Athul Suresh Puthalath
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Athul Suresh Puthalath has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Ramanuj Samanta
Department of Ophthalmology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India
8 shared publications Anupam Singh
Department of Ophthalmology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India
4 shared publicationsSreeram Jayaraj
4 shared publications- Ajai Agrawal
Department of Ophthalmology, All India Institute of Medical Sciences, Rishikesh, India
3 shared publications Mahsa Jamil
Department of Ophthalmology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India
3 shared publicationsKim Ramasamy
Retina Vitreous Services, Aravind Eye Hospitals and Postgraduate Institute of Ophthalmology, Madurai, Tamil Nadu, India
2 shared publications
Latest Publications
- Open Access
- 31 August 2026
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 74 (9) , 1409-1410
ExoMount: Improving reliability of proptosis measurement with a slit-lamp-mounted system
Was not provided for this article.
- 31 August 2026
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 74 (9) , 1409-1410
Open AccessExoMount: Improving reliability of proptosis measurement with a slit-lamp-mounted system
Was not provided for this article.
- 27 August 2026
- Published by BMJ in British Journal of Ophthalmology
Lens attachment guard (LAG): a novel protection system for lenses used in ophthalmology
Background: To create and clinically test the Lens Attachment Guard (LAG), a 3D-printed protective attachment for the prevention of incidental falls and breakage of ophthalmic lenses employed in laser treatments like pan-retinal photocoagulation (PRP). Methods: The LAG system was designed after several cases of lens damage in a busy clinical practice. It was created with Computer-Aided Design software and produced with thermoplastic polyurethane (TPU) through 3D printing. Iterative prototyping was done to maximise fit, optical compatibility and user-friendliness. The last prototype consisted of three primary elements: a winding clip, thread lock and 3D-printed lens holder. Results: The LAG system ensured safe lens stabilisation without compromising laser delivery or visualisation. TPU had shock-absorption and was sterilisation compatible. There were no drops of lenses reported when used. Clinician input revealed enhanced procedural confidence and minimal interference with workflow. The system proved versatile for varied lens types and was readily cleaned and could be reused from case to case. Conclusion: The LAG is a user-friendly, reusable and inexpensive innovation that satisfies a previously unmet need in ophthalmic practice. Its use can have a significant impact on reducing lens damage, increasing procedural safety and increasing clinical efficiency. Multicentre validation and increased lens compatibility testing are ongoing.
- 27 August 2026
- Published by BMJ in British Journal of Ophthalmology
Lens attachment guard (LAG): a novel protection system for lenses used in ophthalmology
Background: To create and clinically test the Lens Attachment Guard (LAG), a 3D-printed protective attachment for the prevention of incidental falls and breakage of ophthalmic lenses employed in laser treatments like pan-retinal photocoagulation (PRP). Methods: The LAG system was designed after several cases of lens damage in a busy clinical practice. It was created with Computer-Aided Design software and produced with thermoplastic polyurethane (TPU) through 3D printing. Iterative prototyping was done to maximise fit, optical compatibility and user-friendliness. The last prototype consisted of three primary elements: a winding clip, thread lock and 3D-printed lens holder. Results: The LAG system ensured safe lens stabilisation without compromising laser delivery or visualisation. TPU had shock-absorption and was sterilisation compatible. There were no drops of lenses reported when used. Clinician input revealed enhanced procedural confidence and minimal interference with workflow. The system proved versatile for varied lens types and was readily cleaned and could be reused from case to case. Conclusion: The LAG is a user-friendly, reusable and inexpensive innovation that satisfies a previously unmet need in ophthalmic practice. Its use can have a significant impact on reducing lens damage, increasing procedural safety and increasing clinical efficiency. Multicentre validation and increased lens compatibility testing are ongoing.
- 3 August 2026
- Published by SAGE Publications in Journal of Vitreoretinal Diseases
Pediatric Endogenous Endophthalmitis: A Decade of Surgical Management and Microbiological Insights
Purpose: To analyze the clinical profile, surgical management, and outcomes of patients with pediatric endogenous endophthalmitis over a decade at a tertiary eye care center in South India. Methods: This retrospective study included 32 eyes of 32 children younger than 15 years. Demographics, systemic illness, microbiological profile, surgical intervention, and outcomes were evaluated. Statistical analysis assessed the relationship between risk factors, complications, and outcomes. Results: The mean age was 7.5 ± 4.4 years; 17 patients were male, and 17 cases involved the right eye. Systemic illness or intravenous therapy preceded infection in 18 patients (56%). In all cases, surgery was performed within 48 hours of presentation. All eyes underwent pars plana vitrectomy with intravitreal antibiotics and intravitreal antifungal agents. Based on intraoperative assessment and the surgeon’s discretion, silicone oil tamponade was used in 16 eyes. Good functional outcomes (best-corrected visual acuity >20/400) occurred in 37.5% of patients, while favorable anatomic outcomes were seen in 46.9%. Median vision improved significantly from hand motions to 20/2400 ( P < .05). Ocular complications were seen in 53.1%, including retinal detachment (7 eyes), secondary glaucoma (2 eyes), and phthisis bulbi (5 eyes), which were significantly associated with poor outcomes ( P < .05). Unique organisms identified included Pantoea agglomerans , Burkholderia cepacia , Rothia dentocariosa , Serratia marcescens , and Alternaria . Conclusions: In this study, pediatric patients with endogenous endophthalmitis had significant visual morbidity despite appropriate surgical intervention. Early vitrectomy aids anatomic recovery, but ocular complications remain the main determinants of unfavorable outcomes.
- 3 August 2026
- Published by SAGE Publications in Journal of Vitreoretinal Diseases
Pediatric Endogenous Endophthalmitis: A Decade of Surgical Management and Microbiological Insights
Purpose: To analyze the clinical profile, surgical management, and outcomes of patients with pediatric endogenous endophthalmitis over a decade at a tertiary eye care center in South India. Methods: This retrospective study included 32 eyes of 32 children younger than 15 years. Demographics, systemic illness, microbiological profile, surgical intervention, and outcomes were evaluated. Statistical analysis assessed the relationship between risk factors, complications, and outcomes. Results: The mean age was 7.5 ± 4.4 years; 17 patients were male, and 17 cases involved the right eye. Systemic illness or intravenous therapy preceded infection in 18 patients (56%). In all cases, surgery was performed within 48 hours of presentation. All eyes underwent pars plana vitrectomy with intravitreal antibiotics and intravitreal antifungal agents. Based on intraoperative assessment and the surgeon’s discretion, silicone oil tamponade was used in 16 eyes. Good functional outcomes (best-corrected visual acuity >20/400) occurred in 37.5% of patients, while favorable anatomic outcomes were seen in 46.9%. Median vision improved significantly from hand motions to 20/2400 ( P < .05). Ocular complications were seen in 53.1%, including retinal detachment (7 eyes), secondary glaucoma (2 eyes), and phthisis bulbi (5 eyes), which were significantly associated with poor outcomes ( P < .05). Unique organisms identified included Pantoea agglomerans , Burkholderia cepacia , Rothia dentocariosa , Serratia marcescens , and Alternaria . Conclusions: In this study, pediatric patients with endogenous endophthalmitis had significant visual morbidity despite appropriate surgical intervention. Early vitrectomy aids anatomic recovery, but ocular complications remain the main determinants of unfavorable outcomes.
- 6 October 2025
- Published by Springer Nature in Eye
- p. 1-2
A paediatric case of Nance–Horan Syndrome
- Open Access
- 25 September 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (10) , 1530-1532
ASTRA 90 – Aravind slit lamp and training retinal assessment tool
Slit-lamp biomicroscopy using a 90-diopter (90D) lens is a standard technique employed by ophthalmologists for detailed evaluation of the posterior segment. However, this skill has a steep learning curve, and it takes time before the clinician gets hold of it, especially in the initial days of residency. In a country like India, characterized by a substantial patient burden and extended waiting times where the healthcare system faces considerable strain, we created a learning tool for new residents to learn fundus examination on slit lamp with 90D lens. We developed a 3D-printed eyeball which is optically similar to the human eye and aids students in grasping this skill at a faster rate. This model is incorporated by a retina film which can be changed, and a beginner in ophthalmology can view both normal and pathological fundi. It enables trainees to simulate the optical and procedural aspects of performing a 90D fundus examination in a controlled, risk-free environment.
- 25 September 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (10) , 1530-1532
Open AccessASTRA 90 – Aravind slit lamp and training retinal assessment tool
Slit-lamp biomicroscopy using a 90-diopter (90D) lens is a standard technique employed by ophthalmologists for detailed evaluation of the posterior segment. However, this skill has a steep learning curve, and it takes time before the clinician gets hold of it, especially in the initial days of residency. In a country like India, characterized by a substantial patient burden and extended waiting times where the healthcare system faces considerable strain, we created a learning tool for new residents to learn fundus examination on slit lamp with 90D lens. We developed a 3D-printed eyeball which is optically similar to the human eye and aids students in grasping this skill at a faster rate. This model is incorporated by a retina film which can be changed, and a beginner in ophthalmology can view both normal and pathological fundi. It enables trainees to simulate the optical and procedural aspects of performing a 90D fundus examination in a controlled, risk-free environment.
- Open Access
- 16 January 2024
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 4 (1) , 108-110
Ixodes tick infestation presenting as preseptal cellulitis: A rare occurrence
Herein, we report a case of preseptal cellulitis due to an Ixodes tick infestation, which was subsequently treated by mechanical removal and antibiotics. A 50-year-old man presented to the ophthalmology clinic with gradually increasing swelling of both upper and lower lids of his right eye with associated watering. He was diagnosed with unilateral preseptal cellulitis with a grayish nodule near the lower eyelid, which was found to be a hard tick of the Ixodes genus. Complete removal of the tick with the help of a blunt forceps under local anesthetic cover was performed. A prophylactic course of oral antibiotics was also prescribed to the patient. After a period of 1 week, all his symptoms had subsided without any systemic manifestations. Ticks are acarine ectoparasitic hematophagies, many species of which have been recognized as vectors of lethal pathogens. Tick infestation of the ocular tissue is a rare occurrence. Complete removal of the tick parts is pertinent to prevent the late sequelae and serious complications. This case report suggests that clinicians should be aware about tick bite–related sequelae, such as preseptal cellulitis and other complications, to reach an early diagnosis.
- 16 January 2024
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 4 (1) , 108-110
Open AccessIxodes tick infestation presenting as preseptal cellulitis: A rare occurrence
Herein, we report a case of preseptal cellulitis due to an Ixodes tick infestation, which was subsequently treated by mechanical removal and antibiotics. A 50-year-old man presented to the ophthalmology clinic with gradually increasing swelling of both upper and lower lids of his right eye with associated watering. He was diagnosed with unilateral preseptal cellulitis with a grayish nodule near the lower eyelid, which was found to be a hard tick of the Ixodes genus. Complete removal of the tick with the help of a blunt forceps under local anesthetic cover was performed. A prophylactic course of oral antibiotics was also prescribed to the patient. After a period of 1 week, all his symptoms had subsided without any systemic manifestations. Ticks are acarine ectoparasitic hematophagies, many species of which have been recognized as vectors of lethal pathogens. Tick infestation of the ocular tissue is a rare occurrence. Complete removal of the tick parts is pertinent to prevent the late sequelae and serious complications. This case report suggests that clinicians should be aware about tick bite–related sequelae, such as preseptal cellulitis and other complications, to reach an early diagnosis.
- Open Access
- 1 April 2023
- Published by Medknow in Indian Journal of Ophthalmology - Case Reports
- Vol. 3 (2) , 551-552
Sutural cataract in neurofibromatosis type 1
- 1 April 2023
- Published by Medknow in Indian Journal of Ophthalmology - Case Reports
- Vol. 3 (2) , 551-552
Open AccessSutural cataract in neurofibromatosis type 1
- 11 November 2022
- Published by BMJ in BMJ Case Reports
- Vol. 15 (11) , e249327
Paracentral acute middle maculopathy with occlusive retinal vasculitis in presumed intraocular tuberculosis and hyperhomocysteinemia
A male patient presented with a sudden visual decline in the right eye (OD). Fundus revealed bilateral vasculitis; OD also showed an occluded inferior retinal vein and a wedge-shaped retinal opacification of the inferior macula and nasal retina. Fluorescein angiography revealed occlusive retinal vasculitis, while optical coherence tomography showed paracentral acute middle maculopathy (PAMM) in the OD. A thorough systemic evaluation revealed hyperhomocysteinemia and a positive Mantoux test. A diagnosis of PAMM with occlusive retinal vasculitis in presumed intraocular tuberculosis and hyperhomocysteinemia was made. Retinal vasculitis improved with oral corticosteroid, intravitreal anti-vascular endothelial growth factor and laser photocoagulation. However, the patient declined antitubercular therapy despite recommendations. This unique report indicates that PAMM may complicate tubercular retinal vasculitis, especially in the presence of systemic hypercoagulable states.
- 11 November 2022
- Published by BMJ in BMJ Case Reports
- Vol. 15 (11) , e249327
Paracentral acute middle maculopathy with occlusive retinal vasculitis in presumed intraocular tuberculosis and hyperhomocysteinemia
A male patient presented with a sudden visual decline in the right eye (OD). Fundus revealed bilateral vasculitis; OD also showed an occluded inferior retinal vein and a wedge-shaped retinal opacification of the inferior macula and nasal retina. Fluorescein angiography revealed occlusive retinal vasculitis, while optical coherence tomography showed paracentral acute middle maculopathy (PAMM) in the OD. A thorough systemic evaluation revealed hyperhomocysteinemia and a positive Mantoux test. A diagnosis of PAMM with occlusive retinal vasculitis in presumed intraocular tuberculosis and hyperhomocysteinemia was made. Retinal vasculitis improved with oral corticosteroid, intravitreal anti-vascular endothelial growth factor and laser photocoagulation. However, the patient declined antitubercular therapy despite recommendations. This unique report indicates that PAMM may complicate tubercular retinal vasculitis, especially in the presence of systemic hypercoagulable states.
- Open Access
- 28 April 2022
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 70 (5) , 1727-1731
Alteration in pattern reversal visual evoked potential in pediatric population with amblyopia and spherical refractive errors
Purpose: To study the effect of refractive errors on pattern visual evoked potential (VEP) recordings in the pediatric population. Methods: This cross-sectional observational study assessed 240 eyes of 120 participants attending the outpatient department of a tertiary care center in North India. Participants were between 8 and 18 years of age; 30 participants each were recruited into four groups, namely emmetropia, myopia, hypermetropia, and amblyopia. They were then subjected to pattern reversal VEP, with P-100 amplitude and latency recorded for each participant. Results: The emmetropic group in this study provided normal values of P-100 parameters, namely P-100 latency and P-100 amplitude with readings of 115.78 ± 10.19 ms and 11.11 ± 4.08 mV, respectively. P-100 amplitude was significant compared to P-100 latency in detecting the presence or absence of a specific type of refractive error. It was found that there was a significant association between severity of myopia and P-100 latency (both unaided and aided) with P < 0.05. The severity of hypermetropia showed a significant association with P-100 amplitude (unaided) (P < 0.05). Receiver operating characteristics analysis revealed P-100 amplitude to be a good predictor of refractive error and the cut-offs were calculated. Conclusion: The P-100 parameters of the pediatric Indian population were comparatively higher than conventional values. P-100 latency seemed to better correlate with myopia, while hypermetropia correlated with P-100 amplitude. P-100 amplitude appears to be the most significant predictor of the presence of refractive error in an individual.
- 28 April 2022
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 70 (5) , 1727-1731
Open AccessAlteration in pattern reversal visual evoked potential in pediatric population with amblyopia and spherical refractive errors
Purpose: To study the effect of refractive errors on pattern visual evoked potential (VEP) recordings in the pediatric population. Methods: This cross-sectional observational study assessed 240 eyes of 120 participants attending the outpatient department of a tertiary care center in North India. Participants were between 8 and 18 years of age; 30 participants each were recruited into four groups, namely emmetropia, myopia, hypermetropia, and amblyopia. They were then subjected to pattern reversal VEP, with P-100 amplitude and latency recorded for each participant. Results: The emmetropic group in this study provided normal values of P-100 parameters, namely P-100 latency and P-100 amplitude with readings of 115.78 ± 10.19 ms and 11.11 ± 4.08 mV, respectively. P-100 amplitude was significant compared to P-100 latency in detecting the presence or absence of a specific type of refractive error. It was found that there was a significant association between severity of myopia and P-100 latency (both unaided and aided) with P < 0.05. The severity of hypermetropia showed a significant association with P-100 amplitude (unaided) (P < 0.05). Receiver operating characteristics analysis revealed P-100 amplitude to be a good predictor of refractive error and the cut-offs were calculated. Conclusion: The P-100 parameters of the pediatric Indian population were comparatively higher than conventional values. P-100 latency seemed to better correlate with myopia, while hypermetropia correlated with P-100 amplitude. P-100 amplitude appears to be the most significant predictor of the presence of refractive error in an individual.
- Open Access
- 24 February 2022
- Published by BMJ in BMJ Case Reports
- Vol. 15 (2) , e246243
Undiagnosed malignant hypertension presenting as a direct spontaneous carotid-cavernous fistula with complete loss of vision and hyphaema
- 24 February 2022
- Published by BMJ in BMJ Case Reports
- Vol. 15 (2) , e246243
Open AccessUndiagnosed malignant hypertension presenting as a direct spontaneous carotid-cavernous fistula with complete loss of vision and hyphaema