Mohammad Saad Billah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohammad Saad Billah has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Jay A. Farrell
Department of Electrical and Computer Engineering, University of California at Riverside, Riverside, CA, USA
1 shared publication - Muhammad Abdullah Arafat
Department of Electrical and Electronic Engineering Bangladesh University of Engineering and Technology Dhaka Bangladesh
1 shared publication Tahmida Binte Mahmud
Department of Electrical and Electronic Engineering, Bangladesh University of Engineering and Technology (BUET), Dhaka-1000, Bangladesh
1 shared publication
Latest Publications
- 6 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 28 (6) , 2092-2103
Calibration of Multi-LIDAR Systems: Application to Bucket Wheel Reclaimers
This paper presents a method to calibrate the extrinsic parameters of light detection and rangings (LIDARs) mounted on a bucket-wheel reclaimer (BWR). BWR's are widely used for stacking and reclaiming bulk materials in stockyards. Current BWR systems are either manually operated, remotely operated, or semiautomated using the real-time point cloud data generated by one or more LIDARs. The accurate calibration is of crucial importance as the accuracy of the earth frame point cloud data depends on it. The automated calibration is also a prerequisite for fully autonomous BWR control. The calibration of BWR systems is more difficult than many other LIDAR systems because of their limited pose variation capabilities and the environmental constraints of stockyards. This paper analyzes the problem, presents observability conditions, presents a method to estimate the calibration parameters, and discusses the challenges involved with BWR systems. The results demonstrate subdecimeter accuracy.
- 6 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 28 (6) , 2092-2103
Calibration of Multi-LIDAR Systems: Application to Bucket Wheel Reclaimers
This paper presents a method to calibrate the extrinsic parameters of light detection and rangings (LIDARs) mounted on a bucket-wheel reclaimer (BWR). BWR's are widely used for stacking and reclaiming bulk materials in stockyards. Current BWR systems are either manually operated, remotely operated, or semiautomated using the real-time point cloud data generated by one or more LIDARs. The accurate calibration is of crucial importance as the accuracy of the earth frame point cloud data depends on it. The automated calibration is also a prerequisite for fully autonomous BWR control. The calibration of BWR systems is more difficult than many other LIDAR systems because of their limited pose variation capabilities and the environmental constraints of stockyards. This paper analyzes the problem, presents observability conditions, presents a method to estimate the calibration parameters, and discusses the challenges involved with BWR systems. The results demonstrate subdecimeter accuracy.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 153-156
Retrieving and smoothing fundamental waves from noise corrupted ECG beat using Gaussian functions
ECG denoising is a prerequisite for modeling, detecting various artifacts, measuring component waveforms and for almost all computational analysis of ECG signal. Gaussian waveform is a good candidate for ECG modeling due to its similarity with the characteristic waves of ECG beat. This paper presents a novel method for denoising and smoothing ECG signal using Gaussian functions. The advantage of Gaussian modeling is that by fitting Gaussian waveforms it inherently extracts the fundamental waveforms from the noisy signal, removes wrinkles and makes the signal sufficiently smooth for accurate detection and measurement of the on-set and off-set of the characteristic waves. Sixteen Gaussian waves are used to model each noisy ECG beat. The proposed algorithm has been applied on ECG signals with different SNR values. The results show significant improvement in the output SNR.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 153-156
Retrieving and smoothing fundamental waves from noise corrupted ECG beat using Gaussian functions
ECG denoising is a prerequisite for modeling, detecting various artifacts, measuring component waveforms and for almost all computational analysis of ECG signal. Gaussian waveform is a good candidate for ECG modeling due to its similarity with the characteristic waves of ECG beat. This paper presents a novel method for denoising and smoothing ECG signal using Gaussian functions. The advantage of Gaussian modeling is that by fitting Gaussian waveforms it inherently extracts the fundamental waveforms from the noisy signal, removes wrinkles and makes the signal sufficiently smooth for accurate detection and measurement of the on-set and off-set of the characteristic waves. Sixteen Gaussian waves are used to model each noisy ECG beat. The proposed algorithm has been applied on ECG signals with different SNR values. The results show significant improvement in the output SNR.