Florence Druart
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Florence Druart has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
Y. Bultel
6 shared publications- Pierre-Xavier Thivel
Univ. Grenoble Alpes, Univ. Savoie Mont Blanc, CNRS, Grenoble INP, LEPMI, 38000 Grenoble, France
4 shared publications D. Riu
G2Elab, Grenoble Electrical Engineering Laboratory, Grenoble, France
3 shared publications- David Hernández-Torres
Grenoble Electrical Engineering Laboratory, 38400 Saint-Martin-D'Hères, France
3 shared publications - Erwan Tardy
CNRS, Grenoble INP, LEPMI Université Grenoble Alpes, Université Savoie Mont Blanc F‐38000 Grenoble France
3 shared publications - Olivier Sename
Univ. Grenoble Alpes, CNRS, Grenoble INP, GIPSA-lab, 38000 Grenoble, France
3 shared publications
Latest Publications
- Open Access
- 26 July 2025
- Published by Wiley in ChemElectroChem
- Vol. 12 (17)
Understanding the Operation of a Gas Diffusion Electrode Setup for the Oxygen Reduction Reaction: Experiment versus 3D Multiphysics Modeling
Proton exchange membrane fuel cells (PEMFC) require highly efficient oxygen reduction reaction (ORR) electrocatalysts. The intrinsic ORR performance of advanced ORR catalysts (measured in rotating disk electrode, RDE) is often not obtained in membrane electrode assembly (MEA), which denotes for RDE inability to forecast intrinsic activity at large current density/low potential, owing to severe mass‐transport limitation. The gas diffusion electrode (GDE) is a relevant tool to assess the intrinsic ORR activity of catalysts at high current density/low potential, so it enables to better forecast their performance in PEMFC MEA. Herein, ORR kinetics is studied in a GDE via cyclic voltammetry and electrochemical impedance spectroscopy; the polarization curve is modeled using multiphysics and multicomponent 3D simulations. The model allows to investigate the interplay between the electrochemical kinetics and the mass‐transport of reactant and products in the flow channels of the monopolar plate, gas diffusion layer, porous electrode, and solution. The simulations highlight the significant impact of partial water flooding in the catalyst layer—even at a minimal thickness of 0.6 μm—on the shape of the GDE polarization curves and suggest that mass‐transport limitation inside the catalyst layer may be limiting in a GDE setup, specifically at high current density.
- 26 July 2025
- Published by Wiley in ChemElectroChem
- Vol. 12 (17)
Open AccessUnderstanding the Operation of a Gas Diffusion Electrode Setup for the Oxygen Reduction Reaction: Experiment versus 3D Multiphysics Modeling
Proton exchange membrane fuel cells (PEMFC) require highly efficient oxygen reduction reaction (ORR) electrocatalysts. The intrinsic ORR performance of advanced ORR catalysts (measured in rotating disk electrode, RDE) is often not obtained in membrane electrode assembly (MEA), which denotes for RDE inability to forecast intrinsic activity at large current density/low potential, owing to severe mass‐transport limitation. The gas diffusion electrode (GDE) is a relevant tool to assess the intrinsic ORR activity of catalysts at high current density/low potential, so it enables to better forecast their performance in PEMFC MEA. Herein, ORR kinetics is studied in a GDE via cyclic voltammetry and electrochemical impedance spectroscopy; the polarization curve is modeled using multiphysics and multicomponent 3D simulations. The model allows to investigate the interplay between the electrochemical kinetics and the mass‐transport of reactant and products in the flow channels of the monopolar plate, gas diffusion layer, porous electrode, and solution. The simulations highlight the significant impact of partial water flooding in the catalyst layer—even at a minimal thickness of 0.6 μm—on the shape of the GDE polarization curves and suggest that mass‐transport limitation inside the catalyst layer may be limiting in a GDE setup, specifically at high current density.
- Open Access
Three-Dimensional Modeling of Anion Exchange Membrane Electrolysis: A Two-Phase Flow Approach
Anion exchange membrane water electrolyzers (AEMWEs) are attracting growing interest as a green hydrogen production technology. Unlike proton exchange membrane (PEM) systems, AEMWEs operate in an alkaline environment, allowing one to use less expensive, non-noble materials as catalysts for the reactions and non-fluorinated anion exchange polymer membranes. However, the performance and stability of AEMWEs strongly depend on the alkaline electrolyte concentration. In this work, a three-dimensional multi-physics model considering two-phase flow effects is applied to understand the impact of KOH electrolyte concentration and its flow rate on AEMWE performance, as well as on the current and gas volume fraction distributions. The numerical results were compared to experimental data published in the literature. For current densities above 1 A/cm2, a strongly non-uniform H2 and O2 gas volume distribution could be evidenced by the 3D simulations. Increasing the KOH electrolyte flow rate from 10 to 100 mL/min noticeably improves cell performance for current densities above 1 A/cm2. These results show the importance of accounting for the three-dimensional geometry of an AEMWE and two-phase flow effects to accurately describe its operation and performance.
Open AccessThree-Dimensional Modeling of Anion Exchange Membrane Electrolysis: A Two-Phase Flow Approach
Anion exchange membrane water electrolyzers (AEMWEs) are attracting growing interest as a green hydrogen production technology. Unlike proton exchange membrane (PEM) systems, AEMWEs operate in an alkaline environment, allowing one to use less expensive, non-noble materials as catalysts for the reactions and non-fluorinated anion exchange polymer membranes. However, the performance and stability of AEMWEs strongly depend on the alkaline electrolyte concentration. In this work, a three-dimensional multi-physics model considering two-phase flow effects is applied to understand the impact of KOH electrolyte concentration and its flow rate on AEMWE performance, as well as on the current and gas volume fraction distributions. The numerical results were compared to experimental data published in the literature. For current densities above 1 A/cm2, a strongly non-uniform H2 and O2 gas volume distribution could be evidenced by the 3D simulations. Increasing the KOH electrolyte flow rate from 10 to 100 mL/min noticeably improves cell performance for current densities above 1 A/cm2. These results show the importance of accounting for the three-dimensional geometry of an AEMWE and two-phase flow effects to accurately describe its operation and performance.
- Open Access
Simulation of Biogas Conversion Using Porous Solid Oxide Electrochemical Cells: Virtual Prototyping
The computer-aided engineering approach has made it possible to achieve virtual prototypes and to describe expected performances of new apparatuses. In this study, a direct production of syngas with biogas using the configuration of the cascade conversion cell in the supply feed direction of the system was exhibited. Momentum, heat, mass and charge balances were solved using COMSOL Multiphysics® commercial software. These simulations allowed calculation of distributions of partial pressures for all gas species within the anode (CH4, H2, CO, CO2, H2O, N2), as well as velocity field and temperature. The conversion process included methane reforming (steam and dry) associated with the water–gas shift reaction. The computing results showed that the configuration of three porous oxide solid cells based on a solid oxide fuel cell (SOFC) system conferred a larger active surface area and limited thermal stress in oxide materials. In addition, depending on the production process of the biogas, feeding composition strongly influences the conversion rate of CO2 and CH4. We observed that production of syngas was optimal for a CO2/CH4 ratio = 1.
Open AccessSimulation of Biogas Conversion Using Porous Solid Oxide Electrochemical Cells: Virtual Prototyping
The computer-aided engineering approach has made it possible to achieve virtual prototypes and to describe expected performances of new apparatuses. In this study, a direct production of syngas with biogas using the configuration of the cascade conversion cell in the supply feed direction of the system was exhibited. Momentum, heat, mass and charge balances were solved using COMSOL Multiphysics® commercial software. These simulations allowed calculation of distributions of partial pressures for all gas species within the anode (CH4, H2, CO, CO2, H2O, N2), as well as velocity field and temperature. The conversion process included methane reforming (steam and dry) associated with the water–gas shift reaction. The computing results showed that the configuration of three porous oxide solid cells based on a solid oxide fuel cell (SOFC) system conferred a larger active surface area and limited thermal stress in oxide materials. In addition, depending on the production process of the biogas, feeding composition strongly influences the conversion rate of CO2 and CH4. We observed that production of syngas was optimal for a CO2/CH4 ratio = 1.
- 1 August 2018
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 43 (32) , 14867-14875
Low voltage water electrolysis: Decoupling hydrogen production using bioelectrochemical system
- 1 August 2018
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 43 (32) , 14867-14875
Low voltage water electrolysis: Decoupling hydrogen production using bioelectrochemical system
- 8 March 2017
- Published by Wiley in Fuel Cells
- Vol. 17 (2) , 268-276
PHM‐oriented Degradation Indicators for Batteries and Fuel Cells
As electrochemical power sources technologies, namely Li‐ion batteries and PEM fuel cells, continue advancing, ways to extend their lifespan have to be pursued. With prognostics and health management (PHM) approach, several techniques can provide estimation of state of health (SOH) and prediction of remaining useful life (RUL) in order to help the manufacturers improving performance. Before developing a solution, PHM issues need to be properly defined, in particular in terms of deterioration/ageing indicators used for SOH estimation and RUL prediction.This paper reviews the ageing phenomena of batteries and fuel cells in order to investigate how to define suitable degradation indicators for these devices. Since Li‐ion battery' PHM is much more developed, their similarities and differences have thus been studied as an exploration path of how proton exchange membrane fuel cell (PEMFC) could benefit from the battery knowledge and experience feedback. Even if no innovative solutions are emerging, the relevance of the covariates used for PEMFC and batteries ageing indicators are argued, providing a first step to build a suitable PHM approach for electrochemical devices.
- 8 March 2017
- Published by Wiley in Fuel Cells
- Vol. 17 (2) , 268-276
PHM‐oriented Degradation Indicators for Batteries and Fuel Cells
As electrochemical power sources technologies, namely Li‐ion batteries and PEM fuel cells, continue advancing, ways to extend their lifespan have to be pursued. With prognostics and health management (PHM) approach, several techniques can provide estimation of state of health (SOH) and prediction of remaining useful life (RUL) in order to help the manufacturers improving performance. Before developing a solution, PHM issues need to be properly defined, in particular in terms of deterioration/ageing indicators used for SOH estimation and RUL prediction.This paper reviews the ageing phenomena of batteries and fuel cells in order to investigate how to define suitable degradation indicators for these devices. Since Li‐ion battery' PHM is much more developed, their similarities and differences have thus been studied as an exploration path of how proton exchange membrane fuel cell (PEMFC) could benefit from the battery knowledge and experience feedback. Even if no innovative solutions are emerging, the relevance of the covariates used for PEMFC and batteries ageing indicators are argued, providing a first step to build a suitable PHM approach for electrochemical devices.
- 1 July 2014
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 39 (20) , 10613-10626
Diagnostic tools for PEMFCs: from conception to implementation
- 1 July 2014
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 39 (20) , 10613-10626
Diagnostic tools for PEMFCs: from conception to implementation
- 1 July 2014
- Published by Elsevier in Electrochimica Acta
- Vol. 135, 368-379
An algorithm for diagnosis of proton exchange membrane fuel cells by electrochemical impedance spectroscopy
- 1 July 2014
- Published by Elsevier in Electrochimica Acta
- Vol. 135, 368-379
An algorithm for diagnosis of proton exchange membrane fuel cells by electrochemical impedance spectroscopy
- 1 January 2014
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 47 (3) , 11482-11487
Diagnosis of PEM fuel cell stack based on magnetic fields measurements
- 1 January 2014
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 47 (3) , 11482-11487
Diagnosis of PEM fuel cell stack based on magnetic fields measurements
- 20 May 2011
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 54 (2) , 23407
A robust multivariable approach for hybrid fuel cell supercapacitor power generation system
In this article, a control methodology is proposed for a hybrid power generation system composed by a 500 W PEM fuel cell and a 58 F supercapacitor. The control strategy consists in synthetizing a multivariable PI controller with performance in order to manage powers between two electrochemical sources. The controller is then designed through an optimization procedure based on solving some linear matrix inequalities (LMI). The control performance in time and frequency domains are then analyzed and compared with classical controllers. Results show the efficiency of the proposed methodology in order to reduce time spent for design.
- 20 May 2011
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 54 (2) , 23407
A robust multivariable approach for hybrid fuel cell supercapacitor power generation system
In this article, a control methodology is proposed for a hybrid power generation system composed by a 500 W PEM fuel cell and a 58 F supercapacitor. The control strategy consists in synthetizing a multivariable PI controller with performance in order to manage powers between two electrochemical sources. The controller is then designed through an optimization procedure based on solving some linear matrix inequalities (LMI). The control performance in time and frequency domains are then analyzed and compared with classical controllers. Results show the efficiency of the proposed methodology in order to reduce time spent for design.