SDSamuel Davis

Samuel Davis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Samuel Davis has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Rapid cancer diagnosis using deep learning–powered label-free subcellular-resolution photoacoustic histology

    by Byullee Park, Rui Cao, Yilin Luo, Cindy Liu, Yushun Zeng, Yide Zhang, Qifa Zhou, Samuel Davis, Massimo D’aPuzzo, Lihong V. Wang

    Traditional hematoxylin and eosin staining in formalin-fixed paraffin-embedded sections, while essential for diagnostic pathology, is time-consuming, labor intensive, and prone to artifacts that can obscure critical histological details. Label-free ultraviolet photoacoustic microscopy (UV-PAM) has emerged as a promising alternative, offering fast histology-like images without the need for traditional staining and excessive tissue preparation. However, current UV-PAM systems face challenges in achieving the high spatial resolution required for detailed histological analysis and diagnosis. To address this, we developed a subcellular-resolution UV-PAM (SRUV-PAM) system with a 240-nanometer resolution, enabled by the integration of a high numerical aperture (NA) objective lens (NA = 0.64) and the precise piezo actuators for fine scanning control. This configuration allows visualization of detailed nuclear structures. In addition, we demonstrated virtual staining of SRUV-PAM images via cycle-consistent generative adversarial networks and diagnosis of malignant and benign tumors in liver tissues via densely connected convolutional networks DenseNet-121, achieving an area under the receiver operating characteristic curve of 0.902.


  • Top Cited Papers

    Optical-resolution photoacoustic microscopy with a needle-shaped beam

    by Rui Cao, Jingjing Zhao, Lei Li, Lin Du, Yide Zhang, Yilin Luo, Laiming Jiang, Samuel Davis, Qifa Zhou, Adam de la Zerda, et al.

    Optical-resolution photoacoustic microscopy can visualize wavelength-dependent optical absorption at the cellular level. However, this technique suffers from a limited depth of field due to the tight focus of the optical excitation beam, making it challenging to acquire high-resolution images of samples with uneven surfaces or high-quality volumetric images without z scanning. To overcome this limitation, we propose needle-shaped beam photoacoustic microscopy, which can extend the depth of field to around a 28-fold Rayleigh length via customized diffractive optical elements. These diffractive optical elements generate a needle-shaped beam with a well-maintained beam diameter, a uniform axial intensity distribution and negligible sidelobes. The advantage of using needle-shaped beam photoacoustic microscopy is demonstrated via both histology-like imaging of fresh slide-free organs using a 266 nm laser and in vivo mouse-brain vasculature imaging using a 532 nm laser. This approach provides new perspectives for slide-free intraoperative pathological imaging and in vivo organ-level imaging.


  • Open Access

    Single‐shot optical projection tomography for high‐speed volumetric imaging of dynamic biological samples

    by Connor Darling, Samuel P. X. Davis, Sunil Kumar, Paul M. W. French, James McGinty

    A single‐shot adaptation of Optical Projection Tomography (OPT) for high‐speed volumetric snapshot imaging of dynamic mesoscopic biological samples is presented. Conventional OPT has been applied to in vivo imaging of animal models such as D. rerio, but the sequential acquisition of projection images typically requires samples to be immobilized during the acquisition. A proof‐of‐principle system capable of single‐shot tomography of a ~1 mm3 volume is presented, demonstrating camera‐limited rates of up to 62.5 volumes/s, which has been applied to 3D imaging of a freely swimming zebrafish embryo. This is achieved by recording eight projection views simultaneously on four low‐cost CMOS cameras. With no stage required to rotate the sample, this single‐shot OPT system can be implemented with a component cost of under £5000. The system design can be adapted to different sized fields of view and may be applied to a broad range of dynamic samples, including high throughput flow cytometry applied to model organisms and fluid dynamics studies.


  • Top Cited Papers

    Label-free intraoperative histology of bone tissue via deep-learning-assisted ultraviolet photoacoustic microscopy

    by Rui Cao, Scott D. Nelson, Samuel Davis, Yu Liang, Yilin Luo, Yide Zhang, Brooke Crawford, Lihong V. Wang

    Obtaining frozen sections of bone tissue for intraoperative examination is challenging. To identify the bony edge of resection, orthopaedic oncologists therefore rely on pre-operative X-ray computed tomography or magnetic resonance imaging. However, these techniques do not allow for accurate diagnosis or for intraoperative confirmation of the tumour margins, and in bony sarcomas, they can lead to bone margins up to 10-fold wider (1,000-fold volumetrically) than necessary. Here, we show that real-time three-dimensional contour-scanning of tissue via ultraviolet photoacoustic microscopy in reflection mode can be used to intraoperatively evaluate undecalcified and decalcified thick bone specimens, without the need for tissue sectioning. We validate the technique with gold-standard haematoxylin-and-eosin histology images acquired via a traditional optical microscope, and also show that an unsupervised generative adversarial network can virtually stain the ultraviolet-photoacoustic-microscopy images, allowing pathologists to readily identify cancerous features. Label-free and slide-free histology via ultraviolet photoacoustic microscopy may allow for rapid diagnoses of bone-tissue pathologies and aid the intraoperative determination of tumour margins.


  • Open Access

    The mitochondrial Ca 2+ uniporter MCU is required for normal glucose-stimulated insulin secretion in vitro and in vivo

    by Elizabeth Haythorne, Eleni Georgiadou, Matthew T. Dickerson, Livia Lopez-Noriega, Timothy J. Pullen, Gabriela da Silva Xavier, Samuel P.X. Davis, Aida Martinez-Sanchez, Francesca Semplici, Rosario Rizzuto, et al.

    Mitochondrial oxidative metabolism is central to glucose-stimulated insulin secretion (GSIS). Whether Ca 2+ uptake into pancreatic β-cell mitochondria potentiates or antagonises this process is still a matter of debate. Although the mitochondrial importer (MCU) complex is thought to represent the main route for Ca 2+ transport across the inner mitochondrial membrane, its role in β-cells has not previously been examined in vivo . Here, we inactivated the pore-forming subunit MCUa (MCU) selectively in the β-cell in mice using Ins1 Cre-mediated recombination. Glucose-stimulated mitochondrial Ca 2+ accumulation, ATP production and insulin secretion were strongly (pMCU null animals (βMCU-KO) in vitro . Interestingly, cytosolic Ca 2+ concentrations increased (pin vivo insulin secretion at 5 (p2+ uptake in pancreatic β-cells and is required for normal GSIS. The apparent compensatory mechanisms which maintain glucose tolerance in βMCU-KO mice remain to be established.

  • Open Access

    Convolutional neural networks for reconstruction of undersampled optical projection tomography data applied to in vivo imaging of zebrafish

    by Samuel P. X. Davis, Sunil Kumar, Yuriy Alexandrov, Ajay Bhargava, Gabriela da Silva Xavier, Guy A. Rutter, Paul Frankel, Erik Sahai, Seth Flaxman, Paul M. W. French, et al.

    Optical projection tomography (OPT) is a 3D mesoscopic imaging modality that can utilize absorption or fluorescence contrast. 3D images can be rapidly reconstructed from tomographic data sets sampled with sufficient numbers of projection angles using the Radon transform, as is typically implemented with optically cleared samples of the mm‐to‐cm scale. For in vivo imaging, considerations of phototoxicity and the need to maintain animals under anesthesia typically preclude the acquisition of OPT data at a sufficient number of angles to avoid artifacts in the reconstructed images. For sparse samples, this can be addressed with iterative algorithms to reconstruct 3D images from undersampled OPT data, but the data processing times present a significant challenge for studies imaging multiple animals. We show here that convolutional neural networks (CNN) can be used in place of iterative algorithms to remove artifacts—reducing processing time for an undersampled in vivo zebrafish dataset from 77 to 15 minutes. We also show that using CNN produces reconstructions of equivalent quality to compressed sensing with 40% fewer projections. We further show that diverse training data classes, for example, ex vivo mouse tissue data, can be used for CNN‐based reconstructions of OPT data of other species including live zebrafish.


  • Open Access

    Slice-illuminated optical projection tomography

    by Samuel P. X. Davis, Laura Wisniewski, Sunil Kumar, Teresa Correia, Simon R. Arridge, Paul Frankel, James McGinty, Paul M. W. French

    To improve the imaging performance of optical projection tomography (OPT) in live samples, we have explored a parallelized implementation of semi-confocal line illumination and detection to discriminate against scattered photons. Slice-illuminated OPT (sl-OPT) improves reconstruction quality in scattering samples by reducing interpixel crosstalk at the cost of increased acquisition time. For in vivo imaging, this can be ameliorated through the use of compressed sensing on angularly undersampled OPT data sets. Here, we demonstrate sl-OPT applied to 3D imaging of bead phantoms and live adult zebrafish.


  • Open Access

    OPTiM: Optical projection tomography integrated microscope using open-source hardware and software

    by Thomas Watson, Natalie Andrews, Samuel Davis, Laurence Bugeon, Margaret D. Dallman, James McGinty

    We describe the implementation of an OPT plate to perform optical projection tomography (OPT) on a commercial wide-field inverted microscope, using our open-source hardware and software. The OPT plate includes a tilt adjustment for alignment and a stepper motor for sample rotation as required by standard projection tomography. Depending on magnification requirements, three methods of performing OPT are detailed using this adaptor plate: a conventional direct OPT method requiring only the addition of a limiting aperture behind the objective lens; an external optical-relay method allowing conventional OPT to be performed at magnifications >4x; a remote focal scanning and region-of-interest method for improved spatial resolution OPT (up to ~1.6 μm). All three methods use the microscope’s existing incoherent light source (i.e. arc-lamp) and all of its inherent functionality is maintained for day-to-day use. OPT acquisitions are performed on in vivo zebrafish embryos to demonstrate the implementations’ viability.