Alex Walsh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alex Walsh has a total of 259 co-authors. Here are the top co-authors by number of shared publications:
- Melissa C. Skala
Department of Biomedical Engineering, University of Wisconsin, Madison, USA
16 shared publications Linghao Hu
Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77840, USA
11 shared publications- Melissa C. Skala
Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA
10 shared publications Rebecca S. Cook
Vanderbilt University
7 shared publicationsCarlos L. Arteaga
Department of Cancer Biology, Vanderbilt University, 2220 Pierce Avenue, Nashville, Tennessee, USA
6 shared publicationsNianchao Wang
Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States
6 shared publications
Latest Publications
- 2 October 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (11) , 5410
Protocol optimization for in vitro infrared modulation studies
Modulation of neurons with infrared light provides a non-contact, non-genetic method to modulate neural activity. However, the laser parameters that induce activity vary widely within the literature, hindering the adoption and replication of infrared neuromodulation studies. Therefore, this work presents a pipeline to optimize infrared laser parameters for modulation by quantifying radiant exposures, estimating temperature changes at the sample plane, and defining radiant exposures that avoid acute cellular damage. SH-SY5Y cells, mixed glial cells, and neuron responses were verified via calcium imaging. Radiant exposures from a 1470 nm laser diode were calculated for a single 4 ms pulse from a 200 μm fiber using the power output, pulse duration, and illumination spot size. Eu-TTA, a thermosensitive fluorescent dye, was used to quantify temperature changes induced by the IR pulse at the sample plane. Damage assessments were performed on SH-SY5Y cells, mixed glial cells, and primary hippocampal neurons using YO-PRO-1 (a fluorescent dye). Modulation with pulsed infrared light was confirmed with the induction of intracellular calcium using Oregon Green BAPTA-1. SH-SY5Y cells, mixed glial cells, and neurons exhibited a high uptake or a complete loss of YO-PRO-1 fluorescence with 0.65 J/cm 2 , 4 ms 1470 nm exposure due to cell damage or ablation, respectively. A radiant exposure of 0.61 J/cm 2 at 1470 nm with a 4 ms IR pulse, which did not induce acute cellular damage, induced calcium activity in SH-SY5Y cells, mixed glial cells, and neurons. This work establishes a framework for quantifying essential IR laser parameters and IR-induced temperature changes for infrared neuromodulation.
- 2 October 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (11) , 5410
Protocol optimization for in vitro infrared modulation studies
Modulation of neurons with infrared light provides a non-contact, non-genetic method to modulate neural activity. However, the laser parameters that induce activity vary widely within the literature, hindering the adoption and replication of infrared neuromodulation studies. Therefore, this work presents a pipeline to optimize infrared laser parameters for modulation by quantifying radiant exposures, estimating temperature changes at the sample plane, and defining radiant exposures that avoid acute cellular damage. SH-SY5Y cells, mixed glial cells, and neuron responses were verified via calcium imaging. Radiant exposures from a 1470 nm laser diode were calculated for a single 4 ms pulse from a 200 μm fiber using the power output, pulse duration, and illumination spot size. Eu-TTA, a thermosensitive fluorescent dye, was used to quantify temperature changes induced by the IR pulse at the sample plane. Damage assessments were performed on SH-SY5Y cells, mixed glial cells, and primary hippocampal neurons using YO-PRO-1 (a fluorescent dye). Modulation with pulsed infrared light was confirmed with the induction of intracellular calcium using Oregon Green BAPTA-1. SH-SY5Y cells, mixed glial cells, and neurons exhibited a high uptake or a complete loss of YO-PRO-1 fluorescence with 0.65 J/cm 2 , 4 ms 1470 nm exposure due to cell damage or ablation, respectively. A radiant exposure of 0.61 J/cm 2 at 1470 nm with a 4 ms IR pulse, which did not induce acute cellular damage, induced calcium activity in SH-SY5Y cells, mixed glial cells, and neurons. This work establishes a framework for quantifying essential IR laser parameters and IR-induced temperature changes for infrared neuromodulation.
- Open Access
- 1 October 2026
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 3 (04) , 1-15
Improving bi-exponential fitting of autofluorescence lifetime decay data through whole-cell binning
SignificanceFluorescence lifetime imaging (FLIM) analysis commonly involves multi-exponential fitting of fluorescence decays, which requires relatively high signal-to-noise ratios (SNRs). However, autofluorescence presents a weaker signal compared with exogenous fluorophores, which can make fitting challenging. Becker & Hickl’s SPCImage (SPCI) is commonly used for bi-exponential fitting of NAD(P)H autofluorescence decays, but its accuracy has not been robustly evaluated.AimWe evaluate the accuracy of bi-exponential modeling of NAD(P)H FLIM data from live cells and provide an alternative fitting algorithm that allows for photon binning of whole cells for low SNR applications.ApproachSimulated fluorescence lifetime decay data and NADH solutions were used to test the accuracy of fitting in both SPCI and a custom-written MATLAB algorithm. FLIM images collected from live cells using varying integration times were also evaluated.ResultsResults show consistently higher error for SPCI in fluorescence decay parameters compared with the custom-written MATLAB algorithm. Whole-cell binning greatly improved the accuracy of all lifetime decay parameters, allowing for shorter integration times during acquisition.ConclusionsOur custom-written MATLAB algorithm can provide a flexible alternative fitting tool that allows for photon binning of whole cells and substantially more accurate parameter estimation.
- 1 October 2026
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 3 (04) , 1-15
Open AccessImproving bi-exponential fitting of autofluorescence lifetime decay data through whole-cell binning
SignificanceFluorescence lifetime imaging (FLIM) analysis commonly involves multi-exponential fitting of fluorescence decays, which requires relatively high signal-to-noise ratios (SNRs). However, autofluorescence presents a weaker signal compared with exogenous fluorophores, which can make fitting challenging. Becker & Hickl’s SPCImage (SPCI) is commonly used for bi-exponential fitting of NAD(P)H autofluorescence decays, but its accuracy has not been robustly evaluated.AimWe evaluate the accuracy of bi-exponential modeling of NAD(P)H FLIM data from live cells and provide an alternative fitting algorithm that allows for photon binning of whole cells for low SNR applications.ApproachSimulated fluorescence lifetime decay data and NADH solutions were used to test the accuracy of fitting in both SPCI and a custom-written MATLAB algorithm. FLIM images collected from live cells using varying integration times were also evaluated.ResultsResults show consistently higher error for SPCI in fluorescence decay parameters compared with the custom-written MATLAB algorithm. Whole-cell binning greatly improved the accuracy of all lifetime decay parameters, allowing for shorter integration times during acquisition.ConclusionsOur custom-written MATLAB algorithm can provide a flexible alternative fitting tool that allows for photon binning of whole cells and substantially more accurate parameter estimation.
- Open Access
- 1 September 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (09) , 1-15
Python-controlled multimodal UV-VIS hyperspectral imaging system
SignificanceTraumatic and chronic wound healing is a complex process that often requires careful observation by healthcare professionals. Noninvasive optical technologies such as hyperspectral reflectance imaging and tissue autofluorescence imaging detect changes in optical properties related to physiological parameters such as tissue perfusion. Macroscopic hyperspectral systems with a large field of view to visualize tissue structure and perfusion are well suited for wound care.AimHere, a custom-built benchtop hyperspectral and autofluorescence imaging system (HySAF) is optimized to measure tissue optical properties. It operates using a custom Python script to allow precise control over acquisition parameters.ApproachHySAF was built using off-the-shelf components, and Python code was written to control primary devices. HySAF’s performance was evaluated by imaging oxygenated and deoxygenated blood samples, scattering induced by nanoparticles, scorpion autofluorescence, and rat wounds.ResultsHySAF has a large field of view (FOV) with 176.7 μm pixel resolution and 10 nm spectral resolution from 420 to 730 nm. Changes in absorbance were observed during blood deoxygenation, nanoparticle presence in cells, and healing wound tissue in rats, while autofluorescence distinguished anatomical parts of the scorpion.ConclusionHySAF is capable of detecting changes in sample fluorescence and absorbance across visible light with large FOV and could be implemented in clinical applications such as monitoring and assessing wound healing.
- 1 September 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (09) , 1-15
Open AccessPython-controlled multimodal UV-VIS hyperspectral imaging system
SignificanceTraumatic and chronic wound healing is a complex process that often requires careful observation by healthcare professionals. Noninvasive optical technologies such as hyperspectral reflectance imaging and tissue autofluorescence imaging detect changes in optical properties related to physiological parameters such as tissue perfusion. Macroscopic hyperspectral systems with a large field of view to visualize tissue structure and perfusion are well suited for wound care.AimHere, a custom-built benchtop hyperspectral and autofluorescence imaging system (HySAF) is optimized to measure tissue optical properties. It operates using a custom Python script to allow precise control over acquisition parameters.ApproachHySAF was built using off-the-shelf components, and Python code was written to control primary devices. HySAF’s performance was evaluated by imaging oxygenated and deoxygenated blood samples, scattering induced by nanoparticles, scorpion autofluorescence, and rat wounds.ResultsHySAF has a large field of view (FOV) with 176.7 μm pixel resolution and 10 nm spectral resolution from 420 to 730 nm. Changes in absorbance were observed during blood deoxygenation, nanoparticle presence in cells, and healing wound tissue in rats, while autofluorescence distinguished anatomical parts of the scorpion.ConclusionHySAF is capable of detecting changes in sample fluorescence and absorbance across visible light with large FOV and could be implemented in clinical applications such as monitoring and assessing wound healing.
- Open Access
- 18 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (25) , 19271-19282
Mapping Morphology-Dependent Stability of Gold Nanostars in Immune Cells Using Hyperspectral Imaging
Gold nanoparticles (AuNPs) are widely applied in nanomedicine, cellular and tissue biology, nanoscopy, photothermal therapy, and a range of diagnostic and clinical technologies. Among them, gold nanostars (AuNSs) have emerged as particularly promising due to their highly tunable optical and chemical properties. However, like other nanostructures, the stability of AuNSs remains a key challenge, especially within complex cellular microenvironments. Here, wide-field hyperspectral microscopy is evaluated for the real-time characterization of the morphology-dependent stability of AuNS formulations in immune-cell microenvironments. A computationally efficient image processing pipeline extracts statistical features from reflectance images, enabling the real-time analysis of hyperspectral data. UMAP-based visualization of spectral data revealed distinct, time- and formulation-dependent spectral shifts, with smaller seed volume formulations (larger overall diameter) for AuNSs exhibiting rapid destabilization and aggregation in THP-1 cells. In contrast, larger seed volume formulations (smaller overall diameter) for AuNS demonstrated enhanced colloidal stability and spectral uniformity. Compared to conventional ensemble measurements, hyperspectral reflectance measurements provided a rapid and resource-efficient approach that enabled macroscale imaging while retaining the spectral detail necessary to resolve AuNS transformations. Overall, the hyperspectral microscopy techniques presented here provide a label-free, high-throughput platform for evaluating AuNS stability and biocompatibility, with strong potential to guide the rational design of AuNSs for immunotherapeutic and diagnostic applications.
- 18 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (25) , 19271-19282
Open AccessMapping Morphology-Dependent Stability of Gold Nanostars in Immune Cells Using Hyperspectral Imaging
Gold nanoparticles (AuNPs) are widely applied in nanomedicine, cellular and tissue biology, nanoscopy, photothermal therapy, and a range of diagnostic and clinical technologies. Among them, gold nanostars (AuNSs) have emerged as particularly promising due to their highly tunable optical and chemical properties. However, like other nanostructures, the stability of AuNSs remains a key challenge, especially within complex cellular microenvironments. Here, wide-field hyperspectral microscopy is evaluated for the real-time characterization of the morphology-dependent stability of AuNS formulations in immune-cell microenvironments. A computationally efficient image processing pipeline extracts statistical features from reflectance images, enabling the real-time analysis of hyperspectral data. UMAP-based visualization of spectral data revealed distinct, time- and formulation-dependent spectral shifts, with smaller seed volume formulations (larger overall diameter) for AuNSs exhibiting rapid destabilization and aggregation in THP-1 cells. In contrast, larger seed volume formulations (smaller overall diameter) for AuNS demonstrated enhanced colloidal stability and spectral uniformity. Compared to conventional ensemble measurements, hyperspectral reflectance measurements provided a rapid and resource-efficient approach that enabled macroscale imaging while retaining the spectral detail necessary to resolve AuNS transformations. Overall, the hyperspectral microscopy techniques presented here provide a label-free, high-throughput platform for evaluating AuNS stability and biocompatibility, with strong potential to guide the rational design of AuNSs for immunotherapeutic and diagnostic applications.
- 18 June 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (7) , 3776-3791
FLIM quantification of temperature-dependent enzyme-NADH binding dynamics
Metabolic enzyme-coenzyme interactions are temperature-dependent; yet, conventional biochemical assays lack the temporal and spatial resolution to resolve rapid thermal effects on cellular metabolism and cellular binding equilibria. Here, fluorescence lifetime imaging microscopy (FLIM) of the metabolic coenzyme nicotinamide adenine dinucleotide (NADH) was used to quantify steady-state and rapid temperature-dependent changes in enzyme-coenzyme binding dynamics through estimation of dissociation constants ( K D ) and corresponding fractions of free NADH ( α 1 ). A computational model describing the temperature dependence of enzyme-coenzyme binding affinity was constructed to relate changes in K D to temperature-dependent shifts in α 1 . This model was validated in LDH-NADH solutions, MCF-7 cells, and primary murine hippocampal neurons using FLIM. Both steady-state and rapid temperature increases induced increases in free NAD(P)H across all samples, consistent with a reduction in binding affinity (increased K D ). Rapid thermal gradients induced by short pulses of infrared light produced greater increases in free NADH in LDH-NADH solutions than in cells. These results establish FLIM of NADH as a non-contact, quantitative method to evaluate the temperature-dependence of enzyme-coenzyme binding at millisecond timescales. Additionally, integration of temperature-dependent dissociation constant modeling with FLIM provides a generalizable framework for studying dynamic enzymatic binding processes within living cells that are otherwise inaccessible using conventional assays.
- 18 June 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (7) , 3776-3791
FLIM quantification of temperature-dependent enzyme-NADH binding dynamics
Metabolic enzyme-coenzyme interactions are temperature-dependent; yet, conventional biochemical assays lack the temporal and spatial resolution to resolve rapid thermal effects on cellular metabolism and cellular binding equilibria. Here, fluorescence lifetime imaging microscopy (FLIM) of the metabolic coenzyme nicotinamide adenine dinucleotide (NADH) was used to quantify steady-state and rapid temperature-dependent changes in enzyme-coenzyme binding dynamics through estimation of dissociation constants ( K D ) and corresponding fractions of free NADH ( α 1 ). A computational model describing the temperature dependence of enzyme-coenzyme binding affinity was constructed to relate changes in K D to temperature-dependent shifts in α 1 . This model was validated in LDH-NADH solutions, MCF-7 cells, and primary murine hippocampal neurons using FLIM. Both steady-state and rapid temperature increases induced increases in free NAD(P)H across all samples, consistent with a reduction in binding affinity (increased K D ). Rapid thermal gradients induced by short pulses of infrared light produced greater increases in free NADH in LDH-NADH solutions than in cells. These results establish FLIM of NADH as a non-contact, quantitative method to evaluate the temperature-dependence of enzyme-coenzyme binding at millisecond timescales. Additionally, integration of temperature-dependent dissociation constant modeling with FLIM provides a generalizable framework for studying dynamic enzymatic binding processes within living cells that are otherwise inaccessible using conventional assays.
- Open Access
- 15 June 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (3) , 036001
FLIMExplorer: Interactive GUI for object-based visualization and analysis of fluorescence lifetime images
Fluorescence lifetime imaging microscopy (FLIM) enables non-invasive measurement of cellular metabolism with single-cell and subcellular resolution, providing advantages over traditional population-level metabolic assays. However, current single-cell FLIM analysis workflows typically rely on multiple software tools for lifetime extraction, segmentation, and downstream analysis, often resulting in convoluted workflows and a disconnect between quantitative measurements and image context, limiting transparent quality control. Here, we present FLIMExplorer, an interactive, Python-based tool for downstream single-cell FLIM analysis and visualization. FLIMExplorer links quantitative FLIM endpoints and their underlying image objects, enabling users to explore key FLIM features (NAD(P)H and FAD τₘ, τ₁, τ₂, and α₁) at the single-cell level, visualize image objects corresponding to individual data points, and perform statistical comparisons across experimental groups within a single graphic user interface app. FLIMExplorer handles inputs of both 1) pixel-level FLIM outputs generated by upstream fitting software and 2) pre-processed, cell-average FLIM datasets. By integrating visualization, quality control, and statistical analysis at the single-cell level within a single platform, FLIMExplorer improves the integration of quantitative results with image context in downstream FLIM analysis.
- 15 June 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (3) , 036001
Open AccessFLIMExplorer: Interactive GUI for object-based visualization and analysis of fluorescence lifetime images
Fluorescence lifetime imaging microscopy (FLIM) enables non-invasive measurement of cellular metabolism with single-cell and subcellular resolution, providing advantages over traditional population-level metabolic assays. However, current single-cell FLIM analysis workflows typically rely on multiple software tools for lifetime extraction, segmentation, and downstream analysis, often resulting in convoluted workflows and a disconnect between quantitative measurements and image context, limiting transparent quality control. Here, we present FLIMExplorer, an interactive, Python-based tool for downstream single-cell FLIM analysis and visualization. FLIMExplorer links quantitative FLIM endpoints and their underlying image objects, enabling users to explore key FLIM features (NAD(P)H and FAD τₘ, τ₁, τ₂, and α₁) at the single-cell level, visualize image objects corresponding to individual data points, and perform statistical comparisons across experimental groups within a single graphic user interface app. FLIMExplorer handles inputs of both 1) pixel-level FLIM outputs generated by upstream fitting software and 2) pre-processed, cell-average FLIM datasets. By integrating visualization, quality control, and statistical analysis at the single-cell level within a single platform, FLIMExplorer improves the integration of quantitative results with image context in downstream FLIM analysis.
- Open Access
- 4 November 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1) , 015001
Low-cost luminescence lifetime system for medical diagnostics
Luminescence lifetimes provide insights into the local microenvironment of luminescent molecules, enabling precise measurements that can be leveraged for biomedical imaging and sensing applications. Traditional systems for measuring luminescence lifetimes rely on expensive ultrafast detectors and electronics. Here, a novel optical luminescence lifetime estimation method, modular analysis and eXtraction system for affordable lifetime imaging of fluorescence signals (MAX-alif), was developed to provide a high-speed, low-cost, and scalable solution for luminescence lifetime measurements. In MAX-alif, excitation light with sinusoidal intensity modulation is combined with synthetic path-length difference analysis and machine learning regression to compute luminescence lifetimes from intensity image features. An acousto-optical modulator within the detection path transfers the synthesized phase difference between the excitation and emission light into intensity differences that a standard camera can capture. Both simulation and experimental data were used to generate and validate models for the calibration and extraction of lifetime values from intensity datasets. MAX-alif measurements of phosphorescent and fluorescent samples achieved mean and median lifetime values within 5% of the reference lifetime values. By eliminating the need for expensive hardware and enabling accurate lifetime imaging with standard cameras, MAX-alif allows widespread, cost-effective luminescence lifetime imaging for medical diagnostics applications.
- 4 November 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1) , 015001
Open AccessLow-cost luminescence lifetime system for medical diagnostics
Luminescence lifetimes provide insights into the local microenvironment of luminescent molecules, enabling precise measurements that can be leveraged for biomedical imaging and sensing applications. Traditional systems for measuring luminescence lifetimes rely on expensive ultrafast detectors and electronics. Here, a novel optical luminescence lifetime estimation method, modular analysis and eXtraction system for affordable lifetime imaging of fluorescence signals (MAX-alif), was developed to provide a high-speed, low-cost, and scalable solution for luminescence lifetime measurements. In MAX-alif, excitation light with sinusoidal intensity modulation is combined with synthetic path-length difference analysis and machine learning regression to compute luminescence lifetimes from intensity image features. An acousto-optical modulator within the detection path transfers the synthesized phase difference between the excitation and emission light into intensity differences that a standard camera can capture. Both simulation and experimental data were used to generate and validate models for the calibration and extraction of lifetime values from intensity datasets. MAX-alif measurements of phosphorescent and fluorescent samples achieved mean and median lifetime values within 5% of the reference lifetime values. By eliminating the need for expensive hardware and enabling accurate lifetime imaging with standard cameras, MAX-alif allows widespread, cost-effective luminescence lifetime imaging for medical diagnostics applications.
- 20 October 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (11) , 4470-4482
Fluorescence lifetime imaging to investigate propofol-induced metabolic alterations in MDA-MB-231 cells
The metabolic effects of anesthetic agents like propofol on cancer cells remain poorly understood despite the widespread use of anesthesia during cancer diagnosis and treatment. Fluorescence lifetime imaging microscopy (FLIM) was used to analyze propofol-induced metabolic changes in triple-negative breast cancer cells (MDA-MB-231) by monitoring endogenous NAD(P)H and FAD fluorescence lifetimes. FLIM of propofol-treated MDA-MB-231 cells revealed concentration-dependent shifts in metabolic states that were supported by Seahorse extracellular flux analysis. While the flux analysis provided population-averaged metabolic data, FLIM enabled high-resolution, dynamic mapping of metabolism in live cancer cells. Our study highlights FLIM as a label-free tool for investigating anesthetic-induced metabolic alterations in cells, offering insights into the potential metabolic mechanisms of propofol.
- 20 October 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (11) , 4470-4482
Fluorescence lifetime imaging to investigate propofol-induced metabolic alterations in MDA-MB-231 cells
The metabolic effects of anesthetic agents like propofol on cancer cells remain poorly understood despite the widespread use of anesthesia during cancer diagnosis and treatment. Fluorescence lifetime imaging microscopy (FLIM) was used to analyze propofol-induced metabolic changes in triple-negative breast cancer cells (MDA-MB-231) by monitoring endogenous NAD(P)H and FAD fluorescence lifetimes. FLIM of propofol-treated MDA-MB-231 cells revealed concentration-dependent shifts in metabolic states that were supported by Seahorse extracellular flux analysis. While the flux analysis provided population-averaged metabolic data, FLIM enabled high-resolution, dynamic mapping of metabolism in live cancer cells. Our study highlights FLIM as a label-free tool for investigating anesthetic-induced metabolic alterations in cells, offering insights into the potential metabolic mechanisms of propofol.
- Open Access
- 13 August 2025
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
Seeing deep to map cell–biomaterial interactions via whole mount light sheet imaging and automated analytics in decellularized extracellular matrix models
An optical clearing, light sheet microscopy and analysis pipeline was created for decellularized ECM (dECM)-based in vitro models. Our approach quantifies cell invasion in colorectal cancer liver metastasis (CRLM) models engineered with dECM.
- 13 August 2025
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
Open AccessSeeing deep to map cell–biomaterial interactions via whole mount light sheet imaging and automated analytics in decellularized extracellular matrix models
An optical clearing, light sheet microscopy and analysis pipeline was created for decellularized ECM (dECM)-based in vitro models. Our approach quantifies cell invasion in colorectal cancer liver metastasis (CRLM) models engineered with dECM.
- Top Cited PapersOpen Access
- 1 February 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (S2) , 1-22
Consensus guidelines for cellular label-free optical metabolic imaging: ensuring accuracy and reproducibility in metabolic profiling
SignificanceCellular metabolism plays a central role in health and disease, making its study critical for advancing diagnostics and therapies. Label-free optical metabolic imaging using endogenous fluorescence from reduced nicotinamide adenine dinucleotide (phosphate) [NAD(P)H] and flavin adenine dinucleotide (FAD) provides nondestructive, high-resolution insights into metabolic function and heterogeneity from the sub-cellular to the tissue level. Standardized approaches are essential to ensure reproducibility and comparability across studies.AimWe aim to establish a consensus framework for the acquisition, calibration, and reporting of microscopic imaging metabolic function assessments based on fluorescence intensity and lifetime measurements of NAD(P)H and FAD.ApproachWe present best practices for calibrating, analyzing, and reporting fluorescence intensity-based optical redox ratios and fluorescence lifetime data using multiexponential fitting and phasor analysis. Guidelines for validation experiments and cross-system standardization are provided to improve accuracy and reproducibility.ResultsWe demonstrate the importance of calibration procedures and normalization strategies for intensity-based optical redox measurements. We highlight needed calibration, signal-to-noise ratio considerations, and the impact of distinct analytical approaches on fluorescence lifetime-based metabolic function metrics.ConclusionWe recommend a consistent, practical framework for reproducible, label-free, optical metabolic imaging, facilitating robust comparisons across studies and supporting the broader adoption of optical metabolic imaging technologies for biomedical research and clinical translation.
- 1 February 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (S2) , 1-22
Top Cited PapersOpen AccessConsensus guidelines for cellular label-free optical metabolic imaging: ensuring accuracy and reproducibility in metabolic profiling
SignificanceCellular metabolism plays a central role in health and disease, making its study critical for advancing diagnostics and therapies. Label-free optical metabolic imaging using endogenous fluorescence from reduced nicotinamide adenine dinucleotide (phosphate) [NAD(P)H] and flavin adenine dinucleotide (FAD) provides nondestructive, high-resolution insights into metabolic function and heterogeneity from the sub-cellular to the tissue level. Standardized approaches are essential to ensure reproducibility and comparability across studies.AimWe aim to establish a consensus framework for the acquisition, calibration, and reporting of microscopic imaging metabolic function assessments based on fluorescence intensity and lifetime measurements of NAD(P)H and FAD.ApproachWe present best practices for calibrating, analyzing, and reporting fluorescence intensity-based optical redox ratios and fluorescence lifetime data using multiexponential fitting and phasor analysis. Guidelines for validation experiments and cross-system standardization are provided to improve accuracy and reproducibility.ResultsWe demonstrate the importance of calibration procedures and normalization strategies for intensity-based optical redox measurements. We highlight needed calibration, signal-to-noise ratio considerations, and the impact of distinct analytical approaches on fluorescence lifetime-based metabolic function metrics.ConclusionWe recommend a consistent, practical framework for reproducible, label-free, optical metabolic imaging, facilitating robust comparisons across studies and supporting the broader adoption of optical metabolic imaging technologies for biomedical research and clinical translation.