Juan Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juan Wei has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bo Xiao
Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Luwei Yang
Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Weizhao Li
Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Wenye Lin
Tencent AI Lab
1 shared publication - Xiang Mao
Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Ya Yuan
Technical Institute of Physics and Chemistry (TIPC), Chinese Academy of Sciences (CAS)
1 shared publication
Latest Publications
- Open Access
Performance Analysis of Heat Pump Dryer with Unit-Room in Cold Climate Regions
This study presents the development and evaluation of a novel partially open-loop heat pump dryer with a unit-room (HPDU). The unit-room was designed to enable the ambient air to be mixed with the return air, thereby reducing the influence of the ambient air on the system performance, while maintaining a high system thermal efficiency. A modelling system for the HPDU was developed and validated based on a real-scale experimental study. By using the modelling system, the system characteristics under different ambient conditions and bypass factors were analyzed. The energy benefit of the proposed HPDU was quantified through a comparative study with a closed-loop heat pump dryer (CHPD). It is evident that a maximal specific moisture extraction rate (SMER) and a minimal total energy consumption (TEC) existed when changing the bypass factor of the HPDU under certain ambient temperatures. Compared to the CHPD, the coefficient of performance (COP) of the HPDU increased by up to 39.56%, presenting a significant energy benefit for the application of HPDU.
Open AccessPerformance Analysis of Heat Pump Dryer with Unit-Room in Cold Climate Regions
This study presents the development and evaluation of a novel partially open-loop heat pump dryer with a unit-room (HPDU). The unit-room was designed to enable the ambient air to be mixed with the return air, thereby reducing the influence of the ambient air on the system performance, while maintaining a high system thermal efficiency. A modelling system for the HPDU was developed and validated based on a real-scale experimental study. By using the modelling system, the system characteristics under different ambient conditions and bypass factors were analyzed. The energy benefit of the proposed HPDU was quantified through a comparative study with a closed-loop heat pump dryer (CHPD). It is evident that a maximal specific moisture extraction rate (SMER) and a minimal total energy consumption (TEC) existed when changing the bypass factor of the HPDU under certain ambient temperatures. Compared to the CHPD, the coefficient of performance (COP) of the HPDU increased by up to 39.56%, presenting a significant energy benefit for the application of HPDU.