ZNZsofia Nagy

Zsofia Nagy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zsofia Nagy has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Zoltan Som

    Gottsegen National Cardiovascular Center

    3 shared publications
  • Attila Kardos

    Department of Cardiology, Translational Cardiovascular Research Group, Milton Keynes University Hospital NHS Foundation Trust , 8H Standing Way, Eaglestone, Milton Keynes MK6 5LD

    2 shared publications
  • Csaba Földesi

    Gottsegen National Cardiovascular Center , Budapest

    2 shared publications
  • Tamás Breuer

    Department of Cardiology, Gottsegen Gyorgy Hungarian Institute of Cardiology, Haller Street 29, Budapest, 1096, Hungary

    2 shared publications
  • Tamás Géczy

    Thoraxcenter, Department of Clinical Electrophysiology, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000, CA, Rotterdam, The Netherlands

    2 shared publications
  • Zsuzsanna Kis

    Department of Cardiology, Gottsegen Gyorgy Hungarian Institute of Cardiology, Haller Street 29, Budapest, 1096, Hungary

    2 shared publications

Latest Publications

  • Open Access

    Pulmonary vein isolation for atrial fibrillation using high-power short-duration radiofrequency or second-generation cryoballoon ablation: comparison of postprocedural lesion size, left atrial function and myocardial injury

    by Krisztian Kassa, Zsofia Nagy, Daniel Simkovits, Zsuzsanna Kis, Tamas Ferenci, Zoltan Som, Csaba Foldesi, Attila Kardos

    Introduction: Left atrial (LA) lesion size, function and tissue damage have not been compared following pulmonary vein isolation (PVI) by high-power short-duration (HPSD) radiofrequency (RF) and second-generation cryoballoon (CB2) ablation. Methods: We enrolled 40 patients with paroxysmal atrial fibrillation who underwent PVI by HPSD RF (n=21) or CB2 (n=19). Every patient underwent LA CT angiography and transthoracic echocardiography (TTE) to assess LA anatomy and function. Biomarker levels (hs-cTnT, hs-CRP, LDH) were compared pre-and postprocedurally. Pre- and postablation high-density mapping (HDM) was performed. Isolation area was defined under 0.2 mV bipolar voltage (low voltage area, LVA). We calculated the post-PVI LVA/LA surface ratio using LA CT-HDM merge images. At 3-month follow-up, TTE was performed to assess changes in LA function. Results: Postablation hs-cTnT level was significantly higher in the RF group (RF: 1249 ± 469 ng/L, CB2: 995 ± 280 ng/L, p=0.024). Post-PVI hs-CRP (RF: 9.53 ± 10.30 mg/L, CB2: 12.36 ± 5.76 mg/L, p=0.034) and LDH levels (RF: 349.9 ± 65.6 U/L, CB2: 451.6 ± 91.3 U/L, p <0.001) were significantly higher following CB2 ablation. Post-PVI LVA/LA surface ratios were 8.37 ± 6.42% in the RF group and 13.58 ± 8.92% in the CB2 group (p=0.022). LA function did not change significantly by TTE after the PVI procedure. Conclusions: Our data indicate that second-generation cryoballoon ablation produces significantly larger LA lesion size compared with ”point-by-point” HPSD radiofrequency. Both techniques preserve LA function. The myocardial component of tissue loss appears to be higher using HPSD radiofrequency ablation, with less collateral damage.

  • Prospective evaluation of iatrogenic atrial septal defect after cryoballoon or radiofrequency catheter ablation of atrial fibrillation—“EVITA” study

    by Zsofia Nagy, Zsuzsanna Kis, Tamás Géczy, Andras Temesvari, Zoltan Som, Sarolta Borbas, Tamás Breuer, David Molnar, Csaba Foldesi, Attila Kardos

    Iatrogenic atrial septal defect (IASD) after catheter ablation (CA) for atrial fibrillation (AF) due to transseptal puncture (TSP) can occur. The aim of this prospective study was to describe the incidence of IASD and to detect any cerebrovascular accident (CVA) after radiofrequency (RF) and cryoballoon (CB) CA. Between July 2014 and September 2016, 94 patients (pts) (RF; 48, CB; 46, 30 (31.9%) women, mean age = 60 ± 9.7 years) with paroxysmal AF were enrolled who underwent CA procedure for the first time. During RF ablation a single (n = 30, 62.5%) or double (n = 18, 37.5%) TSP was performed. Transoesophageal echocardiography before the procedure and at the 3-month and 12-month follow-up (FU) was accomplished. During the FU period, we evaluated the occurrence of any postprocedural CVA. At the 3-month FU, IASD was detected in 17/94 (18.1%) pts; in 9/48 (18.8%) pts in the RF while in 8/46 (17.4%) pts in the CB group (p = 0.866), all of them with left-to-right shunt. In the RF group, 6/30 (20%) pts with a single TSP while 3/18 (16.7%) pts in the double TSP group had IASD (p = 0.780). 14/17 (82.4%) IASDs showed high spontaneous closure rate at the 12-month FU. None of the pts died or suffered from CVA. Persistent IASD can occur rather frequently following AF CA. No significant difference was observed between the RF and CB techniques concerning the presence of IASD at 3-month. IASDs showed a high spontaneous closure rate. No cerebral thromboembolic event was observed in the 12-month FU period.


  • Open Access

    P365Persistent iatrogenic atrial septal defect after radiofrequency or cryoballoon ablation for paroxysmal atrial fibrillation

    by Z. Nagy, Z. Kis, Z. Som, T. Geczy, C. Foldesi, A. Temesvari, A. Kardos

    Background: Pulmonary vein isolation (PVI) is an effective treatment option for patients with symptomatic drug-refractory paroxysmal atrial fibrillation (AF). During the ablation procedures, transseptal (TS) puncture is needed to access the left-sided heart. In case of a radiofrequency ablation (RF) procedure, left atrial access is commonly achieved with a double transseptal puncture. While, during cryoballoon ablation (CB) a single transseptal puncture is performed with a larger diameter sheath. The ablation technique can affect the incidence of postprocedural iatrogenic atrial septal defect (IASD).

  • Open Access

    176-16: Persistent iatrogenic atrial septal defect after pulmonary vein isolation for paroxysmal atrial fibrillation; a prospective single center study

    by Attila Kardos, Zsuzsanna Kis, Tamás Breuer, Tamas Geczy, Zsófia Nagy, Zoltan Som, András Temesvári, Csaba Földesi

    Background: Pulmonary vein isolation (PVI) is an effective treatment of atrial fibrillation. Persistent iatrogen septal defects (iASD) after transseptal puncture (TS) for PVI has already been reported. However its relation to the method of PVI (radiofrequency [RF] vs. cryoballon [CB] ablation) is not known. We compared prospectively the incidence of iASD between conventional RF and CB ablation. Methods and results: In this prospective study, 43 patients (male/female: 30/11, age: 39–70 years) with symptomatic paroxysmal atrial fibrillation were treated with PVI as an index procedure using RF with double-transseptal (19 pts), or CB with single transseptal approach (24 pts) to access the left atrium. During RF ablation two 8,5 Fr sheaths are placed in the left atrium, whereas one 12 Fr sheath is introduced for CB ablation. Before the procedure ASD was ruled out by transoesophageal echocardiography (TOE). 3 months after PVI TOE was performed, in case when iASD was detected, TOE was repeated after 1 year. Regular follow-up was performed (3, 6, 12 months). The duration of procedure was longer in the RF group (102.5 ± 12 vs. 64 ±14 min, p < 0.05). An iASD was detected in 7pts ( 2 RF and 5 CB pts) at 3-month FU (16% of all pts). At 12-month follow up the repeated TEE showed no permanent IASD in the RF group while 3 iASDs were detected in the CB group (6.9% of all). Mean IASD diameter was similar (0.2 cm × 0.3 cm in RF and 0.3 cm × 0.3 cm in CB). Only left to right atrial shunt was observed. Major complication, paradox embolism was not detected. Conclusions: We found more iASD 3 and 12 month after PVI procedure in the CB group than in the RF group, the incidence was low. Clinical symptoms or major complications related to iASD were not recorded.