CGChristelle Ghazaly

Christelle Ghazaly

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christelle Ghazaly has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Blandine Castel

    Département de Métrologie des Polluants, Institut National de Recherche et de Sécurité (INRS), 54500 Vandœuvre-lès-Nancy, France

    1 shared publication
  • Eddy Langlois

    Département de Métrologie des Polluants, Institut National de Recherche et de Sécurité (INRS), 54500 Vandœuvre-lès-Nancy, France

    1 shared publication
  • Emmanuel Naline

    Département des maladies des voies respiratoires, Hôpital Foch, Exhalomics, Suresnes, France

    1 shared publication
  • Emmanuel Scorsone

    Université Paris-Saclay, CEA, List, F-91120 Palaiseau, France

    1 shared publication
  • Etienne A Thevenot

    Département Médicaments et Technologies Pour la Santé (DMTS), Université Paris-Saclay, CEA, INRAE, MetaboHUB, 91191 Gif-sur-Yvette, France

    1 shared publication
  • Krystyna Biletska

    Université Paris-Saclay, CEA, List, F-91120 Palaiseau, France

    1 shared publication

Latest Publications

  • Assessment of an e-nose performance for the detection of COVID-19 specific biomarkers

    by Christelle Ghazaly, Krystyna Biletska, Etienne A Thevenot, Philippe Devillier, Emmanuel Naline, Stanislas Grassin-Delyle, Emmanuel Scorsone

    Early, rapid and non-invasive diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is needed for the prevention and control of coronavirus disease 2019 (COVID-19). COVID-19 mainly affects the respiratory tract and lungs. Therefore, analysis of exhaled breath could be an alternative scalable method for reliable SARS-CoV-2 screening. In the current study, an experimental protocol using an electronic-nose (‘e-nose’) for attempting to identify a specific respiratory imprint in COVID-19 patients was optimized. Thus the analytical performances of the Cyranose®, a commercial e-nose device, were characterized under various controlled conditions. In addition, the effect of various experimental conditions on its sensor array response was assessed, including relative humidity, sampling time and flow rate, aiming to select the optimal parameters. A statistical data analysis was applied to e-nose sensor response using common statistical analysis algorithms in an attempt to demonstrate the possibility to detect the presence of low concentrations of spiked acetone and nonanal in the breath samples of a healthy volunteer. Cyranose® reveals a possible detection of low concentrations of these two compounds, in particular of 25 ppm nonanal, a possible marker of SARS-CoV-2 in the breath.


  • Open Access

    Real-Time Ozone Sensor Based on Selective Oxidation of Methylene Blue in Mesoporous Silica Films

    by Christelle Ghazaly, Marc Hébrant, Eddy Langlois, Blandine Castel, Marianne Guillemot, Mathieu Etienne

    Sensitive and selective personal exposure monitors are needed to assess ozone (O3) concentrations in the workplace atmosphere in real time for the analysis and prevention of health risks. Here, a cumulative gas sensor using visible spectroscopy for real-time O3 determination is described. The sensing chip is a mesoporous silica thin film deposited on transparent glass and impregnated with methylene blue (MB). The sensor is reproducible, stable for at least 50 days, sensitive to 10 ppb O3 (one-tenth of the occupational exposure limit value in France, Swiss, Canada, U.K., Japan, and the USA) with a measurement range tested up to 500 ppb, and insensitive to NO2 and to large variation in relative humidity. A model and its derivative as a function of time are proposed to convert in real time the sensor response to concentrations, and an excellent correlation was obtained between those data and reference O3 concentrations. This sensor is based on a relatively cheap sensing material and a robust detection system, and its analytical performance makes it suitable for monitoring real-time O3 concentrations in workplaces to promote a safer environment for workers.