LPLeszek Pstras

Leszek Pstras

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Leszek Pstras has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Estimating heart rate variability using facial video photoplethysmography: a pilot validation study

    by Leszek Pstras, Tymoteusz Okupnik, Beata Ponikowska, Bartlomiej Paleczny

    Video photoplethysmography (vPPG) uses a digital camera to detect pulsations in the blood vessels of the skin, which can be used to estimate various physiological parameters. The aim of this study was to investigate the accuracy and precision of heart rate variability (HRV) indices estimated using a smartphone camera and facial vPPG technology. The study group included 35 healthy volunteers (17 females) with median age 25 years (range 20–42 years). The subjects were in a sitting position, keeping their heads relatively still. A smartphone mounted on a tripod was used to acquire 1-min video recordings of participants’ faces. In parallel, a 1-lead chest electrocardiogram (ECG) was recorded to obtain reference values of two analysed time-domain HRV indices: SDNN and lnRMSSD. For SDNN, the median absolute error was 3.0 ms (7.1% in relative terms), and the root-mean-square error was 4.5 ms (15.7%). For lnRMSSD, the median absolute error was 0.20 (5.6%) and the root-mean-square error was 0.31 (9.9%). Correlations between the vPPG-based and ECG-based HRV values were strong, with the Pearson correlation coefficient of 0.98 for SDNN and 0.88 for lnRMSSD ( P < 0.001 in both cases). In a young, white population, the tested vPPG technology estimated the HRV indices (SDNN and lnRMSSD) with good overall accuracy, with a slight systematic overestimation, especially for low values. The results should be confirmed in a larger study with greater diversity in age and skin tone.

  • Open Access

    Personalized pulse wave propagation modeling to improve vasopressor dosing management in patients with severe traumatic brain injury

    by Kamil Wolos, Leszek Pstras, Urszula Bialonczyk, Malgorzata Debowska, Wojciech Dabrowski, Dorota Siwicka-Gieroba, Jan Poleszczuk

    This study investigates whether examining the shape of arterial pulse waves and fitting to them a physiology-based mathematical model of pulse wave propagation can provide additional insights into the state of the cardiovascular system in patients with severe traumatic brain injury (sTBI), potentially enhancing vasopressor dosing strategies. We conducted a longitudinal study on 25 sTBI patients in an intensive care unit. Arterial pulse waves were recorded non-invasively from wrists and ankles using an oscillometric method and were used to inform a 0-1D model of the arterial blood flow dynamics. Model-estimated, patient-specific cardiovascular parameters were then used in a statistical model to predict changes in the administered dose of vasopressor (norepinephrine) in the next 24 hours. The model fits to the recorded pulse waves were satisfactory, with the coefficients of determination ( R2 ) of approximately 0.9 and the differences between the measured and model-estimated mean arterial pressure of 0.1 ± 1.0 mmHg ( R2 =0.99). Except for a few patients, we found no clear association between the model-estimated parameters and norepinephrine dose at the time of pulse wave recording. Nevertheless, our predictive model achieved a balanced accuracy of 0.85 when trained and tested on the entire dataset and 0.76 when using the leave-one-out cross-validation, with 8 misclassifications among the total of 77 observations. Thus, despite the known inter-patient variability of hemodynamic response to vasopressors, the proposed method allowed predicting the direction of norepinephrine dose changes in the next 24 hours with satisfactory accuracy. Subject to further studies and extensive validation, our approach could inform a decision-support tool for optimizing vasopressor dosing on a per-patient basis.

  • Open Access

    Longitudinal patterns of fluid overload, blood volume and vascular refilling: a prospective study in patients on maintenance hemodialysis

    by Sebastian Mussnig, Simon Krenn, Max Waller, Michael Schmiedecker, Amelie Kurnikowski, Janosch Niknam Saeidi, Luis Naar, Christopher C Mayer, David Keane, Daniel Schneditz, et al.

    Introduction: Patients on maintenance hemodialysis accumulate excess fluid between treatments. Intradialytic removal of fluid via ultrafiltration is partly compensated by vascular refilling from the interstitial space. Associations between whole-body fluid status and blood volume were previously investigated on the population level. The aim of this observational cohort study was to assess longitudinal changes in fluid compartment volumes on an intra-patient level. Methodology: Pre-dialysis bioimpedance spectroscopy measurements and absolute blood volume estimations were conducted in maintenance hemodialysis patients during 14 consecutive dialysis treatments over 5 weeks. Blood volume was determined using the dialysate bolus method. Longitudinal changes were evaluated using linear mixed models. Correlations were analyzed with repeated measures correlation coefficients (${\rho _{rm}}$). Results: Twenty-five patients were included in the final analysis [88% male, median (quartile 1, quartile 3) age and dialysis vintage of 66.0 years (48.0, 74.0) and 23.5 months (13.5, 34.5), respectively]. Pre-dialysis fluid overload significantly decreased from the first to the third treatment within the week (β = −0.38, P < .01) with no significant within-week changes in euvolemic body mass (β= −0.04, P = .78) or absolute blood volume at treatment start (β = −0.06, P = .65). Fluid overload did not correlate with absolute (${\rho _{rm}}$ = 0.10, P = .65) or specific blood volume (${\rho _{rm}}$=0.06, P = .78) at treatment start on an intra-patient level, but correlated moderately with refilling volume (${\rho _{rm}}$ = 0.46, P < .01). Conclusions: The observed lack of intra-patient correlations between pre-dialysis fluid overload and blood volume suggests that excess fluid may not necessarily accumulate proportionally in the interstitial and intravascular space, thus challenging previous assumptions regarding within-week changes in fluid compartments.


  • Open Access

    Leveraging pulse wave signal properties for coronary artery calcification screening in CKD patients

    by Urszula Bialonczyk, Leszek Pstras, Malgorzata Debowska, Lu Dai, Abdul Rashid Qureshi, Magnus Soderberg, Torkel B. Brismar, Jonaz Ripsweden, Bengt Lindholm, Peter Stenvinkel, et al.


  • Open Access

    Facial video photoplethysmography for measuring average and instantaneous heart rate: a pilot validation study

    by Leszek Pstras, Tymoteusz Okupnik, Beata Ponikowska, Bartlomiej Paleczny

    Introduction Video photoplethysmography (vPPG) is a contactless optical technique of recording blood pulsations in the skin vasculature using a digital camera, which is increasingly used to measure or estimate various physiological parameters. Here, we evaluate the accuracy of heart rate (HR) measurements performed using facial vPPG technology Shen.AI Vitals and a smartphone camera. Methods We studied 35 healthy volunteers in a sitting position (median age 25 years, 17 females). Video recordings of participants’ faces were obtained using the front camera of a smartphone mounted on a tripod. In parallel, a 1-lead chest electrocardiogram (ECG) was recorded to obtain reference HR values (average value from the entire 60-second measurement and multiple values averaged over 10-second or 4-second periods during the measurement). Results The mean absolute errors were 0.1, 0.2, and 0.4 beats per minute (bpm) for HR averaged over 60-second, 10-second, and 4-second periods, respectively. The errors did not exceed 1 bpm in 100.0%, 99.8%, and 94.5% of cases, respectively. Regardless of the HR averaging time, the correlation between the vPPG-based and reference values was very strong (r > 0.99, P < 0.001). Conclusions In predominantly young, white, sitting subjects, the tested vPPG technology provided highly accurate HR values, both when averaging over 60 seconds as well as in the case of short-term averages over 10 seconds or instantaneous HR values averaged over 4 seconds. The results should be confirmed in a larger study with greater diversity in age, skin tone, and lighting conditions.

  • Open Access

    Estimating heart rate variability using facial video photoplethysmography: a pilot validation study

    by Leszek Pstras, Tymoteusz Okupnik, Beata Ponikowska, Bartlomiej Paleczny

    Introduction Video photoplethysmography (vPPG) employs a digital camera to detect blood pulsations in the skin vasculature, which can be used to estimate various physiological parameters. In this study, we investigate the accuracy and precision of two heart rate variability (HRV) indices estimated using a smartphone camera and the facial vPPG technology Shen.AI Vitals. Methods The study group included 35 healthy volunteers (17 females) with median age 25 years (range 20–42 years). The subjects were in a sitting position, keeping their heads relatively still. A smartphone mounted on a tripod was used to acquire 1-min video recordings of participants’ faces. In parallel, a 1-lead chest electrocardiogram (ECG) was recorded to obtain reference values of two analysed time-domain HRV indices: SDNN and lnRMSSD. Results For SDNN, the mean absolute error (MAE) was 3.5 ms (11.0% in relative terms) and the root-mean-square error (RMSE) was 4.5 ms (15.7%). For lnRMSSD, the MAE was 0.24 (7.3%) and RMSE was 0.31 (9.9%). Correlations between the vPPG-based and ECG-based HRV values were strong, with the Pearson correlation coefficient of 0.98 for SDNN and 0.88 for lnRMSSD (P < 0.001 in both cases). Conclusions In a young, white population, the tested vPPG technology estimated HRV indices (SDNN and lnRMSSD) with acceptable accuracy in most subjects, with a slight systematic overestimation, especially for low values. The results should be confirmed in a larger study with greater diversity in age and skin tone.

  • A Model-Based Dataset for In-Silico Exploration of the Patterns of Relative Blood Volume Changes During Hemodialysis*

    by Leszek Pstras, Jacek Waniewski

    The patterns of cardiovascular response to hemodialysis (HD), including the relative blood volume (RBV) changes, are not fully understood. Here, we present a synthetic dataset of intradialytic profiles of RBV changes simulated using a lumped-parameter, physiologically-based model of the cardiovascular system and the whole-body water and solute kinetics in 5,000 virtual patients with randomly adjusted values of 90 physiological parameters. The dataset (HD-SIM-RBV) includes a wide range of RBV curves varying in shape and magnitude of RBV changes during HD and it may be used to investigate parameters influencing intradialytic RBV profiles as well as to study the possibility of predicting the end-of-dialysis RBV level using RBV data from the initial phase of HD to help guide HD treatment to avoid hemodynamic instability.Clinical Relevance: Mining this dataset may help elucidate the mechanisms of cardiovascular response to hemodialysis.

  • Open Access

    Estimation of absolute blood volume in hemodialysis patients: A numerical algorithm for assessing blood volume increase after dialysate bolus infusion

    by Leszek Pstras, Simon Krenn, Jacek Waniewski, Michael Schmiedecker, Sebastian Mussnig, Janosch Niknam, Peter Wabel, Christopher C. Mayer, Daniel Schneditz, Manfred Hecking


  • The Impact of Energy Drink Consumption on Heart Rate Variability after Exercise

    by Leszek Pstras

    The effects of caffeine or caffeine-based energy drinks on the recovery of autonomic nervous system balance after exercise have been the subject of several studies that yielded inconclusive results. In a recent study by Porto et al., the impact of a caffeine-based energy drink on heart rate variability (HRV) before and after a moderate aerobic exercise (running on a treadmill) has been studied in a randomized, crossover trial on healthy and active young males. It was concluded that an energy drink consumed before exercise did not affect HRV indices during post-exercise recovery. However, this conclusion is somewhat inconsistent with the reported data and hence may be misleading. Here, I discuss the shortcomings of that study and point out some inaccuracies in the reported results. Considering the above, it appears that energy drink consumption may actually affect some HRV indices after exercise, at least those related to high frequency changes in the autonomic activity.


  • Open Access

    Vascular refilling coefficient is not a good marker of whole-body capillary hydraulic conductivity in hemodialysis patients: insights from a simulation study

    by Leszek Pstras, Jacek Waniewski, Bengt Lindholm

    Refilling of the vascular space through absorption of interstitial fluid by micro vessels is a crucial mechanism for maintaining hemodynamic stability during hemodialysis (HD) and allowing excess fluid to be removed from body tissues. The rate of vascular refilling depends on the imbalance between the Starling forces acting across the capillary walls as well as on their hydraulic conductivity and total surface area. Various approaches have been proposed to assess the vascular refilling process during HD, including the so-called refilling coefficient (Kr) that describes the rate of vascular refilling per changes in plasma oncotic pressure, assuming that other Starling forces and the flow of lymph remain constant during HD. Several studies have shown that Kr decreases exponentially during HD, which was attributed to a dialysis-induced decrease in the whole-body capillary hydraulic conductivity (LpS). Here, we employ a lumped-parameter mathematical model of the cardiovascular system and water and solute transport between the main body fluid compartments to assess the impact of all Starling forces and the flow of lymph on vascular refilling during HD in order to explain the reasons behind the observed intradialytic decrease in Kr. We simulated several HD sessions in a virtual patient with different blood priming procedures, ultrafiltration rates, session durations, and constant or variable levels of LpS. We show that the intradialytic decrease in Kr is not associated with a possible reduction of LpS but results from the inherent assumption that plasma oncotic pressure is the only variable Starling force during HD, whereas in fact other Starling forces, in particular the oncotic pressure of the interstitial fluid, have an important impact on the transcapillary fluid exchange during HD. We conclude that Kr is not a good marker of LpS and should not be used to guide fluid removal during HD or to assess the fluid status of dialysis patients.