Alex Gaudio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alex Gaudio has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Asim Smailagic
Carnegie Mellon University, Pittsburgh, USA
6 shared publications - Aurélio Campilho
Institute for Systems and Computer Engineering, Technology and Science (INESC TEC)
6 shared publications - Christos Faloutsos
Carnegie Mellon University
3 shared publications - Mounya Elhilali
Laboratory for Computational Audio Perception, Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA
3 shared publications Pedro Costa
Faculty of Engineering University of Porto Porto Portugal
3 shared publications- Pedro Costa
University of Porto
3 shared publications
Latest Publications
- Open Access
- 19 September 2025
- Published by International Society of Global Health in Journal of Global Health
- Vol. 15, 04264
Performance of an artificial intelligence algorithm for interpreting lung sounds from children hospitalised with pneumonia in Malawi
Pneumonia remains the leading infectious cause of mortality in children under five worldwide [1,2]. The World Health Organization (WHO) Integrated Management of Childhood Illnesses (IMCI) guidelines provide the current standard for managing paediatric pneumonia in low-income and middle-income countries (LMICs) [3]. Developed in the 1980s, the IMCI algorithm enables non-physician health care workers (HCWs) to […]
- 19 September 2025
- Published by International Society of Global Health in Journal of Global Health
- Vol. 15, 04264
Open AccessPerformance of an artificial intelligence algorithm for interpreting lung sounds from children hospitalised with pneumonia in Malawi
Pneumonia remains the leading infectious cause of mortality in children under five worldwide [1,2]. The World Health Organization (WHO) Integrated Management of Childhood Illnesses (IMCI) guidelines provide the current standard for managing paediatric pneumonia in low-income and middle-income countries (LMICs) [3]. Developed in the 1980s, the IMCI algorithm enables non-physician health care workers (HCWs) to […]
- Open Access
- 5 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (14) , 26711-26722
Diaphragm Design for an Electret Microphone Stethoscope
This paper investigates the design elements of a digital stethoscope and its signal fidelity in the presence of ambient noise. While the acoustic impedance matching literature demonstrates that signal pickup can improve when the diaphragm’s acoustic impedance closely matches that of the auscultated surface, this approach considers only one interface between two materials. Acoustic impedance matching with two materials may not explain the full picture for electret microphones, which introduce an air gap in their design and therefore have two interfaces between three materials. Introducing a hole in the electret stethoscope diaphragm reduces the three material impedance matching problem into a two material problem. Our empirical results with a 3-d printed electret stethoscope show that a hole in the diaphragm improves signal quality in a variety of tested settings. We additionally propose signal fidelity and noise leakage statistics, a signal quality score, and an amplitude spectrum, all based on the empirical distance correlation. We utilize these statistics to evaluate how all combinations of four diaphragm materials, six diaphragm thicknesses, and presence or absence of a hole affect signal quality of lung sounds in different ambient noise conditions on an acoustic phantom. Moreover, a result of this work is the fabrication of a high quality and low cost ($5 USD) digital stethoscope that can be fabricated with a 3-d printer, soldering iron, electret microphone, and readily available materials.
- 5 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (14) , 26711-26722
Open AccessDiaphragm Design for an Electret Microphone Stethoscope
This paper investigates the design elements of a digital stethoscope and its signal fidelity in the presence of ambient noise. While the acoustic impedance matching literature demonstrates that signal pickup can improve when the diaphragm’s acoustic impedance closely matches that of the auscultated surface, this approach considers only one interface between two materials. Acoustic impedance matching with two materials may not explain the full picture for electret microphones, which introduce an air gap in their design and therefore have two interfaces between three materials. Introducing a hole in the electret stethoscope diaphragm reduces the three material impedance matching problem into a two material problem. Our empirical results with a 3-d printed electret stethoscope show that a hole in the diaphragm improves signal quality in a variety of tested settings. We additionally propose signal fidelity and noise leakage statistics, a signal quality score, and an amplitude spectrum, all based on the empirical distance correlation. We utilize these statistics to evaluate how all combinations of four diaphragm materials, six diaphragm thicknesses, and presence or absence of a hole affect signal quality of lung sounds in different ambient noise conditions on an acoustic phantom. Moreover, a result of this work is the fabrication of a high quality and low cost ($5 USD) digital stethoscope that can be fabricated with a 3-d printer, soldering iron, electret microphone, and readily available materials.
- Open Access
- 2 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Pulmonary Hypertension Detection from Heart Sound Analysis
The detection of Pulmonary Hypertension (PH) from the computer analysis of digitized heart sounds is a low-cost and non-invasive solution for early PH detection and screening. We present an extensive cross-domain evaluation methodology with varying animals (humans and porcine animals) and varying auscultation technologies (phonocardiography and seisomocardiography) evaluated across four methods. We introduce PH-ELM, a resource-efficient PH detection model based on the extreme learning machine that is smaller (300× fewer parameters), energy efficient (532× fewer watts of power), faster (36× faster to train, 44× faster at inference), and more accurate on out-of-distribution testing (improves median accuracy by 0.09 area under the ROC curve (auROC)) in comparison to a previously best performing deep network. We make four observations from our analysis: (a) digital auscultation is a promising technology for the detection of pulmonary hypertension; (b) seismocardiography (SCG) signals and phonocardiography (PCG) signals are interchangeable to train PH detectors; (c) porcine heart sounds in the training data can be used to evaluate PH from human heart sounds (the PH-ELM model preserves 88 to 95% of the best in-distribution baseline performance); (d) predictive performance of PH detection can be mostly preserved with as few as 10 heartbeats and capturing up to approximately 200 heartbeats per subject can improve performance.
- 2 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessPulmonary Hypertension Detection from Heart Sound Analysis
The detection of Pulmonary Hypertension (PH) from the computer analysis of digitized heart sounds is a low-cost and non-invasive solution for early PH detection and screening. We present an extensive cross-domain evaluation methodology with varying animals (humans and porcine animals) and varying auscultation technologies (phonocardiography and seisomocardiography) evaluated across four methods. We introduce PH-ELM, a resource-efficient PH detection model based on the extreme learning machine that is smaller (300× fewer parameters), energy efficient (532× fewer watts of power), faster (36× faster to train, 44× faster at inference), and more accurate on out-of-distribution testing (improves median accuracy by 0.09 area under the ROC curve (auROC)) in comparison to a previously best performing deep network. We make four observations from our analysis: (a) digital auscultation is a promising technology for the detection of pulmonary hypertension; (b) seismocardiography (SCG) signals and phonocardiography (PCG) signals are interchangeable to train PH detectors; (c) porcine heart sounds in the training data can be used to evaluate PH from human heart sounds (the PH-ELM model preserves 88 to 95% of the best in-distribution baseline performance); (d) predictive performance of PH detection can be mostly preserved with as few as 10 heartbeats and capturing up to approximately 200 heartbeats per subject can improve performance.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (10) , 2902-2914
Pulmonary Hypertension Detection From Heart Sound Analysis
The detection of Pulmonary Hypertension (PH) from the computer analysis of digitized heart sounds is a low-cost and non-invasive solution for early PH detection and screening. We present an extensive cross-domain evaluation methodology with varying animals (humans and porcine animals) and varying auscultation technologies (phonocardiography and seisomocardiography) evaluated across four methods. We introduce PH-ELM, a resource-efficient PH detection model based on the extreme learning machine that is smaller ($300\times$ fewer parameters), energy efficient ($532\times$ fewer watts of power), faster ($36\times$ faster to train, $44\times$ faster at inference), and more accurate on out-of-distribution testing (improves median accuracy by 0.09 area under the ROC curve (auROC)) in comparison to a previously best performing deep network. We make four observations from our analysis: (a) digital auscultation is a promising technology for the detection of pulmonary hypertension; (b) seismocardiography (SCG) signals and phonocardiography (PCG) signals are interchangeable to train PH detectors; (c) porcine heart sounds in the training data can be used to evaluate PH from human heart sounds (the PH-ELM model preserves 88 to 95% of the best in-distribution baseline performance); (d) predictive performance of PH detection can be mostly preserved with as few as 10 heartbeats and capturing up to approximately 200 heartbeats per subject can improve performance.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (10) , 2902-2914
Pulmonary Hypertension Detection From Heart Sound Analysis
The detection of Pulmonary Hypertension (PH) from the computer analysis of digitized heart sounds is a low-cost and non-invasive solution for early PH detection and screening. We present an extensive cross-domain evaluation methodology with varying animals (humans and porcine animals) and varying auscultation technologies (phonocardiography and seisomocardiography) evaluated across four methods. We introduce PH-ELM, a resource-efficient PH detection model based on the extreme learning machine that is smaller ($300\times$ fewer parameters), energy efficient ($532\times$ fewer watts of power), faster ($36\times$ faster to train, $44\times$ faster at inference), and more accurate on out-of-distribution testing (improves median accuracy by 0.09 area under the ROC curve (auROC)) in comparison to a previously best performing deep network. We make four observations from our analysis: (a) digital auscultation is a promising technology for the detection of pulmonary hypertension; (b) seismocardiography (SCG) signals and phonocardiography (PCG) signals are interchangeable to train PH detectors; (c) porcine heart sounds in the training data can be used to evaluate PH from human heart sounds (the PH-ELM model preserves 88 to 95% of the best in-distribution baseline performance); (d) predictive performance of PH detection can be mostly preserved with as few as 10 heartbeats and capturing up to approximately 200 heartbeats per subject can improve performance.
- Open Access
- 2 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
AP*: A Modified Average Precision Score and Precision Recall Space for Class Imbalanced Datasets
Rank metrics quantify machine learning model prediction errors in the setting of binary classification with a given dataset, but imbalances in the class distribution or model predictions can significantly influence the interpretation. We analyze and interpret the area under the receiver operating characteristic curve (auROC) and an area under the precision recall curve, or average precision score (AP), in the presence of two kinds of imbalance: dataset class imbalance and model prediction imbalance. We show that the auROC can have a symmetric but not necessarily uni-modal response to dataset imbalance, but it is insensitive to model prediction imbalance. The AP has an asymmetric response that we show is also not uni-modal. The AP and auROC scores can be challenging to interpret due to these properties. We propose a novel precision recall space, the PR*, and associated average precision score, called AP*, to address the identified shortcomings of the AP and auROC. The proposed AP* metric has a symmetric response to class imbalance, like the auROC, a sensitivity to model prediction imbalance, like the AP, and it adds both a symmetry to model prediction imbalance and unimodal response to class imbalance that makes it more reliable for model selection than the AP or auROC. For model selection, the AP* gives a higher score to the model that tends to make most of its errors in the majority class.
- 2 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessAP*: A Modified Average Precision Score and Precision Recall Space for Class Imbalanced Datasets
Rank metrics quantify machine learning model prediction errors in the setting of binary classification with a given dataset, but imbalances in the class distribution or model predictions can significantly influence the interpretation. We analyze and interpret the area under the receiver operating characteristic curve (auROC) and an area under the precision recall curve, or average precision score (AP), in the presence of two kinds of imbalance: dataset class imbalance and model prediction imbalance. We show that the auROC can have a symmetric but not necessarily uni-modal response to dataset imbalance, but it is insensitive to model prediction imbalance. The AP has an asymmetric response that we show is also not uni-modal. The AP and auROC scores can be challenging to interpret due to these properties. We propose a novel precision recall space, the PR*, and associated average precision score, called AP*, to address the identified shortcomings of the AP and auROC. The proposed AP* metric has a symmetric response to class imbalance, like the auROC, a sensitivity to model prediction imbalance, like the AP, and it adds both a symmetry to model prediction imbalance and unimodal response to class imbalance that makes it more reliable for model selection than the AP or auROC. For model selection, the AP* gives a higher score to the model that tends to make most of its errors in the majority class.
- Open Access
- 29 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 34632-34643
Separation of the Aortic and Pulmonary Components of the Second Heart Sound via Alternating Optimization
An algorithm for blind source separation (BSS) of the second heart sound (S2) into aortic and pulmonary components is proposed. It recovers aortic (A2) and pulmonary (P2) waveforms, as well as their relative delays, by solving an alternating optimization problem on the set of S2 sounds, without the use of auxiliary ECG or respiration phase measurement data. This unsupervised and data-driven approach assumes that the A2 and P2 components maintain the same waveform across heartbeats and that the relative delay between onset of the components varies according to respiration phase. The proposed approach is applied to synthetic heart sounds and to real-world heart sounds from 43 patients. It improves over two state-of-the-art BSS approaches by 10% normalized root mean-squared error in the reconstruction of aortic and pulmonary components using synthetic heart sounds, demonstrates robustness to noise, and recovery of splitting delays. The detection of pulmonary hypertension (PH) in a Brazilian population is demonstrated by training a classifier on three scalar features from the recovered A2 and P2 waveforms, and this yields an auROC of 0.76.
- 29 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 34632-34643
Open AccessSeparation of the Aortic and Pulmonary Components of the Second Heart Sound via Alternating Optimization
An algorithm for blind source separation (BSS) of the second heart sound (S2) into aortic and pulmonary components is proposed. It recovers aortic (A2) and pulmonary (P2) waveforms, as well as their relative delays, by solving an alternating optimization problem on the set of S2 sounds, without the use of auxiliary ECG or respiration phase measurement data. This unsupervised and data-driven approach assumes that the A2 and P2 components maintain the same waveform across heartbeats and that the relative delay between onset of the components varies according to respiration phase. The proposed approach is applied to synthetic heart sounds and to real-world heart sounds from 43 patients. It improves over two state-of-the-art BSS approaches by 10% normalized root mean-squared error in the reconstruction of aortic and pulmonary components using synthetic heart sounds, demonstrates robustness to noise, and recovery of splitting delays. The detection of pulmonary hypertension (PH) in a Brazilian population is demonstrated by training a classifier on three scalar features from the recovered A2 and P2 waveforms, and this yields an auROC of 0.76.
- Open Access
ExplainFix: Explainable Spatially Fixed Deep Networks
Is there an initialization for deep networks that requires no learning? ExplainFix adopts two design principles: the "fixed filters" principle that all spatial filter weights of convolutional neural networks can be fixed at initialization and never learned, and the "nimbleness" principle that only few network parameters suffice. We contribute (a) visual model-based explanations, (b) speed and accuracy gains, and (c) novel tools for deep convolutional neural networks. ExplainFix gives key insights that spatially fixed networks should have a steered initialization, that spatial convolution layers tend to prioritize low frequencies, and that most network parameters are not necessary in spatially fixed models. ExplainFix models have up to 100x fewer spatial filter kernels than fully learned models and matching or improved accuracy. Our extensive empirical analysis confirms that ExplainFix guarantees nimbler models (train up to 17\% faster with channel pruning), matching or improved predictive performance (spanning 13 distinct baseline models, four architectures and two medical image datasets), improved robustness to larger learning rate, and robustness to varying model size. We are first to demonstrate that all spatial filters in state-of-the-art convolutional deep networks can be fixed at initialization, not learned.
Open AccessExplainFix: Explainable Spatially Fixed Deep Networks
Is there an initialization for deep networks that requires no learning? ExplainFix adopts two design principles: the "fixed filters" principle that all spatial filter weights of convolutional neural networks can be fixed at initialization and never learned, and the "nimbleness" principle that only few network parameters suffice. We contribute (a) visual model-based explanations, (b) speed and accuracy gains, and (c) novel tools for deep convolutional neural networks. ExplainFix gives key insights that spatially fixed networks should have a steered initialization, that spatial convolution layers tend to prioritize low frequencies, and that most network parameters are not necessary in spatially fixed models. ExplainFix models have up to 100x fewer spatial filter kernels than fully learned models and matching or improved accuracy. Our extensive empirical analysis confirms that ExplainFix guarantees nimbler models (train up to 17\% faster with channel pruning), matching or improved predictive performance (spanning 13 distinct baseline models, four architectures and two medical image datasets), improved robustness to larger learning rate, and robustness to varying model size. We are first to demonstrate that all spatial filters in state-of-the-art convolutional deep networks can be fixed at initialization, not learned.
- Open Access
- 11 March 2023
- Published by Wiley in WIREs Data Mining and Knowledge Discovery
- Vol. 13 (4)
DeepFixCX: Explainable privacy‐preserving image compression for medical image analysis
Explanations of a model's biases or predictions are essential to medical image analysis. Yet, explainable machine learning approaches for medical image analysis are challenged by needs to preserve privacy of patient data, and by current trends in deep learning to use unsustainably large models and large datasets. We propose DeepFixCX for explainable and privacy‐preserving medical image compression that is nimble and performant. We contribute a review of the field and a conceptual framework for simultaneous privacy and explainability via tools of compression. DeepFixCX compresses images without learning by removing or obscuring spatial and edge information. DeepFixCX is ante‐hoc explainable and gives privatized post hoc explanations of spatial and edge bias without accessing the original image. DeepFixCX privatizes images to prevent image reconstruction and mitigate patient re‐identification. DeepFixCX is nimble. Compression can occur on a laptop CPU or GPU to compress and privatize 1700 images per second of size 320 × 320. DeepFixCX enables use of low memory MLP classifiers for vision data; permitting small performance loss gives end‐to‐end MLP performance over 70× faster and batch size over 100× larger. DeepFixCX consistently improves predictive classification performance of a Deep Neural Network (DNN) by 0.02 AUC ROC on Glaucoma and Cervix Type detection datasets, and can improve multi‐label chest x‐ray classification performance in seven of 10 tested settings. In all three datasets, compression to less than 5% of original number of pixels gives matching or improved performance. Our main novelty is to define an explainability versus privacy problem and address it with lossy compression.This article is categorized under: Fundamental Concepts of Data and Knowledge > Explainable AI Commercial, Legal, and Ethical Issues > Security and Privacy Fundamental Concepts of Data and Knowledge > Big Data Mining
- 11 March 2023
- Published by Wiley in WIREs Data Mining and Knowledge Discovery
- Vol. 13 (4)
Open AccessDeepFixCX: Explainable privacy‐preserving image compression for medical image analysis
Explanations of a model's biases or predictions are essential to medical image analysis. Yet, explainable machine learning approaches for medical image analysis are challenged by needs to preserve privacy of patient data, and by current trends in deep learning to use unsustainably large models and large datasets. We propose DeepFixCX for explainable and privacy‐preserving medical image compression that is nimble and performant. We contribute a review of the field and a conceptual framework for simultaneous privacy and explainability via tools of compression. DeepFixCX compresses images without learning by removing or obscuring spatial and edge information. DeepFixCX is ante‐hoc explainable and gives privatized post hoc explanations of spatial and edge bias without accessing the original image. DeepFixCX privatizes images to prevent image reconstruction and mitigate patient re‐identification. DeepFixCX is nimble. Compression can occur on a laptop CPU or GPU to compress and privatize 1700 images per second of size 320 × 320. DeepFixCX enables use of low memory MLP classifiers for vision data; permitting small performance loss gives end‐to‐end MLP performance over 70× faster and batch size over 100× larger. DeepFixCX consistently improves predictive classification performance of a Deep Neural Network (DNN) by 0.02 AUC ROC on Glaucoma and Cervix Type detection datasets, and can improve multi‐label chest x‐ray classification performance in seven of 10 tested settings. In all three datasets, compression to less than 5% of original number of pixels gives matching or improved performance. Our main novelty is to define an explainability versus privacy problem and address it with lossy compression.This article is categorized under: Fundamental Concepts of Data and Knowledge > Explainable AI Commercial, Legal, and Ethical Issues > Security and Privacy Fundamental Concepts of Data and Knowledge > Big Data Mining
- Open Access
- 25 November 2022
- Published by Wiley in WIREs Data Mining and Knowledge Discovery
- Vol. 13 (2)
ExplainFix: Explainable spatially fixed deep networks
Is there an initialization for deep networks that requires no learning? ExplainFix adopts two design principles: the “fixed filters” principle that all spatial filter weights of convolutional neural networks can be fixed at initialization and never learned, and the “nimbleness” principle that only few network parameters suffice. We contribute (a) visual model‐based explanations, (b) speed and accuracy gains, and (c) novel tools for deep convolutional neural networks. ExplainFix gives key insights that spatially fixed networks should have a steered initialization, that spatial convolution layers tend to prioritize low frequencies, and that most network parameters are not necessary in spatially fixed models. ExplainFix models have up to ×100 fewer spatial filter kernels than fully learned models and matching or improved accuracy. Our extensive empirical analysis confirms that ExplainFix guarantees nimbler models (train up to 17% faster with channel pruning), matching or improved predictive performance (spanning 13 distinct baseline models, four architectures and two medical image datasets), improved robustness to larger learning rate, and robustness to varying model size. We are first to demonstrate that all spatial filters in state‐of‐the‐art convolutional deep networks can be fixed at initialization, not learned.This article is categorized under: Technologies > Machine Learning Fundamental Concepts of Data and Knowledge > Explainable AI Fundamental Concepts of Data and Knowledge > Key Design Issues in Data Mining
- 25 November 2022
- Published by Wiley in WIREs Data Mining and Knowledge Discovery
- Vol. 13 (2)
Open AccessExplainFix: Explainable spatially fixed deep networks
Is there an initialization for deep networks that requires no learning? ExplainFix adopts two design principles: the “fixed filters” principle that all spatial filter weights of convolutional neural networks can be fixed at initialization and never learned, and the “nimbleness” principle that only few network parameters suffice. We contribute (a) visual model‐based explanations, (b) speed and accuracy gains, and (c) novel tools for deep convolutional neural networks. ExplainFix gives key insights that spatially fixed networks should have a steered initialization, that spatial convolution layers tend to prioritize low frequencies, and that most network parameters are not necessary in spatially fixed models. ExplainFix models have up to ×100 fewer spatial filter kernels than fully learned models and matching or improved accuracy. Our extensive empirical analysis confirms that ExplainFix guarantees nimbler models (train up to 17% faster with channel pruning), matching or improved predictive performance (spanning 13 distinct baseline models, four architectures and two medical image datasets), improved robustness to larger learning rate, and robustness to varying model size. We are first to demonstrate that all spatial filters in state‐of‐the‐art convolutional deep networks can be fixed at initialization, not learned.This article is categorized under: Technologies > Machine Learning Fundamental Concepts of Data and Knowledge > Explainable AI Fundamental Concepts of Data and Knowledge > Key Design Issues in Data Mining
- Open Access
- 8 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 28333-28347
Privacy-Preserving Case-Based Explanations: Enabling Visual Interpretability by Protecting Privacy
Deep Learning achieves state-of-the-art results in many domains, yet its black-box nature limits its application to real-world contexts. An intuitive way to improve the interpretability of Deep Learning models is by explaining their decisions with similar cases. However, case-based explanations cannot be used in contexts where the data exposes personal identity, as they may compromise the privacy of individuals. In this work, we identify the main limitations and challenges in the anonymization of case-based explanations of image data through a survey on case-based interpretability and image anonymization methods. We empirically analyze the anonymization methods in regards to their capacity to remove personally identifiable information while preserving relevant semantic properties of the data. Through this analysis, we conclude that most privacy-preserving methods are not sufficiently good to be applied to case-based explanations. To promote research on this topic, we formalize the privacy protection of visual case-based explanations as a multi-objective problem to preserve privacy, intelligibility, and relevant explanatory evidence regarding a predictive task. We empirically verify the potential of interpretability saliency maps as qualitative evaluation tools for anonymization. Finally, we identify and propose new lines of research to guide future work in the generation of privacy-preserving case-based explanations.
- 8 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 28333-28347
Open AccessPrivacy-Preserving Case-Based Explanations: Enabling Visual Interpretability by Protecting Privacy
Deep Learning achieves state-of-the-art results in many domains, yet its black-box nature limits its application to real-world contexts. An intuitive way to improve the interpretability of Deep Learning models is by explaining their decisions with similar cases. However, case-based explanations cannot be used in contexts where the data exposes personal identity, as they may compromise the privacy of individuals. In this work, we identify the main limitations and challenges in the anonymization of case-based explanations of image data through a survey on case-based interpretability and image anonymization methods. We empirically analyze the anonymization methods in regards to their capacity to remove personally identifiable information while preserving relevant semantic properties of the data. Through this analysis, we conclude that most privacy-preserving methods are not sufficiently good to be applied to case-based explanations. To promote research on this topic, we formalize the privacy protection of visual case-based explanations as a multi-objective problem to preserve privacy, intelligibility, and relevant explanatory evidence regarding a predictive task. We empirically verify the potential of interpretability saliency maps as qualitative evaluation tools for anonymization. Finally, we identify and propose new lines of research to guide future work in the generation of privacy-preserving case-based explanations.