Yuchen Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuchen Jia has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Limin Huo
College of Mechanical and Electrical Engineering, Hebei Agricultural University, Baoding 071000, China; Key Laboratory of Broiler/Layer Breeding Facilities Engineering, Ministry of Agriculture and Rural Affairs, Baoding 071000, China; Hebei Provincial Key Laboratory of Livestock and Poultry Breeding Intelligent Equipment and New Energy Utilization, Baoding 071000, China
5 shared publications - Lihua Li
College of Mechanical and Electrical Engineering, Hebei Agricultural University, Baoding 071001, China
4 shared publications Hao Xue
College of Mechanical and Electrical Engineering, Hebei Agricultural University, Baoding 071000, China; Key Laboratory of Broiler/Layer Breeding Facilities Engineering, Ministry of Agriculture and Rural Affairs, Baoding 071000, China; Hebei Provincial Key Laboratory of Livestock and Poultry Breeding Intelligent Equipment and New Energy Utilization, Baoding 071000, China
3 shared publications- Peng Wen
College of Mechanical and Electrical Engineering, Hebei Agricultural University, Baoding 071000, China; Key Laboratory of Meat and Layer Breeding Facilities Engineering, Ministry of Agriculture and Rural Affairs, Baoding 071000, China; Hebei Provincial Key Laboratory of Livestock and Poultry Breeding Intelligent Equipment and New Energy Utilization, Baoding 071000, China
3 shared publications Guandong Gao
Department of Information Management, The National Police University for Criminal Justice, Baoding, Hebei Province, China
2 shared publicationsKe Xiao
2 shared publications
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (23) , 58194-58213
A Multimodule Geometry-Aware Adaptive DV-Hop Localization Algorithm for Anisotropic IoT-Enabled Wireless Sensor Networks
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (23) , 58194-58213
A Multimodule Geometry-Aware Adaptive DV-Hop Localization Algorithm for Anisotropic IoT-Enabled Wireless Sensor Networks
- Open Access
- 14 November 2026
- Published by Elsevier in Energy Reports
- Vol. 16
Bi-level multi-objective optimal scheduling and multi-mechanism interaction-effect evaluation for integrated energy systems with coordinated hydrogen utilization
- 14 November 2026
- Published by Elsevier in Energy Reports
- Vol. 16
Open AccessBi-level multi-objective optimal scheduling and multi-mechanism interaction-effect evaluation for integrated energy systems with coordinated hydrogen utilization
- Open Access
Stackelberg Dispatch of an Integrated Energy System with Ammonia Co-Firing and Closed-Loop Carbon Responsibility Feedback
This study addresses coal-fired unit retrofitting, multi-energy carbon responsibility tracing, and operator–user interdependence in low-carbon economic dispatch of integrated energy systems. A model integrates a coal-fired power plant (CFPP), carbon capture system (CCS), power-to-ammonia (P2A), and combined cooling unit (ACC). It covers ammonia production, storage and co-firing, cooling using residual energy, and CO2 capture, utilization and storage. A multi-objective Stackelberg game between the operator and aggregated users embeds a carbon responsibility closed loop, incorporating dynamic responsibility transfer, internal user carbon settlement, and integrated demand response. Electricity and gas loads respond to energy prices and additional carbon costs through price elasticity. User cost optimization shifts and curtails heating and cooling loads. A bilevel interactive method combines the non-dominated sorting whale optimization algorithm (NSWOA) and Gurobi with blockwise carbon coordination and strict closed-loop verification. The technique for order preference by similarity to ideal solution (TOPSIS) selects a representative solution. Under the specified typical-day conditions, the scenario comparisons show that joint operation improves the operator’s objective by approximately 15%, reduces system carbon emissions by approximately 5%, and lowers primary energy consumption by over 10%. Carbon responsibility feedback further reduces emissions, primary energy consumption, and user costs in this case study. The model translates responsibility into user-side price signals and coordinates operator–user decisions.
Open AccessStackelberg Dispatch of an Integrated Energy System with Ammonia Co-Firing and Closed-Loop Carbon Responsibility Feedback
This study addresses coal-fired unit retrofitting, multi-energy carbon responsibility tracing, and operator–user interdependence in low-carbon economic dispatch of integrated energy systems. A model integrates a coal-fired power plant (CFPP), carbon capture system (CCS), power-to-ammonia (P2A), and combined cooling unit (ACC). It covers ammonia production, storage and co-firing, cooling using residual energy, and CO2 capture, utilization and storage. A multi-objective Stackelberg game between the operator and aggregated users embeds a carbon responsibility closed loop, incorporating dynamic responsibility transfer, internal user carbon settlement, and integrated demand response. Electricity and gas loads respond to energy prices and additional carbon costs through price elasticity. User cost optimization shifts and curtails heating and cooling loads. A bilevel interactive method combines the non-dominated sorting whale optimization algorithm (NSWOA) and Gurobi with blockwise carbon coordination and strict closed-loop verification. The technique for order preference by similarity to ideal solution (TOPSIS) selects a representative solution. Under the specified typical-day conditions, the scenario comparisons show that joint operation improves the operator’s objective by approximately 15%, reduces system carbon emissions by approximately 5%, and lowers primary energy consumption by over 10%. Carbon responsibility feedback further reduces emissions, primary energy consumption, and user costs in this case study. The model translates responsibility into user-side price signals and coordinates operator–user decisions.
- 25 June 2025
- Published by Elsevier in Measurement
- Vol. 256
Research on k-redeployment strategy and nodes scheduling method of sensors in key areas of electrical equipment
- 25 June 2025
- Published by Elsevier in Measurement
- Vol. 256
Research on k-redeployment strategy and nodes scheduling method of sensors in key areas of electrical equipment
- Open Access
- 10 May 2025
- Published by Elsevier in Poultry Science
- Vol. 104 (9) , 105281
Progress and trends of non-contact detection methods for poultry growth information: A review
- 10 May 2025
- Published by Elsevier in Poultry Science
- Vol. 104 (9) , 105281
Open AccessProgress and trends of non-contact detection methods for poultry growth information: A review
- Open Access
- 4 January 2025
- Published by Elsevier in Poultry Science
- Vol. 104 (2) , 104771
Research on virtual collection method of layer house temperature for the construction requirements of digital twin system
- 4 January 2025
- Published by Elsevier in Poultry Science
- Vol. 104 (2) , 104771
Open AccessResearch on virtual collection method of layer house temperature for the construction requirements of digital twin system
- Open Access
Modeling and Regulation of Dynamic Temperature for Layer Houses Under Combined Positive- and Negative-Pressure Ventilation
The environmental control of layer houses with multi-tiered cage systems is influenced by factors such as the structure of the henhouses and the heat dissipation of the flock, leading to low precision and large fluctuations in temperature control. Based on a new combined positive- and negative-pressure ventilation (CPNPV) mode, a dynamic temperature model is constructed. Additionally, a temperature control method for a layer house is designed using a variable universe fuzzy PID control algorithm (VFPID). First, based on the principles of energy and mass balance, and by decoupling the relationship between positive- and negative-pressure ventilation volumes, a dynamic temperature model for layer houses under CPNPV was established. Then, the PID parameters and the proportional relationship between positive- and negative-pressure ventilation were optimized through fuzzy rules, and a proportional exponential function was introduced to adjust the scaling of the universe, enabling fine-tuned control. Finally, a temperature control model for the layer house was built using Simulink. The results show that the coefficients of determination (R2) of the constructed dynamic temperature models are between 0.79 and 0.88, respectively, indicating high accuracy. The designed VFPID method outperformed traditional on–off control and improved control precision by 20–23.53% and 10.34–22.22% compared with PID control and fuzzy PID(FPID) control methods, respectively. This study provides new insights for the development of environmental control equipment and precise environmental regulation of layer houses.
Open AccessModeling and Regulation of Dynamic Temperature for Layer Houses Under Combined Positive- and Negative-Pressure Ventilation
The environmental control of layer houses with multi-tiered cage systems is influenced by factors such as the structure of the henhouses and the heat dissipation of the flock, leading to low precision and large fluctuations in temperature control. Based on a new combined positive- and negative-pressure ventilation (CPNPV) mode, a dynamic temperature model is constructed. Additionally, a temperature control method for a layer house is designed using a variable universe fuzzy PID control algorithm (VFPID). First, based on the principles of energy and mass balance, and by decoupling the relationship between positive- and negative-pressure ventilation volumes, a dynamic temperature model for layer houses under CPNPV was established. Then, the PID parameters and the proportional relationship between positive- and negative-pressure ventilation were optimized through fuzzy rules, and a proportional exponential function was introduced to adjust the scaling of the universe, enabling fine-tuned control. Finally, a temperature control model for the layer house was built using Simulink. The results show that the coefficients of determination (R2) of the constructed dynamic temperature models are between 0.79 and 0.88, respectively, indicating high accuracy. The designed VFPID method outperformed traditional on–off control and improved control precision by 20–23.53% and 10.34–22.22% compared with PID control and fuzzy PID(FPID) control methods, respectively. This study provides new insights for the development of environmental control equipment and precise environmental regulation of layer houses.
- Open Access
CFD Investigation on Combined Ventilation System for Multilayer-Caged-Laying Hen Houses
Mechanical ventilation is an important means of environmental control in multitier laying hen cages. The mainstream ventilation mode currently in use, negative-pressure ventilation (NPV), has the drawbacks of a large temperature difference before and after adjustment and uneven air velocity distribution. To solve these problems, this study designed and analyzed a combined positive and negative-pressure ventilation system for laying hen cages. According to the principle of the conservation of mass to increase the inlet flow in the negative-pressure ventilation system on the basis of the addition of the pressure-wind body-built positive-and-negative-pressure-combined ventilation (PNCV) system, further, computational fluid dynamics (CFD) simulation was performed to analyze the distribution of environmental parameters in the chicken cage zone (CZ) with inlet angles of positive-pressure fans set at 45°, 90°, and 30°. Simulation results showed that the PNCV system increased the average air velocity in the CZ from 0.94 m/s to 1.04 m/s, 1.28 m/s, and 0.99 m/s by actively blowing air into the cage. The maximum temperature difference in the CZ with the PNCV system was 2.91 °C, 1.80 °C, and 3.78 °C, which were all lower than 4.46 °C, the maximum temperature difference in the CZ with the NPV system. Moreover, the relative humidity remained below 80% for the PNCV system and between 80% and 85% for the NPV system. Compared with the NPV system, the PNCV system increased the vertical airflow movement, causing significant cooling and dehumidifying effects. Hence, the proposed system provides an effective new ventilation mode for achieving efficient and accurate environmental control in laying hen cages.
Open AccessCFD Investigation on Combined Ventilation System for Multilayer-Caged-Laying Hen Houses
Mechanical ventilation is an important means of environmental control in multitier laying hen cages. The mainstream ventilation mode currently in use, negative-pressure ventilation (NPV), has the drawbacks of a large temperature difference before and after adjustment and uneven air velocity distribution. To solve these problems, this study designed and analyzed a combined positive and negative-pressure ventilation system for laying hen cages. According to the principle of the conservation of mass to increase the inlet flow in the negative-pressure ventilation system on the basis of the addition of the pressure-wind body-built positive-and-negative-pressure-combined ventilation (PNCV) system, further, computational fluid dynamics (CFD) simulation was performed to analyze the distribution of environmental parameters in the chicken cage zone (CZ) with inlet angles of positive-pressure fans set at 45°, 90°, and 30°. Simulation results showed that the PNCV system increased the average air velocity in the CZ from 0.94 m/s to 1.04 m/s, 1.28 m/s, and 0.99 m/s by actively blowing air into the cage. The maximum temperature difference in the CZ with the PNCV system was 2.91 °C, 1.80 °C, and 3.78 °C, which were all lower than 4.46 °C, the maximum temperature difference in the CZ with the NPV system. Moreover, the relative humidity remained below 80% for the PNCV system and between 80% and 85% for the NPV system. Compared with the NPV system, the PNCV system increased the vertical airflow movement, causing significant cooling and dehumidifying effects. Hence, the proposed system provides an effective new ventilation mode for achieving efficient and accurate environmental control in laying hen cages.
- Open Access
- 10 March 2022
- Published by Elsevier in Poultry Science
- Vol. 101 (6) , 101843
Microclimate environment model construction and control strategy of enclosed laying brooder house
- 10 March 2022
- Published by Elsevier in Poultry Science
- Vol. 101 (6) , 101843
Open AccessMicroclimate environment model construction and control strategy of enclosed laying brooder house
- Open Access
- 15 November 2021
- Published by Elsevier in Poultry Science
- Vol. 101 (2) , 101587
Comprehensive evaluation method of the poultry house indoor environment based on gray relation analysis and analytic hierarchy process
- 15 November 2021
- Published by Elsevier in Poultry Science
- Vol. 101 (2) , 101587
Open AccessComprehensive evaluation method of the poultry house indoor environment based on gray relation analysis and analytic hierarchy process