Abdelghani Yahiou
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Abdelghani Yahiou has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Abdelhafid Bayadi
Department of Electrical Engineering, Faculty of Technology Ferhat Abbas Setif 1 University Sétif Algeria
3 shared publications- Badreddine Babes
Research Center in Industrial Technologies (CRTI), Algiers, Algeria
3 shared publications - Carlo Cecati
Department of Information Engineering, Computer Science and Mathematics, University of L’Aquila, L’Aquila, Italy
1 shared publication - Hacene Mellah
University of Bouira
1 shared publication - Hamza Sahraoui
Universit Ferhat Abbas Setif1,Dpartement dlectrotechnique,Stif,Algeria
1 shared publication - Kamel Eddine Hemsas
LAS Laboratory, Department of Electrical Engineering, Faculty of Technology, Ferhat Abbas University Setif-1, Campus El Bez, Setif 19137, Algeria
1 shared publication
Latest Publications
- 6 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2102-2108
Comparing performances of three CFNN used for DC machine combined parameter and states estimation
The main idea of this paper is for evaluation and make a performance comparison between three types of learning algorithms in the case of simultaneous estimation of parameter and states of a brushed DC machine. Three Cascade Forward Neural Network (CFNN) estimators have been designed, the first one is based on Quasi-Newton BFGS backpropagation (BFGSBP), the second one is based on Resilient backpropagation (RBP) and the last one is based on Bayesian Regularization backpropagation (BRBP). All this neural network use just voltage and current as imputes and estimates simultaneously speed, temperature and armature resistance. A series of simulation have been carried out for three algorithms and the results were compared between them for each Artificial Neural Network (ANN) outputs. The comparative study of the time required to converge for each supposed MSE, present the trade-off between fastness and convergence of three algorithms in order to develop the best NN.
- 6 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2102-2108
Comparing performances of three CFNN used for DC machine combined parameter and states estimation
The main idea of this paper is for evaluation and make a performance comparison between three types of learning algorithms in the case of simultaneous estimation of parameter and states of a brushed DC machine. Three Cascade Forward Neural Network (CFNN) estimators have been designed, the first one is based on Quasi-Newton BFGS backpropagation (BFGSBP), the second one is based on Resilient backpropagation (RBP) and the last one is based on Bayesian Regularization backpropagation (BRBP). All this neural network use just voltage and current as imputes and estimates simultaneously speed, temperature and armature resistance. A series of simulation have been carried out for three algorithms and the results were compared between them for each Artificial Neural Network (ANN) outputs. The comparative study of the time required to converge for each supposed MSE, present the trade-off between fastness and convergence of three algorithms in order to develop the best NN.
- 14 August 2019
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 47 (10) , 1664-1679
Modified method for transformer magnetizing characteristic computation and point‐on‐wave control switching for inrush current mitigation
Summary: This paper proposes a new model for the low‐frequency transient analysis of a transformer, with a modified equation for calculation of the flux‐current characteristic representing the saturation inductance of the transformer. The model is based on the V‐I (voltage‐current) no‐load curves and uses the no‐load reactive power losses. To validate the model, it was used to simulate the no‐load magnetizing current in steady‐state condition, as well as the transient inrush current at network frequency. Evaluation was done both by comparing the simulation results obtained with the proposed model and those available in the relevant literature, and by practical measurements. The experimental results presented in this paper were obtained via a laboratory setup and a data acquisition system based on the dSPACE board 1104. Moreover, a control switching to mitigate the transient inrush current in a transformer was developed and applied experimentally in the laboratory and also in the simulations. This control strategy was performed by taking into account the residual flux at the opening instant of the related circuit breaker. A comparative study was carried out showing the validity of the proposed model and the mitigation technique.
- 14 August 2019
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 47 (10) , 1664-1679
Modified method for transformer magnetizing characteristic computation and point‐on‐wave control switching for inrush current mitigation
Summary: This paper proposes a new model for the low‐frequency transient analysis of a transformer, with a modified equation for calculation of the flux‐current characteristic representing the saturation inductance of the transformer. The model is based on the V‐I (voltage‐current) no‐load curves and uses the no‐load reactive power losses. To validate the model, it was used to simulate the no‐load magnetizing current in steady‐state condition, as well as the transient inrush current at network frequency. Evaluation was done both by comparing the simulation results obtained with the proposed model and those available in the relevant literature, and by practical measurements. The experimental results presented in this paper were obtained via a laboratory setup and a data acquisition system based on the dSPACE board 1104. Moreover, a control switching to mitigate the transient inrush current in a transformer was developed and applied experimentally in the laboratory and also in the simulations. This control strategy was performed by taking into account the residual flux at the opening instant of the related circuit breaker. A comparative study was carried out showing the validity of the proposed model and the mitigation technique.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Mitigation of Sympathetic Inrush Current in Transformer Using the Technique of Point on Voltage Wave Control Switching
The inrush currents which generated at the energization moment of an electric transformer can reach high values and cause some abnormal problems in the power system, and the sympathetic inrush current is produced in an electrical network during the energization of a transformer with the existence of other already supplied transformers. The present work has the purpose of eliminating these transient inrush currents. So this paper presents a data acquisition system based on dSPACE board 1104, and a laboratory setup experiment to measure the sympathetic inrush current. Moreover, a control switching to mitigate the sympathetic inrush current in a 2 kVA transformer will be developed and applied experimentally in the laboratory and also in the simulations. This control strategy is performed by considering the residual flux at the opening instant of related circuit-breaker. A comparative study is carried out showing the validity of the mitigation technique.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Mitigation of Sympathetic Inrush Current in Transformer Using the Technique of Point on Voltage Wave Control Switching
The inrush currents which generated at the energization moment of an electric transformer can reach high values and cause some abnormal problems in the power system, and the sympathetic inrush current is produced in an electrical network during the energization of a transformer with the existence of other already supplied transformers. The present work has the purpose of eliminating these transient inrush currents. So this paper presents a data acquisition system based on dSPACE board 1104, and a laboratory setup experiment to measure the sympathetic inrush current. Moreover, a control switching to mitigate the sympathetic inrush current in a 2 kVA transformer will be developed and applied experimentally in the laboratory and also in the simulations. This control strategy is performed by considering the residual flux at the opening instant of related circuit-breaker. A comparative study is carried out showing the validity of the mitigation technique.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Point on Voltage Wave Switching for Sympathetic Inrush Current Reduction
The present work has the purpose of eliminating these transient inrush currents. So this paper presents a data acquisition system based on dSPACE board 1104, and a laboratory setup experiment to measure the sympathetic inrush current. Moreover, a control switching to mitigate the sympathetic inrush current in a 2 kVA transformer will be developed and applied experimentally in the laboratory and also in the simulations. This control strategy is performed by considering the residual flux at the opening instant of related circuit-breaker. A comparative study is carried out showing the validity of the mitigation technique.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Point on Voltage Wave Switching for Sympathetic Inrush Current Reduction
The present work has the purpose of eliminating these transient inrush currents. So this paper presents a data acquisition system based on dSPACE board 1104, and a laboratory setup experiment to measure the sympathetic inrush current. Moreover, a control switching to mitigate the sympathetic inrush current in a 2 kVA transformer will be developed and applied experimentally in the laboratory and also in the simulations. This control strategy is performed by considering the residual flux at the opening instant of related circuit-breaker. A comparative study is carried out showing the validity of the mitigation technique.