Qingwen Mou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qingwen Mou has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Wei Gu
Jiangsu Provincial Key Laboratory of Smart Grid Technology & Equipment, Southeast University, Nanjing, 210096, China
3 shared publications- Xing Liu
Department of Electrical Engineering, School of Automation, Nanjing University of Science & Technology, Nanjing, 210094, China
3 shared publications Puyu Wang
Department of Electrical Engineering, School of Automation, Nanjing University of Science & Technology, Nanjing, 210094, China
2 shared publicationsChen Du
Jiangsu Frontier Electric Technology Co., Ltd., Nanjing 211102, Jiangsu Province, China
1 shared publication- Puyu Wang
School of Automation, Nanjing University of Science & Technology (NUST), Nanjing 210094, China
1 shared publication Xiaozheng Tang
Maintenance Branch, State Grid Jiangsu Electric Power Co., Ltd, Nanjing, 211100, China
1 shared publication
Latest Publications
- Open Access
- 12 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 176921-176934
Start-Up Control and Grid Integration Characteristics of 300 MVar Synchronous Condenser With Voltage Sourced Converter-Based SFC
Synchronous condenser (SC) is generally used as the devices for reactive power support for the ultra-high-voltage direct current (UHVDC) transmission at the receiving end. When a SC is started, it will have a large surge on the interconnected system and the SC itself. In severe cases, it will endanger the operation of SC and related equipment. The start-up control of a 300 MVar SC using voltage source converter (VSC)-based static frequency converter (SFC) is proposed in this paper. Dynamic behaviors of interconnected system during the start-up period with three different criterions of grid integration constraint of the SC, including initial falling speed, frequency difference and phase difference, are analyzed. Firstly, topological structure and control strategy of the VSC-based SFC are proposed. Secondly, a mathematical model of the SFC-based SC is established. The surge of the start-up and grid integration of the SC with three different constraint criterions on the interconnected system is analyzed in sequence. Thirdly, a simulation system of a 300 MVar SC with VSC-based SFC is established in the time-domain simulation software PSCAD/EMTDCTM. Dynamic behaviors and surge of the overall system with different criterions of grid integration constraint are demonstrated and studied. Finally, a comprehensive starting control strategy of the SC with optimized initial falling speed, optimized frequency difference and optimized phase difference is proposed based on the theoretical analysis and simulation experiments. Simulation results justify the effectiveness of the start-up and grid integration control strategy proposed.
- 12 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 176921-176934
Open AccessStart-Up Control and Grid Integration Characteristics of 300 MVar Synchronous Condenser With Voltage Sourced Converter-Based SFC
Synchronous condenser (SC) is generally used as the devices for reactive power support for the ultra-high-voltage direct current (UHVDC) transmission at the receiving end. When a SC is started, it will have a large surge on the interconnected system and the SC itself. In severe cases, it will endanger the operation of SC and related equipment. The start-up control of a 300 MVar SC using voltage source converter (VSC)-based static frequency converter (SFC) is proposed in this paper. Dynamic behaviors of interconnected system during the start-up period with three different criterions of grid integration constraint of the SC, including initial falling speed, frequency difference and phase difference, are analyzed. Firstly, topological structure and control strategy of the VSC-based SFC are proposed. Secondly, a mathematical model of the SFC-based SC is established. The surge of the start-up and grid integration of the SC with three different constraint criterions on the interconnected system is analyzed in sequence. Thirdly, a simulation system of a 300 MVar SC with VSC-based SFC is established in the time-domain simulation software PSCAD/EMTDCTM. Dynamic behaviors and surge of the overall system with different criterions of grid integration constraint are demonstrated and studied. Finally, a comprehensive starting control strategy of the SC with optimized initial falling speed, optimized frequency difference and optimized phase difference is proposed based on the theoretical analysis and simulation experiments. Simulation results justify the effectiveness of the start-up and grid integration control strategy proposed.
- Open Access
- 9 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 146914-146921
Start-Up Control of a Synchronous Condenser Integrated HVDC System With Power Electronics Based Static Frequency Converter
The operation of thyristor-based high-voltage direct current (HVDC) system requires abundant reactive power support. Synchronous condensers, as rotating devices with large capacity of reactive power compensation, are generally utilized in HVDC systems. In this paper, the start-up control of a synchronous condenser integrated HVDC system with power electronics based static frequency converter (SFC) is investigated with the following 3 contributions: (1) Three different variable frequency starting methods are proposed regarding the main start-up control component, SFC. (2) Dynamic behaviors of AC voltages, reactive power of the system are studied when the synchronous condenser is integrated into the HVDC with different start-up control methods. An evaluation index, including successive rates of integration, reactive power surges, and lengths of start-up period, are established using different start-up control methods. (3) Synthesizing the characteristics of three different start-up control methods, an optimized variable frequency starting control is proposed and the control strategy is further developed. A simulation model of a synchronous condenser integrated HVDC system with an SFC is established in PSCAD/EMTDC. Simulation results justify the effectiveness and superiority of the optimized start-up control strategy proposed.
- 9 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 146914-146921
Open AccessStart-Up Control of a Synchronous Condenser Integrated HVDC System With Power Electronics Based Static Frequency Converter
The operation of thyristor-based high-voltage direct current (HVDC) system requires abundant reactive power support. Synchronous condensers, as rotating devices with large capacity of reactive power compensation, are generally utilized in HVDC systems. In this paper, the start-up control of a synchronous condenser integrated HVDC system with power electronics based static frequency converter (SFC) is investigated with the following 3 contributions: (1) Three different variable frequency starting methods are proposed regarding the main start-up control component, SFC. (2) Dynamic behaviors of AC voltages, reactive power of the system are studied when the synchronous condenser is integrated into the HVDC with different start-up control methods. An evaluation index, including successive rates of integration, reactive power surges, and lengths of start-up period, are established using different start-up control methods. (3) Synthesizing the characteristics of three different start-up control methods, an optimized variable frequency starting control is proposed and the control strategy is further developed. A simulation model of a synchronous condenser integrated HVDC system with an SFC is established in PSCAD/EMTDC. Simulation results justify the effectiveness and superiority of the optimized start-up control strategy proposed.
- Open Access
- 16 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 104121-104131
Dynamic Behaviors and Protection Strategy of Synchronous Condenser Integrated Power System Under Non-Full Phase Fault Conditions
When a synchronous condenser connected power network encounters a non-full phase fault, the amplitude of the stator current is severely suppressed by the magnetic field generated inside the synchronous condenser, in which the sensitivity of failure protection of circuit breakers are affected resulting in rejection of failure protection. In severe cases, it may endanger the secure and stable operation of the synchronous condenser and the related equipment. In this paper, dynamic behaviors of a synchronous condenser without/with de-excitation action under non-full phase faults are investigated with the following four contributions: 1) A mathematical model under non-full phase fault conditions is established. The theoretical value of fault currents is calculated when the synchronous condenser is without/with de-excitation action. 2) The inferiority/superiority without/with de-excitation action is analyzed. The tendency of dynamic behaviors of variables, including the phase current, negative-sequence, and zero-sequence currents, after de-excitation action, is obtained. A selection criterion of failure protection is proposed according to the dynamic behaviors of negative- and zero-sequence currents. 3) Based on the consistent characteristics of the theoretical calculation, simulations in PSCAD/EMTDC and recorded on-site data from WaveEx, the fact that the simulation model established in PSCAD/EMTDC can provide an effective verification platform for practical applications and data analysis of a synchronous condenser integrated power grid under non-full phase faults is justified. 4) An improved operational threshold of failure protection of circuit breakers is proposed. It can reduce the rejection operation probability of failure protection, which improves the protection sensitivity and enhances the security of the system operation. The simulation results justify the necessity and reliability of the criterion setting proposed for failure protection.
- 16 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 104121-104131
Open AccessDynamic Behaviors and Protection Strategy of Synchronous Condenser Integrated Power System Under Non-Full Phase Fault Conditions
When a synchronous condenser connected power network encounters a non-full phase fault, the amplitude of the stator current is severely suppressed by the magnetic field generated inside the synchronous condenser, in which the sensitivity of failure protection of circuit breakers are affected resulting in rejection of failure protection. In severe cases, it may endanger the secure and stable operation of the synchronous condenser and the related equipment. In this paper, dynamic behaviors of a synchronous condenser without/with de-excitation action under non-full phase faults are investigated with the following four contributions: 1) A mathematical model under non-full phase fault conditions is established. The theoretical value of fault currents is calculated when the synchronous condenser is without/with de-excitation action. 2) The inferiority/superiority without/with de-excitation action is analyzed. The tendency of dynamic behaviors of variables, including the phase current, negative-sequence, and zero-sequence currents, after de-excitation action, is obtained. A selection criterion of failure protection is proposed according to the dynamic behaviors of negative- and zero-sequence currents. 3) Based on the consistent characteristics of the theoretical calculation, simulations in PSCAD/EMTDC and recorded on-site data from WaveEx, the fact that the simulation model established in PSCAD/EMTDC can provide an effective verification platform for practical applications and data analysis of a synchronous condenser integrated power grid under non-full phase faults is justified. 4) An improved operational threshold of failure protection of circuit breakers is proposed. It can reduce the rejection operation probability of failure protection, which improves the protection sensitivity and enhances the security of the system operation. The simulation results justify the necessity and reliability of the criterion setting proposed for failure protection.