Jie-Chung Lou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie-Chung Lou has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Jia-Yun Han
National Sun Yat-Sen University
9 shared publications- Wei-Lung Tseng
National Sun Yat-Sen University
4 shared publications Chien-Er Huang
3 shared publicationsShih-Wei Huang
Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan, Republic of China
3 shared publicationsTing-Wei Chang
National Sun Yat-Sen University
3 shared publicationsYu-Jen Huang
Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan, Republic of China
3 shared publications
Latest Publications
- Open Access
- 1 March 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (53) , 25627-25638
High removal of haloacetic acids from treated drinking water using bio-activated carbon method
This study focused on an effective method of using bio-activated carbon to treat excess amounts of haloacetic acids (HAAs) in treated drinking water from a water treatment plant. Experiments were conducted in a pilot-scale treatment system to evaluate the removal of HAAs in drinking water using a biological activated carbon filter (BACF). HAAs have been thought to be one possible nutrient that supports heterotrophic bacteria’s regrowth in drinking water. Under neutral conditions, the results showed that the pilot-scale treatment system reduced approximately 80% of HAAs. At increased alkalization conditions, the output water treated by the pilot-scale treatment system by the BACF showed an increased removal of HAAs. In addition, the concentration of assimilable organic carbon (AOC) primarily indicates micro-organisms’ growth in the water supply network. The amount of AOC in water is reduced after BACF treatment. The empirical equation for the HAAs concentrations that can reduce pathogenic contamination in the treated water was established by examining other nutrients (e.g. dissolved organic carbon), with ultraviolet absorbance at 254 nm wavelength (UV254), and ammonia (nitrogen) concentration. These findings may be useful in designing advanced processes for conventional water treatment plants or for managing water treatment and distribution systems that provide high-quality drinking water.
- 1 March 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (53) , 25627-25638
Open AccessHigh removal of haloacetic acids from treated drinking water using bio-activated carbon method
This study focused on an effective method of using bio-activated carbon to treat excess amounts of haloacetic acids (HAAs) in treated drinking water from a water treatment plant. Experiments were conducted in a pilot-scale treatment system to evaluate the removal of HAAs in drinking water using a biological activated carbon filter (BACF). HAAs have been thought to be one possible nutrient that supports heterotrophic bacteria’s regrowth in drinking water. Under neutral conditions, the results showed that the pilot-scale treatment system reduced approximately 80% of HAAs. At increased alkalization conditions, the output water treated by the pilot-scale treatment system by the BACF showed an increased removal of HAAs. In addition, the concentration of assimilable organic carbon (AOC) primarily indicates micro-organisms’ growth in the water supply network. The amount of AOC in water is reduced after BACF treatment. The empirical equation for the HAAs concentrations that can reduce pathogenic contamination in the treated water was established by examining other nutrients (e.g. dissolved organic carbon), with ultraviolet absorbance at 254 nm wavelength (UV254), and ammonia (nitrogen) concentration. These findings may be useful in designing advanced processes for conventional water treatment plants or for managing water treatment and distribution systems that provide high-quality drinking water.
- 24 February 2015
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 226 (3) , 1-9
Characterization of Single-Walled Carbon Nanotubes and Adsorption of Perchlorate in Water
- 24 February 2015
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 226 (3) , 1-9
Characterization of Single-Walled Carbon Nanotubes and Adsorption of Perchlorate in Water
- 23 July 2014
- Published by Taylor & Francis in Urban Water Journal
- Vol. 12 (8) , 672-677
Reducing the concentration of assimilable organic carbon (AOC) in treated drinking water
This study focuses on reducing the concentration of assimilable organic carbon (AOC) in treated drinking water. Experiments were conducted to evaluate the efficiency of AOC removal by biological activated carbon filters (BACF) in a pilot-scale system. The measured values of AOC in treated drinking water were approximately 59.0 ± 8.6 μg acetate-C/L. The results show that BACFs reduce the total concentration of AOC. The concentration of AOC primarily indicates microbial growth in a water supply network, and the amount of AOC in the water is significantly reduced after BACF treatment. After BACF treatment, the removal of AOC was approximately 58% after 40 min of empty-bed contact time. An AOC empirical equation was established by determining the relationship between water quality parameters, such as total organic carbon, dissolved organic carbon, UV254, ammonia nitrogen, and total phosphorous.
- 23 July 2014
- Published by Taylor & Francis in Urban Water Journal
- Vol. 12 (8) , 672-677
Reducing the concentration of assimilable organic carbon (AOC) in treated drinking water
This study focuses on reducing the concentration of assimilable organic carbon (AOC) in treated drinking water. Experiments were conducted to evaluate the efficiency of AOC removal by biological activated carbon filters (BACF) in a pilot-scale system. The measured values of AOC in treated drinking water were approximately 59.0 ± 8.6 μg acetate-C/L. The results show that BACFs reduce the total concentration of AOC. The concentration of AOC primarily indicates microbial growth in a water supply network, and the amount of AOC in the water is significantly reduced after BACF treatment. After BACF treatment, the removal of AOC was approximately 58% after 40 min of empty-bed contact time. An AOC empirical equation was established by determining the relationship between water quality parameters, such as total organic carbon, dissolved organic carbon, UV254, ammonia nitrogen, and total phosphorous.
- 18 January 2014
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 225 (2) , 1-9
Removal of Trihalomethanes and Haloacetic Acids from Treated Drinking Water by Biological Activated Carbon Filter
- 18 January 2014
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 225 (2) , 1-9
Removal of Trihalomethanes and Haloacetic Acids from Treated Drinking Water by Biological Activated Carbon Filter
- Open Access
- 11 September 2012
- Published by Elsevier in Desalination and Water Treatment
- Vol. 47 (1-3) , 11-16
Control of assimilable organic carbon (AOC) concentrations in a water distribution system
The aim of this study is to measure the bioavailable organic matter content in water. This study examines the changes in assimilable organic carbon (AOC) concentrations in a traditional water treatment plant in southern Taiwan and its associate water distribution system. The addition of chlorine to raw water is shown to produce an increase in AOC, resulting in waterborne AOC concentrations in excess of 50 μg acetate-C/L in some circumstances. Examination of water distribution networks indicate that AOC values decrease as the distance from the treatment facility increases. The residual chlorine concentrations in the distribution system must be in the range from 0.52 to 0.73 mg/L.
- 11 September 2012
- Published by Elsevier in Desalination and Water Treatment
- Vol. 47 (1-3) , 11-16
Open AccessControl of assimilable organic carbon (AOC) concentrations in a water distribution system
The aim of this study is to measure the bioavailable organic matter content in water. This study examines the changes in assimilable organic carbon (AOC) concentrations in a traditional water treatment plant in southern Taiwan and its associate water distribution system. The addition of chlorine to raw water is shown to produce an increase in AOC, resulting in waterborne AOC concentrations in excess of 50 μg acetate-C/L in some circumstances. Examination of water distribution networks indicate that AOC values decrease as the distance from the treatment facility increases. The residual chlorine concentrations in the distribution system must be in the range from 0.52 to 0.73 mg/L.
- 9 May 2012
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 47 (10) , 1478-1485
Removal of disinfection by-products in raw water using a biological powder-activated carbon system
This study investigates the removal efficiency of disinfection by-products (DBPs) in raw water at a water treatment plant using a biological powder-activated carbon system (BPACS). The presence of an excessive amount of DBPs has a large impact on the water quality of drinking water treated from the purification process. This study collected rapidly filtered water from an advanced water treatment plant for use in experiments on raw water. The removal efficiency of the trihalomethane formation potential (THMFP) and haloacetic acids formation potential (HAAFP) was studied under various hydraulic retention times and under organic DOC loadings. The results showed that the BPACS lowered the average concentration of dissolved organic carbon (DOC), UV254 and the SUVA value (equivalent to UV254/DOC) in raw water. The system efficiently removed the THMFP and HAAFP during the treatment of the three primary organic carbon items. These results highlight the importance of the BPACS for efficiently treating disinfection by-products. These discoveries provide important information on biological degradation behaviors that can remove excessive amounts of disinfection by-products from drinking water.
- 9 May 2012
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 47 (10) , 1478-1485
Removal of disinfection by-products in raw water using a biological powder-activated carbon system
This study investigates the removal efficiency of disinfection by-products (DBPs) in raw water at a water treatment plant using a biological powder-activated carbon system (BPACS). The presence of an excessive amount of DBPs has a large impact on the water quality of drinking water treated from the purification process. This study collected rapidly filtered water from an advanced water treatment plant for use in experiments on raw water. The removal efficiency of the trihalomethane formation potential (THMFP) and haloacetic acids formation potential (HAAFP) was studied under various hydraulic retention times and under organic DOC loadings. The results showed that the BPACS lowered the average concentration of dissolved organic carbon (DOC), UV254 and the SUVA value (equivalent to UV254/DOC) in raw water. The system efficiently removed the THMFP and HAAFP during the treatment of the three primary organic carbon items. These results highlight the importance of the BPACS for efficiently treating disinfection by-products. These discoveries provide important information on biological degradation behaviors that can remove excessive amounts of disinfection by-products from drinking water.
- 23 September 2011
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 46 (12) , 1357-1365
Removal of dissolved organic matter (DOM) from raw water by single-walled carbon nanotubes (SWCNTs)
Dissolved organic matter (DOM) in raw water is a precursor for the formation of disinfection by-products (DBPs) during chlorination at a water treatment plant in southern Taiwan. The presence of DOM also has a large impact on the behavior of nanoparticles. The adsorption kinetics of single-walled carbon nanotubes (SWCNTs) was investigated in the presence of DOM as a possible technique for the pretreatment of DBP precursors. pH, ionic strength and temperature are major factors in adsorption tests. Experimental results indicated that adsorption reached equilibrium after 120 min. Additionally, the adsorption capacity of SWCNTs increased with an increasing DOM concentration and decreased with an increasing ionic strength. The optimum adsorption model out of a selection including the Modified Freundlich equation, the Pseudo-first-order equation and Pesudo-second order equation, was the Modified Freundlich equation model. The intraparticle diffusion equation model was also examined. The adsorption process was controlled by pore diffusion that was confirmed by the fits of intra-particle diffusion model. The maximum adsorption capacity was 26.1–20.8 mg/g at 4°C and 45°C. Isotherm adsorption results demonstrated that the adsorption of DOM onto SWCNTs was favorable at a high initial DOM concentration and at low ionic strength, pH and temperature. These findings highlighted the importance of pretreatments and the presence of DOM on the adsorption behavior of nanomaterials.
- 23 September 2011
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 46 (12) , 1357-1365
Removal of dissolved organic matter (DOM) from raw water by single-walled carbon nanotubes (SWCNTs)
Dissolved organic matter (DOM) in raw water is a precursor for the formation of disinfection by-products (DBPs) during chlorination at a water treatment plant in southern Taiwan. The presence of DOM also has a large impact on the behavior of nanoparticles. The adsorption kinetics of single-walled carbon nanotubes (SWCNTs) was investigated in the presence of DOM as a possible technique for the pretreatment of DBP precursors. pH, ionic strength and temperature are major factors in adsorption tests. Experimental results indicated that adsorption reached equilibrium after 120 min. Additionally, the adsorption capacity of SWCNTs increased with an increasing DOM concentration and decreased with an increasing ionic strength. The optimum adsorption model out of a selection including the Modified Freundlich equation, the Pseudo-first-order equation and Pesudo-second order equation, was the Modified Freundlich equation model. The intraparticle diffusion equation model was also examined. The adsorption process was controlled by pore diffusion that was confirmed by the fits of intra-particle diffusion model. The maximum adsorption capacity was 26.1–20.8 mg/g at 4°C and 45°C. Isotherm adsorption results demonstrated that the adsorption of DOM onto SWCNTs was favorable at a high initial DOM concentration and at low ionic strength, pH and temperature. These findings highlighted the importance of pretreatments and the presence of DOM on the adsorption behavior of nanomaterials.
- 29 June 2011
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 184 (6) , 3491-3501
Comparing removal of trace organic compounds and assimilable organic carbon (AOC) at advanced and traditional water treatment plants
Stability of drinking water can be indicated by the assimilable organic carbon (AOC). This AOC value represents the regrowth capacity of microorganisms and has large impacts on the quality of drinking water in a distribution system. With respect to the effectiveness of traditional and advanced processing methods in removing trace organic compounds (including TOC, DOC, UV254, and AOC) from water, experimental results indicate that the removal rate of AOC at the Cheng Ching Lake water treatment plant (which utilizes advanced water treatment processes, and is hereinafter referred to as CCLWTP) is 54%, while the removal rate of AOC at the Gong Yuan water treatment plant (which uses traditional water treatment processes, and is hereinafter referred to as GYWTP) is 36%. In advanced water treatment units, new coagulation–sedimentation processes, rapid filters, and biological activated carbon filters can effectively remove AOC, total organic carbon (TOC), and dissolved organic carbon (DOC). In traditional water treatment units, coagulation–sedimentation processes are most effective in removing AOC. Simulation results and calculations made using the AutoNet method indicate that TOC, TDS, NH3-N, and NO3-N should be regularly monitored in the CCLWTP, and that TOC, temperature, and NH3-N should be regularly monitored in the GYWTP.
- 29 June 2011
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 184 (6) , 3491-3501
Comparing removal of trace organic compounds and assimilable organic carbon (AOC) at advanced and traditional water treatment plants
Stability of drinking water can be indicated by the assimilable organic carbon (AOC). This AOC value represents the regrowth capacity of microorganisms and has large impacts on the quality of drinking water in a distribution system. With respect to the effectiveness of traditional and advanced processing methods in removing trace organic compounds (including TOC, DOC, UV254, and AOC) from water, experimental results indicate that the removal rate of AOC at the Cheng Ching Lake water treatment plant (which utilizes advanced water treatment processes, and is hereinafter referred to as CCLWTP) is 54%, while the removal rate of AOC at the Gong Yuan water treatment plant (which uses traditional water treatment processes, and is hereinafter referred to as GYWTP) is 36%. In advanced water treatment units, new coagulation–sedimentation processes, rapid filters, and biological activated carbon filters can effectively remove AOC, total organic carbon (TOC), and dissolved organic carbon (DOC). In traditional water treatment units, coagulation–sedimentation processes are most effective in removing AOC. Simulation results and calculations made using the AutoNet method indicate that TOC, TDS, NH3-N, and NO3-N should be regularly monitored in the CCLWTP, and that TOC, temperature, and NH3-N should be regularly monitored in the GYWTP.
- 14 September 2010
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 178 (1-4) , 73-83
Variation and removal efficiency of assimilable organic carbon (AOC) in an advanced water treatment system
This study investigates the microorganism growth indicator and determines the assimilable organic carbon (AOC) content at the Cheng-Ching Lake Advanced Water Treatment Plant (CCLAWTP) in Kaohsiung, Taiwan. Notably, AOC is associated with the biological stability within the water distribution network and has garnered considerable attention in the environmental engineering field in recent years. Water samples were collected from the effluent of each unit in CCLAWTP once monthly during December 2008 to November 2009. Items of water quality related to carbon concentration levels, including AOC, total organic carbon, dissolved organic carbon, UV254, and specific ultraviolent absorbance were analyzed. Analytical results demonstrate that the average AOC concentration in raw water was 83.61 μg/L and reduced in freshwater was controlled at an average of 50 μg/L after an advanced treatment system of roughly 54% of AOC was removed in compliance with treatment plant standards. If AOC concentrations in freshwater can be reduced, study results can provide a direction for improving water treatment capabilities.
- 14 September 2010
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 178 (1-4) , 73-83
Variation and removal efficiency of assimilable organic carbon (AOC) in an advanced water treatment system
This study investigates the microorganism growth indicator and determines the assimilable organic carbon (AOC) content at the Cheng-Ching Lake Advanced Water Treatment Plant (CCLAWTP) in Kaohsiung, Taiwan. Notably, AOC is associated with the biological stability within the water distribution network and has garnered considerable attention in the environmental engineering field in recent years. Water samples were collected from the effluent of each unit in CCLAWTP once monthly during December 2008 to November 2009. Items of water quality related to carbon concentration levels, including AOC, total organic carbon, dissolved organic carbon, UV254, and specific ultraviolent absorbance were analyzed. Analytical results demonstrate that the average AOC concentration in raw water was 83.61 μg/L and reduced in freshwater was controlled at an average of 50 μg/L after an advanced treatment system of roughly 54% of AOC was removed in compliance with treatment plant standards. If AOC concentrations in freshwater can be reduced, study results can provide a direction for improving water treatment capabilities.
- 1 September 2010
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 181 (1-3) , 981-985
Recycling of Cu powder from industrial sludge by combined acid leaching, chemical exchange and ferrite process
- 1 September 2010
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 181 (1-3) , 981-985
Recycling of Cu powder from industrial sludge by combined acid leaching, chemical exchange and ferrite process