Honorata Hafke-Dys
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Honorata Hafke-Dys has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Anna Preis
Institute of Acoustics, Faculty of Physics, Adam Mickiewicz University, 61-712 Poznań, Poland
11 shared publications Tomasz Kaczmarek
Adam Mickiewicz Univ, Inst Acoust, Umultowska 85, PL-61114 Poznan, Poland
6 shared publicationsJędrzej Kociński
Institute of Acoustics, Faculty of Physics, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego, Poland
4 shared publications- Paweł Kleka
Faculty of Psychology and Cognitive Science, Adam Mickiewicz University, Poznan, Poland
4 shared publications Anna Bręborowicz
Department of Pediatric Pneumonology, Allergology and Clinical Immunology, K. Jonscher Clinical Hospital in Poznań, Poznań University of Medical Sciences, Poland, Szpitalna, Poland
3 shared publicationsRiccardo Belluzzo
3 shared publications
Latest Publications
- Open Access
- 12 August 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (8) , e0220606
The accuracy of lung auscultation in the practice of physicians and medical students
Auscultation is one of the first examinations that a patient is subjected to in a GP’s office, especially in relation to diseases of the respiratory system. However it is a highly subjective process and depends on the physician’s ability to interpret the sounds as determined by his/her psychoacoustical characteristics. Here, we present a cross-sectional assessment of the skills of physicians of different specializations and medical students in the classification of respiratory sounds in children. 185 participants representing different medical specializations took part in the experiment. The experiment comprised 24 respiratory system auscultation sounds. The participants were tasked with listening to, and matching the sounds with provided descriptions of specific sound classes. The results revealed difficulties in both the recognition and description of respiratory sounds. The pulmonologist group was found to perform significantly better than other groups in terms of number of correct answers. We also found that performance significantly improved when similar sound classes were grouped together into wider, more general classes. These results confirm that ambiguous identification and interpretation of sounds in auscultation is a generic issue which should not be neglected as it can potentially lead to inaccurate diagnosis and mistreatment. Our results lend further support to the already widespread acknowledgment of the need to standardize the nomenclature of auscultation sounds (according to European Respiratory Society, International Lung Sounds Association and American Thoracic Society). In particular, our findings point towards important educational challenges in both theory (nomenclature) and practice (training).
- 12 August 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (8) , e0220606
Open AccessThe accuracy of lung auscultation in the practice of physicians and medical students
Auscultation is one of the first examinations that a patient is subjected to in a GP’s office, especially in relation to diseases of the respiratory system. However it is a highly subjective process and depends on the physician’s ability to interpret the sounds as determined by his/her psychoacoustical characteristics. Here, we present a cross-sectional assessment of the skills of physicians of different specializations and medical students in the classification of respiratory sounds in children. 185 participants representing different medical specializations took part in the experiment. The experiment comprised 24 respiratory system auscultation sounds. The participants were tasked with listening to, and matching the sounds with provided descriptions of specific sound classes. The results revealed difficulties in both the recognition and description of respiratory sounds. The pulmonologist group was found to perform significantly better than other groups in terms of number of correct answers. We also found that performance significantly improved when similar sound classes were grouped together into wider, more general classes. These results confirm that ambiguous identification and interpretation of sounds in auscultation is a generic issue which should not be neglected as it can potentially lead to inaccurate diagnosis and mistreatment. Our results lend further support to the already widespread acknowledgment of the need to standardize the nomenclature of auscultation sounds (according to European Respiratory Society, International Lung Sounds Association and American Thoracic Society). In particular, our findings point towards important educational challenges in both theory (nomenclature) and practice (training).
- 30 May 2019
- Published by Springer Nature
- p. 31-35
Fully Interactive Lungs Auscultation with AI Enabled Digital Stethoscope
- 30 May 2019
- Published by Springer Nature
- p. 31-35
Fully Interactive Lungs Auscultation with AI Enabled Digital Stethoscope
- Open Access
- 29 March 2019
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 178 (6) , 883-890
Practical implementation of artificial intelligence algorithms in pulmonary auscultation examination
Lung auscultation is an important part of a physical examination. However, its biggest drawback is its subjectivity. The results depend on the experience and ability of the doctor to perceive and distinguish pathologies in sounds heard via a stethoscope. This paper investigates a new method of automatic sound analysis based on neural networks (NNs), which has been implemented in a system that uses an electronic stethoscope for capturing respiratory sounds. It allows the detection of auscultatory sounds in four classes: wheezes, rhonchi, and fine and coarse crackles. In the blind test, a group of 522 auscultatory sounds from 50 pediatric patients were presented, and the results provided by a group of doctors and an artificial intelligence (AI) algorithm developed by the authors were compared. The gathered data show that machine learning (ML)–based analysis is more efficient in detecting all four types of phenomena, which is reflected in high values of recall (also called as sensitivity) and F1-score.
- 29 March 2019
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 178 (6) , 883-890
Open AccessPractical implementation of artificial intelligence algorithms in pulmonary auscultation examination
Lung auscultation is an important part of a physical examination. However, its biggest drawback is its subjectivity. The results depend on the experience and ability of the doctor to perceive and distinguish pathologies in sounds heard via a stethoscope. This paper investigates a new method of automatic sound analysis based on neural networks (NNs), which has been implemented in a system that uses an electronic stethoscope for capturing respiratory sounds. It allows the detection of auscultatory sounds in four classes: wheezes, rhonchi, and fine and coarse crackles. In the blind test, a group of 522 auscultatory sounds from 50 pediatric patients were presented, and the results provided by a group of doctors and an artificial intelligence (AI) algorithm developed by the authors were compared. The gathered data show that machine learning (ML)–based analysis is more efficient in detecting all four types of phenomena, which is reflected in high values of recall (also called as sensitivity) and F1-score.
- Open Access
- 1 January 2019
- Published by INSTICC
- p. 824-832
Interactive Lungs Auscultation with Reinforcement Learning Agent
- 1 January 2019
- Published by INSTICC
- p. 824-832
Open AccessInteractive Lungs Auscultation with Reinforcement Learning Agent
- 1 January 2018
- Published by Elsevier in Applied Acoustics
- Vol. 129, 190-203
The influence of audio-visual interactions on the annoyance ratings for wind turbines
- 1 January 2018
- Published by Elsevier in Applied Acoustics
- Vol. 129, 190-203
The influence of audio-visual interactions on the annoyance ratings for wind turbines
- Open Access
- 1 June 2016
- Published by Walter de Gruyter GmbH in Archives of Acoustics
- Vol. 41 (2) , 221-232
Noise Annoyance Caused by Amplitude Modulated Sounds Resembling the Main Characteristics of Temporal Wind Turbine Noise
Annoyance ratings for artificially created noises, resembling the main characteristics of temporal wind turbine noise, were studied by means of a listening experiment involving 21 participants with normal hearing. Three types of stimuli were examined: broadband noise (−4 dB/octave), noise generated by moving cars, and narrowband noise. All stimuli had the sound level fluctuations typical for wind turbine noise. The magnitude of the sound level fluctuations was measured in a quantitative way, by using the characteristics of amplitude modulated sound: modulation rate and modulation depth. Our aim was to examine how the modulation rate and the modulation depth influence the noise annoyance assessment of broadband and narrowband amplitude modulated noises. Three different modulation rates, 1, 2 and 4 Hz, and sound level fluctuations (a measure of the modulation depth), 3, 6, 9 dB, were applied to each type of stimuli (with exception of noise generated by the moving cars) and investigated. The participants in the listening experiment were presented with sound stimuli in laboratory conditions and asked to rate their annoyance on a numerical scale. The results have shown a significant difference between the investigated conditions. The effect was particularly strong between the annoyance judgments of different types of noise (narrow and broadband), and modulated versus unmodulated noises. Temporal fluctuations occurring in wind turbine noise are very pertinent to the perception of annoyance and could be responsible for its being a relatively annoying noise source. The obtained results were discussed and compared to the typical modulation rates and level changes that occur in recordings of real wind turbine noise.
- 1 June 2016
- Published by Walter de Gruyter GmbH in Archives of Acoustics
- Vol. 41 (2) , 221-232
Open AccessNoise Annoyance Caused by Amplitude Modulated Sounds Resembling the Main Characteristics of Temporal Wind Turbine Noise
Annoyance ratings for artificially created noises, resembling the main characteristics of temporal wind turbine noise, were studied by means of a listening experiment involving 21 participants with normal hearing. Three types of stimuli were examined: broadband noise (−4 dB/octave), noise generated by moving cars, and narrowband noise. All stimuli had the sound level fluctuations typical for wind turbine noise. The magnitude of the sound level fluctuations was measured in a quantitative way, by using the characteristics of amplitude modulated sound: modulation rate and modulation depth. Our aim was to examine how the modulation rate and the modulation depth influence the noise annoyance assessment of broadband and narrowband amplitude modulated noises. Three different modulation rates, 1, 2 and 4 Hz, and sound level fluctuations (a measure of the modulation depth), 3, 6, 9 dB, were applied to each type of stimuli (with exception of noise generated by the moving cars) and investigated. The participants in the listening experiment were presented with sound stimuli in laboratory conditions and asked to rate their annoyance on a numerical scale. The results have shown a significant difference between the investigated conditions. The effect was particularly strong between the annoyance judgments of different types of noise (narrow and broadband), and modulated versus unmodulated noises. Temporal fluctuations occurring in wind turbine noise are very pertinent to the perception of annoyance and could be responsible for its being a relatively annoying noise source. The obtained results were discussed and compared to the typical modulation rates and level changes that occur in recordings of real wind turbine noise.
- 1 January 2016
- Published by European Acoustics Association in Acta Acustica united with Acustica
- Vol. 102 (1) , 155-158
Violinists' Perceptions of and Motor Reactions to Fundamental Frequency Shifts Introduced in Auditory Feedback
- 1 January 2016
- Published by European Acoustics Association in Acta Acustica united with Acustica
- Vol. 102 (1) , 155-158
Violinists' Perceptions of and Motor Reactions to Fundamental Frequency Shifts Introduced in Auditory Feedback
- 1 January 2016
- Published by Institute of Noise Control Engineering (INCE) in Noise Control Engineering Journal
- Vol. 64 (1) , 34-43
Audio-visual interaction of environmental noise
- 1 January 2016
- Published by Institute of Noise Control Engineering (INCE) in Noise Control Engineering Journal
- Vol. 64 (1) , 34-43
Audio-visual interaction of environmental noise
- 1 August 2015
- Published by Elsevier in Science of The Total Environment
- Vol. 523, 191-200
Audio-visual interactions in environment assessment
- 1 August 2015
- Published by Elsevier in Science of The Total Environment
- Vol. 523, 191-200
Audio-visual interactions in environment assessment
- Open Access
- 1 September 2013
- Published by Walter de Gruyter GmbH in Archives of Acoustics
- Vol. 38 (3) , 375-381
Pitch Processing of Speech: Comparison of Psychoacoustic and Electrophysiological Data
The present study consisted of two experiments. The goal of the first experiment was to establish the just noticeable differences for the fundamental frequency of the vowel /u/ by using the 2AFC method. We obtained the threshold value for 27 cents. This value is larger than the motor reaction values which had been observed in previous experiments (e.g. 9 or 19 cents). The second experiment was intended to provide neurophysiological confirmation of the detection of shifts in a frequency, using event-related potentials (ERPs). We concentrated on the mismatch negativity (MMN) - the component elicited by the change in the pattern of stimuli. Its occurrence is correlated with the discrimination threshold. In our study, MMN was observed for changes greater than 27 cents - shifts of ±50 and 100 cents (effect size - Cohen’s d = 2.259). MMN did not appear for changes of ±10 and 20 cents. The results showed that the values for which motor responses can be observed are indeed lower than those for perceptual thresholds.
- 1 September 2013
- Published by Walter de Gruyter GmbH in Archives of Acoustics
- Vol. 38 (3) , 375-381
Open AccessPitch Processing of Speech: Comparison of Psychoacoustic and Electrophysiological Data
The present study consisted of two experiments. The goal of the first experiment was to establish the just noticeable differences for the fundamental frequency of the vowel /u/ by using the 2AFC method. We obtained the threshold value for 27 cents. This value is larger than the motor reaction values which had been observed in previous experiments (e.g. 9 or 19 cents). The second experiment was intended to provide neurophysiological confirmation of the detection of shifts in a frequency, using event-related potentials (ERPs). We concentrated on the mismatch negativity (MMN) - the component elicited by the change in the pattern of stimuli. Its occurrence is correlated with the discrimination threshold. In our study, MMN was observed for changes greater than 27 cents - shifts of ±50 and 100 cents (effect size - Cohen’s d = 2.259). MMN did not appear for changes of ±10 and 20 cents. The results showed that the values for which motor responses can be observed are indeed lower than those for perceptual thresholds.