Raphael Batista
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Raphael Batista has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
UFMG – Universidade Federal de Minas Gerais
5 shared publicationsClever Pereira
3 shared publicationsGeraldo Rodrigues Silveira Neto
3 shared publicationsGeraldo Silveira Neto
3 shared publicationsMarcos Roberto de Araújo
3 shared publications- Carlos Ermidio Ferreira Caetano
UFMG, Av. Antonio Carlos 6627,Graduate Program in Electrical Engineering,Belo Horizonte,MG,Brazil,31270-901
2 shared publications
Latest Publications
- 28 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 64 (6) , 2292-2295
Assessment of Frequency-Dependent Parameters of Stratified Soils for Lightning Response of Earth Electrodes
Typically, the frequency dependence of soil parameters is predicted by models or formulas that assume a uniform soil, although it usually presents a stratified structure. This work develops analytical expressions that allow to evaluating of the errors associated with the uniform soil hypothesis, in comparison with the hypothesis of a two-layered soil, taking as reference a field methodology for measuring the variation of soil parameters with frequency. The results suggest that in the case of a stratified soil, the frequency dependence of its parameters can be considered individually for each layer.
- 28 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 64 (6) , 2292-2295
Assessment of Frequency-Dependent Parameters of Stratified Soils for Lightning Response of Earth Electrodes
Typically, the frequency dependence of soil parameters is predicted by models or formulas that assume a uniform soil, although it usually presents a stratified structure. This work develops analytical expressions that allow to evaluating of the errors associated with the uniform soil hypothesis, in comparison with the hypothesis of a two-layered soil, taking as reference a field methodology for measuring the variation of soil parameters with frequency. The results suggest that in the case of a stratified soil, the frequency dependence of its parameters can be considered individually for each layer.
- 1 March 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 180
A study of grounding arrangements composed by vertical electrodes for two-layered stratified soil models
- 1 March 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 180
A study of grounding arrangements composed by vertical electrodes for two-layered stratified soil models
- 1 December 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 177
A practical approach to estimate grounding impedance of a vertical rod in a two-layer soil
- 1 December 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 177
A practical approach to estimate grounding impedance of a vertical rod in a two-layer soil
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
A Vertical Grounding Arrangement that Diminishes Impulse Coefficient in a Two-Layered Soil
This paper presents a vertical grounding mesh to transmission line (TL) towers for use in two-layered soils, where the second-layer has a lower resistivity compared to the first. To a better knowing about its behavior, a comparison with horizontal arrangement composed by counterpoise cables, for critical soils from a 230 kV TL, is realized focusing in impulse coefficient parameter. A first analysis of the procedure based on TL-theory with electromagnetic (EM) method is made and an evaluation of homogenous soil for the arrangements is realized. The results indicate a lower grounding resistance and impulsive impedance for the proposed vertical option compared to horizontal arrangement, using much less conductor material and presenting a margin to reduce such parameters due to the distance to effective length.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
A Vertical Grounding Arrangement that Diminishes Impulse Coefficient in a Two-Layered Soil
This paper presents a vertical grounding mesh to transmission line (TL) towers for use in two-layered soils, where the second-layer has a lower resistivity compared to the first. To a better knowing about its behavior, a comparison with horizontal arrangement composed by counterpoise cables, for critical soils from a 230 kV TL, is realized focusing in impulse coefficient parameter. A first analysis of the procedure based on TL-theory with electromagnetic (EM) method is made and an evaluation of homogenous soil for the arrangements is realized. The results indicate a lower grounding resistance and impulsive impedance for the proposed vertical option compared to horizontal arrangement, using much less conductor material and presenting a margin to reduce such parameters due to the distance to effective length.