Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aleksander Leicht has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Energy and economic benefits of high-efficiency line-start permanent magnet synchronous motors in mining applications

    by Adam Gozdowiak, Aleksander Leicht

    The paper analyses the application of high-efficiency line-start permanent magnet synchronous motors (LSPMSMs) as replacements for conventional induction and synchronous machines in mining drives. Conveyor belts, ventilation fans, drainage pumps, and mill drives are considered. The results show significantly higher efficiency and power factor, full interchangeability, and annual cost savings ranging from about 1,700 EUR to over 82,000 EUR. The study confirms the technical suitability and economic benefits of LSPMSMs in mining applications.

  • Open Access

    Reactive Power Compensation for Single-Phase AC Motors Using Integral Power Theory

    by Grzegorz Kosobudzki, Daniel Dusza, Marek Pawel Ciurys, Aleksander Leicht

    The paper investigates an alternative approach to measuring and compensating reactive power in electric machines, particularly under non-sinusoidal voltage and current waveforms. Traditional power definitions, such as those introduced by Budeanu and Fryze, as well as the power triangle, are discussed alongside integral definitions of reactive power, which account for waveform distortions. This approach is novel and has not been previously applied in the context of electric machines. A digital algorithm for reactive power calculation, based on the integral definition, is proposed. It requires minimal computational resources and is easy to implement. Experimental measurements conducted on a single-phase induction motor demonstrate the impact of capacitive compensation on current waveforms. The results confirm the validity of the adopted definition of reactive power. With full reactive power compensation, the RMS value of the current drawn by the motor is minimized, which is not always the case with the classical approach to improving the power factor. The findings highlight the importance of accurate reactive power measurement and compensation in enhancing the performance and energy efficiency of electrical machines. The proposed approach is applicable not only to single-phase motors but also more broadly in determining the reactive power drawn by electric machines and in measuring electric energy, particularly in the presence of distorted voltages and currents.


  • Open Access

    Performance Characteristics of Single-Phase Self-Excited Induction Generators with an Iron Core of Various Non-Grain Oriented Electrical Sheets

    by Krzysztof Makowski, Aleksander Leicht

    This paper deals with the computation of the performance characteristics of the single-phase self-excited induction generator by field–circuit method. It presents and compares previously unpublished results—self-excitation and no-load characteristics of the generator for different rotor speeds, and complete load steady-state performance characteristics for various types of the core materials. The discrepancies between the performance characteristics of the generator for the catalog’s magnetization curves of different types of electrical sheets and for an actual magnetic core of the generator for self-excitation transients and load steady-state are presented. The results may be useful for designing new constructions of single-phase self-excited induction generators.


  • Influence of shape and material of rotor bars on performance characteristics of single-phase self-excited induction generators

    by Aleksander Leicht, Krzysztof Makowski

    Purpose: The purpose of the paper is to present an analysis of an influence of shape and material of rotor bars on the process of self-excitation and performance characteristics of single-phase, self-excited induction generator (SP-SEIG). Design/methodology/approach: The presented analysis is based on the results of transient simulations of SP-SEIG performed with the use of field-circuit model of the machine. Four various shapes of the rotor bars and two different conductor materials were investigated. The results for the base model with rounded trapezoidal rotor slots were validated by measurements. Findings: An improvement of the performance characteristics – the extension of the stable operating range of the generator – was obtained for rectangular copper rotor bars. The improvement is the result of strong skin effect in the squirrel rotor cage. Application of round rotor slots results in shorter time of voltage build-up during the self-excitation of the generator caused by less apparent deep bar effect in round bars. Originality/value: The originality of the paper is the application of the copper rotor cage in the single-phase, self-excited induction generator. Its use is beneficial, as it allows for extension of the range of stable operating range. The results may be used for designing new constructions of the single-phase, self-excited induction generators, as well as the constructions based on general purpose single-phase induction motors.


  • Behaviour of single-phase self-excited induction generator during short-circuit at terminals

    by Krzysztof Makowski, Aleksander Leicht

    Purpose: The purpose of this paper is to present analysis of short-circuit transients in a single-phase self-excited induction generator (SP-SEIG) for different capacitor topologies. Design/methodology/approach: The paper presents field analysis of the short-circuit problem in the SP-SEIG on the base of two-dimensional field-circuit model of the generator. Findings: The carried-out field computations of the tested SP-SEIG show that the self-excited induction generator is intrinsically protected from the results of sudden short-circuit, as output voltage and current drop rapidly to zero. Short-circuit is a problem when a series capacitor is used to improve output voltage regulation. Experimental results show that re-excitation of the generator is possible after the short-circuit is removed. Originality/value: The originality of the paper is the presented analysis of short-circuit transients at terminals of SP-SEIG. A finite elements method-based field circuit model was used. The simulation results were validated by the measurements conducted on a laboratory test setup.


  • Open Access

    Field-circuit analysis and measurements of a single-phase self-excited induction generator

    by Krzysztof Makowski, Aleksander Leicht

    The paper deals with a single-phase induction machine operating as a stand-alone self-excited single-phase induction generator for generation of electrical energy from renewable energy sources. By changing number of turns and size of wires in the auxiliary stator winding, an improvement of performance characteristics of the generator were obtained as regards no-load and load voltage of the stator windings as well as stator winding currents of the generator. Field-circuit simulation models of the generator were developed using Flux2D software package for the generator with shunt capacitor in the main stator winding. The obtained results have been validated experimentally at the laboratory setup using the single-phase capacitor induction motor of 1.1 kW rated power and 230 V voltage as a base model of the generator.


  • Modeling of short-circuit transients at terminals of a single-phase self-excited induction generator

    by Krzysztof Makowski, Aleksander Leicht

    In the paper, sudden short-circuit transients at terminals of an autonomous single-phase induction generator were simulated using field-circuit 2D model of the single-phase induction generator. The transients at terminals were calculated for different configurations of capacitors in stator windings. Some experimental results showing re-excitation of the stator voltage after sudden short-circuit at terminals under no-load operation of the generator were also presented for the generator with only a capacitor connected to excitation stator winding.


  • Field-circuit evaluation of performance characteristics of a single-phase self-excited induction generator

    by Krzysztof Makowski, Aleksander Leicht

    The paper deals with a single-phase induction machine operating as a stand-alone self-excited single-phase induction generator for generation of electrical energy from renewably energy sources. By changing number of turns and size of wires in the auxiliary stator winding, considerable improvement of performance characteristics of the generator were obtained as regards no-load and load voltage of the stator windings as well as stator winding currents of the generator. Field-circuit simulation models of the generator were developed using Flux2D software package for parallel connected capacitor in the main stator winding. The obtained results have been validated experimentally at the laboratory setup using the single-phase capacitor induction motor of 1.1kW rated power and 230V voltage as a base model of the generator.


  • Analysis of self-excitation and performance characteristics of a single-phase self-excited induction generator by field-circuit method

    by Krzysztof Makowski, Aleksander Leicht

    Purpose: – The purpose of this paper is to present analysis of an influence of rotor slots opening on self-excitation process, terminal voltage and performance characteristics of the single-phase self-excited induction generator (SPSEIG). Design/methodology/approach: – The paper presents field analysis of the self-excitation problem in the SPSEIG and performance characteristics on the base of two-dimensional field-circuit model of the generator. Findings: – The carried out field computations of the tested SPSEIG with closed rotor slots showed that only an initial voltage across the excitation capacitor of about nominal value (230 V) causes successful self-excitation of the generator. It was also proved that the suitable opening of the rotor slots, beside remnant flux density in the rotor core, facilitates self-excitation in the generator. Since in working applications initially charging of the capacitor to almost nominal voltage may cause a problem, therefore employment of semi-closed rotor slots in the SPSEIG would be proper solution. Originality/value: – The conducted simulations, validated by laboratory tests showed that not only suitable excitation capacitor capacitance and rotor speed are needed to obtain desired terminal voltage of the generator, but also suitable initial voltage across the capacitor in auxiliary stator winding is very important and necessary for reliable self-excitation of the single-phase induction generator with closed rotor slots. The employment of semi-closed rotor slots in the SPSEIG makes the self-excitation more effective.