PKPatrick J. Karas

Patrick J. Karas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Patrick J. Karas has a total of 96 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Weakly Supervised Multiple-Instance Learning for Seizure Onset Zone Identification

    by Junan Mao, Anne-Cecile Lesage, Liliana Camarillo Rodriguez, Diosely C Silveira, Yuanyi Zhang, Patrick J Karas, Jiefei Wang

    Accurate localization of the seizure onset zone (SOZ) is essential for planning resection or ablation in patients with focal drug-resistant epilepsy (DRE). However, the true SOZ cannot be directly observed during clinical evaluation, so precise electrode-level annotations are rarely available. To address this limitation, we developed a weakly supervised multiple-instance learning (MIL) framework in which labels were constructed from electrode resection status and postsurgical outcome. A shared gated recurrent unit (GRU) with temporal attention encoded each electrode’s peri-onset neural fragility sequence. And attention-based pooling integrated information across variable numbers of electrodes to estimate whether each electrode group contained SOZ-related evidence. The cohort comprised 42 patients with DRE from three datasets, including 29 with successful and 13 with failed postsurgical outcomes. These patients contributed 136 seizure epochs. The cohort was divided at the patient level into training, validation and held-out test sets containing 25, 8 and 9 patients, respectively, with all data from each patient retained in the same subset. Predictions from non-resected regions were evaluated at the seizure-epoch and patient levels to assess postsurgical outcome discrimination for individual seizures and after aggregation across seizures from the same patient, respectively. At the seizure-epoch level, the proposed framework achieved an area under the receiver operating characteristic (ROC) curve (AUC) of 0.828, with a 95% confidence interval (CI) of 0.511-1.000, and performed comparably to Manifold Oblique Random Forests (MORF). At the patient level, the framework achieved an AUC of 0.944, with a 95% CI of 0.677-1.000, and yielded a numerically higher AUC than MORF. However, DeLong’s test did not show a statistically significant difference between the methods, with a P value of 0.398. These findings support the feasibility of extracting clinically meaningful SOZ-related information from electrode-wise neural fragility sequences without precise electrode-level labels. Because the held-out test set included only nine patients and the CIs were wide, these preliminary findings require validation in larger independent cohorts.

  • Real-Time Pressure Sensing Is Associated With Reduced Complication Rates in Percutaneous Spinal Cord Lead Implantation: A Retrospective Cohort Analysis

    by Sean O'LEary, Anthony M. Price, Christopher File, Teerth Y. Patel, Nathan Fredricks, Kishan Akash Patel, Anne-Cecile Lesage, Liliana Camarillo-Rodriguez, Christian Ogasawara, Matias Costa, et al.

    BACKGROUND AND OBJECTIVES: CompuFlo provides real-time pressure feedback to identify the epidural space during spinal cord stimulator (SCS) implantation. METHODS: We compared CompuFlo with standard loss of resistance. Single-center retrospective cohort of consecutive SCS implantations by one surgeon using CompuFlo or loss of resistance. Primary outcome: composite of any cerebrospinal fluid leak, epidural blood patch, or postoperative radiculopathy. Secondary outcomes: each component, needle-pass burden (mean passes per electrode; ≥2 passes), operative time, and hospital length of stay (LOS). Models adjusted for age, sex, and entry level. RESULTS: Seventy-nine patients were included (CompuFlo n = 40; standard n = 39). CompuFlo patients were older, with similar sex and race distributions. Entry level differed numerically between groups. Multiple attempts, mean needle passes per electrode, and LOS were similar. In adjusted analyses, CompuFlo guidance was associated with lower odds of any complication (adjusted odds ratio 0.09, 95% CI 0.00-0.90; P = .039). Individual complications, ≥2 passes, pass rate, operative time, and LOS did not differ. Among CompuFlo cases with pressure recordings (n = 19), first-pass high pre-epidural pressures averaged 137.6 ± 8.4 mm Hg and low epidural pressures averaged 20.0 ± 13.6 mm Hg. CONCLUSION: CompuFlo-guided epidural access during SCS implantation was associated with lower adjusted odds of perioperative complications without increased needle-pass burden or LOS. Larger prospective studies are warranted.

  • Open Access

    Integrating data across oscillatory power bands predicts the seizure onset zone in focal epilepsies

    by Sean O’LEary, Anne-Cecile Lesage, Liliana Camarillo-Rodriguez, Oliver Zhou, Diosely C Silveira, Jiefei Wang, Sameer A Sheth, Joshua M Diamond, Michael S Beauchamp, Zhengjia Wang, et al.

    Accurate identification of the seizure onset zone (SOZ) using intracranial electroencephalography (iEEG) remains challenging. Although diverse methods have leveraged spectral features to classify patient outcomes, few approaches focus on identifying individual electrodes within the SOZ or integrate a broad spectrum of frequency ranges within a single model. We developed an interpretable machine learning model that integrates power across delta, theta, alpha, beta, gamma and high-gamma frequencies over time to identify the SOZ. For 1511 electrodes implanted across 21 patients, we computed the mean spectral power in each frequency band for the first 20 s after seizure onset and analysed the differences in power between SOZ and non-SOZ electrodes. In patients who were seizure free after surgery (n = 14), electrodes within the SOZ showed significantly higher area under the curve (AUC) for mean power over time in the first 20 s after seizure onset compared to electrodes outside the SOZ in the alpha (P = 0.0272), beta (P = 0.0263), gamma (P = 0.0013) and high gamma (P = 0.0086) ranges. Additionally, electrodes within the SOZ in patients who became seizure free after surgery had significantly higher AUC compared to equivalent electrodes in patients who did not become seizure free after surgery (n = 7) in the gamma (P = 0.0145) and high gamma (P = 0.0024) power ranges. We trained a stacked random forest ensemble model using these features over time to label electrodes within the SOZ. Leave-one-out patient cross-validation of the machine learning model yielded a 96.6% positive predictive value and 99.9% specificity for identifying electrodes within the SOZ. Our dataset included a diverse array of seizure onset patterns, which were all classified accurately by the model. A second model was trained to predict post-operative seizure freedom, yielding 95.2% accuracy for predicting seizure outcome based on a planned resection. This two-model design mirrors clinical workflow, first localizing SOZ electrodes to support surgical planning and then predicting outcomes based on a surgical plan. An advantage of our interpretable machine learning approach is the ability to interrogate our models to understand how predictions are made. For electrode classification, the model weighed beta (0.66 ± 0.07), high gamma (0.54 ± 0.06) and delta (0.51 ± 0.06) power bands most heavily. Viewing the model’s frequency band weights over time reveals that the model identified a pattern resembling the ‘fingerprint of the epileptogenic zone’, reinforcing the importance of this dominant fundamental neurophysiologic signature of seizure onset.


  • Open Access

    Building an Ecosystem of Seizure Localization Methods: Neural Fragility as the First Step

    by Jiefei Wang, Anne-Cecile Lesage, Oliver Zhou, Ioannis Malagaris, Sean O'LEary, Liliana Camarillo Rodriguez, Diosely C Silveira, Zhengjia Wang, Yuanyi Zhang, Patrick J Karas

    The current treatment for drug-resistant epilepsy (DRE) is surgical intervention, which relies on accurate identification of the seizure onset zone (SOZ) using intracranial EEG (iEEG) data. iEEG analysis with computational epileptogenic zone identification algorithms (CEZIAs) is a promising step towards better SOZ localization and surgical outcomes. A key step in validation and adoption of CEZIAs is to allow for widespread shared development and validation of code and data. We describe a set of three R packages to achieve this goal. Our ecosystem of seizure localization methods involves a straightforward analysis pipeline, standardized data formatting and storage, and completely documented and open-source code. The TableContainer package allows for easy storage and manipulation of table data, serving as groundwork for the Epoch package, which is specifically geared towards iEEG data. The Epoch package allows for cropping, resampling, and visualization of iEEG data and provides publicly downloadable iEEG data for reproducibility. Finally, the EZFragility package uses these two foundational packages to analyze iEEGs for SOZ localization using the Neural Fragility method described by Li et al. EZFragility was built using the same core principles as the original method but included several enhancements in computational efficiency and user experience. It accurately reproduces neural fragility results for both sample patients used in the original paper. This project serves as the first step towards building an open-source, reproducible ecosystem of seizure localization methods in R. Future steps include the addition of other CEZIAs using the framework and sample data already made available by these packages. Significance Statement: Localization of the seizure onset zone (SOZ) is a critical step in surgical treatment of drug-resistant epilepsy. Computational epileptogenic zone identification algorithms (CEZIAs) are promising potential tools to aid in clinical decision-making. However, shared development and verification of CEZIAs is difficult due to obscured source code, variable data structures, and limited data availability. The EZFragility software package 1 is the first step in building a collaborative ecosystem of CEZIAs that can be downloaded, tested, and used without these roadblocks. EZFragility 1 and its dependent packages TableContainer 2 and Epoch 3 are freely available on the Comprehensive R Archive Network (CRAN), with source code viewable on GitHub. They provide an open-source framework for CEZIA code, data formatting, and data access, all with extensive documentation.

  • Risk Factors for Pediatric Intracranial Neoplasms in the Kids’ Inpatient Database

    by Anthony Price, Sean O’lEary, Hannah Parker, Liliana Camarillo-Rodriguez, Adam Husain, Mason Bartman, Ariadna Robledo, Oliver Zhou, Aaron Mohanty, Patrick Karas

    Introduction: In children and adolescents, brain and central nervous system (CNS) tumors are the leading types of cancers. Past studies have found differing rates of intracranial cancers among races and identified additional cancer risk factors. This study aimed to see if these differences can be substantiated with further investigation of the latest version (2019) of the Kids’ Inpatient Database (KID). Methods: A total of 7,818 pediatric patients <21 years old in KID with ICD-10 codes consisting of malignant neoplasms of the brain, brainstem, and cerebral meninges (C700, C709–C719) were queried. Modifiable risk factors evaluated include: hospital region, insurance type, hospital city size, the average income of patient zip code, and location/teaching status of a hospital. Non-modifiable risk factors were race and sex at birth. Dependent variables were tested in Excel and GraphPad Prism 9 using a χ2 test with Yates’ continuity correction and Tukey’s one-way and two-way ANOVAs. Results: Mortality rates of females (2.88%) compared to males (1.99%) were significant (p < 0.05). Mortality was (4.17%) in black patients compared to (1.68%) for white (p < 0.0001), Hispanic mortality (2.95%) compared to white (p < 0.01), and mortality of Asian/Pacific Islander (3.86%) compared to white (p < 0.01). Black patients had significantly higher mortality than white, Hispanic, Asian/Pacific Islander, Native American, and other races overall (p < 0.01). There was no significant difference in the mortality rates between children’s hospitals and large hospitals for any race. After accounting for patient race, mortality was still not significantly different for patients with Medicaid insurance compared to non-Medicaid insurance types. Of the children treated at children’s hospitals, the most transferred in from outside hospitals were Native American (20.00%) followed by Asian/Pacific Islander (15.09%) then Hispanic patients (13.67%). A significant difference between races was also seen regarding length of stay (p < 0.001) and number of charges (p < 0.001). Conclusion: These findings confirm prior studies suggesting gender and race are significant factors in mortality rates for children with intracranial neoplasms. However, the findings do not identify the root causes of these discrepancies but may serve as an impetus for clinicians, healthcare administrators, and governmental leaders to improve national resource allocation to better care for pediatric patients with intracranial neoplasms.

  • Open Access

    Integrating Data Across Oscillatory Power Bands Predicts the Seizure Onset Zone in Focal Epilepsies

    by Sean O’LEary, Anne-Cecile Lesage, Liliana Camarillo-Rodriguez, Oliver Zhou, Diosely C. Silveira, Jiefei Wang, Sameer A. Sheth, Joshua M Diamond, Michael S. Beauchamp, Zhengjia Wang, et al.

    Accurate identification of the seizure onset zone (SOZ) using intracranial electroencephalography (iEEG) remains challenging. Although diverse methods have leveraged spectral features to classify patient outcomes, few approaches focus on identifying individual electrodes within the SOZ or integrate a broad spectrum of frequency ranges within a single model. We developed an interpretable machine learning model that integrates power across delta, theta, alpha, beta, gamma, and high-gamma frequencies over time to identify the SOZ. For 1,511 electrodes implanted across 21 patients, we computed the mean spectral power in each frequency band for the first 20 seconds after seizure onset and analyzed the differences in power between SOZ and non-SOZ electrodes. In patients who were seizure-free after surgery (n = 14), electrodes within the SOZ showed significantly higher area under the curve (AUC) for mean power over time in the first 20 seconds after seizure onset compared to electrodes outside the SOZ in the alpha (p = 0.0272), beta (p = 0.0263), gamma (p = 0.0013), and high gamma (p = 0.0086) ranges. Additionally, electrodes within the SOZ in patients that became seizure-free after surgery had significantly higher AUC compared to equivalent electrodes in patients who did not become seizure-free after surgery (n = 7) in the gamma (p = 0.0145) and high gamma (p = 0.0024) power ranges. We trained a stacked random forest ensemble model using these features over time to label electrodes within the SOZ. Leave-one-out patient cross validation of the machine learning model yielded a 96.6% positive predictive value and 99.9% specificity for identifying electrodes within the SOZ. Our dataset included a diverse array of seizure onset patterns, which were all classified accurately by the model. A second model was trained to predict post-operative seizure freedom, yielding 95.2% accuracy for predicting seizure outcome based on a planned resection. This two-model design mirrors clinical workflow, first localizing SOZ electrodes to support surgical planning, then predicting outcome based on a surgical plan. An advantage of our interpretable machine learning approach is the ability to interrogate our models to understand how predictions are made. For electrode classification, the model weighed beta (0.66 ± 0.07), high gamma (0.54 ± 0.06), and delta (0.51 ± 0.06) power bands most heavily. Viewing the model’s frequency band weights over time reveals that the model identified a pattern resembling the “fingerprint of the epileptogenic zone”, reinforcing the importance of this dominant fundamental neurophysiologic signature of seizure onset.


  • Open Access

    Awake resection of recurrent astroblastoma with intraoperative 5-ALA–induced fluorescence: illustrative case

    by Anthony Price, Sean O’lEary, Kseniia Malkova, Preston D’sOuza, Christian Ogasawara, Michelle M Felicella, Patrick J Karas

    BACKGROUND: Astroblastoma is a rare neoplasm characterized as a circumscribed glial neoplasm most often arising in the frontoparietal cerebral hemispheres in older children. OBSERVATIONS: We report an intriguing case of an astroblastoma recurrence 21 years after gross-total resection and radiation. A 32-year-old right-handed female presented to the emergency department for a generalized tonic-clonic seizure. She had a history of bipolar disorder, intractable migraines, and prior seizures linked to an astroblastoma previously resected three times. Magnetic resonance imaging on the current visit showed growth of the recurrent lesion to a 3.8-cm maximal diameter. Left-sided awake craniotomy was performed to remove the tumor while using speech mapping and 5-aminolevulinic acid (5-ALA). Targeted next-generation sequencing of the tumor revealed in-frame MN1 :: BEND2 fusion transcripts. LESSONS: We found that 5-ALA can be used in astroblastoma patients to assist in gross-total resection, which is important for long-term survival. Our astroblastoma case demonstrated classic astroblastoma morphology, with typical perivascular astroblastic rosettes, and was brightly fluorescent after 5-ALA administration.


  • Open Access

    Neurolymphomatosis of the brachial plexus from atypical primary central nervous system lymphoma lesions: A case report and review of the literature

    by Dominic J. Kizek, Eric A. Goethe, Patrick J. Karas, Jeffrey M. Treiber, Ali Jalali, Shankar P. Gopinath, Joseph S. Kass

    Background: Primary central nervous system lymphoma (PCNSL) is an aggressive and extranodal non-Hodgkin lymphoma limited to the neuroaxis. In immunocompetent individuals, PCNSL is more common in older adults and lacks the association with the Epstein–Barr virus found in individuals with AIDS-associated PCNSL. Because the clinical presentation and radiographic findings of PCNSL are highly variable, stereotactic brain biopsy is typically required for definitive diagnosis. High-dose methotrexate, in combination with other chemotherapeutic agents with or without whole brain radiation, is the mainstay of treatment. Case Description: A 70-year-old HIV-negative woman presented with confusion, acute flaccid left arm weakness, and left hand numbness. Head computed tomography without contrast demonstrated a 1 cm hyperdense round lesion in the suprasellar cistern that prompted further evaluation. Gadolinium-enhanced brain magnetic resonance imaging demonstrated enhancing lesions with heterogeneous signal intensity in the suprasellar, pineal, and right periatrial regions that did not explain the limb weakness and numbness. Serum and cerebrospinal fluid (CSF) studies were unrevealing, and a diagnosis of PCNSL was made following stereotactic biopsy. The patient’s liver cirrhosis precluded chemotherapy, but treatment with whole-brain radiation was pursued. Conclusion: The myriad clinical presentations and insidious course of PCNSL contribute to diagnostic difficulties, delays in treatment, and poor outcomes. Stereotactic brain biopsy is the primary method of PCNSL diagnosis since malignant cells are typically not detected in CSF. PCNSL should be considered in the differential diagnosis when immunocompetent elderly patients present with multiple intracranial lesions, even in the presence of lower motor neuron findings.


  • Commentary: Lactate, the Astrocyte-Neuron Lactate Shuttle, and Neuroprotection in Traumatic Brain Injury

    by Preston D’sOuza, Miranda Hayworth, Brian Oliver, Shankar P. Gopinath, Patrick J. Karas