Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carlos Talayero has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Bow oscillation and its association with shooting accuracy in junior elite recurve archers

    by Carlos Talayero, Ignacio López-Moranchel, Raúl López-González, Raúl Díaz-López, Olga López-Torres

    Introduction and Objective: Bow stability before release is a key determinant of precision, yet its relationship with upper-limb strength in junior elite archers remains under-characterized. This study aimed to quantify triaxial bow oscillation and examine its association with shooting performance and maximal isometric handgrip strength. Methodology: Using an 8-camera Vicon system, 3D kinematics were recorded to evaluate bow displacement and pulling-hand variability during a standardized pre-release window in recurve archers. Results: Longitudinal oscillation was identified as the most consistent kinematic determinant of performance, showing a large negative association with shooting score. A nearly perfect negative correlation was found between mean score and grouping area (minimum enclosing circle method). While handgrip strength was not associated with performance, bow draw force showed a moderate-to-large positive association with score, though it did not reach statistical significance after correction. Conclusions: These findings highlight the critical role of longitudinal stability over raw hand strength in determining shooting precision among elite junior recurve archers.

  • Open Access

    Understanding the Fundamental Properties of Binder Systems Based on Polyethylene and Waxes for the Metal Injection Molding (MIM) Process

    by Alicia Páez-Pavón, Andrea Galán-Salazar, Carlos Talayero, Federico R. García-Galván, Artemia Loayza, Isabel Lado-Touriño

    Binder systems based on polyethylene (PE) and wax are widely used in Metal Injection Molding (MIM). However, their application raises environmental concerns related to material waste and the possible alteration of binder properties during repeated processing. This study aims to provide a comprehensive understanding of the behavior and properties of PE–wax systems to establish a reference framework for the evaluation and future development of alternative binder formulations. Model PE–wax blends without metallic powder were characterized using differential scanning calorimetry, tensile testing, and X-ray diffraction. The results showed that polymer and wax type influence the mechanical response of the blends, with the HDPE–octadecane formulation exhibiting a lower Young’s modulus than the HDPE–paraffin wax blend at the same wax content. Thermal analysis revealed distinct transitions associated with the polymer and wax components, together with small variations between successive heating and cooling cycles, indicating thermal-history-dependent behavior. Young’s modulus, Poisson’s ratio, thermal conductivity, and density were also predicted using Digimat software. The predicted Young’s modulus values showed good agreement with the experimental tensile results. The results provide a preliminary framework for screening polyethylene–wax binder formulations.

  • Open Access

    Power output, blood lactate thresholds, and tricepsbrachii EMG in an elite wheelchair racing athlete: a case study on a roller ergometer

    by Ignacio López-Moranchel, Olga López-Torres, Raúl Díaz-López, Raúl López-González, Carlos Alberto Talayero

    Objective: to examine the concordance between estimated power output, blood lactate concentration, and triceps brachii electromyographic (EMG) activity in a T54 elite athlete during an incremental roller ergometer test; Methods: a female T54 competitor performed a maximal incremental protocol on a calibrated roller ergometer. Surface EMG of the triceps brachii and capillary blood lactate concentration were recorded. Mechanical power was estimated through a coast-down modelling approach; Results: simultaneous inflection points in EMG amplitude and lactate concentration were observed at 20 km/h, coinciding with a steep increase in mechanical demand; Discussion: the strong agreement between estimated mechanical output and internal physiological markers reinforces the potential of roller-based assessments for identifying neuromuscular and metabolic thresholds during upper-limb propulsion tasks; Conclusions: indirect power estimation on roller ergometers provides a valid and accessible alternative for individualized load prescription in adapted sport, supporting the integration of physiological testing tools into performance monitoring of athletes with disabilities

  • Open Access

    Cost-effective power assessment in paralympic wheelchair athletes

    by Carlos Talayero, Ignacio López-Moranchel, Raúl Díaz-López, Olga López-Torres

    Introduction: power measurement in sports is essential to enhance performance, but technological and economic limitations hinder its application in Paralympic contexts. Objective: to develop and validate a power estimation method for wheelchair athletes, particularly during training on roller benches, without the need for expensive devices. Methodology: coast-down tests were carried out on track and roller bench at different speeds (10, 15 and 20 km/h), measuring stopping distance and acceleration. Drag force, power, and handrim effort were calculated using vehicle dynamics equations. Results: track values deviated only 3.8% from accelerometer data, validating the method. On roller benches, values matched those of track up to 12 km/h; at higher speeds, aerodynamic resistance caused noticeable deviations. Discussion: findings align with previous studies on rolling resistance and wheelchair dynamics. The methodology allows realistic representation of effort during training. Conclusions: a cost-effective and reliable solution for power estimation in Paralympic athletes is provided, with direct applications in training planning.

  • Open Access

    Interfacial Shear Strength of Single-Walled Carbon Nanotubes-Cement Composites from Molecular Dynamics and Finite Element Studies

    by Carlos Talayero, Isabel Lado-Touriño, Omar Aït-Salem, Ismael Sánchez Ramos, Alicia Páez-Pavón, Rosario G. Merodio-Perea

    Carbon nanotubes (CNTs) are nanometer-sized structures that can be used to reinforce cement matrices. The extent to which the mechanical properties are improved depends on the interfacial characteristics of the resulting materials, that is, on the interactions established between the CNTs and the cement. The experimental characterization of these interfaces is still impeded by technical limitations. The use of simulation methods has a great potential to give information about systems lacking experimental information. In this work, molecular dynamics (MD) and molecular mechanics (MM) were used in conjunction with finite element simulations to study the interfacial shear strength (ISS) of a structure formed by a pristine single-walled CNT (SWCNT) inserted in a tobermorite crystal. The results show that, for a constant SWCNT length, ISS values increase when the SWCNT radius increases, while for a constant SWCNT radius, shorter lengths enhance ISS values.


  • Open Access

    Mechanical Properties of Cement Reinforced with Pristine and Functionalized Carbon Nanotubes: Simulation Studies

    by Rosario G. Merodio-Perea, Isabel Lado-Touriño, Alicia Páez-Pavón, Carlos Talayero, Andrea Galán-Salazar, Omar Aït-Salem

    Concrete is well known for its compression resistance, making it suitable for any kind of construction. Several research studies show that the addition of carbon nanostructures to concrete allows for construction materials with both a higher resistance and durability, while having less porosity. Among the mentioned nanostructures are carbon nanotubes (CNTs), which consist of long cylindrical molecules with a nanoscale diameter. In this work, molecular dynamics (MD) simulations have been carried out, to study the effect of pristine or carboxyl functionalized CNTs inserted into a tobermorite crystal on the mechanical properties (elastic modulus and interfacial shear strength) of the resulting composites. The results show that the addition of the nanostructure to the tobermorite crystal increases the elastic modulus and the interfacial shear strength, observing a positive relation between the mechanical properties and the atomic interactions established between the tobermorite crystal and the CNT surface. In addition, functionalized CNTs present enhanced mechanical properties.


  • Open Access

    Computational Prediction and Experimental Values of Mechanical Properties of Carbon Nanotube Reinforced Cement

    by Carlos Talayero, Omar Aït-Salem, Pedro Gallego, Alicia Páez-Pavón, Rosario G. Merodio-Perea, Isabel Lado-Touriño

    The main objective of this study is to create a rigorous computer model of carbon nanotube composites to predict their mechanical properties before they are manufactured and to reduce the number of physical tests. A detailed comparison between experimental and computational results of a cement-based composite is made to match data and find the most significant parameters. It is also shown how the properties of the nanotubes (Young’s modulus, aspect ratio, quantity, directionality, clustering) and the cement (Young’s modulus) affect the composite properties. This paper tries to focus on the problem of modeling carbon nanotube composites computationally, and further study proposals are given.


  • Open Access

    Modeling of blood clot removal with aspiration Thrombectomy devices

    by G. Romero, C. Talayero, G. Pearce, J. Wong

    Thrombectomy by aspiration is a highly effective method of accomplishing vessel recanalization. This study aims to obtain a mathematical model that allows the prediction of the dynamic response of a thrombus in response to different suction conditions, in order to avoid potential damage or the breakage of the clot during the interventional procedure. Virtual computing models have been created using Bond-Graph data and mass-spring Multi-Degree of Freedom equations. The model allows the use of tensile and torsion loads that could potentially be generated by the suction pressure together with different catheter geometries. The stress generated in the clot depends on its length and on its stiffness. The results obtained with the mathematical model are validated with a Finite Element Method (FEM) model, shows good agreement in terms of stress and elongation values. The results are consistent with previous Bond Graph models which indicated that the forces needed to extract a blood clot from an artery in in-vitro experiments are within the range used experimentally (~40-90 kPa). Qualitative experiments are undertaken with 3D printed scale prototypes and gelatin. The results are consistent with Computer Fluid Dynamic (CFD) simulations.


  • Open Access

    Thrombectomy aspiration device geometry optimization for removal of blood clots in cerebral vessels

    by C. Talayero, G. Romero, G. Pearce, J. Wong

    A study involving the removal of blood clots in cerebral vessels by aspiration thrombectomy is presented. A robust design for the distal end geometry of a catheter is obtained that, together with adequate suction conditions, could avoid potential damage in the artery or fragmentation the thrombus. The optimization process of the parameters is undertaken by a Design of Experiments (DOE) that has been prepared based on Robust Design theories. In particular, 27 experiments are run for one factor at 9 levels (catheter geometry) and up to 9 factors at 3 levels. The experiments are formulated with virtual models that are solved with computing tools. Co-simulation between Computer Fluid Dynamics (CFD) and Finite Elements Method (FEM) structural analysis was used to obtain the suction conditions and the behavior of the blood clot during the intervention process. By comparing the results of the 27 experiments, the highest values of the suctioning force are obtained for a hole pattern based catheter design, that also gives the lowest risk for clot damage (based on the stress value obtained). Direct aspiration and designs based on conical catheter distal ends, give less robust solutions (results are not stable when the conditions of the environment change). Our study investigated the distance between the catheter and the clot, and it was noted that if the catheter was far from the clot, the suction generated a vessel narrowing and consequent potential damage. Up to 90 kPa could be applied when suctioning at a maximum distance equal to the diameter of the vessel between the distal end of the catheter and the proximal end of the clot. A maximum suctioning force of 0,514N was achieved without damage to the artery or the clot. This research enables us to determine and use the most representative parameters and geometries to be tested in in-vitro and in-vivo experiments. In this virtual study, hypothesizes are assumed with regard to the material properties, but the robustness of the design process allows to expect similar results in future in-vitro and in-vivo tests.