Jelle Bernards
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jelle Bernards has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Manu L. N. G. Malbrain
First Department of Anaesthesiology and Intensive Therapy Medical University of Lublin Lublin Poland
3 shared publications Yannick Peeters
ZNA Stuivenberg, Lange Beeldekensstraat 267, B-2060 Antwerpen, Belgium
3 shared publicationsBritta Hoffmann
2 shared publicationsMarijke De Raes
2 shared publications- Michaël Mekeirele
Vrije Universiteit Brussel, Brussels, Belgium
2 shared publications A Corveleyn
D Department of Pediatric Nephrology, Department of Development and Regeneration, University Hospitals Leuven , Leuven , Belgium
1 shared publication
Latest Publications
- 8 August 2026
- Published by Elsevier in The American Journal of Cardiology
- Vol. 277, 36-43
Long-term Outcomes of Renal Function Following CTO PCI: Insights on Contrast Exposure
- 8 August 2026
- Published by Elsevier in The American Journal of Cardiology
- Vol. 277, 36-43
Long-term Outcomes of Renal Function Following CTO PCI: Insights on Contrast Exposure
- 21 April 2023
- Published by Wolters Kluwer Health in Clinical Journal of the American Society of Nephrology
- Vol. 18 (7) , 881-891
Epidemiology, Outcomes, and Complement Gene Variants in Secondary Thrombotic Microangiopathies
Background: The identification of complement defects as major drivers of primary atypical hemolytic uremic syndrome (HUS) has transformed the landscape of thrombotic microangiopathies (TMAs), leading to the development of targeted therapies and better patient outcomes. By contrast, little is known about the presentation, genetics, and outcomes of TMA associated with specific diseases or conditions, also referred to as secondary TMA. Methods: In this study, we assessed the relative incidence, clinical and genetic spectra, and long-term outcomes of secondary TMA versus other TMAs in consecutive patients hospitalized with a first episode of TMA from 2009 to 2019 at two European reference centers. Results: During the study period, 336 patients were hospitalized with a first episode of TMA. Etiologies included atypical HUS in 49 patients (15%), thrombotic thrombocytopenic purpura (TTP) in 29 (9%), shigatoxin-associated HUS in 70 (21%), and secondary TMA in 188 (56%). The main causes of secondary TMA were hematopoietic stem-cell transplantation (n=56, 30%), solid-organ transplantation (n=44, 23%), and malignant hypertension (n=25, 13%). Rare variants in complement genes were identified in 32 of 49 patients (65%) with atypical HUS and eight of 64 patients (13%) with secondary TMA; pathogenic or likely pathogenic variants were found in 24 of 49 (49%) and two of 64 (3%) of them, respectively (P < 0.001). After a median follow-up of 1157 days, death or kidney failure occurred in 14 (29%), eight (28%), five (7%), and 121 (64%) patients with atypical HUS, TTP, shigatoxin-associated HUS, and secondary TMA, respectively. Unadjusted and adjusted Cox regressions showed that patients with secondary TMA had the highest risk of death or kidney failure (unadjusted hazard ratio [HR], 3.35; 95% confidence interval [CI], 1.85 to 6.07; P < 0.001; adjusted HR, 4.11; 95% CI, 2.00 to 8.46; P < 0.001; considering atypical HUS as reference). Conclusions: Secondary TMAs represent the main cause of TMA and are independently associated with a high risk of death and progression to kidney failure.
- 21 April 2023
- Published by Wolters Kluwer Health in Clinical Journal of the American Society of Nephrology
- Vol. 18 (7) , 881-891
Epidemiology, Outcomes, and Complement Gene Variants in Secondary Thrombotic Microangiopathies
Background: The identification of complement defects as major drivers of primary atypical hemolytic uremic syndrome (HUS) has transformed the landscape of thrombotic microangiopathies (TMAs), leading to the development of targeted therapies and better patient outcomes. By contrast, little is known about the presentation, genetics, and outcomes of TMA associated with specific diseases or conditions, also referred to as secondary TMA. Methods: In this study, we assessed the relative incidence, clinical and genetic spectra, and long-term outcomes of secondary TMA versus other TMAs in consecutive patients hospitalized with a first episode of TMA from 2009 to 2019 at two European reference centers. Results: During the study period, 336 patients were hospitalized with a first episode of TMA. Etiologies included atypical HUS in 49 patients (15%), thrombotic thrombocytopenic purpura (TTP) in 29 (9%), shigatoxin-associated HUS in 70 (21%), and secondary TMA in 188 (56%). The main causes of secondary TMA were hematopoietic stem-cell transplantation (n=56, 30%), solid-organ transplantation (n=44, 23%), and malignant hypertension (n=25, 13%). Rare variants in complement genes were identified in 32 of 49 patients (65%) with atypical HUS and eight of 64 patients (13%) with secondary TMA; pathogenic or likely pathogenic variants were found in 24 of 49 (49%) and two of 64 (3%) of them, respectively (P < 0.001). After a median follow-up of 1157 days, death or kidney failure occurred in 14 (29%), eight (28%), five (7%), and 121 (64%) patients with atypical HUS, TTP, shigatoxin-associated HUS, and secondary TMA, respectively. Unadjusted and adjusted Cox regressions showed that patients with secondary TMA had the highest risk of death or kidney failure (unadjusted hazard ratio [HR], 3.35; 95% confidence interval [CI], 1.85 to 6.07; P < 0.001; adjusted HR, 4.11; 95% CI, 2.00 to 8.46; P < 0.001; considering atypical HUS as reference). Conclusions: Secondary TMAs represent the main cause of TMA and are independently associated with a high risk of death and progression to kidney failure.
- 11 August 2019
- Published by Taylor & Francis in Acta Clinica Belgica
- Vol. 76 (1) , 65-69
Hyperhomocysteinemia: a trigger for complement-mediated TMA?
A 34-year-old man of North African descent was referred to the emergency department because of malignant hypertension (220/113 mmHg), acute visual disturbances and acute kidney failure (serum creatinine 14.0 mg/dL). Blood analysis was compatible with thrombotic microangiopathy (TMA). Kidney biopsy confirmed this diagnosis with histological changes including intimal edema, arteriolar thrombi, and severe tubulointerstitial damage. Fundoscopy showed hypertensive retinopathy stage IV. Subsequent biochemical screening revealed normal complement testing and a marked elevation in homocysteine concentration (161 µmol/L; normal value 7–15 µmol/L). Other secondary causes of TMA were excluded. Further genetic testing for cobalamin C (cblC) deficiency showed no pathogenic mutations in the MMACHC gene. However, a homozygous c.665C>T polymorphism (NM_005957.4) in the methylenetetrahydrofolate reductase (MTHFR) gene was found explaining the severe hyperhomocysteinemia due to reduced activity of MTHFR. Additional genetic testing for alternative complement pathway proteins showed mutations in the genes encoding factor H and factor B, both categorized as possibly pathogenic using mutation prediction software. This is the first described case of TMA in a patient with severe hyperhomocysteinemia caused by a genetic defect other than cblC. We postulate that endothelial damage due to hyperhomocysteinemia and hypertension could have triggered the TMA episode in this patient with two possible predisposing pathogenic mutations in the alternative complement pathway. Furthermore, our case demonstrates the need for complete full diagnostic testing in patients with TMA.
- 11 August 2019
- Published by Taylor & Francis in Acta Clinica Belgica
- Vol. 76 (1) , 65-69
Hyperhomocysteinemia: a trigger for complement-mediated TMA?
A 34-year-old man of North African descent was referred to the emergency department because of malignant hypertension (220/113 mmHg), acute visual disturbances and acute kidney failure (serum creatinine 14.0 mg/dL). Blood analysis was compatible with thrombotic microangiopathy (TMA). Kidney biopsy confirmed this diagnosis with histological changes including intimal edema, arteriolar thrombi, and severe tubulointerstitial damage. Fundoscopy showed hypertensive retinopathy stage IV. Subsequent biochemical screening revealed normal complement testing and a marked elevation in homocysteine concentration (161 µmol/L; normal value 7–15 µmol/L). Other secondary causes of TMA were excluded. Further genetic testing for cobalamin C (cblC) deficiency showed no pathogenic mutations in the MMACHC gene. However, a homozygous c.665C>T polymorphism (NM_005957.4) in the methylenetetrahydrofolate reductase (MTHFR) gene was found explaining the severe hyperhomocysteinemia due to reduced activity of MTHFR. Additional genetic testing for alternative complement pathway proteins showed mutations in the genes encoding factor H and factor B, both categorized as possibly pathogenic using mutation prediction software. This is the first described case of TMA in a patient with severe hyperhomocysteinemia caused by a genetic defect other than cblC. We postulate that endothelial damage due to hyperhomocysteinemia and hypertension could have triggered the TMA episode in this patient with two possible predisposing pathogenic mutations in the alternative complement pathway. Furthermore, our case demonstrates the need for complete full diagnostic testing in patients with TMA.
- Open Access
- 16 December 2016
- Published by F1000 Research Ltd in F1000Research
- Vol. 5, 2855
Hemodynamic monitoring in the critically ill: an overview of current cardiac output monitoring methods
Critically ill patients are often hemodynamically unstable (or at risk of becoming unstable) owing to hypovolemia, cardiac dysfunction, or alterations of vasomotor function, leading to organ dysfunction, deterioration into multi-organ failure, and eventually death. With hemodynamic monitoring, we aim to guide our medical management so as to prevent or treat organ failure and improve the outcomes of our patients. Therapeutic measures may include fluid resuscitation, vasopressors, or inotropic agents. Both resuscitation and de-resuscitation phases can be guided using hemodynamic monitoring. This monitoring itself includes several different techniques, each with its own advantages and disadvantages, and may range from invasive to less- and even non-invasive techniques, calibrated or non-calibrated. This article will discuss the indications and basics of monitoring, further elaborating on the different techniques of monitoring.
- 16 December 2016
- Published by F1000 Research Ltd in F1000Research
- Vol. 5, 2855
Open AccessHemodynamic monitoring in the critically ill: an overview of current cardiac output monitoring methods
Critically ill patients are often hemodynamically unstable (or at risk of becoming unstable) owing to hypovolemia, cardiac dysfunction, or alterations of vasomotor function, leading to organ dysfunction, deterioration into multi-organ failure, and eventually death. With hemodynamic monitoring, we aim to guide our medical management so as to prevent or treat organ failure and improve the outcomes of our patients. Therapeutic measures may include fluid resuscitation, vasopressors, or inotropic agents. Both resuscitation and de-resuscitation phases can be guided using hemodynamic monitoring. This monitoring itself includes several different techniques, each with its own advantages and disadvantages, and may range from invasive to less- and even non-invasive techniques, calibrated or non-calibrated. This article will discuss the indications and basics of monitoring, further elaborating on the different techniques of monitoring.
- Open Access
- 4 December 2015
- Published by Termedia Sp. z.o.o. in Anaesthesiology Intensive Therapy
- Vol. 47 (5) , 501-516
Hemodynamic monitoring: To calibrate or not to calibrate? Part 2 — Non-calibrated techniques
There is much evidence that fluid overload leads to adverse outcomes in perioperative and critically ill patients. Cardiac output monitoring can help us guiding initial and ongoing fluid resuscitation and can help us to assess whether a patient will be responsive to fluids when hypotensive. In recent years, many sophisticated devices that measure a variety of hemodynamic parameters have evolved on the market. We wanted to provide an overview of the different techniques available today, including their validation in different patient populations. In this second part of the review, we focus on non-calibrated techniques, both invasive and non-invasive. For each technique a short overview of the working principle, together with the advantages, disadvantages and the available validation literature is listed. Many promising minimal invasive monitoring devices can help us to further optimize our hemodynamic treatment in both the perioperative and critical care setting. However, the validation data are scarce for many of these techniques, especially in complex circumstances with changing hemodynamics (preload, afterload and contractility), as with the use of fluids and vasoactive medication. The measurements made by these devices, therefore, need to be interpreted with caution. Further improvements and more validation data are needed before these techniques can be implemented in common day practice. Moreover, in severely shocked hemodynamic unstable patients, calibrated techniques are to be preferred over those which are uncalibrated. Hence, the new techniques not only need to be accurate, but also need to be precise in order to keep track of changes.
- 4 December 2015
- Published by Termedia Sp. z.o.o. in Anaesthesiology Intensive Therapy
- Vol. 47 (5) , 501-516
Open AccessHemodynamic monitoring: To calibrate or not to calibrate? Part 2 — Non-calibrated techniques
There is much evidence that fluid overload leads to adverse outcomes in perioperative and critically ill patients. Cardiac output monitoring can help us guiding initial and ongoing fluid resuscitation and can help us to assess whether a patient will be responsive to fluids when hypotensive. In recent years, many sophisticated devices that measure a variety of hemodynamic parameters have evolved on the market. We wanted to provide an overview of the different techniques available today, including their validation in different patient populations. In this second part of the review, we focus on non-calibrated techniques, both invasive and non-invasive. For each technique a short overview of the working principle, together with the advantages, disadvantages and the available validation literature is listed. Many promising minimal invasive monitoring devices can help us to further optimize our hemodynamic treatment in both the perioperative and critical care setting. However, the validation data are scarce for many of these techniques, especially in complex circumstances with changing hemodynamics (preload, afterload and contractility), as with the use of fluids and vasoactive medication. The measurements made by these devices, therefore, need to be interpreted with caution. Further improvements and more validation data are needed before these techniques can be implemented in common day practice. Moreover, in severely shocked hemodynamic unstable patients, calibrated techniques are to be preferred over those which are uncalibrated. Hence, the new techniques not only need to be accurate, but also need to be precise in order to keep track of changes.
- Open Access
- 4 December 2015
- Published by Termedia Sp. z.o.o. in Anaesthesiology Intensive Therapy
- Vol. 47 (5) , 487-500
Hemodynamic monitoring: To calibrate or not to calibrate? Part 1 – Calibrated techniques
Over recent decades, hemodynamic monitoring has evolved from basic cardiac output monitoring techniques to a broad variety of sophisticated monitoring devices with extra parameters. In order to reduce morbidity and mortality and optimize therapeutic strategies, different monitoring techniques can be used to guide fluid resuscitation and other medical management. Generally, they can be divided in calibrated and non-calibrated techniques. In the first part of this review, the available calibrated techniques, ranging from invasive to non-invasive, will be discussed. We performed a review of the literature in order to give an overview of the current hemodynamic monitoring devices. For each monitoring system, a short overview of the physical principles, the advantages and disadvantages and the available literature with regard to validation is given. Currently, many promising hemodynamic monitoring devices are readily available in order to optimize therapeutic management in both perioperative and ICU settings. Although several of these calibrated techniques have been validated in the literature, not all techniques have been shown to reduce morbidity and mortality. Many new techniques, especially some non-calibrated devices, lack good validation data in different clinical settings (sepsis, trauma, burns, etc.). The cardiac output values obtained with these techniques need therefore to be interpreted with caution as will be discussed in the second part of this concise review. Transthoracic echocardiography forms a good initial choice to assess hemodynamics in critically ill patients after initial stabilisation. However in complex situations or in patients not responding to fluid resuscitation alone, advanced hemodynamic monitoring is recommended with the use of calibrated techniques like transpulmonary thermodilution. Calibrated techniques are preferred in patients with severe shock and changing conditions of preload, afterload and contractility. The use of the pulmonary artery catheter should be reserved for patients with right ventricular failure in order to assess the effect of medical treatment.
- 4 December 2015
- Published by Termedia Sp. z.o.o. in Anaesthesiology Intensive Therapy
- Vol. 47 (5) , 487-500
Open AccessHemodynamic monitoring: To calibrate or not to calibrate? Part 1 – Calibrated techniques
Over recent decades, hemodynamic monitoring has evolved from basic cardiac output monitoring techniques to a broad variety of sophisticated monitoring devices with extra parameters. In order to reduce morbidity and mortality and optimize therapeutic strategies, different monitoring techniques can be used to guide fluid resuscitation and other medical management. Generally, they can be divided in calibrated and non-calibrated techniques. In the first part of this review, the available calibrated techniques, ranging from invasive to non-invasive, will be discussed. We performed a review of the literature in order to give an overview of the current hemodynamic monitoring devices. For each monitoring system, a short overview of the physical principles, the advantages and disadvantages and the available literature with regard to validation is given. Currently, many promising hemodynamic monitoring devices are readily available in order to optimize therapeutic management in both perioperative and ICU settings. Although several of these calibrated techniques have been validated in the literature, not all techniques have been shown to reduce morbidity and mortality. Many new techniques, especially some non-calibrated devices, lack good validation data in different clinical settings (sepsis, trauma, burns, etc.). The cardiac output values obtained with these techniques need therefore to be interpreted with caution as will be discussed in the second part of this concise review. Transthoracic echocardiography forms a good initial choice to assess hemodynamics in critically ill patients after initial stabilisation. However in complex situations or in patients not responding to fluid resuscitation alone, advanced hemodynamic monitoring is recommended with the use of calibrated techniques like transpulmonary thermodilution. Calibrated techniques are preferred in patients with severe shock and changing conditions of preload, afterload and contractility. The use of the pulmonary artery catheter should be reserved for patients with right ventricular failure in order to assess the effect of medical treatment.
- 1 December 2014
- Published by Elsevier in International Journal of Cardiology
- Vol. 177 (2) , e53-e55
Transient left ventricular apical ballooning syndrome in a patient with allopurinol induced skin rash: A case report
- 1 December 2014
- Published by Elsevier in International Journal of Cardiology
- Vol. 177 (2) , e53-e55
Transient left ventricular apical ballooning syndrome in a patient with allopurinol induced skin rash: A case report