Max T. B. Clabbers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Max T. B. Clabbers has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Tamir Gonen
Department of Biological Chemistry, University of California, Los Angeles, Los Angeles, CA 90095
12 shared publications - Johan Hattne
Howard Hughes Medical Institute, University of California, Los Angeles, USA
8 shared publications - Hongyi Xu
Research School of Chemistry, Australian National University, Acton ACT 2601, Australia
7 shared publications Michael W. Martynowycz
Howard Hughes Medical Institute, University of California, Los Angeles, CA, 90095, USA
5 shared publications- Xiaodong Zou
Department of Chemistry, Stockholm University, Stockholm, Sweden
4 shared publications - Michael Williams Martynowycz
Department of Structural Biology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, The State University of New York, Buffalo, New York, USA
3 shared publications
Latest Publications
- Open Access
- 29 May 2025
- Published by Wiley in Advanced Science
- Vol. 12 (30) , e04881
High‐Throughput MicroED for Probing Ion Channel Dynamics
Ion channels play a crucial role in ion transport and are integral to fundamental physiological processes. Understanding channel structures is essential for elucidating the mechanisms of ion permeation and selectivity beyond simple computational simulations. Visualizing dynamics at high resolution, however, remains a significant challenge by structural techniques. In this study, high‐throughput microcrystal electron diffraction (MicroED) is applied to explore the structural dynamics of two ion channels, the non‐selective ion channel NaK and its mutant, NaK2CNG. This approach utilizes automated data collection and processing to capture distinct structural substates from a large number of microcrystals, offering a deeper understanding of ion channel mechanisms. From a subset of NaK structures, consistent sodium binding at specific sites is observed. In contrast, NaK2CNG appears more dynamic and undergoes dilation of the selectivity filter upon potassium binding. Further, the conduction state of NaK2CNG appears to be influenced by channel gating. Comparative analysis of these structures suggests that plasticity of the selectivity filter may contribute to the non‐selectivity of these channels, potentially allowing dynamic control over ion passage. These studies demonstrate the potential to employ high‐throughput MicroED as a technique to address persistent questions regarding ion channel permeation, complementing current computational molecular dynamics studies.
- 29 May 2025
- Published by Wiley in Advanced Science
- Vol. 12 (30) , e04881
Open AccessHigh‐Throughput MicroED for Probing Ion Channel Dynamics
Ion channels play a crucial role in ion transport and are integral to fundamental physiological processes. Understanding channel structures is essential for elucidating the mechanisms of ion permeation and selectivity beyond simple computational simulations. Visualizing dynamics at high resolution, however, remains a significant challenge by structural techniques. In this study, high‐throughput microcrystal electron diffraction (MicroED) is applied to explore the structural dynamics of two ion channels, the non‐selective ion channel NaK and its mutant, NaK2CNG. This approach utilizes automated data collection and processing to capture distinct structural substates from a large number of microcrystals, offering a deeper understanding of ion channel mechanisms. From a subset of NaK structures, consistent sodium binding at specific sites is observed. In contrast, NaK2CNG appears more dynamic and undergoes dilation of the selectivity filter upon potassium binding. Further, the conduction state of NaK2CNG appears to be influenced by channel gating. Comparative analysis of these structures suggests that plasticity of the selectivity filter may contribute to the non‐selectivity of these channels, potentially allowing dynamic control over ion passage. These studies demonstrate the potential to employ high‐throughput MicroED as a technique to address persistent questions regarding ion channel permeation, complementing current computational molecular dynamics studies.
- Open Access
- 1 May 2025
- Published by AIP Publishing in Structural Dynamics
- Vol. 12 (3) , 034702
Recovering high-resolution information using energy filtering in MicroED
Inelastic scattering poses a significant challenge in electron crystallography by elevating background noise and broadening Bragg peaks, thereby reducing the overall signal-to-noise ratio. This is particularly detrimental to data quality in structural biology, as the diffraction signal is relatively weak. These effects are aggravated even further by the decay of the diffracted intensities as a result of accumulated radiation damage, and rapidly fading high-resolution information can disappear beneath the noise. Loss of high-resolution reflections can partly be mitigated using energy filtering, which removes inelastically scattered electrons and improves data quality and resolution. Here, we systematically compared unfiltered and energy-filtered microcrystal electron diffraction data from proteinase K crystals, first collecting an unfiltered dataset followed directly by a second sweep using the same settings but with the energy filter inserted. Our results show that energy filtering consistently reduces noise, sharpens Bragg peaks, and extends high-resolution information, even though the absorbed dose was doubled for the second pass. Importantly, our results demonstrate that high-resolution information can be recovered by inserting the energy filter slit. Energy-filtered datasets showed improved intensity statistics and better internal consistency, highlighting the effectiveness of energy filtering for improving data quality. These findings underscore its potential to overcome limitations in macromolecular electron crystallography, enabling higher-resolution structures with greater reliability.
- 1 May 2025
- Published by AIP Publishing in Structural Dynamics
- Vol. 12 (3) , 034702
Open AccessRecovering high-resolution information using energy filtering in MicroED
Inelastic scattering poses a significant challenge in electron crystallography by elevating background noise and broadening Bragg peaks, thereby reducing the overall signal-to-noise ratio. This is particularly detrimental to data quality in structural biology, as the diffraction signal is relatively weak. These effects are aggravated even further by the decay of the diffracted intensities as a result of accumulated radiation damage, and rapidly fading high-resolution information can disappear beneath the noise. Loss of high-resolution reflections can partly be mitigated using energy filtering, which removes inelastically scattered electrons and improves data quality and resolution. Here, we systematically compared unfiltered and energy-filtered microcrystal electron diffraction data from proteinase K crystals, first collecting an unfiltered dataset followed directly by a second sweep using the same settings but with the energy filter inserted. Our results show that energy filtering consistently reduces noise, sharpens Bragg peaks, and extends high-resolution information, even though the absorbed dose was doubled for the second pass. Importantly, our results demonstrate that high-resolution information can be recovered by inserting the energy filter slit. Energy-filtered datasets showed improved intensity statistics and better internal consistency, highlighting the effectiveness of energy filtering for improving data quality. These findings underscore its potential to overcome limitations in macromolecular electron crystallography, enabling higher-resolution structures with greater reliability.
- Open Access
Recovering high-resolution information using energy filtering in MicroED
Inelastic scattering poses a significant challenge in electron crystallography by elevating background noise and broadening Bragg peaks, thereby reducing the overall signal-to-noise ratio. This is particularly detrimental to data quality in structural biology, and the diffraction signal is relatively weak. These effects are aggravated even further by the decay of the diffracted intensities as result of accumulated radiation damage, and rapidly fading high-resolution information can disappear beneath the noise. Loss of high-resolution reflections can partly be mitigated using energy filtering, which removes inelastically scattered electrons and improves data quality and resolution. Here, we systematically compared unfiltered and energy-filtered MicroED data from proteinase K crystals, first collecting an unfiltered dataset followed directly by a second sweep using the same settings but with the energy filter inserted. Our results show that energy filtering consistently reduces noise, sharpenes Bragg peaks, and extends high-resolution information, even though the absorbed dose was doubled for the second pass. Importantly, our results demonstrate that high-resolution information can be recovered by inserting the energy filter slit. Energy-filtered datasets showed improved intensity statistics and better internal consistency, highlighting the effectiveness of energy filtering for improving data quality. These findings underscore its potential to overcome limitations in macromolecular electron crystallography, enabling higher-resolution structures with greater reliability.
Open AccessRecovering high-resolution information using energy filtering in MicroED
Inelastic scattering poses a significant challenge in electron crystallography by elevating background noise and broadening Bragg peaks, thereby reducing the overall signal-to-noise ratio. This is particularly detrimental to data quality in structural biology, and the diffraction signal is relatively weak. These effects are aggravated even further by the decay of the diffracted intensities as result of accumulated radiation damage, and rapidly fading high-resolution information can disappear beneath the noise. Loss of high-resolution reflections can partly be mitigated using energy filtering, which removes inelastically scattered electrons and improves data quality and resolution. Here, we systematically compared unfiltered and energy-filtered MicroED data from proteinase K crystals, first collecting an unfiltered dataset followed directly by a second sweep using the same settings but with the energy filter inserted. Our results show that energy filtering consistently reduces noise, sharpenes Bragg peaks, and extends high-resolution information, even though the absorbed dose was doubled for the second pass. Importantly, our results demonstrate that high-resolution information can be recovered by inserting the energy filter slit. Energy-filtered datasets showed improved intensity statistics and better internal consistency, highlighting the effectiveness of energy filtering for improving data quality. These findings underscore its potential to overcome limitations in macromolecular electron crystallography, enabling higher-resolution structures with greater reliability.
- Open Access
- 21 March 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 2779
Publisher Correction: Energy filtering enables macromolecular MicroED data at sub-atomic resolution
- 21 March 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 2779
Open AccessPublisher Correction: Energy filtering enables macromolecular MicroED data at sub-atomic resolution
- Open Access
- 6 March 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-6
Energy filtering enables macromolecular MicroED data at sub-atomic resolution
High-resolution information is important for accurate structure modeling but is challenging to attain in macromolecular crystallography due to the rapid fading of diffracted intensities at increasing resolution. While direct electron detection essentially eliminates the read-out noise during MicroED data collection, other sources of noise remain and limit the measurement of faint high-resolution reflections. Inelastic scattering significantly contributes to noise, raising background levels and broadening diffraction peaks. We demonstrate a substantial improvement in signal-to-noise ratio by using energy filtering to remove inelastically scattered electrons. This strategy results in sub-atomic resolution MicroED data from proteinase K crystals, enabling the visualization of detailed structural features. Interestingly, reducing the noise further reveals diffuse scattering that may hold additional structural information. Our findings suggest that combining energy filtering and direct detection provides more accurate measurements at higher resolution, facilitating precise model refinement and improved insights into protein structure and function.
- 6 March 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-6
Open AccessEnergy filtering enables macromolecular MicroED data at sub-atomic resolution
High-resolution information is important for accurate structure modeling but is challenging to attain in macromolecular crystallography due to the rapid fading of diffracted intensities at increasing resolution. While direct electron detection essentially eliminates the read-out noise during MicroED data collection, other sources of noise remain and limit the measurement of faint high-resolution reflections. Inelastic scattering significantly contributes to noise, raising background levels and broadening diffraction peaks. We demonstrate a substantial improvement in signal-to-noise ratio by using energy filtering to remove inelastically scattered electrons. This strategy results in sub-atomic resolution MicroED data from proteinase K crystals, enabling the visualization of detailed structural features. Interestingly, reducing the noise further reveals diffuse scattering that may hold additional structural information. Our findings suggest that combining energy filtering and direct detection provides more accurate measurements at higher resolution, facilitating precise model refinement and improved insights into protein structure and function.
- Open Access
Characterization of energy filtering slit widths for MicroED data collection
A favorable signal-to-noise ratio is essential for obtaining high-quality diffraction data in macromolecular electron crystallography. Inelastic scattering contributes significantly to the noise, reducing contrast between diffraction peaks and background, which complicates peak detection and compromises the accuracy of intensity integration. Energy filtering mitigates these challenges and enhances diffraction data quality by removing the inelastically scattered electrons, leading to reduced background noise and sharper Bragg peaks. Previously, we reported a substantial improvement in MicroED data quality and resolution with energy filtering. Here, we systematically evaluate the impact of different energy filter slit widths for optimal MicroED data collection. Data from proteinase K lamellae were collected using the 5, 10, and 20 eV energy filter slit widths. Our results show that the narrowest slit widths result in a stronger diffraction signal with lower background noise, improving the precision of the intensity measurements which resulted in better structural models. Our findings provide insights into the optimization of energy filter slit settings that, when paired with direct electron detection, enhance MicroED data collection strategies in MicroED by improving the signal-to-noise ratio, supporting higher quality data and ultimately enabling more precise structure determination.
Open AccessCharacterization of energy filtering slit widths for MicroED data collection
A favorable signal-to-noise ratio is essential for obtaining high-quality diffraction data in macromolecular electron crystallography. Inelastic scattering contributes significantly to the noise, reducing contrast between diffraction peaks and background, which complicates peak detection and compromises the accuracy of intensity integration. Energy filtering mitigates these challenges and enhances diffraction data quality by removing the inelastically scattered electrons, leading to reduced background noise and sharper Bragg peaks. Previously, we reported a substantial improvement in MicroED data quality and resolution with energy filtering. Here, we systematically evaluate the impact of different energy filter slit widths for optimal MicroED data collection. Data from proteinase K lamellae were collected using the 5, 10, and 20 eV energy filter slit widths. Our results show that the narrowest slit widths result in a stronger diffraction signal with lower background noise, improving the precision of the intensity measurements which resulted in better structural models. Our findings provide insights into the optimization of energy filter slit settings that, when paired with direct electron detection, enhance MicroED data collection strategies in MicroED by improving the signal-to-noise ratio, supporting higher quality data and ultimately enabling more precise structure determination.
- 20 December 2024
- Published by Springer Nature in Nature Protocols
- Vol. 20 (5) , 1275-1309
Comprehensive microcrystal electron diffraction sample preparation for cryo-EM
Microcrystal electron diffraction (MicroED) has advanced structural methods across a range of sample types, from small molecules to proteins. This cryogenic electron microscopy (cryo-EM) technique involves the continuous rotation of small 3D crystals in the electron beam, while a high-speed camera captures diffraction data in the form of a movie. The crystal structure is subsequently determined by using established X-ray crystallographic software. MicroED is a technique still under development, and hands-on expertise in sample preparation, data acquisition and processing is not always readily accessible. This comprehensive guide on MicroED sample preparation addresses commonly used methods for various sample categories, including room temperature solid-state small molecules and soluble and membrane protein crystals. Beyond detailing the steps of sample preparation for new users, and because every crystal requires unique growth and sample-preparation conditions, this resource provides instructions and optimization strategies for MicroED sample preparation. The protocol is suitable for users with expertise in biochemistry, crystallography, general cryo-EM and crystallography data processing. MicroED experiments, from sample vitrification to final structure, can take anywhere from one workday to multiple weeks, especially when cryogenic focused ion beam milling is involved.
- 20 December 2024
- Published by Springer Nature in Nature Protocols
- Vol. 20 (5) , 1275-1309
Comprehensive microcrystal electron diffraction sample preparation for cryo-EM
Microcrystal electron diffraction (MicroED) has advanced structural methods across a range of sample types, from small molecules to proteins. This cryogenic electron microscopy (cryo-EM) technique involves the continuous rotation of small 3D crystals in the electron beam, while a high-speed camera captures diffraction data in the form of a movie. The crystal structure is subsequently determined by using established X-ray crystallographic software. MicroED is a technique still under development, and hands-on expertise in sample preparation, data acquisition and processing is not always readily accessible. This comprehensive guide on MicroED sample preparation addresses commonly used methods for various sample categories, including room temperature solid-state small molecules and soluble and membrane protein crystals. Beyond detailing the steps of sample preparation for new users, and because every crystal requires unique growth and sample-preparation conditions, this resource provides instructions and optimization strategies for MicroED sample preparation. The protocol is suitable for users with expertise in biochemistry, crystallography, general cryo-EM and crystallography data processing. MicroED experiments, from sample vitrification to final structure, can take anywhere from one workday to multiple weeks, especially when cryogenic focused ion beam milling is involved.
- Open Access
Energy filtering enables macromolecular MicroED data at sub-atomic resolution
High resolution information is important for accurate structure modelling. However, this level of detail is typically difficult to attain in macromolecular crystallography because the diffracted intensities rapidly fade with increasing resolution. The problem cannot be circumvented by increasing the fluence as this leads to detrimental radiation damage. Previously, we demonstrated that high quality MicroED data can be obtained at low flux conditions using electron counting with direct electron detectors. The improved sensitivity and accuracy of these detectors essentially eliminate the read-out noise, such that the measurement of faint high-resolution reflections is limited by other sources of noise. Inelastic scattering is a major contributor of such noise, increasing background counts and broadening diffraction spots. Here, we demonstrate that a substantial improvement in signal-to-noise ratio can be achieved using an energy filter to largely remove the inelastically scattered electrons. This strategy resulted in sub-atomic resolution MicroED data from proteinase K crystals, enabling accurate structure modelling and the visualization of detailed features. Interestingly, filtering out the noise revealed diffuse scattering phenomena that can hold additional structural information. Our findings suggest that combining energy filtering and electron counting can provide more accurate measurements at higher resolution, providing better insights into protein function and facilitating more precise model refinement.
Open AccessEnergy filtering enables macromolecular MicroED data at sub-atomic resolution
High resolution information is important for accurate structure modelling. However, this level of detail is typically difficult to attain in macromolecular crystallography because the diffracted intensities rapidly fade with increasing resolution. The problem cannot be circumvented by increasing the fluence as this leads to detrimental radiation damage. Previously, we demonstrated that high quality MicroED data can be obtained at low flux conditions using electron counting with direct electron detectors. The improved sensitivity and accuracy of these detectors essentially eliminate the read-out noise, such that the measurement of faint high-resolution reflections is limited by other sources of noise. Inelastic scattering is a major contributor of such noise, increasing background counts and broadening diffraction spots. Here, we demonstrate that a substantial improvement in signal-to-noise ratio can be achieved using an energy filter to largely remove the inelastically scattered electrons. This strategy resulted in sub-atomic resolution MicroED data from proteinase K crystals, enabling accurate structure modelling and the visualization of detailed features. Interestingly, filtering out the noise revealed diffuse scattering phenomena that can hold additional structural information. Our findings suggest that combining energy filtering and electron counting can provide more accurate measurements at higher resolution, providing better insights into protein function and facilitating more precise model refinement.
- Open Access
- 25 February 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-15
A robust approach for MicroED sample preparation of lipidic cubic phase embedded membrane protein crystals
Crystallizing G protein-coupled receptors (GPCRs) in lipidic cubic phase (LCP) often yields crystals suited for the cryogenic electron microscopy (cryoEM) method microcrystal electron diffraction (MicroED). However, sample preparation is challenging. Embedded crystals cannot be targeted topologically. Here, we use an integrated fluorescence light microscope (iFLM) inside of a focused ion beam and scanning electron microscope (FIB-SEM) to identify fluorescently labeled GPCR crystals. Crystals are targeted using the iFLM and LCP is milled using a plasma focused ion beam (pFIB). The optimal ion source for preparing biological lamellae is identified using standard crystals of proteinase K. Lamellae prepared using either argon or xenon produced the highest quality data and structures. MicroED data are collected from the milled lamellae and the structures are determined. This study outlines a robust approach to identify and mill membrane protein crystals for MicroED and demonstrates plasma ion-beam milling is a powerful tool for preparing biological lamellae.
- 25 February 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-15
Open AccessA robust approach for MicroED sample preparation of lipidic cubic phase embedded membrane protein crystals
Crystallizing G protein-coupled receptors (GPCRs) in lipidic cubic phase (LCP) often yields crystals suited for the cryogenic electron microscopy (cryoEM) method microcrystal electron diffraction (MicroED). However, sample preparation is challenging. Embedded crystals cannot be targeted topologically. Here, we use an integrated fluorescence light microscope (iFLM) inside of a focused ion beam and scanning electron microscope (FIB-SEM) to identify fluorescently labeled GPCR crystals. Crystals are targeted using the iFLM and LCP is milled using a plasma focused ion beam (pFIB). The optimal ion source for preparing biological lamellae is identified using standard crystals of proteinase K. Lamellae prepared using either argon or xenon produced the highest quality data and structures. MicroED data are collected from the milled lamellae and the structures are determined. This study outlines a robust approach to identify and mill membrane protein crystals for MicroED and demonstrates plasma ion-beam milling is a powerful tool for preparing biological lamellae.
- Open Access
- 10 November 2022
- Published by Elsevier in Journal of Structural Biology: X
- Vol. 6, 100078
Hydrogens and hydrogen-bond networks in macromolecular MicroED data
- 10 November 2022
- Published by Elsevier in Journal of Structural Biology: X
- Vol. 6, 100078
Open AccessHydrogens and hydrogen-bond networks in macromolecular MicroED data