Mahmoud Abdelwahab Fathy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahmoud Abdelwahab Fathy has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Saad S. M. Hassan
Department of Chemistry, Faculty of Science, Ain Shams University, Cairo, Egypt
8 shared publications - Ayman Helmi Kamel
Department of Chemistry, College of Science, University of Bahrain
5 shared publications Ayman H. Kamel
Department of Chemistry, Faculty of Science, Ain Shams University, Abbasia, Egypt
3 shared publications- Abd El-Galil E. Amr
Applied Organic Chemistry Department, National Research Center, Dokki, Giza 12622, Egypt
2 shared publications Hadeel H. El-Shalakany
Department of Chemistry, Faculty of Science, Ain Shams University, Abbasia, Egypt
2 shared publications- Mohamed A. Al- Omar
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
2 shared publications
Latest Publications
- Open Access
- 3 March 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (14) , 12713-12724
A novel magnetic AC/bentonite/Fe 3 O 4 /CeO 2 nanocomposite catalyst for photocatalytic degradation of persistent chlorinated pesticides in water
Persistent organic pesticides (POPs), particularly chlorinated pesticides, represent a critical environmental threat due to their chemical stability, bioaccumulation potential, and resistance to conventional water-treatment methods. Herein, a rapid and cost-effective photocatalytic strategy is developed for the degradation of seventeen structurally diverse POPs in water under ultraviolet (UV) irradiation at ambient temperature. A magnetic heterostructured nanocomposite consisting of activated carbon, derived from sugarcane bagasse, and bentonite, coupled with a magnetite/cerium oxide (Fe3O4/CeO2) nanocomposite, is fabricated via a facile ball-milling approach and tested. The material exhibits a strong light absorption, high adsorption capability, high surface activity, and excellent magnetic recoverability. Comprehensive characterization is performed using ultraviolet-visible (UV-vis) spectroscopy, X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and Brunauer–Emmett–Teller (BET) surface analysis. Under optimized conditions (0.1 g L−1 catalyst, 20 °C, UV 365 nm, 20 min), removal efficiencies exceeding 90% are achieved for δ-benzene hexachloride (δ-BHC), heptachlor, dichlorodiphenyl trichloroethane (DDT), endrine aldehyde, and methoxychlor, while 73.9–86.6% degradation is recorded for α-BHC, β-BHC, γ-BHC, aldrin, heptachlor epoxide, dichlorodiphenyldichloroethylene (DDE), endrin, dieldrin, dichlorodiphenyldichloroethane (DDD), and endosulfan sulfate. The developed AC/Bentonite/Fe3O4/CeO2 nanocomposite demonstrates some key advantages including high adsorption affinity, fast reaction kinetics, broad pollutant applicability, magnetic separability, and significantly shorter treatment time compared with many of those previously reported using cerium-based photocatalysts. These results highlight the potential of this sustainable catalyst system for efficient remediation of POP-contaminated water.
- 3 March 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (14) , 12713-12724
Open AccessA novel magnetic AC/bentonite/Fe 3 O 4 /CeO 2 nanocomposite catalyst for photocatalytic degradation of persistent chlorinated pesticides in water
Persistent organic pesticides (POPs), particularly chlorinated pesticides, represent a critical environmental threat due to their chemical stability, bioaccumulation potential, and resistance to conventional water-treatment methods. Herein, a rapid and cost-effective photocatalytic strategy is developed for the degradation of seventeen structurally diverse POPs in water under ultraviolet (UV) irradiation at ambient temperature. A magnetic heterostructured nanocomposite consisting of activated carbon, derived from sugarcane bagasse, and bentonite, coupled with a magnetite/cerium oxide (Fe3O4/CeO2) nanocomposite, is fabricated via a facile ball-milling approach and tested. The material exhibits a strong light absorption, high adsorption capability, high surface activity, and excellent magnetic recoverability. Comprehensive characterization is performed using ultraviolet-visible (UV-vis) spectroscopy, X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and Brunauer–Emmett–Teller (BET) surface analysis. Under optimized conditions (0.1 g L−1 catalyst, 20 °C, UV 365 nm, 20 min), removal efficiencies exceeding 90% are achieved for δ-benzene hexachloride (δ-BHC), heptachlor, dichlorodiphenyl trichloroethane (DDT), endrine aldehyde, and methoxychlor, while 73.9–86.6% degradation is recorded for α-BHC, β-BHC, γ-BHC, aldrin, heptachlor epoxide, dichlorodiphenyldichloroethylene (DDE), endrin, dieldrin, dichlorodiphenyldichloroethane (DDD), and endosulfan sulfate. The developed AC/Bentonite/Fe3O4/CeO2 nanocomposite demonstrates some key advantages including high adsorption affinity, fast reaction kinetics, broad pollutant applicability, magnetic separability, and significantly shorter treatment time compared with many of those previously reported using cerium-based photocatalysts. These results highlight the potential of this sustainable catalyst system for efficient remediation of POP-contaminated water.
- Open Access
A Nano-Sized Poly(aniline-co-thiophene) Based Solid-Contact Screen-Printed Electrode for Batch and Continuous Potentiometric Determination of Iodide
Two approaches are described for construction of a screen-printed planar electrode (SPE) for potentiometric determination of iodide ion. The first, involves preparation and application of iron(II) bathophenanthroline tetraiodoplumbate complex ([Fe(bphen)3][PbI4]), as a sensitive and selective electroactive sensing material in a potentiometric electrode for iodide determination. The second is the use of a nano-sized poly(aniline-co-thiophene) (PANI-co-PT) as a solid-contact material in a planar miniaturized configuration. The SPE displays a Nernstian response for iodide ion with a calibration slope of −58.81 ± 0.69 mV/decade (R2 = 0.9998) over a wide concentration range (9.17 × 10−7–6.94 × 10−3 mol/L), low detection limit (6.09 × 10−7 mol/L), rapid response time (5.0 ± 1.0 s) and long-life span (75 ± 3.0 d). The use of PANI-co-PT solid-contact layer significantly improves the ion-to-electron transduction, eliminates the formation of undesired thin water layer between the sensing membrane and the conducting substrate, prevents membrane delamination, enhances potential stability with a significantly reduced potential drift (8.32 ± 0.12 µV/min) and displays high redox capacitance (2.560 ± 0.040 mF). Water contact angle measurements confirm the increased hydrophobicity of the modified membrane electrode (from 44 ± 0.8° to 93 ± 1.4°) and demonstrate the membrane ability to repel moisture and further stabilize the sensor response. The proposed sensor is successfully integrated into a flow injection analysis (FIA) system to enable real-time and continuous iodide monitoring with high precision, high sample throughput and applicability for quality control of pharmaceuticals and environmental monitoring.
Open AccessA Nano-Sized Poly(aniline-co-thiophene) Based Solid-Contact Screen-Printed Electrode for Batch and Continuous Potentiometric Determination of Iodide
Two approaches are described for construction of a screen-printed planar electrode (SPE) for potentiometric determination of iodide ion. The first, involves preparation and application of iron(II) bathophenanthroline tetraiodoplumbate complex ([Fe(bphen)3][PbI4]), as a sensitive and selective electroactive sensing material in a potentiometric electrode for iodide determination. The second is the use of a nano-sized poly(aniline-co-thiophene) (PANI-co-PT) as a solid-contact material in a planar miniaturized configuration. The SPE displays a Nernstian response for iodide ion with a calibration slope of −58.81 ± 0.69 mV/decade (R2 = 0.9998) over a wide concentration range (9.17 × 10−7–6.94 × 10−3 mol/L), low detection limit (6.09 × 10−7 mol/L), rapid response time (5.0 ± 1.0 s) and long-life span (75 ± 3.0 d). The use of PANI-co-PT solid-contact layer significantly improves the ion-to-electron transduction, eliminates the formation of undesired thin water layer between the sensing membrane and the conducting substrate, prevents membrane delamination, enhances potential stability with a significantly reduced potential drift (8.32 ± 0.12 µV/min) and displays high redox capacitance (2.560 ± 0.040 mF). Water contact angle measurements confirm the increased hydrophobicity of the modified membrane electrode (from 44 ± 0.8° to 93 ± 1.4°) and demonstrate the membrane ability to repel moisture and further stabilize the sensor response. The proposed sensor is successfully integrated into a flow injection analysis (FIA) system to enable real-time and continuous iodide monitoring with high precision, high sample throughput and applicability for quality control of pharmaceuticals and environmental monitoring.
- Open Access
Eco-Friendly Removal and IoT-Based Monitoring of CO2 Emissions Released from Gasoline Engines Using a Novel Compact Nomex/Activated Carbon Sandwich Filter
A novel cost-effective, rapid, and eco-friendly method was described for the removal of carbon dioxide (CO2) from the gaseous emissions of gasoline engines. This involved the use of a sandwich filter (~10 cm diameter) made of a nonwoven poly (m-phenylene isophthalamide) (Nomex) fabric loaded with a thin layer of activated carbon. The optimized filter, with an activated carbon mass of 2.89 mg/cm2, a thickness of 4.8 mm, and an air permeability of 0.5 cm3/cm2/s, was tested. A simple homemade sampling device equipped with solid-state electrochemical sensors to monitor the concentration levels of CO2 before and after filtration of the emissions was utilized. The data were transmitted via a General Packet Radio Service (GPRS) link to an Internet of Things (IoT)-based gas monitoring system for remote management, and real-time data visualization. The proposed device achieved a 70 ± 3.4% CO2-removal efficiency within 7 min of operation. Characterization of the filter was conducted using a high-resolution scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX) and Brunauer–Emmett–Teller (BET) analysis. The effects of loaded activated carbon mass, fabric type, filter porosity, gaseous removal time, and adsorption kinetics were also examined. The proposed filter displayed several advantages, including simplicity, compactness, dry design, ease of regeneration, scalability, durability, low cost, and good efficiency. Heat resistance, fire retardancy, mechanical stability, and the ability to remove other gasoline combustion products such as CO, SOx, NOx, VOCs, and particulates were also offered. The filtration system enabled both in situ and on-line CO2 real-time continuous emission monitoring.
Open AccessEco-Friendly Removal and IoT-Based Monitoring of CO2 Emissions Released from Gasoline Engines Using a Novel Compact Nomex/Activated Carbon Sandwich Filter
A novel cost-effective, rapid, and eco-friendly method was described for the removal of carbon dioxide (CO2) from the gaseous emissions of gasoline engines. This involved the use of a sandwich filter (~10 cm diameter) made of a nonwoven poly (m-phenylene isophthalamide) (Nomex) fabric loaded with a thin layer of activated carbon. The optimized filter, with an activated carbon mass of 2.89 mg/cm2, a thickness of 4.8 mm, and an air permeability of 0.5 cm3/cm2/s, was tested. A simple homemade sampling device equipped with solid-state electrochemical sensors to monitor the concentration levels of CO2 before and after filtration of the emissions was utilized. The data were transmitted via a General Packet Radio Service (GPRS) link to an Internet of Things (IoT)-based gas monitoring system for remote management, and real-time data visualization. The proposed device achieved a 70 ± 3.4% CO2-removal efficiency within 7 min of operation. Characterization of the filter was conducted using a high-resolution scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX) and Brunauer–Emmett–Teller (BET) analysis. The effects of loaded activated carbon mass, fabric type, filter porosity, gaseous removal time, and adsorption kinetics were also examined. The proposed filter displayed several advantages, including simplicity, compactness, dry design, ease of regeneration, scalability, durability, low cost, and good efficiency. Heat resistance, fire retardancy, mechanical stability, and the ability to remove other gasoline combustion products such as CO, SOx, NOx, VOCs, and particulates were also offered. The filtration system enabled both in situ and on-line CO2 real-time continuous emission monitoring.
- 28 March 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (4) , 2948-2956
Detection and Explanation of the Hidden Self-Discharge of Single-Walled Carbon-Nanotube Solid Contacts in Ion-Selective Electrodes
Solid contacts made of nonredox-active high-surface-area materials provide ion-selective electrodes comprising an ionophore-doped sensing membrane with a high capacitance. As emphasized in the literature, this minimizes changes in the measured potential that result from the minimal but unavoidable currents of real-life potentiometric measurements. However, as shown here for solid contacts made of single-walled carbon nanotubes (SWCNTs), solid contacts actively charged up over several minutes to voltages as small as ±100 mV do not hold this charge for longer than a few hours. Potential discharge occurs due to Faradaic processes and charge redistribution within the narrow confines of the SWCNT layer. The composition of the sensor membranes and atmospheric conditions have only a small impact on the kinetics of this spontaneous discharge, suggesting that redox reactions involving oxygen and the sensing membrane components do not play critical roles. Because both ion mobilities and the rate of redox reactions are expected to increase with temperature, the significant acceleration of discharge at higher temperature does not clarify whether charge redistribution or redox reactions dominate this discharge. However, contact angle measurements show that SWCNT-modified electrodes without an ion-selective membrane exhibit a substantial decrease in hydrophobicity after prolonged application of a bias potential as small as +100 mV, while application of a negative voltage had only a minor effect. This is consistent with very slow oxidation of the SWCNTs. These findings highlight the importance of optimizing the surface chemistry of high-surface-area solid contacts in view of high long-term stabilities. We propose quick charging of solid contacts to moderate potentials, followed by long-term potential monitoring under zero-current conditions, as a more thorough approach to characterize ISEs with high-surface-area solid contacts, offering insights not available with conventional chronopotentiometry measurements.
- 28 March 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (4) , 2948-2956
Detection and Explanation of the Hidden Self-Discharge of Single-Walled Carbon-Nanotube Solid Contacts in Ion-Selective Electrodes
Solid contacts made of nonredox-active high-surface-area materials provide ion-selective electrodes comprising an ionophore-doped sensing membrane with a high capacitance. As emphasized in the literature, this minimizes changes in the measured potential that result from the minimal but unavoidable currents of real-life potentiometric measurements. However, as shown here for solid contacts made of single-walled carbon nanotubes (SWCNTs), solid contacts actively charged up over several minutes to voltages as small as ±100 mV do not hold this charge for longer than a few hours. Potential discharge occurs due to Faradaic processes and charge redistribution within the narrow confines of the SWCNT layer. The composition of the sensor membranes and atmospheric conditions have only a small impact on the kinetics of this spontaneous discharge, suggesting that redox reactions involving oxygen and the sensing membrane components do not play critical roles. Because both ion mobilities and the rate of redox reactions are expected to increase with temperature, the significant acceleration of discharge at higher temperature does not clarify whether charge redistribution or redox reactions dominate this discharge. However, contact angle measurements show that SWCNT-modified electrodes without an ion-selective membrane exhibit a substantial decrease in hydrophobicity after prolonged application of a bias potential as small as +100 mV, while application of a negative voltage had only a minor effect. This is consistent with very slow oxidation of the SWCNTs. These findings highlight the importance of optimizing the surface chemistry of high-surface-area solid contacts in view of high long-term stabilities. We propose quick charging of solid contacts to moderate potentials, followed by long-term potential monitoring under zero-current conditions, as a more thorough approach to characterize ISEs with high-surface-area solid contacts, offering insights not available with conventional chronopotentiometry measurements.
- Top Cited PapersOpen Access
- 15 January 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 51
Next-Generation Potentiometric Sensors: A Review of Flexible and Wearable Technologies
In recent years, the field of wearable sensors has undergone significant evolution, emerging as a pivotal topic of research due to the capacity of such sensors to gather physiological data during various human activities. Transitioning from basic fitness trackers, these sensors are continuously being improved, with the ultimate objective to make compact, sophisticated, highly integrated, and adaptable multi-functional devices that seamlessly connect to clothing or the body, and continuously monitor bodily signals without impeding the wearer’s comfort or well-being. Potentiometric sensors, leveraging a range of different solid contact materials, have emerged as a preferred choice for wearable chemical or biological sensors. Nanomaterials play a pivotal role, offering unique properties, such as high conductivity and surface-to-volume ratios. This article provides a review of recent advancements in wearable potentiometric sensors utilizing various solid contacts, with a particular emphasis on nanomaterials. These sensors are employed for precise ion concentration determinations, notably sodium, potassium, calcium, magnesium, ammonium, and chloride, in human biological fluids. This review highlights two primary applications, that is, (1) the enhancement of athletic performance by continuous monitoring of ion levels in sweat to gauge the athlete’s health status, and (2) the facilitation of clinical diagnosis and preventive healthcare by monitoring the health status of patients, in particular to detect early signs of dehydration, fatigue, and muscle spasms.
- 15 January 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 51
Top Cited PapersOpen AccessNext-Generation Potentiometric Sensors: A Review of Flexible and Wearable Technologies
In recent years, the field of wearable sensors has undergone significant evolution, emerging as a pivotal topic of research due to the capacity of such sensors to gather physiological data during various human activities. Transitioning from basic fitness trackers, these sensors are continuously being improved, with the ultimate objective to make compact, sophisticated, highly integrated, and adaptable multi-functional devices that seamlessly connect to clothing or the body, and continuously monitor bodily signals without impeding the wearer’s comfort or well-being. Potentiometric sensors, leveraging a range of different solid contact materials, have emerged as a preferred choice for wearable chemical or biological sensors. Nanomaterials play a pivotal role, offering unique properties, such as high conductivity and surface-to-volume ratios. This article provides a review of recent advancements in wearable potentiometric sensors utilizing various solid contacts, with a particular emphasis on nanomaterials. These sensors are employed for precise ion concentration determinations, notably sodium, potassium, calcium, magnesium, ammonium, and chloride, in human biological fluids. This review highlights two primary applications, that is, (1) the enhancement of athletic performance by continuous monitoring of ion levels in sweat to gauge the athlete’s health status, and (2) the facilitation of clinical diagnosis and preventive healthcare by monitoring the health status of patients, in particular to detect early signs of dehydration, fatigue, and muscle spasms.
- 26 November 2024
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 31 (57) , 65648-65660
A magnetic macroporous α-Fe2O3/Mn2O3 nanocomposite as an efficient adsorbent for simple and rapid removal of Pb(II) from wastewater and electronic waste leachate
A magnetic nanocomposite adsorbent, comprised of macroporous iron oxide/manganese oxide (α-Fe2O3/Mn2O3), is prepared, characterized, and used for lead(II) removal from both industrial wastewater and leachate of electronic waste. The synergistic interaction between iron oxide and manganese oxide significantly enhances the adsorption performance. The surface characteristics and structural composition of the nanocomposite are examined using high-resolution transmission microscopy, X-ray spectroscopy, and Brunauer–Emmett–Teller methods. Under optimized conditions, the present method offers a significantly high adsorption capacity (377.5 ± 8.9 mg.g−1), short contact time (10 min), and an excellent removal efficiency (98.0 ± 0.9%) compared with most of the previously suggested methods. The adsorption kinetics of Pb(II) on the nanocomposite surface follows pseudo-second-order kinetics and exhibits a good fit with the Dubinin-Radushkevich (D-R) model. These findings highlight the applicability of the α-Fe2O3/Mn2O3 magnetic nanocomposite as a promising efficient adsorbent for the rapid removal of lead(II) from hazardous wastewater. Moreover, the proposed nanocomposite adsorbent exhibits remarkable stability and can be easily isolated from the test sample solution for subsequent reuse. The efficacy of the developed adsorptive removal procedure is confirmed by achieving a complete lead(II) ion removal from some industrial wastewater discharged from lead battery factories and from the leachate of electronic waste.
- 26 November 2024
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 31 (57) , 65648-65660
A magnetic macroporous α-Fe2O3/Mn2O3 nanocomposite as an efficient adsorbent for simple and rapid removal of Pb(II) from wastewater and electronic waste leachate
A magnetic nanocomposite adsorbent, comprised of macroporous iron oxide/manganese oxide (α-Fe2O3/Mn2O3), is prepared, characterized, and used for lead(II) removal from both industrial wastewater and leachate of electronic waste. The synergistic interaction between iron oxide and manganese oxide significantly enhances the adsorption performance. The surface characteristics and structural composition of the nanocomposite are examined using high-resolution transmission microscopy, X-ray spectroscopy, and Brunauer–Emmett–Teller methods. Under optimized conditions, the present method offers a significantly high adsorption capacity (377.5 ± 8.9 mg.g−1), short contact time (10 min), and an excellent removal efficiency (98.0 ± 0.9%) compared with most of the previously suggested methods. The adsorption kinetics of Pb(II) on the nanocomposite surface follows pseudo-second-order kinetics and exhibits a good fit with the Dubinin-Radushkevich (D-R) model. These findings highlight the applicability of the α-Fe2O3/Mn2O3 magnetic nanocomposite as a promising efficient adsorbent for the rapid removal of lead(II) from hazardous wastewater. Moreover, the proposed nanocomposite adsorbent exhibits remarkable stability and can be easily isolated from the test sample solution for subsequent reuse. The efficacy of the developed adsorptive removal procedure is confirmed by achieving a complete lead(II) ion removal from some industrial wastewater discharged from lead battery factories and from the leachate of electronic waste.
- Open Access
- 15 November 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (12) , 1-12
A novel miniaturized potentiometric electrode based on carbon nanotubes and molecularly imprinted polymer for the determination of lidocaine
A novel miniaturized, solid-contact potentiometric screen-printed electrode was developed for highly sensitive and selective determination of lidocaine anesthetic. The electrode integrated single-walled carbon nanotubes as a solid-contact material and a molecularly imprinted polymer as a recognition sensory material. The performance characteristics of the electrode were evaluated and optimized to display a Nernstian slope of 58.92 ± 0.98 mV/decade over a linear concentration range of 4.53 × 10−7 to 6.18 × 10−3 mol/l within < 6 s. The detection limit was 7.75 × 10−8 mol/l (18.16 ng/ml) of lidocaine. The use of the molecularly imprinted polymer significantly enhanced the selectivity of the electrode, and carbon nanotubes increased the sensitivity, accuracy, and potential stability. The electrode was successfully used for determining lidocaine in pharmaceutical preparations and human urine. The results favorably compared with data obtained by liquid chromatography–tandem mass spectrometry. Graphical abstract
- 15 November 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (12) , 1-12
Open AccessA novel miniaturized potentiometric electrode based on carbon nanotubes and molecularly imprinted polymer for the determination of lidocaine
A novel miniaturized, solid-contact potentiometric screen-printed electrode was developed for highly sensitive and selective determination of lidocaine anesthetic. The electrode integrated single-walled carbon nanotubes as a solid-contact material and a molecularly imprinted polymer as a recognition sensory material. The performance characteristics of the electrode were evaluated and optimized to display a Nernstian slope of 58.92 ± 0.98 mV/decade over a linear concentration range of 4.53 × 10−7 to 6.18 × 10−3 mol/l within < 6 s. The detection limit was 7.75 × 10−8 mol/l (18.16 ng/ml) of lidocaine. The use of the molecularly imprinted polymer significantly enhanced the selectivity of the electrode, and carbon nanotubes increased the sensitivity, accuracy, and potential stability. The electrode was successfully used for determining lidocaine in pharmaceutical preparations and human urine. The results favorably compared with data obtained by liquid chromatography–tandem mass spectrometry. Graphical abstract
- 27 June 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (7) , 1-12
Novel paper-based potentiometric combined sensors using coumarin derivatives modified with vanadium pentoxide nanoparticles for the selective determination of trace levels of lead ions
Novel miniaturized Pb(II) paper-based potentiometric sensors are described using coumarin derivatives I and II as electroactive ionophores and nano vanadium pentoxide as a solid contact material for the sensitive and selective monitoring of trace lead ions. Density functional theory (DFT) confirms optimum geometries, electronic properties, and charge transfer behaviors of 1:2 Pb(II): coumarin complexes. The sensors are prepared by using two strips of 20 × 5 mm filter paper with two circular orifices. One orifice is coated with vanadium pentoxide (V2O5) nanoparticles in colloidal conductive carbon as a solid-contact, covered by a PVC membrane containing coumarin ionophore to act as a sensing probe. The other orifice is treated with Ag/AgCl in a polyvinyl butyral (PVB) film, to act as a reference electrode. Sensors with ionophores (I) and (II) exhibit Nernstian slopes of 27.7 ± 0.2 and 30.2 ± 0.2 mV/decade over the linear concentration range 4.5 × 10−7 to 6.2 × 10−3 M and 8.5 × 10−8 to 6.2 × 10−3 M, with detection limits of 1.3 × 10−7 M (26.9 ppb) and 2.1 × 10−8 M (4.4 ppb), respectively. The sensors are satisfactorily used for accurate determination of lead ions in drinking water, lead-acid battery wastewater, and electronic waste leachates. The results compare favourably well with data obtained by flameless atomic absorption spectrometry. Graphical abstract
- 27 June 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (7) , 1-12
Novel paper-based potentiometric combined sensors using coumarin derivatives modified with vanadium pentoxide nanoparticles for the selective determination of trace levels of lead ions
Novel miniaturized Pb(II) paper-based potentiometric sensors are described using coumarin derivatives I and II as electroactive ionophores and nano vanadium pentoxide as a solid contact material for the sensitive and selective monitoring of trace lead ions. Density functional theory (DFT) confirms optimum geometries, electronic properties, and charge transfer behaviors of 1:2 Pb(II): coumarin complexes. The sensors are prepared by using two strips of 20 × 5 mm filter paper with two circular orifices. One orifice is coated with vanadium pentoxide (V2O5) nanoparticles in colloidal conductive carbon as a solid-contact, covered by a PVC membrane containing coumarin ionophore to act as a sensing probe. The other orifice is treated with Ag/AgCl in a polyvinyl butyral (PVB) film, to act as a reference electrode. Sensors with ionophores (I) and (II) exhibit Nernstian slopes of 27.7 ± 0.2 and 30.2 ± 0.2 mV/decade over the linear concentration range 4.5 × 10−7 to 6.2 × 10−3 M and 8.5 × 10−8 to 6.2 × 10−3 M, with detection limits of 1.3 × 10−7 M (26.9 ppb) and 2.1 × 10−8 M (4.4 ppb), respectively. The sensors are satisfactorily used for accurate determination of lead ions in drinking water, lead-acid battery wastewater, and electronic waste leachates. The results compare favourably well with data obtained by flameless atomic absorption spectrometry. Graphical abstract
- 8 May 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (6) , 1-11
A novel potentiometric screen-printed electrode based on crown ethers/nano manganese oxide/Nafion composite for trace level determination of copper ion in biological fluids
Copper levels in biological fluids are associated with Wilson's, Alzheimer's, Menke's, and Parkinson's diseases, making them good biochemical markers for these diseases. This study introduces a miniaturized screen-printed electrode (SPE) for the potentiometric determination of copper(II) in some biological fluids. Manganese(III) oxide nanoparticles (Mn2O3-NPs), dispersed in Nafion, are drop-casted onto a graphite/PET substrate, serving as the ion-to-electron transducer material. The solid-contact material is then covered by a selective polyvinyl chloride (PVC) membrane incorporated with 18-crown-6 as a neutral ion carrier for the selective determination of copper(II) ions. The proposed electrode exhibits a Nernstian response with a slope of 30.2 ± 0.3 mV/decade (R2 = 0.999) over the linear concentration range 5.2 × 10–9 – 6.2 × 10–3 mol/l and a detection limit of 1.1 × 10–9 mol/l (69.9 ng/l). Short-term potential stability is evaluated using constant current chronopotentiometry (CP) and electrochemical impedance spectroscopy (EIS). A significant improvement in the electrode capacitance (91.5 μF) is displayed due to the use of Mn2O3-NPs as a solid contact. The presence of Nafion, with its high hydrophobicity properties, eliminates the formation of the thin water layer, facilitating the ion-to-electron transduction between the sensing membrane and the conducting substrate. Additionally, it enhances the adhesion of the polymeric sensing membrane to the solid-contact material, preventing membrane delamination and increasing the electrode's lifespan. The high selectivity, sensitivity, and potential stability of the proposed miniaturized electrode suggests its use for the determination of copper(II) ions in human blood serum and milk samples. The results obtained agree fairly well with data obtained by flameless atomic absorption spectrometry. Graphical Abstract
- 8 May 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (6) , 1-11
A novel potentiometric screen-printed electrode based on crown ethers/nano manganese oxide/Nafion composite for trace level determination of copper ion in biological fluids
Copper levels in biological fluids are associated with Wilson's, Alzheimer's, Menke's, and Parkinson's diseases, making them good biochemical markers for these diseases. This study introduces a miniaturized screen-printed electrode (SPE) for the potentiometric determination of copper(II) in some biological fluids. Manganese(III) oxide nanoparticles (Mn2O3-NPs), dispersed in Nafion, are drop-casted onto a graphite/PET substrate, serving as the ion-to-electron transducer material. The solid-contact material is then covered by a selective polyvinyl chloride (PVC) membrane incorporated with 18-crown-6 as a neutral ion carrier for the selective determination of copper(II) ions. The proposed electrode exhibits a Nernstian response with a slope of 30.2 ± 0.3 mV/decade (R2 = 0.999) over the linear concentration range 5.2 × 10–9 – 6.2 × 10–3 mol/l and a detection limit of 1.1 × 10–9 mol/l (69.9 ng/l). Short-term potential stability is evaluated using constant current chronopotentiometry (CP) and electrochemical impedance spectroscopy (EIS). A significant improvement in the electrode capacitance (91.5 μF) is displayed due to the use of Mn2O3-NPs as a solid contact. The presence of Nafion, with its high hydrophobicity properties, eliminates the formation of the thin water layer, facilitating the ion-to-electron transduction between the sensing membrane and the conducting substrate. Additionally, it enhances the adhesion of the polymeric sensing membrane to the solid-contact material, preventing membrane delamination and increasing the electrode's lifespan. The high selectivity, sensitivity, and potential stability of the proposed miniaturized electrode suggests its use for the determination of copper(II) ions in human blood serum and milk samples. The results obtained agree fairly well with data obtained by flameless atomic absorption spectrometry. Graphical Abstract