Christoph Polzer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christoph Polzer has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Hellerer
Multiphoton Imaging Lab, Munich University of Applied Sciences, 80335 Munich, Germany
5 shared publications - Joachim Oskar Rädler
Ludwig-Maximilians-Universität München
3 shared publications Mojtaba Mohseni
Multiphoton Imaging Lab, Munich University of Applied Sciences, 80335 Munich, Germany
3 shared publicationsStefan Ness
FG Protein Biochemistry & Cellular Microbiology, University of Applied Sciences Munich, 80335 Munich, Germany
2 shared publicationsAdrian Rühm
1 shared publicationAnna von Berg
1 shared publication
Latest Publications
- 18 October 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (21) , 5218-5221
All-fiber widely tunable ultrafast laser source for multimodal imaging in nonlinear microscopy
In this Letter, we present an all-fiber, easy-to-use, wavelength-tunable, ultrafast laser, based on soliton self-frequency shifting in an Er-doped polarization-maintaining very large mode area fiber. The system is tunable over 370 nm, starting at 1620 nm, with an average power of up to 1.5 W that emits 120 fs short laser pulses directly out of the fusion-spliced fiber without using bulky pulse compression optics. The output is subsequently frequency doubled to a wavelength range covering 810 nm up to almost 1000 nm with more than 500 mW average power and 120 fs pulse width. Having a polarization extinction ratio better than 40 dB and a of 1.1, the fully computer-controlled laser system presents a robust and compact laser source. These parameters make the laser perfectly suited for multimodal imaging in nonlinear microscopy.- 18 October 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (21) , 5218-5221
All-fiber widely tunable ultrafast laser source for multimodal imaging in nonlinear microscopy
In this Letter, we present an all-fiber, easy-to-use, wavelength-tunable, ultrafast laser, based on soliton self-frequency shifting in an Er-doped polarization-maintaining very large mode area fiber. The system is tunable over 370 nm, starting at 1620 nm, with an average power of up to 1.5 W that emits 120 fs short laser pulses directly out of the fusion-spliced fiber without using bulky pulse compression optics. The output is subsequently frequency doubled to a wavelength range covering 810 nm up to almost 1000 nm with more than 500 mW average power and 120 fs pulse width. Having a polarization extinction ratio better than 40 dB and a of 1.1, the fully computer-controlled laser system presents a robust and compact laser source. These parameters make the laser perfectly suited for multimodal imaging in nonlinear microscopy.- 7 August 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (9) , 4516-4530
Correlative two-color two-photon (2C2P) excitation STED microscopy
We present a two-color two-photon stimulated emission depletion microscopy technique (2C2P-STED) that correlates a confocal image with a super-resolved image employing the inherent self-referencing mechanism of nonlinear excitation. The novel approach overcomes the substantial challenge posed by two different imaging modalities in laser-scanning fluorescence microscopy for colocalization on the nanometer scale. Demonstrating the principle of 2C2P-STED, we show for the first time super-resolved images of the gram-positive bacteria Streptococcus pneumoniae TIGR4 pilus type- 1 . A signal-to-noise ratio (SINIR) greater than 10 was achieved in 2C2P excitation mode and approximately 70 nm details were resolved in 2P-STED. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
- 7 August 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (9) , 4516-4530
Correlative two-color two-photon (2C2P) excitation STED microscopy
We present a two-color two-photon stimulated emission depletion microscopy technique (2C2P-STED) that correlates a confocal image with a super-resolved image employing the inherent self-referencing mechanism of nonlinear excitation. The novel approach overcomes the substantial challenge posed by two different imaging modalities in laser-scanning fluorescence microscopy for colocalization on the nanometer scale. Demonstrating the principle of 2C2P-STED, we show for the first time super-resolved images of the gram-positive bacteria Streptococcus pneumoniae TIGR4 pilus type- 1 . A signal-to-noise ratio (SINIR) greater than 10 was achieved in 2C2P excitation mode and approximately 70 nm details were resolved in 2P-STED. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
- 22 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 103, 100
Nanometer-scale colocalization microscopy of Streptococcus pneumoniae filaments
We present numerical simulations and experiments employing two-photon excited fluorescence in a sum-frequency mixing scheme which could be used for colocalization experiments in biophysics. By means of numerical calculations using the Debye approximation, the point spread functions (PSF) of each focused laser beam as well as the resulting PSF of the two-color two-photon (2C2P) excitation are calculated and discussed. Experiments are performed on Streptococcus pneumoniae and on surface filaments (“pili”) of the bacteria. Two different fluorescent labels were used for staining the bacteria themselves as well as the surface filaments as structure of interest. Since one fluorophore is excited by one single laser and the other label only in the combination of both lasers, intrinsic colocalization of the signals on the nanometer scale is ensured. The two-color two-photon excitation is performed by an ultrashort fiber laser system with synchronized emission wavelengths at λ1 = 780 nm and λ2 = 1030 nm and pulse durations around 100 fs. The multiphoton microscopy approach provides high resolution and allows for three-dimensional imaging of bacteria in a volume of (5 x 5 x 5) μm3.
- 22 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 103, 100
Nanometer-scale colocalization microscopy of Streptococcus pneumoniae filaments
We present numerical simulations and experiments employing two-photon excited fluorescence in a sum-frequency mixing scheme which could be used for colocalization experiments in biophysics. By means of numerical calculations using the Debye approximation, the point spread functions (PSF) of each focused laser beam as well as the resulting PSF of the two-color two-photon (2C2P) excitation are calculated and discussed. Experiments are performed on Streptococcus pneumoniae and on surface filaments (“pili”) of the bacteria. Two different fluorescent labels were used for staining the bacteria themselves as well as the surface filaments as structure of interest. Since one fluorophore is excited by one single laser and the other label only in the combination of both lasers, intrinsic colocalization of the signals on the nanometer scale is ensured. The two-color two-photon excitation is performed by an ultrashort fiber laser system with synchronized emission wavelengths at λ1 = 780 nm and λ2 = 1030 nm and pulse durations around 100 fs. The multiphoton microscopy approach provides high resolution and allows for three-dimensional imaging of bacteria in a volume of (5 x 5 x 5) μm3.
- 22 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10882, 29
920 nm fiber laser delivering 100 fs pulses for nonlinear microscopy
This presentation focuses on ultrafast fiber lasers as excitation light-source for advanced microscopy. We will present our latest innovations and show how multiphoton microscopy can benefit from these developments. This will propel imaging techniques like TPEF, SHG, CARS or STED among others that excel conventional microscopy techniques in a deeper penetration depth, label-free imaging capability or higher spatial resolution. Wavelengths around 900 nm for addressing certain applications with fluorescent proteins and pulse durations as short as 100 fs remain a challenge for fiber lasers. TOPTICA has now launched the third generation of ultrafast fiber lasers overcoming these difficulties. The novel FF ultra laser platform is capable of generating such short pulses at not only the wavelengths 780 nm and 1050 nm but most recently at 920 nm too. This enables the imaging of the popular green fluorescent protein (GFP) and its derivatives with lowest possible power level because of the high efficiency. In the course of this work, we present selected applications proving the suitability of this industrial grade laser family for a broad variety of microscopic applications.
- 22 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10882, 29
920 nm fiber laser delivering 100 fs pulses for nonlinear microscopy
This presentation focuses on ultrafast fiber lasers as excitation light-source for advanced microscopy. We will present our latest innovations and show how multiphoton microscopy can benefit from these developments. This will propel imaging techniques like TPEF, SHG, CARS or STED among others that excel conventional microscopy techniques in a deeper penetration depth, label-free imaging capability or higher spatial resolution. Wavelengths around 900 nm for addressing certain applications with fluorescent proteins and pulse durations as short as 100 fs remain a challenge for fiber lasers. TOPTICA has now launched the third generation of ultrafast fiber lasers overcoming these difficulties. The novel FF ultra laser platform is capable of generating such short pulses at not only the wavelengths 780 nm and 1050 nm but most recently at 920 nm too. This enables the imaging of the popular green fluorescent protein (GFP) and its derivatives with lowest possible power level because of the high efficiency. In the course of this work, we present selected applications proving the suitability of this industrial grade laser family for a broad variety of microscopic applications.
- Open Access
- 1 February 2019
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 509 (3) , 839-844
Age related changes in cell stiffness of tendon stem/progenitor cells and a rejuvenating effect of ROCK-inhibition
- 1 February 2019
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 509 (3) , 839-844
Open AccessAge related changes in cell stiffness of tendon stem/progenitor cells and a rejuvenating effect of ROCK-inhibition
- 9 April 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (8) , 10230-10241
Resolution of spectral focusing in coherent Raman imaging
In this manuscript, we present a detailed investigation of the impact of dispersion on the spectral resolution achievable by the application of spectral focusing in coherent Raman imaging. Our results reveal the detrimental effect of third order dispersion that limits the resolution for group delay dispersion of 100 000 fs2 and more. Experimental examples for the exact determination of the described effects are given as well as a condensed presentation of the known equations. We introduce useful approximations to the latter, which serve to facilitate the straightforward integration of spectral focusing into any multimodal microscope.
- 9 April 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (8) , 10230-10241
Resolution of spectral focusing in coherent Raman imaging
In this manuscript, we present a detailed investigation of the impact of dispersion on the spectral resolution achievable by the application of spectral focusing in coherent Raman imaging. Our results reveal the detrimental effect of third order dispersion that limits the resolution for group delay dispersion of 100 000 fs2 and more. Experimental examples for the exact determination of the described effects are given as well as a condensed presentation of the known equations. We introduce useful approximations to the latter, which serve to facilitate the straightforward integration of spectral focusing into any multimodal microscope.
- Open Access
- 31 July 2017
- Published by Optica Publishing Group in Optica
- Vol. 4 (8) , 911-918
Sub-diffraction discrimination with polarization-resolved two-photon excited fluorescence microscopy
Imaging molecular structures separated by distances of a few nanometers still represents a complex challenge. Moreover, it is normally restricted to observations on thin (few micrometers) samples. In this work, we rotate the polarization of the excitation beam of two-photon excited fluorescence (TPEF) images to show that fluorescent structures at the molecular scale can be discriminated in a living organism. The polarization rotation generates a modulation of the signal intensity in each pixel of the TPEF images that carry information related to the fluorophore orientation. We analyze the signal modulation in every pixel of the polarization-resolved (PR) TPEF images through a Fourier analysis and generate images for the different Fourier components. Doing that, we show that two fluorophores oriented in different directions can be distinguished. Although by imaging the Fourier components the resolution of the optical system restricts the exact localization of two close molecules, discrimination is still possible even when the molecules are located at sub-diffraction distances. We propose a model that predicts this behavior, and demonstrate it experimentally in the neurons of a living Caenorhabditis elegans nematode, where we distinguish the walls of an axon with a diameter below the objective resolution. Since the technique is based in TPEF, the method can be extended to deep tissue imaging and has potential applications in single molecule detection, biological sensors, or super-resolution imaging techniques.
- 31 July 2017
- Published by Optica Publishing Group in Optica
- Vol. 4 (8) , 911-918
Open AccessSub-diffraction discrimination with polarization-resolved two-photon excited fluorescence microscopy
Imaging molecular structures separated by distances of a few nanometers still represents a complex challenge. Moreover, it is normally restricted to observations on thin (few micrometers) samples. In this work, we rotate the polarization of the excitation beam of two-photon excited fluorescence (TPEF) images to show that fluorescent structures at the molecular scale can be discriminated in a living organism. The polarization rotation generates a modulation of the signal intensity in each pixel of the TPEF images that carry information related to the fluorophore orientation. We analyze the signal modulation in every pixel of the polarization-resolved (PR) TPEF images through a Fourier analysis and generate images for the different Fourier components. Doing that, we show that two fluorophores oriented in different directions can be distinguished. Although by imaging the Fourier components the resolution of the optical system restricts the exact localization of two close molecules, discrimination is still possible even when the molecules are located at sub-diffraction distances. We propose a model that predicts this behavior, and demonstrate it experimentally in the neurons of a living Caenorhabditis elegans nematode, where we distinguish the walls of an axon with a diameter below the objective resolution. Since the technique is based in TPEF, the method can be extended to deep tissue imaging and has potential applications in single molecule detection, biological sensors, or super-resolution imaging techniques.
- 1 January 2015
- Published by Optica Publishing Group
- p. 954208
Optical spectroscopy for stereotactic biopsy of brain tumors
Stereotactic biopsy procedure is performed to obtain a tissue sample for diagnosis purposes. Currently, a fiber-based mechano-optical device for stereotactic biopsies of brain tumors is developed. Two different fluorophores are employed to improve the safety and reliability of this procedure: The fluorescence of intravenously applied indocyanine green (ICG) facilitates the recognition of blood vessels and thus helps minimize the risk of cerebral hemorrhages. 5-aminolevulinic-acid-induced protoporphyrin IX (PpIX) fluorescence is used to localize vital tumor tissue. ICG fluorescence detection using a 2-fiber probe turned out to be an applicable method to recognize blood vessels about 1.5 mm ahead of the fiber tip during a brain tumor biopsy. Moreover, the suitability of two different PpIX excitation wavelengths regarding practical aspects was investigated: While PpIX excitation in the violet region (at 405 nm) allows for higher sensitivity, red excitation (at 633 nm) is noticeably superior with regard to blood layers obscuring the fluorescence signal. Contact measurements on brain simulating agar phantoms demonstrated that a typical blood coverage of the tumor reduces the PpIX signal to about 75% and nearly 0% for 633 nm and 405 nm excitation, respectively. As a result, 633 nm seems to be the wavelength of choice for PpIX-assisted detection of high-grade gliomas in stereotactic biopsy.
- 1 January 2015
- Published by Optica Publishing Group
- p. 954208
Optical spectroscopy for stereotactic biopsy of brain tumors
Stereotactic biopsy procedure is performed to obtain a tissue sample for diagnosis purposes. Currently, a fiber-based mechano-optical device for stereotactic biopsies of brain tumors is developed. Two different fluorophores are employed to improve the safety and reliability of this procedure: The fluorescence of intravenously applied indocyanine green (ICG) facilitates the recognition of blood vessels and thus helps minimize the risk of cerebral hemorrhages. 5-aminolevulinic-acid-induced protoporphyrin IX (PpIX) fluorescence is used to localize vital tumor tissue. ICG fluorescence detection using a 2-fiber probe turned out to be an applicable method to recognize blood vessels about 1.5 mm ahead of the fiber tip during a brain tumor biopsy. Moreover, the suitability of two different PpIX excitation wavelengths regarding practical aspects was investigated: While PpIX excitation in the violet region (at 405 nm) allows for higher sensitivity, red excitation (at 633 nm) is noticeably superior with regard to blood layers obscuring the fluorescence signal. Contact measurements on brain simulating agar phantoms demonstrated that a typical blood coverage of the tumor reduces the PpIX signal to about 75% and nearly 0% for 633 nm and 405 nm excitation, respectively. As a result, 633 nm seems to be the wavelength of choice for PpIX-assisted detection of high-grade gliomas in stereotactic biopsy.