Gianpaolo Serino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gianpaolo Serino has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
- Cristina Bignardi
Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, 10129 Torino, Italy
8 shared publications - Alberto Luigi Audenino
Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129 Turin, Italy
6 shared publications - Mara Terzini
Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, 10129 Torino, Italy
5 shared publications Alberto Audenino
Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy; Polito BIO Med Lab, Politecnico di Torino, Turin, Italy
3 shared publications- Andrea Tancredi Lugas
PolitoBIOMed Lab, Polytechnic University of Turin, 10129 Torino, Italy
3 shared publications Diana Massai
PolitoBIOMed Lab, Dept. of Mechanical and Aerospace Engineering, Politecnico di Torino, Torino; Interuniversity Center for the Promotion of the 3Rs Principles in Teaching and Research
3 shared publications
Latest Publications
- Open Access
Modeling spheroid assembly dynamics and mechanical stress generation in magnetic-based biofabrication
Magnetic biofabrication enables rapid assembly of multicellular spheroids but still lacks a basis for predictive control over structure and mechanical environment. Here, we combine experiments and an individual spheroid-based model to study magnetic assembly of periosteum-derived spheroids. Spheroids are treated as discrete particles interacting through magnetic forces, contact mechanics, and interfacial friction, with parameters obtained from independent measurements. This model quantitatively captures assembly dynamics arising from magnetic force patterns and viscous drag with the well surface. The spatial distribution of magnetic forces, determined by magnet geometry and positioning, predicts the size and morphology of magnetic assembloids, including disk- and ring-like structures. Magnetic assembly further generates heterogeneous compressive stresses that depend on magnet geometry and spheroid number. Radial stresses arise collectively through inter-spheroid interactions, whereas vertical stresses are mainly determined by magnetic loading of individual spheroids. These results establish a minimal physical framework for magnetic biofabrication and provide a basis for predictive control of both tissue structure and mechanical microenvironment.
Open AccessModeling spheroid assembly dynamics and mechanical stress generation in magnetic-based biofabrication
Magnetic biofabrication enables rapid assembly of multicellular spheroids but still lacks a basis for predictive control over structure and mechanical environment. Here, we combine experiments and an individual spheroid-based model to study magnetic assembly of periosteum-derived spheroids. Spheroids are treated as discrete particles interacting through magnetic forces, contact mechanics, and interfacial friction, with parameters obtained from independent measurements. This model quantitatively captures assembly dynamics arising from magnetic force patterns and viscous drag with the well surface. The spatial distribution of magnetic forces, determined by magnet geometry and positioning, predicts the size and morphology of magnetic assembloids, including disk- and ring-like structures. Magnetic assembly further generates heterogeneous compressive stresses that depend on magnet geometry and spheroid number. Radial stresses arise collectively through inter-spheroid interactions, whereas vertical stresses are mainly determined by magnetic loading of individual spheroids. These results establish a minimal physical framework for magnetic biofabrication and provide a basis for predictive control of both tissue structure and mechanical microenvironment.
- Open Access
- 19 May 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (5) , 251
Geometric Accuracy of 3D-Printed Composite Dental Restorations Compared with the Original STL Design
Additive manufacturing (AM) enables customized, efficient restorative workflows, though the accuracy of 3D-printed restorations may be compromised by polymerization, sintering shrinkage, and post-processing. This study evaluated the geometric accuracy of 3D-printed partial restorations compared with the computer-aided design (CAD) reference. The null hypothesis stated that no significant differences would be found between Varseo Smile Crownplus (by BEGO, Italy) and IRIXMax (by DWS System, Italy) materials, which are printed and cured with different technologies. A model was prepared for an overlay and designed with a 1.5 mm uniform thickness. Restorations were produced in two groups with two different printing processes: DLP (digital light processing)-printed Varseo Smile Crownplus and SLA (stereolithography)-printed IRIXMax. Six samples per group were printed at 90° orientation and scanned. Meshes were aligned to the master geometry via pre-alignment and ICP (Iterative Closest Point) registration. Deviations were quantified in CloudCompare using mean, standard deviation (SD), and 90th percentile values. IRIXMax showed the lowest deviations from the ideal geometry, while Varseo Smile Crownplus exhibited greater variability. Pairwise comparisons found IRIXMax significantly more accurate than Varseo Smile Crownplus. Color maps confirmed material-specific deviation patterns. IRIXMax provided the highest geometric accuracy. Material-specific calibration is essential for reliable 3D-printed definitive restorations.
- 19 May 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (5) , 251
Open AccessGeometric Accuracy of 3D-Printed Composite Dental Restorations Compared with the Original STL Design
Additive manufacturing (AM) enables customized, efficient restorative workflows, though the accuracy of 3D-printed restorations may be compromised by polymerization, sintering shrinkage, and post-processing. This study evaluated the geometric accuracy of 3D-printed partial restorations compared with the computer-aided design (CAD) reference. The null hypothesis stated that no significant differences would be found between Varseo Smile Crownplus (by BEGO, Italy) and IRIXMax (by DWS System, Italy) materials, which are printed and cured with different technologies. A model was prepared for an overlay and designed with a 1.5 mm uniform thickness. Restorations were produced in two groups with two different printing processes: DLP (digital light processing)-printed Varseo Smile Crownplus and SLA (stereolithography)-printed IRIXMax. Six samples per group were printed at 90° orientation and scanned. Meshes were aligned to the master geometry via pre-alignment and ICP (Iterative Closest Point) registration. Deviations were quantified in CloudCompare using mean, standard deviation (SD), and 90th percentile values. IRIXMax showed the lowest deviations from the ideal geometry, while Varseo Smile Crownplus exhibited greater variability. Pairwise comparisons found IRIXMax significantly more accurate than Varseo Smile Crownplus. Color maps confirmed material-specific deviation patterns. IRIXMax provided the highest geometric accuracy. Material-specific calibration is essential for reliable 3D-printed definitive restorations.
- Open Access
- 1 March 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (5) , 2873
Early Impairment of Paracrine and Phenotypic Features in Resident Cardiac Mesenchymal Stromal Cells after Thoracic Radiotherapy
Radiotherapy-induced cardiac toxicity and consequent diseases still represent potential severe late complications for many cancer survivors who undergo therapeutic thoracic irradiation. We aimed to assess the phenotypic and paracrine features of resident cardiac mesenchymal stromal cells (CMSCs) at early follow-up after the end of thoracic irradiation of the heart as an early sign and/or mechanism of cardiac toxicity anticipating late organ dysfunction. Resident CMSCs were isolated from a rat model of fractionated thoracic irradiation with accurate and clinically relevant heart dosimetry that developed delayed dose-dependent cardiac dysfunction after 1 year. Cells were isolated 6 and 12 weeks after the end of radiotherapy and fully characterized at the transcriptional, paracrine, and functional levels. CMSCs displayed several altered features in a dose- and time-dependent trend, with the most impaired characteristics observed in those exposed in situ to the highest radiation dose with time. In particular, altered features included impaired cell migration and 3D growth and a and significant association of transcriptomic data with GO terms related to altered cytokine and growth factor signaling. Indeed, the altered paracrine profile of CMSCs derived from the group at the highest dose at the 12-week follow-up gave significantly reduced angiogenic support to endothelial cells and polarized macrophages toward a pro-inflammatory profile. Data collected in a clinically relevant rat model of heart irradiation simulating thoracic radiotherapy suggest that early paracrine and transcriptional alterations of the cardiac stroma may represent a dose- and time-dependent biological substrate for the delayed cardiac dysfunction phenotype observed in vivo.
- 1 March 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (5) , 2873
Open AccessEarly Impairment of Paracrine and Phenotypic Features in Resident Cardiac Mesenchymal Stromal Cells after Thoracic Radiotherapy
Radiotherapy-induced cardiac toxicity and consequent diseases still represent potential severe late complications for many cancer survivors who undergo therapeutic thoracic irradiation. We aimed to assess the phenotypic and paracrine features of resident cardiac mesenchymal stromal cells (CMSCs) at early follow-up after the end of thoracic irradiation of the heart as an early sign and/or mechanism of cardiac toxicity anticipating late organ dysfunction. Resident CMSCs were isolated from a rat model of fractionated thoracic irradiation with accurate and clinically relevant heart dosimetry that developed delayed dose-dependent cardiac dysfunction after 1 year. Cells were isolated 6 and 12 weeks after the end of radiotherapy and fully characterized at the transcriptional, paracrine, and functional levels. CMSCs displayed several altered features in a dose- and time-dependent trend, with the most impaired characteristics observed in those exposed in situ to the highest radiation dose with time. In particular, altered features included impaired cell migration and 3D growth and a and significant association of transcriptomic data with GO terms related to altered cytokine and growth factor signaling. Indeed, the altered paracrine profile of CMSCs derived from the group at the highest dose at the 12-week follow-up gave significantly reduced angiogenic support to endothelial cells and polarized macrophages toward a pro-inflammatory profile. Data collected in a clinically relevant rat model of heart irradiation simulating thoracic radiotherapy suggest that early paracrine and transcriptional alterations of the cardiac stroma may represent a dose- and time-dependent biological substrate for the delayed cardiac dysfunction phenotype observed in vivo.
- Open Access
- 29 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (3) , 244
Multiscale Mechanical Characterization of Polyether-2-ketone (PEKK) for Biomedical Application
Polyether-ether-2-ketone (PEKK) is a high-performance thermoplastic polymer used in various fields, from aerospace to medical applications, due to its exceptional mechanical and thermal properties. Nonetheless, the mechanical behavior of 3D-printed PEKK still deserves to be more thoroughly investigated, especially in view of its production by 3D printing, where mechanical properties measured at different scales are likely to be correlated to one another and to all play a major role in determining biomechanical properties, which include mechanical strength on one side and osteointegration ability on the other side. This work explores the mechanical behavior of 3D-printed PEKK through a multiscale approach, having performed both nanoindentation tests and standard tensile and compression tests, where a detailed view of strain distribution was achieved through Digital Image Correlation (DIC) techniques. Furthermore, for specimens tested up to failure, their fractured surfaces were analyzed through Scanning Electron Microscopy (SEM) to clearly outline fracture modes. Additionally, the internal structure of 3D-printed PEKK was explored through Computed Tomography (CT) imaging, providing a three-dimensional view of the internal structure and the presence of voids and other imperfections. Finally, surface morphology was analyzed through confocal microscopy. The multiscale approach adopted in the present work offers information about the global and local behavior of the PEKK, also assessing its material properties down to the nanoscale. Due to its novelty as a polymeric material, no previous studies have approached a multiscale analysis of 3D-printed PEKK. The findings of this study contribute to a comprehensive understanding of 3D-printed PEKK along with criteria for process optimization in order to customize its properties to meet specific application requirements. This research not only advances the knowledge of PEKK as a 3D-printing material but also provides insights into the multifaceted nature of multiscale material characterization.
- 29 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (3) , 244
Open AccessMultiscale Mechanical Characterization of Polyether-2-ketone (PEKK) for Biomedical Application
Polyether-ether-2-ketone (PEKK) is a high-performance thermoplastic polymer used in various fields, from aerospace to medical applications, due to its exceptional mechanical and thermal properties. Nonetheless, the mechanical behavior of 3D-printed PEKK still deserves to be more thoroughly investigated, especially in view of its production by 3D printing, where mechanical properties measured at different scales are likely to be correlated to one another and to all play a major role in determining biomechanical properties, which include mechanical strength on one side and osteointegration ability on the other side. This work explores the mechanical behavior of 3D-printed PEKK through a multiscale approach, having performed both nanoindentation tests and standard tensile and compression tests, where a detailed view of strain distribution was achieved through Digital Image Correlation (DIC) techniques. Furthermore, for specimens tested up to failure, their fractured surfaces were analyzed through Scanning Electron Microscopy (SEM) to clearly outline fracture modes. Additionally, the internal structure of 3D-printed PEKK was explored through Computed Tomography (CT) imaging, providing a three-dimensional view of the internal structure and the presence of voids and other imperfections. Finally, surface morphology was analyzed through confocal microscopy. The multiscale approach adopted in the present work offers information about the global and local behavior of the PEKK, also assessing its material properties down to the nanoscale. Due to its novelty as a polymeric material, no previous studies have approached a multiscale analysis of 3D-printed PEKK. The findings of this study contribute to a comprehensive understanding of 3D-printed PEKK along with criteria for process optimization in order to customize its properties to meet specific application requirements. This research not only advances the knowledge of PEKK as a 3D-printing material but also provides insights into the multifaceted nature of multiscale material characterization.
- Open Access
- 21 February 2024
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 25 (2) , 685-695
Development and validation of cryopreserved or freeze-dried decellularized human dermis for transplantation
For decades, dermal tissue grafts have been used in various regenerative, reconstructive, and augmentative procedures across the body. To eliminate antigenicity and immunogenic response while still preserving the individual components and collective structural integrity of the extracellular matrix (ECM), dermis can be decellularized. Acellular dermal matrix (ADM) products like such are produced to accurately serve diverse clinical purposes. The aim of the present study is to evaluate the efficacy of a novel decellularization protocol of the human dermis, which eliminates residual human genetic material without compromising the biomechanical integrity and collagenous content of the tissue. Moreover, a freeze-drying protocol was validated. The results showed that though our decellularization protocol, human dermis can be decellularized obtaining a biocompatible matrix. The procedure is completely realized in GMP aseptic condition, avoiding tissue terminal sterilization.
- 21 February 2024
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 25 (2) , 685-695
Open AccessDevelopment and validation of cryopreserved or freeze-dried decellularized human dermis for transplantation
For decades, dermal tissue grafts have been used in various regenerative, reconstructive, and augmentative procedures across the body. To eliminate antigenicity and immunogenic response while still preserving the individual components and collective structural integrity of the extracellular matrix (ECM), dermis can be decellularized. Acellular dermal matrix (ADM) products like such are produced to accurately serve diverse clinical purposes. The aim of the present study is to evaluate the efficacy of a novel decellularization protocol of the human dermis, which eliminates residual human genetic material without compromising the biomechanical integrity and collagenous content of the tissue. Moreover, a freeze-drying protocol was validated. The results showed that though our decellularization protocol, human dermis can be decellularized obtaining a biocompatible matrix. The procedure is completely realized in GMP aseptic condition, avoiding tissue terminal sterilization.
- Open Access
- 29 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (3) , 776
Short-Term Effects of 3D-Printed Occlusal Splints and Conventional Splints on Sleep Bruxism Activity: EMG–ECG Night Recordings of a Sample of Young Adults
(1) Background: This study aims to compare the effects of 3D-printed splints and conventional manufactured splints on sleep bruxism (SB) EMG activity. (2) Methods: Twenty-six patients (19 M, 7 F, 25.8 ± 2.6 years) were randomly allocated to a study group (3D splints) and a control group (conventional manufactured splints) and followed for a period of three months with night EMG–ECG recordings. Samples of the involved materials were analyzed for nanoindentation. The outcomes of interest considered were the overall SB index, the total amount of surface masseter muscle activity (sMMA), and general and SB-related phasic and tonic contractions. A statistical evaluation was performed with a confidence interval (CI) between 2.5% and 97.5%. (3) Results: Differences between groups with OAs were observed for general tonic contraction (p = 0.0009), while differences between recording times were observed for general phasic contractions (p = 0.002) and general tonic contractions (p = 0.00001). Differences between recording times were observed for the total amount of sMMA (p = 0.01), for general phasic contractions (p = 0.0001), and for general tonic contractions (p = 0.000009) during night recordings without OAs. (4) Conclusions: Three-dimensional splints seem to have a higher impact on SB-related electromyographic activity but not on the overall sleep bruxism index. The more regular surfaces offered by 3D splints could be related to phasic contraction stabilization.
- 29 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (3) , 776
Open AccessShort-Term Effects of 3D-Printed Occlusal Splints and Conventional Splints on Sleep Bruxism Activity: EMG–ECG Night Recordings of a Sample of Young Adults
(1) Background: This study aims to compare the effects of 3D-printed splints and conventional manufactured splints on sleep bruxism (SB) EMG activity. (2) Methods: Twenty-six patients (19 M, 7 F, 25.8 ± 2.6 years) were randomly allocated to a study group (3D splints) and a control group (conventional manufactured splints) and followed for a period of three months with night EMG–ECG recordings. Samples of the involved materials were analyzed for nanoindentation. The outcomes of interest considered were the overall SB index, the total amount of surface masseter muscle activity (sMMA), and general and SB-related phasic and tonic contractions. A statistical evaluation was performed with a confidence interval (CI) between 2.5% and 97.5%. (3) Results: Differences between groups with OAs were observed for general tonic contraction (p = 0.0009), while differences between recording times were observed for general phasic contractions (p = 0.002) and general tonic contractions (p = 0.00001). Differences between recording times were observed for the total amount of sMMA (p = 0.01), for general phasic contractions (p = 0.0001), and for general tonic contractions (p = 0.000009) during night recordings without OAs. (4) Conclusions: Three-dimensional splints seem to have a higher impact on SB-related electromyographic activity but not on the overall sleep bruxism index. The more regular surfaces offered by 3D splints could be related to phasic contraction stabilization.
- Open Access
- 27 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (3) , 1093
A Methodological Approach for Interpreting and Comparing the Viscoelastic Behaviors of Soft Biological Tissues and Hydrogels at the Cell-Length Scale
The behavior of a cell is strongly influenced by the physical properties and stimuli in its microenvironment. Furthermore, the activation and modulation of mechanotransduction pathways are involved in tissue development and homeostasis and even pathological processes. Thus, when developing materials aimed at mimicking the extracellular matrixes of healthy or pathological tissues, their mechanical features should be closely considered. In this context, nanoindentation represents a powerful technique for mechanically characterizing biological tissues and hydrogels at the cell-length scale. However, standardized experimental protocols and data analysis techniques are lacking. Here, we proposed a methodological approach based on the nanoindentation technique for quantitatively analyzing and comparing the time-dependent load relaxation responses of soft biological tissues and hydrogels. As this was an explanatory study, stress-relaxation nanoindentation tests were performed on samples of pig and human lung tissues and of a specific gelatin-methacryloyl (GelMA) hydrogel to quantify and compare their viscoelastic properties. The proposed method allowed for identifying the characteristic parameters needed for describing the behavior of each sample, permitting us to quantitatively compare their mechanical behaviors. All samples showed load relaxation at a defined indentation depth because of their intrinsic viscoelastic behaviors, and the GelMA samples showed the highest relaxation capabilities. The distribution of the characterization parameters showed that the biological samples presented similar time-dependent responses, while differences were observed in the GelMA samples. Overall, the proposed methodological approach allows for providing key insights into the time-dependent behaviors of soft biological tissues and hydrogels at the cell-length scale in view of supporting tissue engineering and pathophysiological investigations.
- 27 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (3) , 1093
Open AccessA Methodological Approach for Interpreting and Comparing the Viscoelastic Behaviors of Soft Biological Tissues and Hydrogels at the Cell-Length Scale
The behavior of a cell is strongly influenced by the physical properties and stimuli in its microenvironment. Furthermore, the activation and modulation of mechanotransduction pathways are involved in tissue development and homeostasis and even pathological processes. Thus, when developing materials aimed at mimicking the extracellular matrixes of healthy or pathological tissues, their mechanical features should be closely considered. In this context, nanoindentation represents a powerful technique for mechanically characterizing biological tissues and hydrogels at the cell-length scale. However, standardized experimental protocols and data analysis techniques are lacking. Here, we proposed a methodological approach based on the nanoindentation technique for quantitatively analyzing and comparing the time-dependent load relaxation responses of soft biological tissues and hydrogels. As this was an explanatory study, stress-relaxation nanoindentation tests were performed on samples of pig and human lung tissues and of a specific gelatin-methacryloyl (GelMA) hydrogel to quantify and compare their viscoelastic properties. The proposed method allowed for identifying the characteristic parameters needed for describing the behavior of each sample, permitting us to quantitatively compare their mechanical behaviors. All samples showed load relaxation at a defined indentation depth because of their intrinsic viscoelastic behaviors, and the GelMA samples showed the highest relaxation capabilities. The distribution of the characterization parameters showed that the biological samples presented similar time-dependent responses, while differences were observed in the GelMA samples. Overall, the proposed methodological approach allows for providing key insights into the time-dependent behaviors of soft biological tissues and hydrogels at the cell-length scale in view of supporting tissue engineering and pathophysiological investigations.
- Open Access
- 25 January 2023
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 25 (2) , 401-410
Decellularized cryopreserved human pericardium: a validation study towards tissue bank practice
Pericardial patches are currently used as reconstructive material in cardiac surgery for surgical treatment of cardiac septal defects. Autologous pericardial patches, either treated with glutaraldehyde or not, can be used as an alternative to synthetic materials or xenograft in congenital septal defects repair. The availability of an allogenic decellularized pericardium could reduce complication during and after surgery and could be a valid alternative. Decellularization of allogenic tissues aims at reducing the immunogenic reaction that might trigger inflammation and tissue calcification over time. The ideal graft for congenital heart disease repair should be biocompatible, mechanically resistant, non-immunogenic, and should have the ability to growth with the patients. The aim of the present study is the evaluation of the efficacy of a new decellularization protocol of homologous pericardium, even after cryopreservation. The technique has proven to be suitable as a tissue bank procedure and highly successful in the removal of cells and nucleic acids content, but also in the preservation of collagen and biomechanical properties of the human pericardium.
- 25 January 2023
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 25 (2) , 401-410
Open AccessDecellularized cryopreserved human pericardium: a validation study towards tissue bank practice
Pericardial patches are currently used as reconstructive material in cardiac surgery for surgical treatment of cardiac septal defects. Autologous pericardial patches, either treated with glutaraldehyde or not, can be used as an alternative to synthetic materials or xenograft in congenital septal defects repair. The availability of an allogenic decellularized pericardium could reduce complication during and after surgery and could be a valid alternative. Decellularization of allogenic tissues aims at reducing the immunogenic reaction that might trigger inflammation and tissue calcification over time. The ideal graft for congenital heart disease repair should be biocompatible, mechanically resistant, non-immunogenic, and should have the ability to growth with the patients. The aim of the present study is the evaluation of the efficacy of a new decellularization protocol of homologous pericardium, even after cryopreservation. The technique has proven to be suitable as a tissue bank procedure and highly successful in the removal of cells and nucleic acids content, but also in the preservation of collagen and biomechanical properties of the human pericardium.
- Open Access
- 29 September 2021
- Published by PAGEPress Publications in Biomedical Science and Engineering
- Vol. 2 (1)
PDMS Substrates with tunable stiffness for cardiac mechanobiology investigation: A nanoindentation study
Micromechanical characterization by nanoindentation of PDMS substrates for cardiac mechanobiology studies.
- 29 September 2021
- Published by PAGEPress Publications in Biomedical Science and Engineering
- Vol. 2 (1)
Open AccessPDMS Substrates with tunable stiffness for cardiac mechanobiology investigation: A nanoindentation study
Micromechanical characterization by nanoindentation of PDMS substrates for cardiac mechanobiology studies.