of brain tumor treatments. Image-based registration solutions are influenced by the sequences chosen to compute the distance measure, and the lack of image correspondences due to the resection cavities and pathological tissues. Nonetheless, an evaluation of the impact of these input parameters on the registration of longitudinal data is still missing. This work evaluates the influence of multiple sequences, namely T1-weighted (T1), T2-weighted (T2), contrast enhanced T1-weighted (T1-CE), and T2 Fluid Attenuated Inversion Recovery (FLAIR), and the exclusion of the pathological tissues on the non-rigid registration of pre- and post-operative images. We here investigate two types of registration methods, an iterative approach and a convolutional neural network solution based on a 3D U-Net. We employ two test sets to compute the mean target registration error (mTRE) based on corresponding landmarks. In the first set, markers are positioned exclusively in the surroundings of the pathology. The methods employing T1-CE achieves the lowest mTREs, with a improvement up to 0.8 mm for the iterative solution. The results are higher than the baseline when using the FLAIR sequence. When excluding the pathology, lower mTREs are observable for most of the methods. In the second test set, corresponding landmarks are located in the entire brain volumes. Both solutions employing T1-CE obtain the lowest mTREs, with a decrease up to 1.16 mm for the iterative method, whereas the results worsen using the FLAIR. When excluding the pathology, an improvement is observable for the CNN method using T1-CE. Both approaches utilizing the T1-CE sequence obtain the best mTREs, whereas the FLAIR is the least informative to guide the registration process. Besides, the exclusion of pathology from the distance measure computation improves the registration of the brain tissues surrounding the tumor. Thus, this work provides the first numerical evaluation of the influence of these parameters on the registration of longitudinal magnetic resonance images, and it can be helpful for developing future algorithms.
- Open Access
- 7 October 2020
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 15 (12) , 1963-1974
Enhanced registration of ultrasound volumes by segmentation of resection cavity in neurosurgical procedures
Purpose: Neurosurgeons can have a better understanding of surgical procedures by comparing ultrasound images obtained at different phases of the tumor resection. However, establishing a direct mapping between subsequent acquisitions is challenging due to the anatomical changes happening during surgery. We propose here a method to improve the registration of ultrasound volumes, by excluding the resection cavity from the registration process.Methods: The first step of our approach includes the automatic segmentation of the resection cavities in ultrasound volumes, acquired during and after resection. We used a convolution neural network inspired by the 3D U-Net. Then, subsequent ultrasound volumes are registered by excluding the contribution of resection cavity.Results: Regarding the segmentation of the resection cavity, the proposed method achieved a mean DICE index of 0.84 on 27 volumes. Concerning the registration of the subsequent ultrasound acquisitions, we reduced the mTRE of the volumes acquired before and during resection from 3.49 to 1.22 mm. For the set of volumes acquired before and after removal, the mTRE improved from 3.55 to 1.21 mm.Conclusions: We proposed an innovative registration algorithm to compensate the brain shift affecting ultrasound volumes obtained at subsequent phases of neurosurgical procedures. To the best of our knowledge, our method is the first to exclude automatically segmented resection cavities in the registration of ultrasound volumes in neurosurgery.
- 7 October 2020
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 15 (12) , 1963-1974
Open AccessEnhanced registration of ultrasound volumes by segmentation of resection cavity in neurosurgical procedures
Purpose: Neurosurgeons can have a better understanding of surgical procedures by comparing ultrasound images obtained at different phases of the tumor resection. However, establishing a direct mapping between subsequent acquisitions is challenging due to the anatomical changes happening during surgery. We propose here a method to improve the registration of ultrasound volumes, by excluding the resection cavity from the registration process.Methods: The first step of our approach includes the automatic segmentation of the resection cavities in ultrasound volumes, acquired during and after resection. We used a convolution neural network inspired by the 3D U-Net. Then, subsequent ultrasound volumes are registered by excluding the contribution of resection cavity.Results: Regarding the segmentation of the resection cavity, the proposed method achieved a mean DICE index of 0.84 on 27 volumes. Concerning the registration of the subsequent ultrasound acquisitions, we reduced the mTRE of the volumes acquired before and during resection from 3.49 to 1.22 mm. For the set of volumes acquired before and after removal, the mTRE improved from 3.55 to 1.21 mm.Conclusions: We proposed an innovative registration algorithm to compensate the brain shift affecting ultrasound volumes obtained at subsequent phases of neurosurgical procedures. To the best of our knowledge, our method is the first to exclude automatically segmented resection cavities in the registration of ultrasound volumes in neurosurgery.
- Open Access
Registration of ultrasound volumes based on Euclidean distance transform
During neurosurgical operations, surgeons can decide to acquire intraoperative data to better proceed with the removal of a tumor. A valid option is given by ultrasound (US) imaging, which can be easily obtained at subsequent surgical stages, giving therefore multiple updates of the resection cavity. To improve the efficacy of the intraoperative guidance, neurosurgeons may benefit from having a direct correspondence between anatomical structures identified at different US acquisitions. In this context, the commonly available neuronavigation systems already provide registration methods, which however are not enough accurate to overcome the anatomical changes happening during resection. Therefore, our aim with this work is to improve the registration of intraoperative US volumes. In the proposed methodology, first a distance mapping of automatically segmented anatomical structures is computed and then the transformed images are utilized in the registration step. Our solution is tested on a public dataset of 17 cases, where the average landmark registration error between volumes acquired at the beginning and at the end of neurosurgical procedures is reduced from 3.55mm to 1.27mm.
Open AccessRegistration of ultrasound volumes based on Euclidean distance transform
During neurosurgical operations, surgeons can decide to acquire intraoperative data to better proceed with the removal of a tumor. A valid option is given by ultrasound (US) imaging, which can be easily obtained at subsequent surgical stages, giving therefore multiple updates of the resection cavity. To improve the efficacy of the intraoperative guidance, neurosurgeons may benefit from having a direct correspondence between anatomical structures identified at different US acquisitions. In this context, the commonly available neuronavigation systems already provide registration methods, which however are not enough accurate to overcome the anatomical changes happening during resection. Therefore, our aim with this work is to improve the registration of intraoperative US volumes. In the proposed methodology, first a distance mapping of automatically segmented anatomical structures is computed and then the transformed images are utilized in the registration step. Our solution is tested on a public dataset of 17 cases, where the average landmark registration error between volumes acquired at the beginning and at the end of neurosurgical procedures is reduced from 3.55mm to 1.27mm.
- 24 October 2019
- Published by Springer Nature
- p. 127-135
Registration of Ultrasound Volumes Based on Euclidean Distance Transform
- 24 October 2019
- Published by Springer Nature
- p. 127-135
Registration of Ultrasound Volumes Based on Euclidean Distance Transform
- Open Access
- 7 August 2019
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 14 (10) , 1697-1713
Segmentation-based registration of ultrasound volumes for glioma resection in image-guided neurosurgery
Purpose In image-guided surgery for glioma removal, neurosurgeons usually plan the resection on images acquired before surgery and use them for guidance during the subsequent intervention. However, after the surgical procedure has begun, the preplanning images become unreliable due to the brain shift phenomenon, caused by modifications of anatomical structures and imprecisions in the neuronavigation system. To obtain an updated view of the resection cavity, a solution is to collect intraoperative data, which can be additionally acquired at different stages of the procedure in order to provide a better understanding of the resection. A spatial mapping between structures identified in subsequent acquisitions would be beneficial. We propose here a fully automated segmentation-based registration method to register ultrasound (US) volumes acquired at multiple stages of neurosurgery. Methods We chose to segment sulci and falx cerebri in US volumes, which remain visible during resection. To automatically segment these elements, first we trained a convolutional neural network on manually annotated structures in volumes acquired before the opening of the dura mater and then we applied it to segment corresponding structures in different surgical phases. Finally, the obtained masks are used to register US volumes acquired at multiple resection stages. Results Our method reduces the mean target registration error (mTRE) between volumes acquired before the opening of the dura mater and during resection from 3.49 mm (± 1.55 mm) to 1.36 mm (± 0.61 mm). Moreover, the mTRE between volumes acquired before opening the dura mater and at the end of the resection is reduced from 3.54 mm (± 1.75 mm) to 2.05 mm (± 1.12 mm). Conclusion The segmented structures demonstrated to be good candidates to register US volumes acquired at different neurosurgical phases. Therefore, our solution can compensate brain shift in neurosurgical procedures involving intraoperative US data.
- 7 August 2019
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 14 (10) , 1697-1713
Open AccessSegmentation-based registration of ultrasound volumes for glioma resection in image-guided neurosurgery
Purpose In image-guided surgery for glioma removal, neurosurgeons usually plan the resection on images acquired before surgery and use them for guidance during the subsequent intervention. However, after the surgical procedure has begun, the preplanning images become unreliable due to the brain shift phenomenon, caused by modifications of anatomical structures and imprecisions in the neuronavigation system. To obtain an updated view of the resection cavity, a solution is to collect intraoperative data, which can be additionally acquired at different stages of the procedure in order to provide a better understanding of the resection. A spatial mapping between structures identified in subsequent acquisitions would be beneficial. We propose here a fully automated segmentation-based registration method to register ultrasound (US) volumes acquired at multiple stages of neurosurgery. Methods We chose to segment sulci and falx cerebri in US volumes, which remain visible during resection. To automatically segment these elements, first we trained a convolutional neural network on manually annotated structures in volumes acquired before the opening of the dura mater and then we applied it to segment corresponding structures in different surgical phases. Finally, the obtained masks are used to register US volumes acquired at multiple resection stages. Results Our method reduces the mean target registration error (mTRE) between volumes acquired before the opening of the dura mater and during resection from 3.49 mm (± 1.55 mm) to 1.36 mm (± 0.61 mm). Moreover, the mTRE between volumes acquired before opening the dura mater and at the end of the resection is reduced from 3.54 mm (± 1.75 mm) to 2.05 mm (± 1.12 mm). Conclusion The segmented structures demonstrated to be good candidates to register US volumes acquired at different neurosurgical phases. Therefore, our solution can compensate brain shift in neurosurgical procedures involving intraoperative US data.