Hassan Fawzy Elattar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hassan Fawzy Elattar has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Hassanein Abdelmohsen Refaey
Department of Mechanical Engineering, College of Engineering in Yanbu, Taibah University, Yanbu Al-Bahr 46421, Saudi Arabia
7 shared publications A. Fouda
4 shared publications- Mathkar A. Alharthi
Department of Chemical Engineering, College of Engineering at Yanbu, Taibah University, P.O. Box 4050, Yanbu Al-Bahr 41911, Saudi Arabia
4 shared publications Ali Fouda
Department of Mechanical and Materials Engineering, Faculty of Engineering, University of Jeddah, Jeddah, Saudi Arabia
3 shared publications- Ali Fouda
Department of Mechanical and Materials Engineering, Faculty of Engineering, University of Jeddah, Jeddah 21589, Saudi Arabia
3 shared publications - Fahad Awjah Almehmadi
Department of Applied Mechanical Engineering, College of Applied Engineering, Muzahimiyah Branch, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia
3 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- Vol. 30 (1 Part B) , 575-589
Improving automotive air conditioning systems' (AACs) thermodynamic performance with eco-friendly azeotropic refrigerant blends
Automotive air conditioning (AAC) systems traditionally use high-GWP refrigerants, raising environmental concerns. To address this, new azeotropic refrigerant blends, R513A, R513B, R515A, R515B, and R516A, have been developed. These blends offer environmentally friendly alternatives with promising thermodynamic performance. The R513A and R513B are suitable replacements for R1234yf and R134a with minimal system modifications, while R516A provides the highest cooling capacity (16.54 kW) and maximum optimal COP (39.84), making it highly effective. The R515A ensures low GWP and compressor temperatures, whereas R513A and R513B optimize energy efficiency and safety. Notably, R513A and R513B exhibit the lowest compression ratio, ?, and highest COP values (5.79, 7.23, and 9.40) across various evaporator temperatures, making them ideal for energy-saving applications. Overall, azeotropic refrigerants outperform R1234yf in COP, cooling capacity, and safety, while offering environmentally sustainable solutions for AAC.
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- Vol. 30 (1 Part B) , 575-589
Open AccessImproving automotive air conditioning systems' (AACs) thermodynamic performance with eco-friendly azeotropic refrigerant blends
Automotive air conditioning (AAC) systems traditionally use high-GWP refrigerants, raising environmental concerns. To address this, new azeotropic refrigerant blends, R513A, R513B, R515A, R515B, and R516A, have been developed. These blends offer environmentally friendly alternatives with promising thermodynamic performance. The R513A and R513B are suitable replacements for R1234yf and R134a with minimal system modifications, while R516A provides the highest cooling capacity (16.54 kW) and maximum optimal COP (39.84), making it highly effective. The R515A ensures low GWP and compressor temperatures, whereas R513A and R513B optimize energy efficiency and safety. Notably, R513A and R513B exhibit the lowest compression ratio, ?, and highest COP values (5.79, 7.23, and 9.40) across various evaporator temperatures, making them ideal for energy-saving applications. Overall, azeotropic refrigerants outperform R1234yf in COP, cooling capacity, and safety, while offering environmentally sustainable solutions for AAC.
- 2 July 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 278
Efficient CO2 cooling/power system for refrigerated trucks using exhaust heat recovery
- 2 July 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 278
Efficient CO2 cooling/power system for refrigerated trucks using exhaust heat recovery
- Open Access
- 3 June 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 73
Experimental analysis and multilayer perceptron ANN prediction of local Nusselt number for turbulent air jet impinging upon a plane surface
- 3 June 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 73
Open AccessExperimental analysis and multilayer perceptron ANN prediction of local Nusselt number for turbulent air jet impinging upon a plane surface
- Open Access
Thermodynamic and Exergetic Evaluation of a Newly Designed CSP Driven Cooling-Desalination Cogeneration System
This investigation attempts to develop a tower solar collector-based system designed for the cogeneration of cooling and desalination. The traditional organic Rankine cycle (ORC) integrated with the ejector refrigeration cycle generates limited power and cooling at a single temperature. Acknowledging their limitations, our present study uses an organic flash cycle (OFC) supported by solar heat combined with the two-phase ejector cycle and the reverse osmosis (RO) desalination unit. Since the OFC turbine is fed with two extra streams of fluid, therefore, it provides greater power to run the compressor of the ejector and pumps of the RO unit, resulting in the production of cooling at two different temperatures (refrigeration and air conditioning) and a higher mass flow rate of fresh water. A mathematical model is employed to assess the impact of coil curvature ratio, Rib height, and direct normal irradiation (DNI) on the temperature of the collector’s oil outlet. ANSYS-FLUENT conducts numerical simulations through computational fluid dynamics (CFD) analysis. The results indicate an ultimate increase in oil outlet temperature of 45% as the DNI increased from 450 to 1000 W/m2 at a curvature ratio of 0.095 when employing the 1st Rib. Further, a steady-state energy and exergy analysis is conducted to evaluate the performance of the proposed cogeneration, with different design parameters like DNI, coil curvature ratio, rib height, and OFC turbine inlet pressure. The energetic and exergetic efficiencies of the cogeneration system at DNI of 800 W/m2 are obtained as 16.67% and 6.08%, respectively. Exergetic assessment of the overall system shows that 29.57% is the exergy produced as cooling exergy, and the exergy accompanied by freshwater, 68.13%, is the exergy destroyed, and 2.3% is the exergy loss. The solar collector exhibits the maximum exergy destruction, followed by the ejector and RO pumps. Integrating multiple technologies into a system with solar input enhances efficiency, energy sustainability, and environmental benefits.
Open AccessThermodynamic and Exergetic Evaluation of a Newly Designed CSP Driven Cooling-Desalination Cogeneration System
This investigation attempts to develop a tower solar collector-based system designed for the cogeneration of cooling and desalination. The traditional organic Rankine cycle (ORC) integrated with the ejector refrigeration cycle generates limited power and cooling at a single temperature. Acknowledging their limitations, our present study uses an organic flash cycle (OFC) supported by solar heat combined with the two-phase ejector cycle and the reverse osmosis (RO) desalination unit. Since the OFC turbine is fed with two extra streams of fluid, therefore, it provides greater power to run the compressor of the ejector and pumps of the RO unit, resulting in the production of cooling at two different temperatures (refrigeration and air conditioning) and a higher mass flow rate of fresh water. A mathematical model is employed to assess the impact of coil curvature ratio, Rib height, and direct normal irradiation (DNI) on the temperature of the collector’s oil outlet. ANSYS-FLUENT conducts numerical simulations through computational fluid dynamics (CFD) analysis. The results indicate an ultimate increase in oil outlet temperature of 45% as the DNI increased from 450 to 1000 W/m2 at a curvature ratio of 0.095 when employing the 1st Rib. Further, a steady-state energy and exergy analysis is conducted to evaluate the performance of the proposed cogeneration, with different design parameters like DNI, coil curvature ratio, rib height, and OFC turbine inlet pressure. The energetic and exergetic efficiencies of the cogeneration system at DNI of 800 W/m2 are obtained as 16.67% and 6.08%, respectively. Exergetic assessment of the overall system shows that 29.57% is the exergy produced as cooling exergy, and the exergy accompanied by freshwater, 68.13%, is the exergy destroyed, and 2.3% is the exergy loss. The solar collector exhibits the maximum exergy destruction, followed by the ejector and RO pumps. Integrating multiple technologies into a system with solar input enhances efficiency, energy sustainability, and environmental benefits.
- Open Access
- 20 May 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 59
Evaluation of a concentrated solar power-driven system designed for combined production of cooling and hydrogen
- 20 May 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 59
Open AccessEvaluation of a concentrated solar power-driven system designed for combined production of cooling and hydrogen
- Open Access
Fluid Flow Characteristics for Four Lattice Settings in Brick Tunnel Kiln: CFD Simulations
The higher the process efficiency, the lower the fuel consumption, and the less impact carbon emissions have on the environment. The flow characteristics around brick settings are an important field of investigation to acquire control over the energy intake and production process. The current work is a numerical CFD investigation to demonstrate fluid flow characterization inside the cooling zone in a brick tunnel kiln for lattice settings (the number of bricks in each layer is identical). Four different lattice settings were examined, and three were validated with published experimental data (settings 1, 2 and 3). In the current study, the BSL κ-ω turbulent model agrees well with the published experimental results. The numerical investigation presents the flow characteristics through four different lattice brick settings (e.g., velocity vectors, velocity contours and streamlines) that could not be measured experimentally. The investigation also looks at the flow zones of the vortex formation upstream, downstream and through the brick column. It was discovered that for settings 1 and 11, the quick air flow in the wall channels is much greater than in the column channels. Setting 3 has a larger vortex formation region, whereas setting 1 has a weaker vortex than the other settings. The cooling of the lattice bricks in Setting 3 is superior to the cooling in the other settings.
Open AccessFluid Flow Characteristics for Four Lattice Settings in Brick Tunnel Kiln: CFD Simulations
The higher the process efficiency, the lower the fuel consumption, and the less impact carbon emissions have on the environment. The flow characteristics around brick settings are an important field of investigation to acquire control over the energy intake and production process. The current work is a numerical CFD investigation to demonstrate fluid flow characterization inside the cooling zone in a brick tunnel kiln for lattice settings (the number of bricks in each layer is identical). Four different lattice settings were examined, and three were validated with published experimental data (settings 1, 2 and 3). In the current study, the BSL κ-ω turbulent model agrees well with the published experimental results. The numerical investigation presents the flow characteristics through four different lattice brick settings (e.g., velocity vectors, velocity contours and streamlines) that could not be measured experimentally. The investigation also looks at the flow zones of the vortex formation upstream, downstream and through the brick column. It was discovered that for settings 1 and 11, the quick air flow in the wall channels is much greater than in the column channels. Setting 3 has a larger vortex formation region, whereas setting 1 has a weaker vortex than the other settings. The cooling of the lattice bricks in Setting 3 is superior to the cooling in the other settings.
- Open Access
- 1 January 2023
- Published by National Library of Serbia in Thermal Science
- Vol. 27 (5 Part B) , 3921-3938
Impact of P-1 radiation model on simulated free jet flame characteristics of gaseous fuels: CFD with PDF approach
Simulation and analysis of a turbulent free jet flame erupting into still air are done using computational fluid dynamics (CFD). Using 2D axisymmetric numerical modeling in ANSYS-Fluent 14.5. Three distinct kinds of gaseous fuels are used: methane, carbon monoxide, and Biogas (50 % CH4 and 50 % CO2). The effects of thermal radiation modeling utilizing the P-1 radiation model on the behavior of a free jet flame are investigated, and the impacts of air temperature and fuel velocity on the flame length are also provided. The findings demonstrated that the radiation modeling did not affect the temperature distribution and flame length for CO and Biogas (i.e., lower heating value fuels). Nevertheless, the air temperature and fuel kind considerably impact the flame behavior. While the fuel inlet velocity (i.e., burner power) does not affect the flame length. Additionally, free jet flame velocity and length numerical correlations considering radiation modeling are predicted and presented with allowable errors. A comparison with earlier experimental correlation proved successful, with a maximum error of ±9.4%.
- 1 January 2023
- Published by National Library of Serbia in Thermal Science
- Vol. 27 (5 Part B) , 3921-3938
Open AccessImpact of P-1 radiation model on simulated free jet flame characteristics of gaseous fuels: CFD with PDF approach
Simulation and analysis of a turbulent free jet flame erupting into still air are done using computational fluid dynamics (CFD). Using 2D axisymmetric numerical modeling in ANSYS-Fluent 14.5. Three distinct kinds of gaseous fuels are used: methane, carbon monoxide, and Biogas (50 % CH4 and 50 % CO2). The effects of thermal radiation modeling utilizing the P-1 radiation model on the behavior of a free jet flame are investigated, and the impacts of air temperature and fuel velocity on the flame length are also provided. The findings demonstrated that the radiation modeling did not affect the temperature distribution and flame length for CO and Biogas (i.e., lower heating value fuels). Nevertheless, the air temperature and fuel kind considerably impact the flame behavior. While the fuel inlet velocity (i.e., burner power) does not affect the flame length. Additionally, free jet flame velocity and length numerical correlations considering radiation modeling are predicted and presented with allowable errors. A comparison with earlier experimental correlation proved successful, with a maximum error of ±9.4%.
- Open Access
Performance Evaluation of a Solar Heat-Driven Poly-Generation System for Residential Buildings Using Various Arrangements of Heat Recovery Units
Poly-generation systems are a feasible alternative to conventional energy production techniques in buildings. A poly-generation system allows for the concurrent production of electricity, heat, cold, and fresh water, with considerable advantages regarding technology, finances, energy recovery, and the environment. In the present study, the organic Rankine cycle (ORC), the humidification–dehumidification desalination system (HDH), and the desiccant cooling system (DCS) are merged with three unique solar-driven poly-generation systems (BS, IS-I, and IS-II) and numerically examined. The proposed options provide energy, space cooling, domestic heating, and potable water to buildings of small/medium scale. Using n-octane ORC working fluid, the impact of operational circumstances on system productivity and execution characteristics was considered. The findings show that (i) the suggested poly-generation systems can provide electrical power, conditioned space cooling, local heating, and fresh water, whereas keeping the conditioned area pleasant, (ii) the IS-I system achieves the best system performance among all compared arrangements (BS and IS-II); (iii) the attained extreme values of , , , , and TGOR are 102.0 kW (all systems), 214.70 kg/h (IS-II), 29.940 kW (IS-II), 225.6 kW (IS-I), and 0.6303 (IS-I), respectively.Open AccessPerformance Evaluation of a Solar Heat-Driven Poly-Generation System for Residential Buildings Using Various Arrangements of Heat Recovery Units
Poly-generation systems are a feasible alternative to conventional energy production techniques in buildings. A poly-generation system allows for the concurrent production of electricity, heat, cold, and fresh water, with considerable advantages regarding technology, finances, energy recovery, and the environment. In the present study, the organic Rankine cycle (ORC), the humidification–dehumidification desalination system (HDH), and the desiccant cooling system (DCS) are merged with three unique solar-driven poly-generation systems (BS, IS-I, and IS-II) and numerically examined. The proposed options provide energy, space cooling, domestic heating, and potable water to buildings of small/medium scale. Using n-octane ORC working fluid, the impact of operational circumstances on system productivity and execution characteristics was considered. The findings show that (i) the suggested poly-generation systems can provide electrical power, conditioned space cooling, local heating, and fresh water, whereas keeping the conditioned area pleasant, (ii) the IS-I system achieves the best system performance among all compared arrangements (BS and IS-II); (iii) the attained extreme values of , , , , and TGOR are 102.0 kW (all systems), 214.70 kg/h (IS-II), 29.940 kW (IS-II), 225.6 kW (IS-I), and 0.6303 (IS-I), respectively. - Open Access
Energy Performance Assessment of a Novel Solar Poly-Generation System Using Various ORC Working Fluids in Residential Buildings
Poly-generation systems are an exciting new technology that provide an alternative to separating existing energy production methods in buildings. A poly-generation system enables the efficient simultaneous production of heating, cooling, fresh water, and electricity, resulting in many technological, economic, energy recovery, and environmental advantages. This study numerically investigates three proposed novel solar-driven poly-generation systems (BS, IS-I, and IS-II) integrated with organic Rankine cycle (ORC), humidification-dehumidification desalination system (HDH), and desiccant cooling system (DCS) with different heat recovery system arrangements. The suggested systems supply residential structures with energy, space conditioning, domestic heating, and fresh water. The effects of system operating circumstances on productivity and performance characteristics and several organic working fluid types (n-octane, R245fa, R113, isopentane, and toluene) on optimum system performance have been investigated. The results show that (i) the average enhancement percentage of TGOR using integrated poly-generation systems over the separated ones is 68.5%, 68.5%, and 95.5% for BS, IS-I, and IS-II systems, respectively; (ii) when comparing the three systems, the IS-I system outperforms the other systems (BS & IS-II); and (iii) the maximum values of W•net, m•fresh, Q•cooling, and Q•heating, obtained for different proposed systems using n-octane are 102 kW (all systems), 214.7 kg/h (IS-II), 29.94 kW (IS-II), and 225.6 kW (IS-I); (iv) R113 has the highest TGOR of 0.6924 (IS-I) compared to other organic fluids. (v) The improvements in , , and with using toluene instead of R113 at tf1 = 40 °C are 177.5%, 105.8%, 389.25%, and 79%, respectively.Open AccessEnergy Performance Assessment of a Novel Solar Poly-Generation System Using Various ORC Working Fluids in Residential Buildings
Poly-generation systems are an exciting new technology that provide an alternative to separating existing energy production methods in buildings. A poly-generation system enables the efficient simultaneous production of heating, cooling, fresh water, and electricity, resulting in many technological, economic, energy recovery, and environmental advantages. This study numerically investigates three proposed novel solar-driven poly-generation systems (BS, IS-I, and IS-II) integrated with organic Rankine cycle (ORC), humidification-dehumidification desalination system (HDH), and desiccant cooling system (DCS) with different heat recovery system arrangements. The suggested systems supply residential structures with energy, space conditioning, domestic heating, and fresh water. The effects of system operating circumstances on productivity and performance characteristics and several organic working fluid types (n-octane, R245fa, R113, isopentane, and toluene) on optimum system performance have been investigated. The results show that (i) the average enhancement percentage of TGOR using integrated poly-generation systems over the separated ones is 68.5%, 68.5%, and 95.5% for BS, IS-I, and IS-II systems, respectively; (ii) when comparing the three systems, the IS-I system outperforms the other systems (BS & IS-II); and (iii) the maximum values of W•net, m•fresh, Q•cooling, and Q•heating, obtained for different proposed systems using n-octane are 102 kW (all systems), 214.7 kg/h (IS-II), 29.94 kW (IS-II), and 225.6 kW (IS-I); (iv) R113 has the highest TGOR of 0.6924 (IS-I) compared to other organic fluids. (v) The improvements in , , and with using toluene instead of R113 at tf1 = 40 °C are 177.5%, 105.8%, 389.25%, and 79%, respectively. - Open Access
- 3 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (21) , 11157
Towards an Efficient Multi-Generation System Providing Power, Cooling, Heating, and Freshwater for Residential Buildings Operated with Solar-Driven ORC
In buildings, multi-generation systems are a promising technology that can replace discrete traditional energy production methods. A multi-generation system makes it possible to efficiently produce electricity, cooling, heating, and freshwater simultaneously. This study involved the numerical analysis of a modified proposed novel solar-driven multi-generation system (MGS-II) integrated with the Organic Rankine Cycle (ORC), Humidification–Dehumidification Desalination System (HDH), and Desiccant Cooling System (DCS) by using heat recovery and thermal energy storage (TES) units. In addition, a comparison study with the basic multi-generation system (MGS-I) is performed. The proposed system is designed to supply electricity, air conditioning, domestic heating, and fresh water to small/medium-sized buildings. How operating conditions affect system productivity and performance metrics have been investigated. The results show that the proposed multi-generation system (MGS-II) can produce electrical power, space cooling, domestic heating and fresh water while maintaining comfortable conditions inside the conditioned space. Moreover, the MGS-II outperforms the MGS-I system, and the maximum MGS-II system productivity; electricity production (\({W_{net}^{\bullet}}\)), freshwater (\({m_{fresh}^{\bullet} }\)), space cooling (\({Q_{cooling}^{\bullet} }\)), and domestic heating (\({Q_{heating}^{\bullet} }\)) are 102.3 kW, 141.5 kg/h, 20.77 kW, and 225 kW, respectively. In addition, the highest total gained output ratio (TGOR), specific total gained energy (STG), and specific total gained energy equivalent price (STGP) of the MGS-II system are 0.6303, 3.824 kWh/m2, and 0.149 USD/m2, respectively. The accepted ranges of comfortable space-supplied air conditions (temperature and humidity) are 15.5–18.2 °C and 9.2–12.00 gv/kga for both systems, MGS-I and MGS-II. Finally, the current system (MGS-II) has the maximum of the system’s performance indicators and productivity (TGOR and \({{\overset{.}{m}}_{fresh} }\)) compared with the other reported systems.- 3 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (21) , 11157
Open AccessTowards an Efficient Multi-Generation System Providing Power, Cooling, Heating, and Freshwater for Residential Buildings Operated with Solar-Driven ORC
In buildings, multi-generation systems are a promising technology that can replace discrete traditional energy production methods. A multi-generation system makes it possible to efficiently produce electricity, cooling, heating, and freshwater simultaneously. This study involved the numerical analysis of a modified proposed novel solar-driven multi-generation system (MGS-II) integrated with the Organic Rankine Cycle (ORC), Humidification–Dehumidification Desalination System (HDH), and Desiccant Cooling System (DCS) by using heat recovery and thermal energy storage (TES) units. In addition, a comparison study with the basic multi-generation system (MGS-I) is performed. The proposed system is designed to supply electricity, air conditioning, domestic heating, and fresh water to small/medium-sized buildings. How operating conditions affect system productivity and performance metrics have been investigated. The results show that the proposed multi-generation system (MGS-II) can produce electrical power, space cooling, domestic heating and fresh water while maintaining comfortable conditions inside the conditioned space. Moreover, the MGS-II outperforms the MGS-I system, and the maximum MGS-II system productivity; electricity production (\({W_{net}^{\bullet}}\)), freshwater (\({m_{fresh}^{\bullet} }\)), space cooling (\({Q_{cooling}^{\bullet} }\)), and domestic heating (\({Q_{heating}^{\bullet} }\)) are 102.3 kW, 141.5 kg/h, 20.77 kW, and 225 kW, respectively. In addition, the highest total gained output ratio (TGOR), specific total gained energy (STG), and specific total gained energy equivalent price (STGP) of the MGS-II system are 0.6303, 3.824 kWh/m2, and 0.149 USD/m2, respectively. The accepted ranges of comfortable space-supplied air conditions (temperature and humidity) are 15.5–18.2 °C and 9.2–12.00 gv/kga for both systems, MGS-I and MGS-II. Finally, the current system (MGS-II) has the maximum of the system’s performance indicators and productivity (TGOR and \({{\overset{.}{m}}_{fresh} }\)) compared with the other reported systems.