Shuya Lei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuya Lei has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Guozeng Feng
Jiangsu University of Science and Technology
2 shared publications - Bo Meng
School of Energy and Power, Jiangsu University of Science and Technology, Zhenjiang 212003, China
1 shared publication - Junyi Wang
School of Teacher Education Nanjing University of Information Science & Technology Nanjing China
1 shared publication - Qingfeng Jiang
School of Energy and Power, Jiangsu University of Science and Technology, Zhenjiang 212003, China
1 shared publication - Xiaomeng Gu
IntSig Information Co., Ltd., Shanghai, China
1 shared publication - Yuejiao Guo
School of Energy and Power, Jiangsu University of Science and Technology, Zhenjiang 212003, China
1 shared publication
Latest Publications
- 1 January 2021
- Published by Elsevier in Building and Environment
- Vol. 188, 107485
Predictive control model for variable air volume terminal valve opening based on backpropagation neural network
- 1 January 2021
- Published by Elsevier in Building and Environment
- Vol. 188, 107485
Predictive control model for variable air volume terminal valve opening based on backpropagation neural network
- Open Access
Optimization and Evaluation of Ventilation Mode in Marine Data Center Based on AHP-Entropy Weight
The ventilation mode affects the cooling efficiency of the air conditioners significantly in marine data centers. Three different ventilation modes, namely, underfloor ventilation, overhead ventilation, side ventilation, are numerically investigated for a typical marine data center. Four independent parameters, including temperature, velocity, air age, and uniformity index, are applied to evaluate the performances of the three ventilation modes. Further, the analytic hierarchy process (AHP) entropy weight model is established and further analysis is conducted to find the optimal ventilation mode of the marine data center. The results indicate that the underfloor ventilation mode has the best performance in the airflow patterns and temperature distribution evaluation projects, with the highest scores of 91.84 and 90.60. If low energy consumption is required, it is recommended to select the overhead ventilation mode with a maximum score of 93.50. The current evaluation results agree fairly well with the three dimensional simulation results, which further proves that the AHP entropy weight method is reasonable and has a high adaptability for the evaluation of air conditioning ventilation modes.
Open AccessOptimization and Evaluation of Ventilation Mode in Marine Data Center Based on AHP-Entropy Weight
The ventilation mode affects the cooling efficiency of the air conditioners significantly in marine data centers. Three different ventilation modes, namely, underfloor ventilation, overhead ventilation, side ventilation, are numerically investigated for a typical marine data center. Four independent parameters, including temperature, velocity, air age, and uniformity index, are applied to evaluate the performances of the three ventilation modes. Further, the analytic hierarchy process (AHP) entropy weight model is established and further analysis is conducted to find the optimal ventilation mode of the marine data center. The results indicate that the underfloor ventilation mode has the best performance in the airflow patterns and temperature distribution evaluation projects, with the highest scores of 91.84 and 90.60. If low energy consumption is required, it is recommended to select the overhead ventilation mode with a maximum score of 93.50. The current evaluation results agree fairly well with the three dimensional simulation results, which further proves that the AHP entropy weight method is reasonable and has a high adaptability for the evaluation of air conditioning ventilation modes.