J. Alex
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
J. Alex has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Leiv Rieger
InCTRL Solutions Inc., Oakville, Ontario, Canada
3 shared publications - S. Winkler
Institute of Water Quality and Waste Management, Vienna University of Technology, A - 1040 Vienna, Karlsplatz 13/E 226, Austria
3 shared publications H. Siegrist
EAWAG, Swiss Federal Institute for Environmental Science and Technology, Ueberlandstrasse 133, PO Box 611, 8600 Duebendorf, Switzerland
2 shared publications- C. Owerdieck
Dept. of Environmental Engineering, RWTH-Aachen, Germany
1 shared publication - Gerd Kolisch
Wupperverbandsgesellschaft für integrale Wasserwirtschaft mbH, Untere Lichtenplatzer Straße 100, 42289 Wuppertal, Germany
1 shared publication - Guenter Langergraber
Department of Water, Atmosphere and Environment, Institute of Sanitary Engineering and Water Pollution Control, University of Natural Resources and Life Sciences, Vienna (BOKU), Muthgasse 18, 1190 Vienna, Austria
1 shared publication
Latest Publications
- 1 October 2004
- Published by IWA Publishing in Water Science & Technology
- Vol. 50 (7) , 131-138
A guideline for simulation studies of wastewater treatment plants
A guideline for simulation studies of wastewater treatment plants is proposed. The aim of the HSG-guideline is to define a reference quality level that helps to make the results of simulation studies comprehensible and comparable and therefore increases the quality and reliability of mathematical modelling in wastewater treatment. The paper gives a summary of the HSG-guideline, written by a group of university members from Germany, Austria and Switzerland.
- 1 October 2004
- Published by IWA Publishing in Water Science & Technology
- Vol. 50 (7) , 131-138
A guideline for simulation studies of wastewater treatment plants
A guideline for simulation studies of wastewater treatment plants is proposed. The aim of the HSG-guideline is to define a reference quality level that helps to make the results of simulation studies comprehensible and comparable and therefore increases the quality and reliability of mathematical modelling in wastewater treatment. The paper gives a summary of the HSG-guideline, written by a group of university members from Germany, Austria and Switzerland.
- 1 January 2003
- Published by IWA Publishing in Water Science & Technology
- Vol. 47 (2) , 103-112
Progress in sensor technology - progress in process control? Part I: Sensor property investigation and classification
To ensure correctly operating control systems, the measurement and control equipment in WWTPs must be mutually consistent. The dynamic simulation of activated sludge systems could offer a suitable tool for designing and optimising control strategies. Ideal or simplified sensor models represent a limiting factor for comparability with field applications. More realistic sensor models are therefore required. Two groups of sensor models are proposed on the basis of field and laboratory tests: one for specific sensors and another for a classification of sensor types to be used with the COST simulation benchmark environment. This should lead to a more realistic test environment and allow control engineers to define the requirements of the measuring equipment as a function of the selected control strategy.
- 1 January 2003
- Published by IWA Publishing in Water Science & Technology
- Vol. 47 (2) , 103-112
Progress in sensor technology - progress in process control? Part I: Sensor property investigation and classification
To ensure correctly operating control systems, the measurement and control equipment in WWTPs must be mutually consistent. The dynamic simulation of activated sludge systems could offer a suitable tool for designing and optimising control strategies. Ideal or simplified sensor models represent a limiting factor for comparability with field applications. More realistic sensor models are therefore required. Two groups of sensor models are proposed on the basis of field and laboratory tests: one for specific sensors and another for a classification of sensor types to be used with the COST simulation benchmark environment. This should lead to a more realistic test environment and allow control engineers to define the requirements of the measuring equipment as a function of the selected control strategy.
- 1 January 2003
- Published by IWA Publishing in Water Science & Technology
- Vol. 47 (2) , 113-120
Progress in sensor technology - progress in process control? Part II: results from a simulation benchmark study
To show the impact of sensor behaviour on the control result, four strategies for aeration control are tested using different sensor characteristics. It is demonstrated, on the one hand, how an increasing response time will limit the achievable control quality and, on the other hand, how a given sensor characteristic can be taken into account for the controller design. The presented tests show that an improvement potential by control for WWTPs is available but this potential is limited compared to proper DO control with fixed set-points. To activate this control potential, sufficient control authority must be available and a careful control design is required. It can be shown that using feedback control, sensors with a small response time have significant advantages compared to conventional sensors. Using feed forward control, the improvement potential by control is considerably higher and additionally, the sensor delay can be integrated into the controller design. The presented discussion is based on simulation studies performed on a standardised benchmark case. For these tests it was necessary to include sensor models into the simulation model. It can be stated that the usage of sensor models is necessary for the application of dynamic simulation for the design and evaluation of WWTP control and in general to achieve realistic results.
- 1 January 2003
- Published by IWA Publishing in Water Science & Technology
- Vol. 47 (2) , 113-120
Progress in sensor technology - progress in process control? Part II: results from a simulation benchmark study
To show the impact of sensor behaviour on the control result, four strategies for aeration control are tested using different sensor characteristics. It is demonstrated, on the one hand, how an increasing response time will limit the achievable control quality and, on the other hand, how a given sensor characteristic can be taken into account for the controller design. The presented tests show that an improvement potential by control for WWTPs is available but this potential is limited compared to proper DO control with fixed set-points. To activate this control potential, sufficient control authority must be available and a careful control design is required. It can be shown that using feedback control, sensors with a small response time have significant advantages compared to conventional sensors. Using feed forward control, the improvement potential by control is considerably higher and additionally, the sensor delay can be integrated into the controller design. The presented discussion is based on simulation studies performed on a standardised benchmark case. For these tests it was necessary to include sensor models into the simulation model. It can be stated that the usage of sensor models is necessary for the application of dynamic simulation for the design and evaluation of WWTP control and in general to achieve realistic results.
- 1 January 2003
- Published by IWA Publishing in Water Science & Technology
- Vol. 47 (2) , 205-211
On-line measurement data of wastewater systems via WAP mobile phones
In order to support the operation of wastewater systems a system was developed which allows us to access plant data by standard mobile devices such as WAP mobile phones. This system is suited to complement the standard application of alarm and message systems based for example on SMS or pager services. This technology provides useful options for mobile remote monitoring and remote control of automated plants. This technology is particularly appropriate for the use in remote facilities where no staff is available. The technology has been implemented succesfully and shows how standard IT and Internet technologies can be utilised to support the operation of spatially distributed plants with reasonable effort. Two implementations are presented which access plant data via WAP mobile phones and via mobile pocket PCs. First application experiences are presented.
- 1 January 2003
- Published by IWA Publishing in Water Science & Technology
- Vol. 47 (2) , 205-211
On-line measurement data of wastewater systems via WAP mobile phones
In order to support the operation of wastewater systems a system was developed which allows us to access plant data by standard mobile devices such as WAP mobile phones. This system is suited to complement the standard application of alarm and message systems based for example on SMS or pager services. This technology provides useful options for mobile remote monitoring and remote control of automated plants. This technology is particularly appropriate for the use in remote facilities where no staff is available. The technology has been implemented succesfully and shows how standard IT and Internet technologies can be utilised to support the operation of spatially distributed plants with reasonable effort. Two implementations are presented which access plant data via WAP mobile phones and via mobile pocket PCs. First application experiences are presented.
- 1 February 2002
- Published by IWA Publishing in Water Science & Technology
- Vol. 45 (4-5) , 325-334
Model structure identification for wastewater treatment simulation based on computational fluid dynamics
The objective of this presented project is to use the results of an CFD simulation to automatically, systematically and reliably generate an appropriate model structure for simulation of the biological processes using CSTR activated sludge compartments. Models and dynamic simulation have become important tools for research but also increasingly for the design and optimisation of wastewater treatment plants. Besides the biological models several cases are reported about the application of computational fluid dynamics (CFD) to wastewater treatment plants. One aim of the presented method to derive model structures from CFD results is to exclude the influence of empirical structure selection to the result of dynamic simulations studies of WWTPs. The second application of the approach developed is the analysis of badly performing treatment plants where the suspicion arises that bad flow behaviour such as short cut flows is part of the problem. The method suggested requires as the first step the calculation of fluid dynamics of the biological treatment step at different loading situations by use of 3-dimensional CFD simulation. The result of this information is used to generate a suitable model structure for conventional dynamic simulation of the treatment plant by use of a number of CSTR modules with a pattern of exchange flows between the tanks automatically. The method is explained in detail and the application to the WWTP Wuppertal Buchenhofen is presented.
- 1 February 2002
- Published by IWA Publishing in Water Science & Technology
- Vol. 45 (4-5) , 325-334
Model structure identification for wastewater treatment simulation based on computational fluid dynamics
The objective of this presented project is to use the results of an CFD simulation to automatically, systematically and reliably generate an appropriate model structure for simulation of the biological processes using CSTR activated sludge compartments. Models and dynamic simulation have become important tools for research but also increasingly for the design and optimisation of wastewater treatment plants. Besides the biological models several cases are reported about the application of computational fluid dynamics (CFD) to wastewater treatment plants. One aim of the presented method to derive model structures from CFD results is to exclude the influence of empirical structure selection to the result of dynamic simulations studies of WWTPs. The second application of the approach developed is the analysis of badly performing treatment plants where the suspicion arises that bad flow behaviour such as short cut flows is part of the problem. The method suggested requires as the first step the calculation of fluid dynamics of the biological treatment step at different loading situations by use of 3-dimensional CFD simulation. The result of this information is used to generate a suitable model structure for conventional dynamic simulation of the treatment plant by use of a number of CSTR modules with a pattern of exchange flows between the tanks automatically. The method is explained in detail and the application to the WWTP Wuppertal Buchenhofen is presented.
- 1 February 2002
- Published by IWA Publishing in Water Science & Technology
- Vol. 45 (4-5) , 365-372
Improved design and optimization of aeration control for WWTPs by dynamic simulation
This paper introduces a model library based on the simulation environment MATLAB/SIMULINK which allows the simulation of the aeration system of an wastewater treatment plant (WWTP). The model library presented covers all parts of an aeration system starting with the compressor set over the common air rail, flow resistances through pipes, controllable valves, aeration membranes and ending last not least with the controllers involved. The main objective of the development of the simulation system is the design, test and the support of the installation of more predictable and efficient control concepts for the aeration system in WWTPs. An example is given to demonstrate the application of the simulation system and to promote a control scheme with a flexible reference value for the pressure at the common air rail based on a most open valve (MOV) concept.
- 1 February 2002
- Published by IWA Publishing in Water Science & Technology
- Vol. 45 (4-5) , 365-372
Improved design and optimization of aeration control for WWTPs by dynamic simulation
This paper introduces a model library based on the simulation environment MATLAB/SIMULINK which allows the simulation of the aeration system of an wastewater treatment plant (WWTP). The model library presented covers all parts of an aeration system starting with the compressor set over the common air rail, flow resistances through pipes, controllable valves, aeration membranes and ending last not least with the controllers involved. The main objective of the development of the simulation system is the design, test and the support of the installation of more predictable and efficient control concepts for the aeration system in WWTPs. An example is given to demonstrate the application of the simulation system and to promote a control scheme with a flexible reference value for the pressure at the common air rail based on a most open valve (MOV) concept.
- Open Access
- 1 February 2002
- Published by IWA Publishing in Water Science & Technology
- Vol. 45 (4-5) , 485-494
Status and future trends of ICA in wastewater treatment – a European perspective
The status of instrumentation, control and automation (ICA) within the European wastewater community is reviewed and some major incentives and bottlenecks are defined. Future trends of ICA are also discussed. The information is based on a COST 624 workshop and a non-exhaustive survey with regard to ICA carried out in 13 European countries during March 2001. The level of instrumentation (type of sensors, usage frequency, etc.) and how these instruments are used for on-line control purposes are presented for each individual country (Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Netherlands, Romania, Slovenia, Spain, Sweden and Switzerland). The most common types of applied real-time control in wastewater treatment plants are given. One conclusion of the paper is that sensors no longer represent the main bottleneck for on-line control, rather the lack of plant flexibility is more troublesome. Moreover, the current transitional phase of the wastewater industry in Europe represents a unique opportunity to apply ICA on a large scale. The driving forces are simply too strong to ignore.
- 1 February 2002
- Published by IWA Publishing in Water Science & Technology
- Vol. 45 (4-5) , 485-494
Open AccessStatus and future trends of ICA in wastewater treatment – a European perspective
The status of instrumentation, control and automation (ICA) within the European wastewater community is reviewed and some major incentives and bottlenecks are defined. Future trends of ICA are also discussed. The information is based on a COST 624 workshop and a non-exhaustive survey with regard to ICA carried out in 13 European countries during March 2001. The level of instrumentation (type of sensors, usage frequency, etc.) and how these instruments are used for on-line control purposes are presented for each individual country (Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Netherlands, Romania, Slovenia, Spain, Sweden and Switzerland). The most common types of applied real-time control in wastewater treatment plants are given. One conclusion of the paper is that sensors no longer represent the main bottleneck for on-line control, rather the lack of plant flexibility is more troublesome. Moreover, the current transitional phase of the wastewater industry in Europe represents a unique opportunity to apply ICA on a large scale. The driving forces are simply too strong to ignore.
- 1 January 2002
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 35 (1) , 405-410
PREDICTIVE CONTROL OF NITROGEN REMOVAL IN WWTPS USING PARSIMONIOUS MODELS
- 1 January 2002
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 35 (1) , 405-410
PREDICTIVE CONTROL OF NITROGEN REMOVAL IN WWTPS USING PARSIMONIOUS MODELS