Shaoping Meng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shaoping Meng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Zuanfeng Pan
College of Civil Engineering, Tongji University, Shanghai 200092, China
3 shared publications - Chang Wu
Southeast University
2 shared publications - Chenhua Jin
School of Architectural Engineering, Jinling Institute of Technology, Nanjing 211169, China
2 shared publications - Yanli Su
Southeast University
2 shared publications - Chengcheng Feng
School of Civil Engineering, Southeast University, Nanjing 211189, China
1 shared publication - Chenhua Jin
School of Civil Engineering, Southeast University, Nanjing 211189, China
1 shared publication
Latest Publications
- Open Access
Experimental Study and Finite Element Modelling of Squat Shear Walls under Combined Cyclic Loads and High Axial Loads
Experimental observations on three reinforced concrete shear walls with small shear span-to-depth ratio (SDR) under combined high vertical axial load and horizontal cyclic loads are presented. The influence of high axial load ratio (ALR) on the failure mode, hysteretic behaviour, displacement ductility, shear strength and stiffness of the squat shear walls is investigated. In addition, a novel built-in strain gauges measuring system is employed for measuring the strain conditions in the reinforcements during the whole test process. Test results indicate that high axial load restrains the development of cracks and improves the shear load capacity, but that it also decreases ductility and energy dissipation and aggravates stiffness degradation. Concrete crush and out-of-plane buckling were observed in all specimens, resulting in the final failure of the specimens. According to the strain analysis, the section of the squat walls coincided well with the assumption of plane section under the condition of high ALR. With the increase of ALR, the depth of the compression zone of members increases, while the length of plastic hinge decreases. When the axial load is relatively small, the vertical and horizontal reinforcements provided almost equal contribution to the shear capacity of squat shear walls. However, under extremely high axial load, both vertical and horizontal reinforcements cannot provide full contribution to the shear capacity. The hysteretic behaviours of the tested shear walls were simulated by a cyclic softened membrane model (CSMM). Simulation results indicate that CSMM captured well the nonlinear characteristics of the squat shear wall under high axial load.
Open AccessExperimental Study and Finite Element Modelling of Squat Shear Walls under Combined Cyclic Loads and High Axial Loads
Experimental observations on three reinforced concrete shear walls with small shear span-to-depth ratio (SDR) under combined high vertical axial load and horizontal cyclic loads are presented. The influence of high axial load ratio (ALR) on the failure mode, hysteretic behaviour, displacement ductility, shear strength and stiffness of the squat shear walls is investigated. In addition, a novel built-in strain gauges measuring system is employed for measuring the strain conditions in the reinforcements during the whole test process. Test results indicate that high axial load restrains the development of cracks and improves the shear load capacity, but that it also decreases ductility and energy dissipation and aggravates stiffness degradation. Concrete crush and out-of-plane buckling were observed in all specimens, resulting in the final failure of the specimens. According to the strain analysis, the section of the squat walls coincided well with the assumption of plane section under the condition of high ALR. With the increase of ALR, the depth of the compression zone of members increases, while the length of plastic hinge decreases. When the axial load is relatively small, the vertical and horizontal reinforcements provided almost equal contribution to the shear capacity of squat shear walls. However, under extremely high axial load, both vertical and horizontal reinforcements cannot provide full contribution to the shear capacity. The hysteretic behaviours of the tested shear walls were simulated by a cyclic softened membrane model (CSMM). Simulation results indicate that CSMM captured well the nonlinear characteristics of the squat shear wall under high axial load.
- Open Access
Seismic Performance Analysis of RC Frames with ECC Short Columns Based on the IDA Method
Engineered cementitious composite (ECC) is a high-performance composite material with greater shear deformation and shear strength than normal concrete, which has been proposed for use as a shear component in structures. This study modeled three frames, a pure reinforced concrete (RC) frame, an RC frame with concrete short columns and an RC frame with ECC short columns, using the incremental dynamic analysis (IDA) method to evaluate the contribution of ECC to the structural performance. A modified IMK model was applied to model the entire history of the mechanical behaviors of the short columns. The IDA curves, interfloor displacement angle distribution and limit state of the vertex displacement of the frames were analyzed to investigate the seismic responses of the frames. The model analysis results showed that an RC frame with short columns would form a weak layer on the floor where the short columns were located, which greatly weakened the seismic performance of the structure. ECC was certified to be effective in improving the shear formation of the short columns in the frames. The frame with ECC short columns improved the seismic performance of the structure to a certain extent relative to the frame with RC short columns. The deformation capacity of the frame with ECC short columns was close to that of the pure RC frame at the collapse level.
Open AccessSeismic Performance Analysis of RC Frames with ECC Short Columns Based on the IDA Method
Engineered cementitious composite (ECC) is a high-performance composite material with greater shear deformation and shear strength than normal concrete, which has been proposed for use as a shear component in structures. This study modeled three frames, a pure reinforced concrete (RC) frame, an RC frame with concrete short columns and an RC frame with ECC short columns, using the incremental dynamic analysis (IDA) method to evaluate the contribution of ECC to the structural performance. A modified IMK model was applied to model the entire history of the mechanical behaviors of the short columns. The IDA curves, interfloor displacement angle distribution and limit state of the vertex displacement of the frames were analyzed to investigate the seismic responses of the frames. The model analysis results showed that an RC frame with short columns would form a weak layer on the floor where the short columns were located, which greatly weakened the seismic performance of the structure. ECC was certified to be effective in improving the shear formation of the short columns in the frames. The frame with ECC short columns improved the seismic performance of the structure to a certain extent relative to the frame with RC short columns. The deformation capacity of the frame with ECC short columns was close to that of the pure RC frame at the collapse level.
- Open Access
Mechanical Properties of High-Volume Fly Ash Strain Hardening Cementitious Composite (HVFA-SHCC) for Structural Application
Strain-hardening cementitious composite (SHCC) is a kind of construction material that exhibits multiple cracking and strain-hardening behaviors. The partial replacement of cement with fly ash is beneficial to the formation of the tensile strain-hardening property of SHCC, the increase of environmental greenness, and the decrease of hydration heat, as well as the material cost. This study aimed to develop a sustainable construction material using a high dosage of fly ash (no less than 70% of the binder material by weight). Based on the micromechanics analysis and particle size distribution (PSD) optimization, six mixes with different fly ash to cement ratios (2.4–4.4) were designed. The mechanical properties of the developed high-volume fly ash SHCCs (HVFA-SHCCs) were investigated through tensile tests, compressive tests, and flexural tests. Test results showed that all specimens exhibited multiple cracking and strain-hardening behaviors under tension or bending, and the compressive strength of the designed mixes exceeded 30MPa at 28 days, which is suitable for structural applications. Fly ash proved to be beneficial in the improvement of tensile and flexural ductility, but an extremely high volume of fly ash can provide only limited improvement. The HVFA-SHCC mix FA3.2 (with fly ash to binder ratio of about 76% by weight) designed in this study is suggested for structural applications.
Open AccessMechanical Properties of High-Volume Fly Ash Strain Hardening Cementitious Composite (HVFA-SHCC) for Structural Application
Strain-hardening cementitious composite (SHCC) is a kind of construction material that exhibits multiple cracking and strain-hardening behaviors. The partial replacement of cement with fly ash is beneficial to the formation of the tensile strain-hardening property of SHCC, the increase of environmental greenness, and the decrease of hydration heat, as well as the material cost. This study aimed to develop a sustainable construction material using a high dosage of fly ash (no less than 70% of the binder material by weight). Based on the micromechanics analysis and particle size distribution (PSD) optimization, six mixes with different fly ash to cement ratios (2.4–4.4) were designed. The mechanical properties of the developed high-volume fly ash SHCCs (HVFA-SHCCs) were investigated through tensile tests, compressive tests, and flexural tests. Test results showed that all specimens exhibited multiple cracking and strain-hardening behaviors under tension or bending, and the compressive strength of the designed mixes exceeded 30MPa at 28 days, which is suitable for structural applications. Fly ash proved to be beneficial in the improvement of tensile and flexural ductility, but an extremely high volume of fly ash can provide only limited improvement. The HVFA-SHCC mix FA3.2 (with fly ash to binder ratio of about 76% by weight) designed in this study is suggested for structural applications.