ASAlexander Yu. Shimolin

Alexander Yu. Shimolin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexander Yu. Shimolin has a total of 64 co-authors. Here are the top co-authors by number of shared publications:

  • Alena V. Sobina

    UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology

    5 shared publications
  • Egor P. Sobina

    UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology

    4 shared publications
  • A. V. Sobina

    UNIIM - Affiliated Branch of the D.I. Mendeleev Institute for Metrology

    3 shared publications
  • F Gonca Coskun

    13 TÜBITAK UME - Ulusal Metroloji Enstitüsü, Barış Mah. Dr. Zeki Acar Cad. No 1, 41470 Gebze-Kocaeli, Turkey

    2 shared publications
  • Ma Liandi

    NIM - National Institute of Metrology P. R. China, No 18, Bei San Huan Dong Lu, Chaoyang District, 100029 Beijing, P. R. China

    2 shared publications
  • Shi Naijie

    NIM - National Institute of Metrology P. R. China, No 18, Bei San Huan Dong Lu, Chaoyang District, 100029 Beijing, P. R. China

    2 shared publications

Latest Publications

  • Open Access

    Development of a Reference Material for Potassium Bromide Composition

    by A. V. Sobina, E. P. Sobina, A. Yu. Shimolin

    To obtain reliable measurement results for the content of components in various materials, reference materials with certified content of the studied component are required. Elemental bromine, being a volatile and toxic liquid, is unsuitable as a source material for the preparation of a reference material for the chemical element bromine. The most optimal choice for the reference material is a bromine salt – potassium bromide.The aim of the study is to develop a certified reference material for composition of potassium bromide based on the same high-purity salt with the certified characteristic «mass fraction of potassium bromide». The mass fraction of the main component in potassium bromide was measured using two methods: a direct method employing coulometric titration with corrections for interfering impurities determined by ion chromatography, and an indirect method based on the scheme of 100% minus the sum of impurities, taking into account their ionic forms.It is shown that the direct and indirect methods for determining the mass fraction of potassium bromide yield consistent results: (99.871 ± 0.029) and (99.873 ± 0.017)%, respectively. Studies of homogeneity, as well as short-term and long-term stability, were conducted using the coulometric titration. A reference material for potassium bromide composition, GSO 12300-2023, was developed with an interval of certified values of the mass fraction of potassium bromide (99.5–100)% and an expanded uncertainty of the certified value of 0.05% at k=2. The certified value and expanded uncertainty of the mass fraction of potassium bromide for a batch of the reference material were (99.87 ± 0.05)%.A distinctive feature of the indirect method for determining the mass fraction of potassium bromide implemented in this work is the construction of a chemical composition model of the analyzed object. This model is based on both a priori and experimental data and utilizes two fundamental principles when summing impurity contents: the condition of material (mass) balance and the principle of electroneutrality. The described indirect method is sufficiently universal. For high-purity salts, it enables achieving a relative expanded uncertainty (at k=2) of less than 0.02%. This method can be adopted in analytical practice for assessing the purity of other metal salts where high accuracy is required.The developed certified reference material can be used to ensure the metrological traceability of measurement results in both titrimetry (precipitation titration) and elemental analysis. It can also be utilized for the preparation or control of certified values for reference materials of bromide ion solution composition, including those in multicomponent mixtures with other anions.

  • Final report of CCQM-K96.2023.1: assay of potassium dichromate

    by Kyungmin Jo, Min-Ah Oh, Alena Sobina, Alexandr Shimolin

    Main text: The CCQM key comparison CCQM-K96.2023.1, a subsequent comparison to CCQM-K96.2023, was conducted to demonstrate the capability of VNIIM-UNIIM to measure the amount content of oxidants. KRISS served as the coordinating laboratory, with its results linking to the original comparison. Participating institutes may use a method of their choice, but coulometry with potentiometric or amperometric endpoint determination is expected to be used in most cases. The results from VNIIM-UNIIM were in good agreement with the reference value, providing evidence to support the respective CMC claims. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  • CCQM-K161 "Anions in Seawater"

    by Chao Jingbo, Ma Liandi, Shi Naijie, Li Yunqiao, Chen Yan, Dong Lijie, Zhou Yuanjing, Patricia Grinberg, Zoltan Mester, Enea Pagliano, et al.

    Main text: Anions or nutrients in seawater are very important targets for oceanographic research and environmental monitoring of contaminations. Quantification of minor and trace anions in seawater has always been a challenge for the extremely high salinity, disparate levels of analyte and matrix ions, and even need to be measured at levels close to the detection limits of the method performance. Evidence of successful participation in formal, relevant international comparisons is needed to support calibration and measurement capability claims (CMCs) made by the national metrology institutes (NMIs) and designated institutes (DIs). The CCQM-K161 Anions in Seawater was organized by the Inorganic Analysis Working Group (IAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) to assess the abilities of the NMIs and DIs for the accurate determination of minor and trace anions in seawater. The measurands covered chloride (16 mg/g-25 mg/g), sulfate (1 mg/g-4 mg/g), bromide (30 mg/kg-100 mg/kg), nitrate (1 mg/kg-5 mg/kg) and phosphate (60 µg/kg-300 µg/kg). Twelve national metrology institutes and designated institutes participated in this key comparison. Participants were requested to evaluate the mass fractions, expressed in mg/g for chloride and sulfate, mg/kg for bromide and nitrate, and µg/kg for phosphate (as phosphorus) in a mixed natural seawater that was spiked with the phosphate. A variety of techniques including isotope dilution inductively coupled plasma mass spectrometry (IDMS), isotope dilution gas chromatography-mass spectrometry (ID-GC-MS), ion chromatography (IC), UV visible spectrophotometry (UV-Vis), flow injection analysis (FIA) was used by the participants for the determination. The NIST Decision Tree was used to assign the KCRV estimate and to calculate the degrees of equivalence of each participants following the IAWG Guidance on Using NIST Decision Tree for Comparison Reporting from 30 June 2023. Successful participation in CCQM-K161 demonstrates measurement capabilities for determination of anions in seawater. Considering the IAWG Core Capability Matrix, this material falls into the matrix challenge called 'High salts content', which corresponds to the CCQM amount-of-substance category sea water, and so will support CMCs for the anions in a mass fraction range from 60 µg/kg to 25 mg/g. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Developing a Potassium Iodate Reference Material: Evaluating Salt Purity Using Direct and Indirect Approaches

    by A. V. Sobina, E. P. Sobina, A. Y. Shimolin, T. N. Tabatchikova

    The mass fraction of the main component is determined in potassium iodate by a direct method (coulometric titration with control of interfering impurities by ion chromatography) and an indirect method (by subtracting the sum of impurities taking into account their forms of presence from 100%). Both direct and indirect methods give consistent results: 99.966 ± 0.014 and 99.976 ± 0.010%, respectively. The measurement results, considering uncertainty, are consistent with the key comparison reference value of the mass fraction of potassium iodate, 99.980 ± 0.006%. The value was obtained with the same material used in the international key comparison CCQM-K152 Assay of Potassium Iodate, which involved national metrological institutes from seven countries. The indirect method for determining the mass fraction of potassium iodate, implemented in this work, is distinguished by the development of a model of the chemical composition of the test sample based on a priori and experimental data using two basic principles in summing up the impurity content: the conditions of material (mass) balance and the principle of electrical neutrality. A high-precision reference material of the composition of potassium iodate GSO 11713-2021 has been developed with a range of certified values for the mass fraction of potassium iodate of 99.000–100.000%, iodine of 59.242–59.301%, oxygen of 22.406–22.429%, and expanded uncertainty of certified values at k = 2 of 0.020−0.030%.

  • Open Access

    Caffeine Quantification Via High-Precision Coulometric Titration

    by A. Yu. Shimolin

    Caffeine has traditionally been used to assess and control the metrological characteristics of liquid chromatographs. In recent years, with increasing requirements for the traceability of measurement results, the use of caffeine as a reagent for verification, calibration, and type approval tests has started to contradict the effective regulations governing measurement uniformity. This study aims to develop and test a procedure of caffeine quantification in caffeine via primary coulometric titration for the metrological support of high-performance liquid chromatography (HPLC) with an accuracy of no more than 1 % abs. In the course of work, a detailed analysis of methods for determining caffeine content in various matrices was carried out; in addition, a procedure for determining caffeine mass fraction in caffeine via coulometric titration was developed and tested. A comparison of the obtained results with caffeine mass fraction measurements performed using HPLC confirmed the commutativity of coulometric titration and HPLC. The developed procedure of caffeine quantification in caffeine via primary coulometric titration employing GET 176 can be used to develop a caffeine composition reference material and to provide metrological traceability of HPLC measurements on its basis to state primary standards reproducing the «mass fraction of components» and to SI units (Systeme international d’unites, SI).

  • Open Access

    Application of direct and indirect methods for determining the mass fraction of the main component in flotation potassium chloride

    by E. P. Sobina, A. V. Sobina, A. Yu. Shimolin, T. N. Tabatchikova, E. L. Lebedeva, P. V. Migal’, M. P. Krasheninina

    The article is devoted to the comparison of two approaches to determining the purity of metal salts on the example of a complex in composition object - flotation potassium chloride. The results of determining the mass fraction of the main component (potassium chloride) in flotation potassium chloride obtained by direct (using the coulometric titration method with correction for anions titrated with the determined chloride ion and an excess of cations) and indirect (according to the scheme 100% minus the amount of impurities with regard to their species) methods. It is shown that direct and indirect methods give well consistent results: (96.08 ± 0.17) % and (96.11 ± 0.12) %, respectively. Also, the measurement results obtained using the standard installations considering the uncertainty are well consistent with the certified value of the mass fraction of potassium chloride (96.11 ± 0.11) %, obtained based on an interlaboratory experiment in laboratories that perform measurements in accordance with GOST 20851.3. The feature of the direct and indirect methods implemented in this work is the construction of a model of the chemical composition of the analysed object based on a priori and experimental data using two basic principles when summing up the content of impurities: the conditions of material balance and the principle of electroneutrality.


  • Report of the CCQM-K152. Assay of potassium iodate

    by Alena Sobina, Alexandr Shimolin, Egor Sobina, Tatyana Tabatchikova, José Luis Ortiz-Aparicio, Judith Velina Lara-Manzano, Paulo Paschoal Borges, Rodrigo de Santis Neves, Sidney Pereira Sobral, Rodrigo Caciano de Sena, et al.

    Main text: The CCQM-K152 key comparison in parallel with CCQM-P192 pilot comparison were organised jointly by the Inorganic Analysis (IAWG) and Electrochemical Analysis and Classical Chemical methods (EAWG) working groups of CCQM to test the abilities of the metrology institutes to measure the amount content of the non-metallic elements in high purity salts as well as assaying high purity salts to be used as primary standards. Eight NMIs participated in the key comparison CCQM-K152. Ural Research Institute for Metrology (UNIIM) (since 2020 it has been called Affiliated Branch of D.I.Mendeleev Institute for Metrology (VNIIM-UNIIM)), Russian Federation, acted as the coordinating laboratory of the comparison. There were two measurands: the amount content of oxidants expressed as potassium iodate, mol/kg, and the mass fraction of iodine, kg/kg. The measurement methods used by participants for the amount content of oxidants expressed as potassium iodate were constant current coulometry and titrimetry. For the mass fraction of iodine results were provided by 5 NMIs, 3 of them used the direct approach (recalculation from coulometric or titrimetric results) and 2 NMIs implemented the indirect approach based on impurities assessment using combination of the instrumental methods (ion chromatography, ICP OES, ICP MS). In general, good overlap of results was observed for both measurands. Direct and indirect approaches for purity determination of pure salt provide overlapping results when impurities are summarized in ionic form. The suitability of coulometry for assay of high purity materials was demonstrated again, and some possible technical problems were highlighted. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).