Mateus Damiani Monteiro
Research Subjects
Mateus Damiani Monteiro has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Euripedes Gomes de Carvalho Neto
Department of Neurology, Santa Casa de Misericórdia de Porto Alegre, Brazil
4 shared publications - Carlos Roberto Mello Rieder
Universidade Federal de Ciências da Saúde de Porto Alegre, Departamento de Neurologia, Porto Alegre RS, Brazil
3 shared publications - Diogo C. Haussen
Department of Neurology, Marcus Stroke and Neuroscience Center, Grady Memorial Hospital, Emory University School of Medicine, Atlanta, Ga
3 shared publications Aqueel Pabaney
Marcus Stroke & Neuroscience Center, Grady Memorial Hospital-Atlanta, GA, USA
2 shared publications- Jaydevsinh Dolia
Emory University School of Medicine / Grady Memorial Hospital Marcus Stroke and Neuroscience Center
2 shared publications - Jonathan A. Grossberg
Neurosurgery, Emory University School of Medicine, Atlanta, Georgia, USA
2 shared publications
Latest Publications
- 13 October 2026
- Published by Wolters Kluwer Health in Neurology
- Vol. 107 (7)
Teaching NeuroImage: Mees Lines as a Clinical Clue to Arsenic Poisoning
- 13 October 2026
- Published by Wolters Kluwer Health in Neurology
- Vol. 107 (7)
Teaching NeuroImage: Mees Lines as a Clinical Clue to Arsenic Poisoning
- Open Access
- 13 August 2026
- Published by Georg Thieme Verlag KG in Arquivos de Neuro-Psiquiatria
- Vol. 84 (11) , 001-005
The whistle-smile reflex in Parkinson's disease: an exploratory case-control study
Parkinson's disease (PD) is a well-known neurodegenerative disease characterized by tremors, rigidity, and bradykinesia. In 1943, Frederic Hanes described the whistle-smile reflex (WSR), noting its absence in PD patients due to reduced facial movements. To assess the WSR's diagnostic performance. In the current cross-sectional study, we selected PD patients and healthy controls. They were filmed while asked to whistle, and a blinded physician assessed if the individuals smiled or not. Absence of smiling after whistling was considered a positive test. We stratified the smiling intensity into 4 groups. We calculated the odds ratio (OR) of the positive WSR in PD and asymptomatic patients, which was reported with CIs, sensitivity (SE), specificity (SP), positive predictive value (PPV), negative predictive value (NPV), and we plotted a receiver operating characteristic (ROC) curve. We identified 43 patients with PD (mean age = 63 ± 10 years; 30% of female subjects) and 44 asymptomatic controls (mean age = 64 ± 10 years; 51% of female subjects). The WSR test was positive in 35/43 PD cases versus 7/44 in the asymptomatic group (OR = 23.1; 95%CI = 7.6–70.5; SE = 81.4%; SP = 84.1%; PPV = 83.3%; NPV = 82.2%). When stratified considering the group with the least intense smile as a positive test, the test was positive in 42/43 PD cases versus 23/44 in the asymptomatic group (OR = 38.3; 95%CI = 4.8–303.7; SE = 97.7%; SP = 47.7%; PPV = 64.6%; NPV = 95.4%). The WSR test showed a good performance in identifying PD patients; it may complement the physical examination, and its result may be a useful finding during the assessment of a patient with PD.
- 13 August 2026
- Published by Georg Thieme Verlag KG in Arquivos de Neuro-Psiquiatria
- Vol. 84 (11) , 001-005
Open AccessThe whistle-smile reflex in Parkinson's disease: an exploratory case-control study
Parkinson's disease (PD) is a well-known neurodegenerative disease characterized by tremors, rigidity, and bradykinesia. In 1943, Frederic Hanes described the whistle-smile reflex (WSR), noting its absence in PD patients due to reduced facial movements. To assess the WSR's diagnostic performance. In the current cross-sectional study, we selected PD patients and healthy controls. They were filmed while asked to whistle, and a blinded physician assessed if the individuals smiled or not. Absence of smiling after whistling was considered a positive test. We stratified the smiling intensity into 4 groups. We calculated the odds ratio (OR) of the positive WSR in PD and asymptomatic patients, which was reported with CIs, sensitivity (SE), specificity (SP), positive predictive value (PPV), negative predictive value (NPV), and we plotted a receiver operating characteristic (ROC) curve. We identified 43 patients with PD (mean age = 63 ± 10 years; 30% of female subjects) and 44 asymptomatic controls (mean age = 64 ± 10 years; 51% of female subjects). The WSR test was positive in 35/43 PD cases versus 7/44 in the asymptomatic group (OR = 23.1; 95%CI = 7.6–70.5; SE = 81.4%; SP = 84.1%; PPV = 83.3%; NPV = 82.2%). When stratified considering the group with the least intense smile as a positive test, the test was positive in 42/43 PD cases versus 23/44 in the asymptomatic group (OR = 38.3; 95%CI = 4.8–303.7; SE = 97.7%; SP = 47.7%; PPV = 64.6%; NPV = 95.4%). The WSR test showed a good performance in identifying PD patients; it may complement the physical examination, and its result may be a useful finding during the assessment of a patient with PD.
- 21 January 2025
- Published by SAGE Publications in Interventional Neuroradiology
Combined technique versus stent-retriever alone: Interaction analysis of angioarchitectural and technical features
Introduction: We aimed to explore if anatomical and technical features could interact and favor the chances of reperfusion according to the treatment strategy: combined technique (CoT) of mechanical thrombectomy (MT) with contact aspiration and stent-retriever (SR) versus SR alone. Methods: Retrospective analysis of a prospective MT database for carotid terminus or MCA-M1 occlusion, first-line SR alone or CoT, and angiographic run with SR deployed on the first pass. The primary analysis involved the interaction between clinical and angiographic characteristics and first-line MT modality on first-pass effect (FPE; first pass eTICI2c-3). Results: A total of 300 consecutive patients were included (SR alone, n = 210 vs CoT, n = 90). Baseline characteristics as well as baseline ASPECTS, CTA collateral score, clot burden score, FPE were similar amongst groups. Anatomical and technical variables (presence of reperfusion channel, frequency of SR position in dominant MCA division, angle of device-clot interaction, and clot length) were comparable between groups, with exception of SR opening (diameter across the occlusion) and length of SR purchase beyond the clot being more pronounced in the SR group. None of the clinical, anatomical, and technical factors were found to have an interaction with the MT strategy on the chances of FPE ( P-interaction ≥ 0.001). Multivariable logistic regression showed that clot burden score ≥8 (aOR 3.02, P = 0.003), angle of interaction (aOR 1.01, P = 0.015) but not the MT modality were associated with FPE. Conclusion: No specific anatomical or technical features were observed to predispose to benefit when combining contact aspiration and SR thrombectomy. Clot burden score ≥ 8 and angle of interaction were independent factors associated with FPE. Additional studies are warranted.
- 21 January 2025
- Published by SAGE Publications in Interventional Neuroradiology
Combined technique versus stent-retriever alone: Interaction analysis of angioarchitectural and technical features
Introduction: We aimed to explore if anatomical and technical features could interact and favor the chances of reperfusion according to the treatment strategy: combined technique (CoT) of mechanical thrombectomy (MT) with contact aspiration and stent-retriever (SR) versus SR alone. Methods: Retrospective analysis of a prospective MT database for carotid terminus or MCA-M1 occlusion, first-line SR alone or CoT, and angiographic run with SR deployed on the first pass. The primary analysis involved the interaction between clinical and angiographic characteristics and first-line MT modality on first-pass effect (FPE; first pass eTICI2c-3). Results: A total of 300 consecutive patients were included (SR alone, n = 210 vs CoT, n = 90). Baseline characteristics as well as baseline ASPECTS, CTA collateral score, clot burden score, FPE were similar amongst groups. Anatomical and technical variables (presence of reperfusion channel, frequency of SR position in dominant MCA division, angle of device-clot interaction, and clot length) were comparable between groups, with exception of SR opening (diameter across the occlusion) and length of SR purchase beyond the clot being more pronounced in the SR group. None of the clinical, anatomical, and technical factors were found to have an interaction with the MT strategy on the chances of FPE ( P-interaction ≥ 0.001). Multivariable logistic regression showed that clot burden score ≥8 (aOR 3.02, P = 0.003), angle of interaction (aOR 1.01, P = 0.015) but not the MT modality were associated with FPE. Conclusion: No specific anatomical or technical features were observed to predispose to benefit when combining contact aspiration and SR thrombectomy. Clot burden score ≥ 8 and angle of interaction were independent factors associated with FPE. Additional studies are warranted.
- 14 July 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (8) , 843-847
Carotid web catheter angiography hemodynamic parameters
Background Carotid web (CaW)-related contrast stagnation on digital subtraction angiography (DSA) may be a marker supporting the pathophysiological theory of stasis and thrombosis/embolization. We aim to assess the correlation between DSA hemodynamic parameters with CT angiography (CTA) structural measurements and clinical characteristics. Methods Cross-sectional analysis of consecutive patients with CaW who underwent CTA+DSA. DSA-derived hemodynamic parameters were calculated based on a region of interest at the carotid bulb (time–density curves; TDC). The correlation between duration of contrast stagnation with CaW structural features and with clinical characteristics was evaluated with a mixed effects model. Results Sixty patients of mean±SD age 52.2±10.3 years were included, of whom 38 (63.3%) were women, 51 (85%) were black, and 59 (98.3%) had symptomatic lesions. The median CaW base was 2.46 mm (range 1.95–3.76), length 2.7 mm (range 2.15–3.96), thickness (length/base) 1.05 (IQR 0.81–1.36), caudal angle 31.93° (IQR 22.35–43.58), mean±SD distal angle 66.91±15.84°, pocket area 1.62 mm² (0.96–1.62), and pocket perimeter 6.03±2.6 mm. The TDC consistently showed an initial fast decay from the peak concentration followed by a plateau with a negative exponential pattern. The median stagnation time from peak density to 80% contrast clearance was 2.91 s (range 1.81–4.94). No significant associations were observed between the stagnation time and CaW CTA structural measurements (length/base/thickness, caudal and cranial angles web surface angles, web pocket area/perimeter) or clinical characteristics. Conclusions A negative exponential pattern in the DSA contrast clearance of the CaW pocket was observed. There were no morphological or clinical features clearly associated with the duration of contrast stagnation on DSA. The hemodynamic disruption caused by CaW and its thrombotic risk may not be appropriately measured by contrast stagnation time.
- 14 July 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (8) , 843-847
Carotid web catheter angiography hemodynamic parameters
Background Carotid web (CaW)-related contrast stagnation on digital subtraction angiography (DSA) may be a marker supporting the pathophysiological theory of stasis and thrombosis/embolization. We aim to assess the correlation between DSA hemodynamic parameters with CT angiography (CTA) structural measurements and clinical characteristics. Methods Cross-sectional analysis of consecutive patients with CaW who underwent CTA+DSA. DSA-derived hemodynamic parameters were calculated based on a region of interest at the carotid bulb (time–density curves; TDC). The correlation between duration of contrast stagnation with CaW structural features and with clinical characteristics was evaluated with a mixed effects model. Results Sixty patients of mean±SD age 52.2±10.3 years were included, of whom 38 (63.3%) were women, 51 (85%) were black, and 59 (98.3%) had symptomatic lesions. The median CaW base was 2.46 mm (range 1.95–3.76), length 2.7 mm (range 2.15–3.96), thickness (length/base) 1.05 (IQR 0.81–1.36), caudal angle 31.93° (IQR 22.35–43.58), mean±SD distal angle 66.91±15.84°, pocket area 1.62 mm² (0.96–1.62), and pocket perimeter 6.03±2.6 mm. The TDC consistently showed an initial fast decay from the peak concentration followed by a plateau with a negative exponential pattern. The median stagnation time from peak density to 80% contrast clearance was 2.91 s (range 1.81–4.94). No significant associations were observed between the stagnation time and CaW CTA structural measurements (length/base/thickness, caudal and cranial angles web surface angles, web pocket area/perimeter) or clinical characteristics. Conclusions A negative exponential pattern in the DSA contrast clearance of the CaW pocket was observed. There were no morphological or clinical features clearly associated with the duration of contrast stagnation on DSA. The hemodynamic disruption caused by CaW and its thrombotic risk may not be appropriately measured by contrast stagnation time.
- 23 May 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (5) , 539-545
Development and validation of a SCORing systEm for pre-thrombectomy diagnosis of IntraCranial Atherosclerotic Disease (Score-ICAD)
Background Early identification of intracranial atherosclerotic disease (ICAD) may impact the management of patients undergoing mechanical thrombectomy (MT). We sought to develop and validate a scoring system for pre-thrombectomy diagnosis of ICAD in anterior circulation large vessel/distal medium vessel occlusion strokes (LVOs/DMVOs). Methods Retrospective analysis of two prospectively maintained comprehensive stroke center databases including patients with anterior circulation occlusions spanning 2010–22 (development cohort) and 2018–22 (validation cohort). ICAD cases were matched for age and sex (1:1) to non-ICAD controls. Results Of 2870 MTs within the study period, 348 patients were included in the development cohort: 174 anterior circulation ICAD (6% of 2870 MTs) and 174 controls. Multivariable analysis β coefficients led to a 20 point scale: absence of atrial fibrillation (5); vascular risk factor burden (1) for each of hypertension, diabetes, smoking, and hyperlipidemia; multifocal single artery stenoses on CT angiography (3); absence of territorial cortical infarct (3); presence of borderzone infarct (3); or ipsilateral carotid siphon calcification (2). The validation cohort comprised 56 ICAD patients (4.1% of 1359 MTs): 56 controls. Area under the receiver operating characteristic curve was 0.88 (0.84–0.91) and 0.82 (0.73–0.89) in the development and validation cohorts, respectively. Calibration slope and intercept showed a good fit for the development cohort although with overestimated risk for the validation cohort. After intercept adjustment, the overestimation was corrected (intercept 0, 95% CI −0.5 to –0.5; slope 0.8, 95% CI 0.5 to 1.1). In the full cohort (n=414), ≥11 points showed the best performance for distinguishing ICAD from non-ICAD, with 0.71 (95% CI 0.65 to 0.78) sensitivity and 0.82 (95% CI 0.77 to 0.87) specificity, and 3.92 (95% CI 2.92 to 5.28) positive and 0.35 (95% CI 0.28 to 0.44) negative likelihood ratio. Scores ≥12 showed 90% specificity and 63% sensitivity. Conclusion The proposed scoring system for preprocedural diagnosis of ICAD LVOs and DMVOs presented satisfactory discrimination and calibration based on clinical and non-invasive radiological data.
- 23 May 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (5) , 539-545
Development and validation of a SCORing systEm for pre-thrombectomy diagnosis of IntraCranial Atherosclerotic Disease (Score-ICAD)
Background Early identification of intracranial atherosclerotic disease (ICAD) may impact the management of patients undergoing mechanical thrombectomy (MT). We sought to develop and validate a scoring system for pre-thrombectomy diagnosis of ICAD in anterior circulation large vessel/distal medium vessel occlusion strokes (LVOs/DMVOs). Methods Retrospective analysis of two prospectively maintained comprehensive stroke center databases including patients with anterior circulation occlusions spanning 2010–22 (development cohort) and 2018–22 (validation cohort). ICAD cases were matched for age and sex (1:1) to non-ICAD controls. Results Of 2870 MTs within the study period, 348 patients were included in the development cohort: 174 anterior circulation ICAD (6% of 2870 MTs) and 174 controls. Multivariable analysis β coefficients led to a 20 point scale: absence of atrial fibrillation (5); vascular risk factor burden (1) for each of hypertension, diabetes, smoking, and hyperlipidemia; multifocal single artery stenoses on CT angiography (3); absence of territorial cortical infarct (3); presence of borderzone infarct (3); or ipsilateral carotid siphon calcification (2). The validation cohort comprised 56 ICAD patients (4.1% of 1359 MTs): 56 controls. Area under the receiver operating characteristic curve was 0.88 (0.84–0.91) and 0.82 (0.73–0.89) in the development and validation cohorts, respectively. Calibration slope and intercept showed a good fit for the development cohort although with overestimated risk for the validation cohort. After intercept adjustment, the overestimation was corrected (intercept 0, 95% CI −0.5 to –0.5; slope 0.8, 95% CI 0.5 to 1.1). In the full cohort (n=414), ≥11 points showed the best performance for distinguishing ICAD from non-ICAD, with 0.71 (95% CI 0.65 to 0.78) sensitivity and 0.82 (95% CI 0.77 to 0.87) specificity, and 3.92 (95% CI 2.92 to 5.28) positive and 0.35 (95% CI 0.28 to 0.44) negative likelihood ratio. Scores ≥12 showed 90% specificity and 63% sensitivity. Conclusion The proposed scoring system for preprocedural diagnosis of ICAD LVOs and DMVOs presented satisfactory discrimination and calibration based on clinical and non-invasive radiological data.
- Open Access
- 1 October 2022
- Published by Georg Thieme Verlag KG in Arquivos de Neuro-Psiquiatria
- Vol. 80 (10) , 1075-1076
The whistle-smile reflex: a missed sign
In this paper, we present a historical review of the whistle-smile reflex, a semiological sign missed in the literature and clinical practice.
- 1 October 2022
- Published by Georg Thieme Verlag KG in Arquivos de Neuro-Psiquiatria
- Vol. 80 (10) , 1075-1076
Open AccessThe whistle-smile reflex: a missed sign
In this paper, we present a historical review of the whistle-smile reflex, a semiological sign missed in the literature and clinical practice.
- Open Access
- 1 January 2019
- Published by Taylor & Francis in Prion
- Vol. 13 (1) , 156-159
The worst is yet to come: probable sporadic Creutzfeldt–Jakob disease in a well-controlled HIV patient
We describe a case of probable sporadic Creutzfeldt–Jakob disease in the setting of well-controlled HIV and discuss whether exist, in fact, HIV-related factors that may predispose to the development of prion disease. To the best of our knowledge, this is the third report of this association.
- 1 January 2019
- Published by Taylor & Francis in Prion
- Vol. 13 (1) , 156-159
Open AccessThe worst is yet to come: probable sporadic Creutzfeldt–Jakob disease in a well-controlled HIV patient
We describe a case of probable sporadic Creutzfeldt–Jakob disease in the setting of well-controlled HIV and discuss whether exist, in fact, HIV-related factors that may predispose to the development of prion disease. To the best of our knowledge, this is the third report of this association.