DODaniel Ourinson

Daniel Ourinson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daniel Ourinson has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Microstructure Analysis of Current‐Fired Contacts on TOPCon Layers

    by Johannes M. Greulich, Cyril Leon, Sebastian Mack, Daniel Ourinson, Jonas D. Huyeng, Stefan Rein

    We report on the analysis of the microstructure of a current‐fired contact formed by screen printing, drying, and sintering of a silver paste and subsequent laser‐enhanced contact optimization (LECO) for silicon solar cells with tunnel‐oxide passivated contacts (TOPCon) on the TOPCon side. The analysis is based on scanning electron microscopy and energy dispersive X‐ray spectroscopy. We show that a new phase is formed during LECO at individual points of the interface between the contact finger and the polycrystalline silicon layer consisting of silver and silicon. The altered material combination is confined to the metal and the polycrystalline layer only and does not penetrate through the tunnel oxide into the silicon wafer. We conclude that the mechanism for the contact formation on the TOPCon stack is very similar to the one reported for the front contact of passivated emitter and rear cells.


  • Open Access

    Faster firing processes up to 20 m/min belt velocity

    by Daniel Ourinson, Gernot Emanuel, Mohammad Abazid, Sebastian Nold, Dirk Eberlein, Florian Clement

    This work successfully demonstrates fast firing processes with a technical throughput of 13204 cells/h for M2- sized solar cells (assumption of a double-lane fu


  • Open Access

    Short Drying Processes for Silicon Solar Cells

    by Daniel Ourinson, Michael Linse, Markus Klawitter, Andreas Lorenz

    Herein, very short drying processes for the screen‐printed electrodes of passivated emitter and rear solar cells (PERC) are successfully demonstrated. The short drying processes are conducted in an in‐line heating system with vertical‐cavity surface‐emitting lasers (VCSEL) as its heat source, being a compact alternative to the conventional heating chamber. While the heating time of the conventional industrial drying process is believed to be about 20 s (to the best of the authors’ knowledge), the VCSEL system allows a significant reduction down to 0.15 s while maintaining a similar power conversion efficiency and contact adhesion quality.


  • Laser-Powered Co-Firing Process for Highly Efficient Si Solar Cells

    by Daniel Ourinson, Gernot Emanuel, Kaveh Rahmanpour, Felix Ogiewa, Harald Muller, Eve Krassowski, Hannes Hoffler, Florian Clement, Stefan W. Glunz

    This article presents a successful laser-powered co-firing process for highly efficient Si solar cells as a more compact and energy-efficient alternative to the conventional firing process in an infrared (IR) lamp-powered heat chamber. The best cell group reaches with laser firing only 0.1%abs lower cell efficiency compared to the best group with conventional firing, demonstrating the industrial potential of this laser firing technology. Adding the laser enhanced contact optimization (LECO) process after firing improves the cell efficiency for laser firing to the level of conventional firing, demonstrating the potential of the combination of the laser firing and the LECO process.


  • Spatially Resolved Determination of Metallization-Induced Recombination Losses Using Photoluminescence Imaging

    by David Herrmann, David R. C. Falconi, Sabrina Lohmuller, Daniel Ourinson, Andreas Fell, Hannes Hoffler, Andreas Arnold Brand, Andreas Wolf

    Metallization induced recombination losses are one dominant loss mechanism for current industrial solar cells. A precise determination of these losses is important for contacting technology optimization, as well as precise solar cell modeling. Usually, for state-of-the-art approaches to determine j $_{0,\text{met}}$ , it is assumed that the samples itself exhibit spatially uniform properties (e.g., carrier lifetime or sheet resistance) or that the used reference samples are identical to the metallized samples. Finally, in most cases, only one global j $_{0,\text{met}}$ -value for the entire sample is given, neglecting possible spatial inhomogeneities. In this article, we mostly eliminate the necessity for the assumptions of perfect sample homogeneity by means of an interpolation scheme of the photoluminescence (PL) signal. Thereby, we can predict the PL signal of a virtually nonmetallized test field with a relative standard deviation of about σ ≈ 0.7%. Additionally, we determine j $_{0,\text{met}}$ for specific test fields at different positions on the sample and correlate the results to the local emitter sheet resistance R $_{\text{sh}}$ , the local peak firing temperature of the sample during the fast firing process T $_{\text{peak}}$ , and the test field finger spacing d. For our samples, a reduction of d from d = 1000 μm to d = 200 μm leads to a reduction of j $_{0,\text{met}}$ by up to 18%. This strong effect is physically unexpected and so far not considered by the state-of-the-art approach, frequently performed in the photovoltaic community. Further, we perform a sensitivity and error analysis which reveals that we are able to determine j $_{0,\text{met}}$ within an estimated accuracy between 15% and 18%.


  • In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography

    by Daniel Ourinson, Gernot Emanuel, Gunnar Dammaß, Harald Müller, Florian Clement, Stefan W. Glunz

    Measuring the surface temperature of objects that are processed in conveyor belt furnaces is an important tool in process control and quality assurance. Currently, the surface temperature of objects processed in conveyor belt furnaces is typically measured via thermocouples. However, infrared (IR) thermography presents multiple advantages compared to thermocouple measurements, as it is a contactless, real-time, and spatially resolved method. Here, as a representative proof-of-concept example, an inline thermography system is successfully installed into an IR lamp powered solar firing furnace, which is used for the contact firing process of industrial Si solar cells. This protocol describes how to install an IR camera into a conveyor belt furnace, conduct a customer correction of a factory calibrated IR camera, and perform the evaluation of spatial surface temperature distribution on a target object.


  • In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography

    by Daniel Ourinson, Gernot Emanuel, Gunnar Dammaß, Harald Müller, Florian Clement, Stefan W. Glunz

    This protocol describes how to install an infrared camera into a conveyor belt furnace, conduct a customer correction of a factory calibrated IR camera, and evaluate the spatial surface temperature distribution of an object of interest. The example objects are industrial silicon solar cells.


  • Optimization of Al Fire-Through Contacts for AlOX–SiNX Rear Passivated Bifacial p-PERC

    by Daniel Ourinson, Tobias Fellmeth, Sebastian Tepner, Tayyab Javaid, Marwan Dhamrin, Caitlin Turney, Gernot Emanuel, Stefan W. Glunz, Maximilian Pospischil, Florian Clement

    We present optimizations of rear Al fire-through (FT) contacts for bifacial p-type passivated emitter and rear (AlO $_{\rm X}$ –SiN $_{\rm X}$ ) cells. This approach allows omitting the laser contact opening step. Prior to this work, high FT lateral resistance due to its glass frit, and high rear surface recombination due to large passivation damage and back surface field layer (BSF) abscence, decreased the cell performance for cells with Al FT contacts. In this work, a proper BSF has been achieved by adapting the firing process and by printing multilayer fingers. Achievement of increased BSF thickness and reduced rear contact area—by means of dashing or finger narrowing by dispensing (down to 70 μm)—seems to close the gap to the non-FT (NFT) reference level in terms of contact recombination. This is indicated by reaching similar open-circuit voltages for rear-side-only fired (front side plated) cells. For cofired cells, open-circuit voltages were 6 mV below NFT level, stemming most likely from an overfired front side contact due to firing process adaptations. Multilayer printing allows for a decrease of the lateral resistance of the less conductive FT grid due to an increase of the finger cross-sectional area. For best rear-side-only fired FT cells, reduced recombination and resistance closed the efficiency (η) gap to the NFT reference. For the best cofired FT cells, η $\approx$ 21.3% and bifacial power output density of $P_{\beta\_{\rm OUT}}$ $\approx$ 22.8 mW/cm2 is achieved compared to η $\approx$ 21.5% and $P_{\beta\_{\rm OUT}}$ $\approx$ 23.1 mW/cm2 for NFT. The remaining $P_{\beta\_{\rm OUT}}$ gap has the potential to be reduced by the means of mitigating front side contact overfiring by matching thermal tolerance of the front side paste, and reducing rear side finger resistivity by paste optimization.


  • Open Access

    In Situ Solar Wafer Temperature Measurement during Firing Process via Inline IR Thermography

    by Daniel Ourinson, Gernot Emanuel, Attila Csordás, Gunnar Dammaß, Harald Müller, Christoph Sternkiker, Florian Clement, Stefan W. Glunz

    Herein, an inline IR thermography system as an innovative application for real‐time contactless temperature measurement of wafers—both metallized and nonmetallized—during the firing process is successfully realized in an industrial firing furnace as proof of concept and example for a thermography system in a conveyor furnace. As observed by the new system, thermocouples (TCs) seem to measure lower temperature on wafers—especially in combination with TC frames—than wafers exhibit at standard firing conditions (here up to ΔT ≈ 40 K). Furthermore, highly resolved spatial temperature distribution can be successfully measured on the wafer.