PAPeter Osei-Wusu Adueming

Peter Osei-Wusu Adueming

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peter Osei-Wusu Adueming has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Modular 3D-printed biophotonic platform for cost-effective hyperspectral and polarimetric imaging

    by Rabbi Boateng, Hampus Månefjord, Jerry Opoku-Ansah, Peter Osei-Wusu Adueming, Andrew Huzortey, Moses Jojo Eghan, Benjamin Anderson, Kingsley Taah, Charles Lloyd Yeboah Amuah

    Hyperspectral imaging (HSI) provides a powerful, non-destructive method for obtaining spatially and spectrally resolved information across diverse applications. However, conventional systems remain limited by high cost, complexity, and bulkiness, restricting their use in resource-constrained environments. This study presents a cost-effective, modular hyperspectral and polarimetric imaging platform developed using 3D-printed components and open-source software control. The system integrates a linear variable long-pass filter (LV-LPF) mounted on a motorized translation stage with a monochrome CMOS camera and LED-based diffuse illumination, enabling continuous spectral scanning between 450–720 nm. Calibration and validation using laser and LED sources yielded a mean absolute error (MAE) of 10.0 nm, a spectral precision of 10 ± 1 nm FWHM, and a stable wavelength registration drift of ±4 nm. Radiometric analysis achieved an average signal-to-noise ratio (SNR) of 20 ± 3 dB across the visible spectrum. Application to healthy and diseased rice seeds demonstrated clear spectral and polarization-dependent contrasts, with mean degrees of linear polarization (DoLP) of 0.18 ± 0.05, revealing distinct structural and subsurface variations. The results confirm the system’s potential as an adaptable, low-cost optical imaging tool for crop-health assessment.

  • Open Access

    Diagnostic potential of near‐infrared spectroscopy in mild cognitive impairment and neurodegenerative disorders: Implications for resource‐limited settings

    by George Nkrumah Osei, Ansumana Bockarie, Albert Akpalu, Peter Osei‐Wusu Adueming, Maxwell Hubert Antwi, Foster Appiah, Linus Kpelle, David Mawutor Donkor, David Larbi Simpong

    BACKGROUND: Near‐infrared spectroscopy (NIRS) is emerging as a promising tool for early detection of mild cognitive impairment (MCI) and neurodegenerative diseases, especially where advanced imaging is limited. METHODOLOGY: This systematic review investigates NIRS's diagnostic capabilities. Adhering to Preferred Reporting Items for Systematic Reviews and Meta‐Analyses guidelines, we conducted a comprehensive review of studies using NIRS for cognitive assessment in MCI and neurodegenerative conditions. RESULTS/DISCUSSION: NIRS effectively assesses cognitive function, identifying reduced prefrontal connectivity in MCI and subjective cognitive decline (SCD). Interestingly, while SCD patients maintain stronger brain network integrity, NIRS reveals decreased oxyhemoglobin levels in Alzheimer's disease (AD) patients’ dorsolateral prefrontal cortex. Combining NIRS with graph analysis, cognitive tasks, and machine learning significantly boosts diagnostic accuracy. Moreover, NIRS can differentiate between neurodegenerative disorders and, with concurrent electroencephalography, offers enhanced understanding of brain connectivity issues in AD. Our findings emphasize NIRS's considerable potential to improve cognitive assessment and neurodegeneration diagnosis. Highlights: Mild cognitive impairment (MCI) individuals show disruptions in neurovascular coupling and functional connectivity, particularly in the dorsolateral prefrontal cortex during near‐infrared spectroscopy (NIRS) assessments. Significant reductions in oxyhemoglobin (HbO 2 ) levels are observed in the dorsolateral prefrontal cortex of amnestic MCI (aMCI) individuals compared to healthy controls. Individuals with subjective cognitive decline (SCD) show lower HbO 2 levels than healthy individuals, while aMCI individuals show even more pronounced reductions. The dorsolateral prefrontal cortex is identified as a critical area for Alzheimer's disease (AD) assessment using NIRS, correlating with cognitive performance. Differences in Broca's area activation during language tasks help distinguish behavioral variant frontotemporal dementia from AD, revealing unique cognitive profiles through NIRS.


  • Laser-induced fluorescence spectroscopy combined with multivariate analysis for rice seeds and grains discrimination

    by Rabbi Boateng, Jerry Opoku-Ansah, Charles Lloyd Yeboah Amuah, Peter Osei-Wusu Adueming, Andrew Huzortey, Kingsley Taah, Moses Jojo Eghan

    Rice is a staple food in sub-Saharan Africa, including Ghana. Local production is hindered by the use of rice grains for cultivation, which directly affects both yield and grain quality. This study employed laser-induced fluorescence spectroscopy (LIFS) combined with multivariate analysis to rapidly and non-destructively discriminate between rice seeds and grains, offering an alternative to conventional methods. Fluorescence spectra from rice seeds and grains from six locally cultivated rice varieties were analyzed using three pre-processing techniques (Z-score, first derivative, and second derivative) across four machine learning models: linear discriminant analysis (LDA), quadratic discriminant analysis (QDA), K-nearest neighbor (KNN), and support vector machine (SVM). Principal component analysis score plots and the Davies–Bouldin index were used to assess the separation between seeds and grains. The first and second derivatives outperformed the Z-score, with SVM performing well under the second derivative and KNN excelling under the first derivative. LDA and QDA varied depending on the rice variety and the pre-processing method. The best accuracy was achieved using the first derivative with KNN, achieving test accuracy and F1 scores ranging from 0.74 to 0.97 and 0.76 to 0.97, respectively, confirming that LIFS combined with multivariate techniques is an effective method for discriminating rice seeds and grains.


  • Open Access

    Analysis of Colorfastness in Metallic Prints Using Absorption Spectroscopy

    by Sylvia Owusua Donkor, Samuel Sonko Sackey, Michael Kwame Vowotor, Charles Lloyd Yeboah Amuah, Rabbi Boateng, Ebenezer Teye Tatchie, Jerry Opoku-Ansah, Peter Osei-Wusu Adueming

    Color is essential for the fashion and art of fabrics, with its retention being a quality measure of great significance for the brand and user. The colorfastness of some metallic fabrics has been established using absorption spectroscopy, by determining the quality and quantity of dye that bled after undergoing wash laundry processes. Two metallic fabrics (X and Y) and washing detergents (liquid and powdered) were used. The fabrics were washed using GyroWash machine set for normal (40°C) and hot (60°C) wash for durations of 60 min and 90 min. There was a repeat for a second wash. The wastewater after each wash (sample) was collected, and the absorption spectra were recorded using a double‐beam spectrophotometer. The quality of dyes drained was determined using Peakfit analysis to deconvolute the absorption spectrum to reveal the presence of multiple individual wavelengths, and quantified using their relative intensity values. The identified peaks were between 200 nm and 370 nm, which lie within the UV–Vis absorption band of synthetic dyes referred to as azo dyes. The liquid soap bled more dye under the same washing conditions, with fabric Y demonstrating an inferior ability to retain its dye compared to fabric X. A higher amount of dye was drained during the hot wash, with the amount of dye that bled from both fabrics reducing after the first wash. Euclidean similarity was performed using principal component analysis to identify the spectra close to the detergent solution (reference spectrum) in Euclidean distance sense. Points from the wastewater spectra similar to the reference had shorter absolute distances, indicating less bleeding, while more dissimilar points registered longer distance, indicating more bleeding. This absorption spectroscopy technique is scientific and objective compared to the conventional subjective gray scale method. It will help textile manufacturers develop standardized testing protocols to assess the colorfastness of metallic printed fabrics, ensuring that products meet quality standards before they reach the market.

  • Open Access

    A Feasibility Study on Monitoring Shelf Life of Bottled Natural Fruit Juice Using Laser-Induced Autofluorescence

    by Peter Osei-Wusu Adueming, Jerry Opoku-Ansah, Andrew Atiogbe Huzortey, Charles Lloyd Yeboah Amuah, Kwasi Nyandey, Moses Jojo Eghan, Benjamin Anderson, Samuel Sonko Sackey

    Shelf life of bottled natural fruit juice (BNFJ) provides relevant information on quality and authenticity for consumer protection. However, existing techniques for monitoring the shelf life of BNFJ are destructive and time-consuming. We report on using laser-induced autofluorescence (LIAF) spectroscopic technique in combination with multivariate analysis for shelf life monitoring of BNFJ. The LIAF spectra data were acquired for nine (9) continuous days on three batches of BNFJ samples purchased from a certified retailer. Deconvolution of the LIAF spectra revealed underlying peaks representing constituents of the BNFJ. Principal component analysis (PCA) was able to monitor the trend in the changes of the BNFJ as it aged. Partial least square regression (PLSR) predicted the exact day from the production of the BNFJ accurately at 96.6% and 98.8% in the training and testing sets, respectively. We, therefore, propose the LIAF combined with multivariate analysis as a potential tool for nondestructive, rapid, and relatively inexpensive monitoring of the shelf life of BNFJ.


  • A feasibility study on the use of a pocket-sized NIR spectrometer and multivariate algorithm to distinguish expired drugs from unexpired ones

    by Jerry Opoku-Ansah, Ewura Seidu Yahaya, Charles Lloyd Yeboah Amuah, Regina Nyorkeh, Agnes Adom-Konadu, Peter Osei-Wusu Adueming, Ernest Teye

    An onsite technique for determining drug integrity in sub-Saharan Africa is needed for ensuring drug integrity and enhancing public health.


  • Computer vision syndrome and its associated ergonomic factors among bank workers

    by Samuel Bert Boadi-Kusi, Peter Osei-Wusu Adueming, Francisca Ama Hammond, Ebenezer Oduro Antiri

    Purpose: To describe the prevalence, ergonomic factors associated with computer vision syndrome (CVS), as well as knowledge and practices of computer usage among bank workers in the Cape Coast Metropolis, Ghana. Materials and methods: A comprehensive eye examination was performed for 139 bankers in the Cape Coast Metropolis. Measurements of ergonomic practices at their workstations were carried out and self-administered questionnaires were used to collect socio-demographic data, symptoms of CVS and its associated factors as well as the knowledge, attitudes and practices of the bankers on CVS. Descriptive statistics and logistic regression were carried out to compute the different proportions and relevant associations. Results: Headaches (73.4%), eyestrain (65.5%) and itching (63.3%) were the most common reported symptoms. The prevalence of CVS in the study population was found to be 71.2% with a high level of poor ergonomic practices (78.4%) at the computer workstations. With regards to knowledge, attitudes and practices of the participants on CVS, 68.3% of the participants had low levels of knowledge on CVS, while 90.6% had negative attitudes towards CVS and 46.0% of the participants had poor practices. Conclusion: Bankers had a high prevalence of CVS. Ergonomic practices, females and computer usage were all associated significantly with the presence of CVS.


  • Laser-induced fluorescence combined with multivariate techniques identifies the geographical origin of antimalarial herbal plants

    by Charles Lloyd Yeboah Amuah, Moses Jojo Eghan, Benjamin Anderson, Peter Osei-Wusu Adueming, Jerry Opoku-Ansah, Paul Kingsley Buah-Bassuah

    Laser-induced fluorescence (LIF) combined with multivariate techniques has been used in identifying antimalarial herbal plants (AMHPs) based on their geographical origin. The AMHP samples were collected from four geographical origins (Abrafo, Jukwa, Nfuom, and Akotokyere) in the Cape CoastMetropolis, Ghana. LIF spectra data were recorded from the AMHP samples. Utilizing multivariate techniques, a training set for the first two principal components of the AMHP spectra data was modeled through the use of K-nearest neighbor (KNN), support vector nachine (SVM), and linear discriminant analysis (LDA) methods. The SVM andKNNmethods performed best with 100% success for the prediction data, while the LDA had a 99% success rate. The KNN and SVM methods are recommended for the identification of AMHPs based on their geographical origins. Deconvoluted peaks from the LIF spectra of all theAMHPsamples revealed compounds such as quercetin and berberine as being present in all the AMHPsamples. (C) 2020 Optical Society of America


  • Open Access

    Association between Poor Ergophthalmologic Practices and Computer Vision Syndrome among University Administrative Staff in Ghana

    by Samuel Bert Boadi-Kusi, Sampson Listowell Abu, George Oppong Acheampong, Peter Osei-Wusu Adueming, Emmanuel Kwasi Abu

    Aim. The aim of this study was to assess the prevalence of computer vision syndrome (CVS) and its associated ergonomic factors among university administrative staff in Ghana. Methods. A cross-sectional survey was conducted among 200 administrative staff of the University of Cape Coast. The procedure included a self-administered questionnaire, comprehensive ocular health examination, and assessment of computer workstation and lighting conditions. The prevalence of CVS among the subjects and the association between CVS and ergonomic practices were determined. Results. The mean age of the study sample was 31.0 ± 4.7 years, and the majority were males (56.0%). The prevalence of CVS was among 103 (51.5%)participants. Over a third of the respondents used computers for 6 or more hours daily. Significant association was found between CVS and poor ergonomic practices (χ = 15.175, p=0.001). Conclusion. In addition to poor ergonomic office setup, university administrative staff spend several hours behind computer screens leading to the development of CVS. Increased awareness of CVS and adherence to recommended ergonomic practices are necessary to reduce the prevalence of CVS and ultimately enhance work satisfaction and productivity.


  • Open Access

    Optical Identification of Plasmodium falciparum Malarial Byproduct for Parasite Density Estimation

    by Jerry Opoku-Ansah, Moses Jojo Eghan, Benjamin Anderson, Johnson Nyarko Boampong, Raymond Edziah, Peter Osei-Wusu Adueming, Charles Lloyd Yeboah Amuah

    Plasmodium falciparum (P. falciparum) malarial degree of infection, termed as parasite density (PD), estimation is vital for point-of-care diagnosis and treatment of the disease. In this work, we present application of optical techniques: optical absorption and multispectral imaging for P. falciparum malarial byproduct (hemozoin) detection in human‐infected blood samples to estimate PD. The blood samples were collected from volunteers who were tested positive for P. falciparum infections (i-blood), and after treatment, another set of blood samples (u-blood) were also taken. The i-blood samples were grouped based on PD (+, ++, +++, and ++++). Optical densities (ODs) of u-blood samples and i-blood samples at blood absorption bands of 405 nm, 541 nm, and 577 nm showed different optical absorption characteristics. Empirical computation of ratio of the ODs for the blood absorption bands revealed reduction in the ODs with increasing PD. Multispectral images containing uninfected red blood cells (u-RBCs) and P. falciparum‐infected red blood cells (i-RBCs) on unstained blood smear slides exhibited spectrally determined decrease in both reflected and scattered pixel intensities and increase in transmitted pixel intensities with increasing PD. We further propose a linear classification model based on Fisher’s approach using reflected, scattered, and transmitted pixel intensities for easy and inexpensive estimation of PD as an alternative to manual estimation of PD, currently, the widely used technique. Application of the optical techniques and the proposed linear classification model are therefore recommended for improved malaria diagnosis and therapy.