Bahador Fani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bahador Fani has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Iman Sadeghkhani
Smart Microgrid Research Center, Najafabad Branch Islamic Azad University Najafabad Iran
14 shared publications - Ghazanfar Shahgholian
Department of Electrical Engineering, Najafabad Branch Islamic Azad University Najafabad Iran
10 shared publications - Majid Delshad
Department of Electrical Engineering, Isfahan (Khorasgan) Branch Islamic Azad University Isfahan Iran
7 shared publications Majid Delshad
6 shared publications- Majid Moazzami
Department of Electrical Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran
6 shared publications Hadi Bisheh
Smart Microgrid Research Center, Najafabad Branch Islamic Azad University Najafabad Iran
5 shared publications
Latest Publications
- Open Access
- 15 November 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 183
Bifurcation analysis of targeted false data injection attack in islanded AC microgrids: Revealing the dynamic mechanism of voltage flicker
- 15 November 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 183
Open AccessBifurcation analysis of targeted false data injection attack in islanded AC microgrids: Revealing the dynamic mechanism of voltage flicker
- 21 October 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Selective fault current limiting for fuse saving coordination in solar photovoltaic-rich distribution networks
- 21 October 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Selective fault current limiting for fuse saving coordination in solar photovoltaic-rich distribution networks
- Open Access
- 1 January 2026
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2026 (1)
Adaptive Virtual Impedance‐Based Volt‐Var Control in Standalone AC Microgrids: An Overview
In inductive microgrids, there is no guarantee for installing distributed generation units at regular intervals. Consequently, impedance mismatch and reactive power sharing errors are inevitable. The virtual impedance adaptive droop control method identifies impedance mismatches as disturbances and compensates for impedance imbalance by calculating a nonphysical compensating‐impedance value, thereby achieving ideal reactive power sharing according to prevailing conditions. This control approach can be implemented in both centralized and decentralized patterns according to network capacity utilization. From an architectural perspective, the decentralized structure can be classified into two types: fully decentralized control and pseudodecentralized control. Certainly, independence from communication infrastructures is an important factor for validating the comparison of these two structures. This paper attempts to review adaptive virtual impedance droop control by comparing the differences, similarities, and approaches of these two infrastructures. Finally, this paper mainly investigates the impact of small‐signal analysis on AVI control in fully decentralized and pseudodecentralized structures, and the findings are presented accordingly.
- 1 January 2026
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2026 (1)
Open AccessAdaptive Virtual Impedance‐Based Volt‐Var Control in Standalone AC Microgrids: An Overview
In inductive microgrids, there is no guarantee for installing distributed generation units at regular intervals. Consequently, impedance mismatch and reactive power sharing errors are inevitable. The virtual impedance adaptive droop control method identifies impedance mismatches as disturbances and compensates for impedance imbalance by calculating a nonphysical compensating‐impedance value, thereby achieving ideal reactive power sharing according to prevailing conditions. This control approach can be implemented in both centralized and decentralized patterns according to network capacity utilization. From an architectural perspective, the decentralized structure can be classified into two types: fully decentralized control and pseudodecentralized control. Certainly, independence from communication infrastructures is an important factor for validating the comparison of these two structures. This paper attempts to review adaptive virtual impedance droop control by comparing the differences, similarities, and approaches of these two infrastructures. Finally, this paper mainly investigates the impact of small‐signal analysis on AVI control in fully decentralized and pseudodecentralized structures, and the findings are presented accordingly.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Real‐Time Cyber‐Attack Detection and Adaptive Recovery in Islanded AC Microgrids Using a Fourth‐Order Backward‐Difference Predictor and Teager–Kaiser Energy Operator
Although islanded microgrids offer significant operational autonomy, their lack of external voltage and frequency references and absence of a global supervisory structure make them highly vulnerable to cyber‐attacks. Timely and accurate detection of such attacks is a critical prerequisite for maintaining microgrid stability and resilience. This paper presents a computationally efficient technique for real‐time detection and adaptive recovery of islanded AC microgrids against false data injection (FDI) and denial‐of‐service (DoS) attacks. Unlike complex machine learning‐ and observer‐based techniques, the proposed technique integrates a fourth‐order backward difference‐based predictor with the Teager–Kaiser energy operator (TKEO). Local frequency deviations are first estimated with high accuracy, generating a residual signal that is subsequently amplified by TKEO and assessed through an attack detection index (ADI). The key innovation lies in coupling this detection mechanism with an adaptive recovery scheme, which updates the communication adjacency matrix weights to isolate compromised links and restore network stability without prior knowledge of microgrid topology, attack type or location. Extensive simulations on an islanded IEEE 34‐bus test feeder demonstrate that the proposed technique achieves a high detection accuracy of 98.6% with a delay below 0.5 s. Moreover, it remains robust against measurement uncertainties, severe noise and typical microgrid disturbances such as sudden load changes and capacitor/reactor switching, while ensuring compatibility with diverse communication infrastructures. These results highlight the technique's effectiveness, resilience and practical applicability for next‐generation cyber‐secure microgrids.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Open AccessReal‐Time Cyber‐Attack Detection and Adaptive Recovery in Islanded AC Microgrids Using a Fourth‐Order Backward‐Difference Predictor and Teager–Kaiser Energy Operator
Although islanded microgrids offer significant operational autonomy, their lack of external voltage and frequency references and absence of a global supervisory structure make them highly vulnerable to cyber‐attacks. Timely and accurate detection of such attacks is a critical prerequisite for maintaining microgrid stability and resilience. This paper presents a computationally efficient technique for real‐time detection and adaptive recovery of islanded AC microgrids against false data injection (FDI) and denial‐of‐service (DoS) attacks. Unlike complex machine learning‐ and observer‐based techniques, the proposed technique integrates a fourth‐order backward difference‐based predictor with the Teager–Kaiser energy operator (TKEO). Local frequency deviations are first estimated with high accuracy, generating a residual signal that is subsequently amplified by TKEO and assessed through an attack detection index (ADI). The key innovation lies in coupling this detection mechanism with an adaptive recovery scheme, which updates the communication adjacency matrix weights to isolate compromised links and restore network stability without prior knowledge of microgrid topology, attack type or location. Extensive simulations on an islanded IEEE 34‐bus test feeder demonstrate that the proposed technique achieves a high detection accuracy of 98.6% with a delay below 0.5 s. Moreover, it remains robust against measurement uncertainties, severe noise and typical microgrid disturbances such as sudden load changes and capacitor/reactor switching, while ensuring compatibility with diverse communication infrastructures. These results highlight the technique's effectiveness, resilience and practical applicability for next‐generation cyber‐secure microgrids.
- Open Access
- 1 January 2026
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2026 (1) , 9317966
A High Voltage Gain Single‐Switch Converter With Soft‐Switching and EMI Mitigation
In this study, a high step‐up DC–DC conversion topology incorporating soft‐switching behavior is introduced. The proposed structure employs a combination of coupled‐inductor boosting and switched‐capacitor enhancement to achieve a substantial increase in voltage gain. A passive energy‐recovery clamp is integrated into the design to alleviate the negative effects of leakage inductance and recycle the stored energy. By adopting this configuration, the main switch naturally satisfies soft‐switching requirements, achieving zero‐current switching at turn‐on and zero‐voltage switching at turn‐off, which significantly minimizes switching losses and improves overall efficiency. The converter uses only a single active semiconductor device along with one magnetic core, resulting in a compact and economically attractive solution. Additionally, the input and output terminals share a common ground, improving system‐level compatibility and simplifying implementation. Grounding the switch source further reduces the complexity of the gate‐drive circuitry. To substantiate the analytical evaluation, a 200‐W prototype was constructed and tested, demonstrating the practical viability of the proposed converter. The experimental results reveal a maximum efficiency of 95.6% at full load, while maintaining conducted EMI levels below 59 dB μ V, thereby meeting the CISPR 22 Class B requirements.
- 1 January 2026
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2026 (1) , 9317966
Open AccessA High Voltage Gain Single‐Switch Converter With Soft‐Switching and EMI Mitigation
In this study, a high step‐up DC–DC conversion topology incorporating soft‐switching behavior is introduced. The proposed structure employs a combination of coupled‐inductor boosting and switched‐capacitor enhancement to achieve a substantial increase in voltage gain. A passive energy‐recovery clamp is integrated into the design to alleviate the negative effects of leakage inductance and recycle the stored energy. By adopting this configuration, the main switch naturally satisfies soft‐switching requirements, achieving zero‐current switching at turn‐on and zero‐voltage switching at turn‐off, which significantly minimizes switching losses and improves overall efficiency. The converter uses only a single active semiconductor device along with one magnetic core, resulting in a compact and economically attractive solution. Additionally, the input and output terminals share a common ground, improving system‐level compatibility and simplifying implementation. Grounding the switch source further reduces the complexity of the gate‐drive circuitry. To substantiate the analytical evaluation, a 200‐W prototype was constructed and tested, demonstrating the practical viability of the proposed converter. The experimental results reveal a maximum efficiency of 95.6% at full load, while maintaining conducted EMI levels below 59 dB μ V, thereby meeting the CISPR 22 Class B requirements.
- 21 February 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 244
A decentralized intelligent protection coordination scheme in distribution systems with electric vehicle integration
- 21 February 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 244
A decentralized intelligent protection coordination scheme in distribution systems with electric vehicle integration
- Open Access
- 22 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 18 (1)
Efficient high step‐down converter with soft switching and minimal components
This paper presents a novel two‐switch high step‐down converter based on the conventional Ćuk converter. The proposed converter features lower gain and higher efficiency due to reduced switching and conduction losses. Notably, it enables zero current switching turn‐on for switches without requiring additional components, enhancing its efficiency. The low voltage stress on the switches significantly impacts efficiency. Additionally, its simple topology reduces the component count, further improving efficiency. Zero current switching turn‐off condition for the diode effectively addresses reverse recovery problem. To validate its performance, a prototype operating at 200 W output power, 300 V input voltage, 24 V output voltage, and 40 kHz switching frequency is implanted.
- 22 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 18 (1)
Open AccessEfficient high step‐down converter with soft switching and minimal components
This paper presents a novel two‐switch high step‐down converter based on the conventional Ćuk converter. The proposed converter features lower gain and higher efficiency due to reduced switching and conduction losses. Notably, it enables zero current switching turn‐on for switches without requiring additional components, enhancing its efficiency. The low voltage stress on the switches significantly impacts efficiency. Additionally, its simple topology reduces the component count, further improving efficiency. Zero current switching turn‐off condition for the diode effectively addresses reverse recovery problem. To validate its performance, a prototype operating at 200 W output power, 300 V input voltage, 24 V output voltage, and 40 kHz switching frequency is implanted.
- Open Access
- 1 January 2025
- Published by Wiley in International Journal of Energy Research
- Vol. 2025 (1)
Multiobjective Probabilistic Planning of Energy Hub With Hydrogen Storage Technologies Considering Demand Response Programs
This paper develops a stochastic bi‐objective energy management system (EMS) for an integrated energy hub (EH) comprising photovoltaic (PV) arrays, wind turbines (WTs), a dual‐fuel boiler, combined heat and power (CHP) generation, electric vehicle (EV) charging infrastructure, and hydrogen storage systems, interconnected with the main grid. The proposed EMS framework simultaneously minimizes operational expenditures (OPEX) and carbon emissions while addressing uncertainties in renewable generation and load demand through probabilistic modeling and demand response programs (DRPs). A novel modified multi‐objective grasshopper optimization algorithm (MMOGOA) with adaptive mutation operators is introduced to solve this complex optimization problem, demonstrating superior convergence characteristics and 7.2% lower OPEX compared to conventional MOEAs (Non‐dominated Sorting Genetic Algorithm [NSGA‐II] and MOPSO) in baseline scenarios. Comprehensive simulations reveal that demand response program (DRP) implementation achieves significant reductions (18.87% in costs and 14.62% in emissions), while uncertainty incorporation increases costs by 10% and emissions by 4.38%, with MMOGOA consistently maintaining performance dominance across all operational regimes. The results quantitatively highlight the importance of optimizing DRP participation and managing uncertainties to improve the efficiency and sustainability of energy management systems (EMSs).
- 1 January 2025
- Published by Wiley in International Journal of Energy Research
- Vol. 2025 (1)
Open AccessMultiobjective Probabilistic Planning of Energy Hub With Hydrogen Storage Technologies Considering Demand Response Programs
This paper develops a stochastic bi‐objective energy management system (EMS) for an integrated energy hub (EH) comprising photovoltaic (PV) arrays, wind turbines (WTs), a dual‐fuel boiler, combined heat and power (CHP) generation, electric vehicle (EV) charging infrastructure, and hydrogen storage systems, interconnected with the main grid. The proposed EMS framework simultaneously minimizes operational expenditures (OPEX) and carbon emissions while addressing uncertainties in renewable generation and load demand through probabilistic modeling and demand response programs (DRPs). A novel modified multi‐objective grasshopper optimization algorithm (MMOGOA) with adaptive mutation operators is introduced to solve this complex optimization problem, demonstrating superior convergence characteristics and 7.2% lower OPEX compared to conventional MOEAs (Non‐dominated Sorting Genetic Algorithm [NSGA‐II] and MOPSO) in baseline scenarios. Comprehensive simulations reveal that demand response program (DRP) implementation achieves significant reductions (18.87% in costs and 14.62% in emissions), while uncertainty incorporation increases costs by 10% and emissions by 4.38%, with MMOGOA consistently maintaining performance dominance across all operational regimes. The results quantitatively highlight the importance of optimizing DRP participation and managing uncertainties to improve the efficiency and sustainability of energy management systems (EMSs).
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2025 (1)
Single‐Switch High Step‐Up Quasi‐Z‐Source DC‐DC Converter With Low Switch Voltage Stress
High step‐up converters are commonly utilized to manage voltage level between the DC‐bus and low voltage input. The properties such as high‐voltage gain, continuous input current and low switch voltage stress are important for proper performance. The method of coupled inductors is applied to the boost topology in the recent papers to extend voltage gain. Although this method can increase voltage gain, the discontinuous input current is the main drawback. The switched capacitor is another scheme used to increase the voltage gain which usually led the converters to suffer from the high component count. In this paper, a high step‐up converter is presented by integration of switched capacitor and coupled inductors with quasi‐z‐source structure to maintain the continuous input current. A switched capacitor along with a pair of coupled inductors are utilized to enhance voltage gain and switch voltage stress. Also, zero current switching for switch at turn‐on and for all diodes at turn‐off reduce reverse recovery problem. A passive clamp circuit is utilized to absorb the leakage inductance energy, and improve voltage gain by placing the clamp capacitor in the charge path of the switched capacitor. Also, the main properties of quasi‐z‐source converter such as common ground between the output and input sides along with continuous input current is maintained. Additionally, these features are realized by proper component count in comparison with other related topologies based on quasi‐z‐source topology. The experimental results are extracted by a prototype circuit implemented at 300 W and 100 kHz to confirm the theoretical results and the proposal converter operation.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2025 (1)
Open AccessSingle‐Switch High Step‐Up Quasi‐Z‐Source DC‐DC Converter With Low Switch Voltage Stress
High step‐up converters are commonly utilized to manage voltage level between the DC‐bus and low voltage input. The properties such as high‐voltage gain, continuous input current and low switch voltage stress are important for proper performance. The method of coupled inductors is applied to the boost topology in the recent papers to extend voltage gain. Although this method can increase voltage gain, the discontinuous input current is the main drawback. The switched capacitor is another scheme used to increase the voltage gain which usually led the converters to suffer from the high component count. In this paper, a high step‐up converter is presented by integration of switched capacitor and coupled inductors with quasi‐z‐source structure to maintain the continuous input current. A switched capacitor along with a pair of coupled inductors are utilized to enhance voltage gain and switch voltage stress. Also, zero current switching for switch at turn‐on and for all diodes at turn‐off reduce reverse recovery problem. A passive clamp circuit is utilized to absorb the leakage inductance energy, and improve voltage gain by placing the clamp capacitor in the charge path of the switched capacitor. Also, the main properties of quasi‐z‐source converter such as common ground between the output and input sides along with continuous input current is maintained. Additionally, these features are realized by proper component count in comparison with other related topologies based on quasi‐z‐source topology. The experimental results are extracted by a prototype circuit implemented at 300 W and 100 kHz to confirm the theoretical results and the proposal converter operation.