Ioannis Vourganas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ioannis Vourganas has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Anna Lito Michala
University of Glasgow
5 shared publications - Hani Attar
Faculty of Engineering, Zarqa University, Zarqa, Jordan
3 shared publications - Lina Stankovic
Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow G1 1XW, UK
3 shared publications - Vladimir Stankovic
University of Strathclyde
3 shared publications - Ahmed Amin Ahmed Solyman
Department of Electrical and Electronics Engineering, Faculty of Engineering and Architecture, Nişantaşı University, Istanbul, Turkey
1 shared publication - Andrea Coraddu
Department of Maritime and Transport Technology, Delft University of Technology, Delft, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 17 November 2024
- Published by MDPI AG in Journal of Cybersecurity and Privacy
- Vol. 4 (4) , 972-992
Applications of Machine Learning in Cyber Security: A Review
In recent years, Machine Learning (ML) and Artificial Intelligence (AI) have been gaining ground in Cyber Security (CS) research in an attempt to counter increasingly sophisticated attacks. However, this paper poses the question of qualitative and quantitative data. This paper argues that scholarly research in this domain is severely impacted by the quality and quantity of available data. Datasets are disparate. There is no uniformity in (i) the dataset features, (ii) the methods of collection, or (iii) the preprocessing requirements to enable good-quality analyzed data that are suitable for automated decision-making. This review contributes to the existing literature by providing a single summary of the wider field in relation to AI, evaluating the most recent datasets, combining considerations of ethical AI, and posing a list of open research questions to guide future research endeavors. Thus, this paper contributes valuable insights to the cyber security field, fostering advancements for the application of AI/ML.
- 17 November 2024
- Published by MDPI AG in Journal of Cybersecurity and Privacy
- Vol. 4 (4) , 972-992
Open AccessApplications of Machine Learning in Cyber Security: A Review
In recent years, Machine Learning (ML) and Artificial Intelligence (AI) have been gaining ground in Cyber Security (CS) research in an attempt to counter increasingly sophisticated attacks. However, this paper poses the question of qualitative and quantitative data. This paper argues that scholarly research in this domain is severely impacted by the quality and quantity of available data. Datasets are disparate. There is no uniformity in (i) the dataset features, (ii) the methods of collection, or (iii) the preprocessing requirements to enable good-quality analyzed data that are suitable for automated decision-making. This review contributes to the existing literature by providing a single summary of the wider field in relation to AI, evaluating the most recent datasets, combining considerations of ethical AI, and posing a list of open research questions to guide future research endeavors. Thus, this paper contributes valuable insights to the cyber security field, fostering advancements for the application of AI/ML.
- 3 June 2022
- Published by Springer Nature
- p. 241-260
Secure Data Transfer and Provenance for Distributed Healthcare
- 3 June 2022
- Published by Springer Nature
- p. 241-260
Secure Data Transfer and Provenance for Distributed Healthcare
- 3 June 2022
- Published by Springer Nature
- p. 87-111
Accountable, Responsible, Transparent Artificial Intelligence in Ambient Intelligence Systems for Healthcare
- 3 June 2022
- Published by Springer Nature
- p. 87-111
Accountable, Responsible, Transparent Artificial Intelligence in Ambient Intelligence Systems for Healthcare
- RetractedOpen Access
- 1 January 2022
- Published by Wiley in Wireless Communications and Mobile Computing
- Vol. 2022 (1)
[Retracted] Prediction of Wear Rates of UHMWPE Bearing in Hip Joint Prosthesis with Support Vector Model and Grey Wolf Optimization
One of the greatest challenges in joint arthroplasty is to enhance the wear resistance of ultrahigh molecular weight polyethylene (UHMWPE), which is one of the most successful polymers as acetabular bearings for total hip joint prosthesis. In order to improve UHMWPE wear rates, it is necessary to develop efficient methods to predict its wear rates in various conditions and therefore help in improving its wear resistance, mechanical properties, and increasing its life span inside the body. This article presents a support vector machine using a grey wolf optimizer (SVM‐GWO) hybrid regression model to predict the wear rates of UHMWPE based on published polyethylene data from pin on disc (PoD) wear experiments typically performed in the field of prosthetic hip implants. The dataset was an aggregate of 29 different PoD UHMWPE datasets collected from Google Scholar and PubMed databases, and it consisted of 129 data points. Shapley additive explanations (SHAP) values were used to interpret the presented model to identify the most important and decisive parameters that affect the wear rates of UHMWPE and, therefore, predict its wear behavior inside the body under different conditions. The results revealed that radiation doses had the highest impact on the model’s prediction, where high values of radiation doses had a negative impact on the model output. The pronounced effect of irradiation doses and surface roughness on the wear rates of polyethylene was clear in the results when average disc surface roughness (Ra) values were below 0.05 μm, and irradiation doses were above 95 kGy produced 0 mg/MC wear rate. The proposed model proved to be a reliable and robust model for the prediction of wear rates and prioritizing factors that most significantly affect its wear rates. The proposed model can help material engineers to further design polyethylene acetabular linings via improving the wear resistance and minimizing the necessity for wear experiments.
- 1 January 2022
- Published by Wiley in Wireless Communications and Mobile Computing
- Vol. 2022 (1)
RetractedOpen Access[Retracted] Prediction of Wear Rates of UHMWPE Bearing in Hip Joint Prosthesis with Support Vector Model and Grey Wolf Optimization
One of the greatest challenges in joint arthroplasty is to enhance the wear resistance of ultrahigh molecular weight polyethylene (UHMWPE), which is one of the most successful polymers as acetabular bearings for total hip joint prosthesis. In order to improve UHMWPE wear rates, it is necessary to develop efficient methods to predict its wear rates in various conditions and therefore help in improving its wear resistance, mechanical properties, and increasing its life span inside the body. This article presents a support vector machine using a grey wolf optimizer (SVM‐GWO) hybrid regression model to predict the wear rates of UHMWPE based on published polyethylene data from pin on disc (PoD) wear experiments typically performed in the field of prosthetic hip implants. The dataset was an aggregate of 29 different PoD UHMWPE datasets collected from Google Scholar and PubMed databases, and it consisted of 129 data points. Shapley additive explanations (SHAP) values were used to interpret the presented model to identify the most important and decisive parameters that affect the wear rates of UHMWPE and, therefore, predict its wear behavior inside the body under different conditions. The results revealed that radiation doses had the highest impact on the model’s prediction, where high values of radiation doses had a negative impact on the model output. The pronounced effect of irradiation doses and surface roughness on the wear rates of polyethylene was clear in the results when average disc surface roughness (Ra) values were below 0.05 μm, and irradiation doses were above 95 kGy produced 0 mg/MC wear rate. The proposed model proved to be a reliable and robust model for the prediction of wear rates and prioritizing factors that most significantly affect its wear rates. The proposed model can help material engineers to further design polyethylene acetabular linings via improving the wear resistance and minimizing the necessity for wear experiments.
- Open Access
- 27 October 2021
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Internet of Things
- Vol. 3 (1) , 1-18
Vibration Edge Computing in Maritime IoT
IoT and the Cloud are among the most disruptive changes in the way we use data today. These changes have not significantly influenced practices in condition monitoring for shipping. This is partly due to the cost of continuous data transmission. Several vessels are already equipped with a network of sensors. However, continuous monitoring is often not utilised and onshore visibility is obscured. Edge computing is a promising solution but there is a challenge sustaining the required accuracy for predictive maintenance. We investigate the use of IoT systems and Edge computing, evaluating the impact of the proposed solution on the decision making process. Data from a sensor and the NASA-IMS open repository were used to show the effectiveness of the proposed system and to evaluate it in a realistic maritime application. The results demonstrate our real-time dynamic intelligent reduction of transmitted data volume by without sacrificing specificity or sensitivity in decision making. The output of the Decision Support System fully corresponds to the monitored system's actual operating condition and the output when the raw data are used instead. The results demonstrate that the proposed more efficient approach is just as effective for the decision making process.
- 27 October 2021
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Internet of Things
- Vol. 3 (1) , 1-18
Open AccessVibration Edge Computing in Maritime IoT
IoT and the Cloud are among the most disruptive changes in the way we use data today. These changes have not significantly influenced practices in condition monitoring for shipping. This is partly due to the cost of continuous data transmission. Several vessels are already equipped with a network of sensors. However, continuous monitoring is often not utilised and onshore visibility is obscured. Edge computing is a promising solution but there is a challenge sustaining the required accuracy for predictive maintenance. We investigate the use of IoT systems and Edge computing, evaluating the impact of the proposed solution on the decision making process. Data from a sensor and the NASA-IMS open repository were used to show the effectiveness of the proposed system and to evaluate it in a realistic maritime application. The results demonstrate our real-time dynamic intelligent reduction of transmitted data volume by without sacrificing specificity or sensitivity in decision making. The output of the Decision Support System fully corresponds to the monitored system's actual operating condition and the output when the raw data are used instead. The results demonstrate that the proposed more efficient approach is just as effective for the decision making process.
- Open Access
Individualised Responsible Artificial Intelligence for Home-Based Rehabilitation
Socioeconomic reasons post-COVID-19 demand unsupervised home-based rehabilitation and, specifically, artificial ambient intelligence with individualisation to support engagement and motivation. Artificial intelligence must also comply with accountability, responsibility, and transparency (ART) requirements for wider acceptability. This paper presents such a patient-centric individualised home-based rehabilitation support system. To this end, the Timed Up and Go (TUG) and Five Time Sit To Stand (FTSTS) tests evaluate daily living activity performance in the presence or development of comorbidities. We present a method for generating synthetic datasets complementing experimental observations and mitigating bias. We present an incremental hybrid machine learning algorithm combining ensemble learning and hybrid stacking using extreme gradient boosted decision trees and k-nearest neighbours to meet individualisation, interpretability, and ART design requirements while maintaining low computation footprint. The model reaches up to 100% accuracy for both FTSTS and TUG in predicting associated patient medical condition, and 100% or 83.13%, respectively, in predicting area of difficulty in the segments of the test. Our results show an improvement of 5% and 15% for FTSTS and TUG tests, respectively, over previous approaches that use intrusive means of monitoring such as cameras.
Open AccessIndividualised Responsible Artificial Intelligence for Home-Based Rehabilitation
Socioeconomic reasons post-COVID-19 demand unsupervised home-based rehabilitation and, specifically, artificial ambient intelligence with individualisation to support engagement and motivation. Artificial intelligence must also comply with accountability, responsibility, and transparency (ART) requirements for wider acceptability. This paper presents such a patient-centric individualised home-based rehabilitation support system. To this end, the Timed Up and Go (TUG) and Five Time Sit To Stand (FTSTS) tests evaluate daily living activity performance in the presence or development of comorbidities. We present a method for generating synthetic datasets complementing experimental observations and mitigating bias. We present an incremental hybrid machine learning algorithm combining ensemble learning and hybrid stacking using extreme gradient boosted decision trees and k-nearest neighbours to meet individualisation, interpretability, and ART design requirements while maintaining low computation footprint. The model reaches up to 100% accuracy for both FTSTS and TUG in predicting associated patient medical condition, and 100% or 83.13%, respectively, in predicting area of difficulty in the segments of the test. Our results show an improvement of 5% and 15% for FTSTS and TUG tests, respectively, over previous approaches that use intrusive means of monitoring such as cameras.
- Open Access
Evaluation of Home-Based Rehabilitation Sensing Systems with Respect to Standardised Clinical Tests
With increased demand for tele-rehabilitation, many autonomous home-based rehabilitation systems have appeared recently. Many of these systems, however, suffer from lack of patient acceptance and engagement or fail to provide satisfactory accuracy; both are needed for appropriate diagnostics. This paper first provides a detailed discussion of current sensor-based home-based rehabilitation systems with respect to four recently established criteria for wide acceptance and long engagement. A methodological procedure is then proposed for the evaluation of accuracy of portable sensing home-based rehabilitation systems, in line with medically-approved tests and recommendations. For experiments, we deploy an in-house low-cost sensing system meeting the four criteria of acceptance to demonstrate the effectiveness of the proposed evaluation methodology. We observe that the deployed sensor system has limitations in sensing fast movement. Indicators of enhanced motivation and engagement are recorded through the questionnaire responses with more than of the respondents supporting the system’s motivation and engagement enhancement. The evaluation results demonstrate that the deployed system is fit for purpose with statistically significant ( , , ) and unbiased correlation to the golden standard.Open AccessEvaluation of Home-Based Rehabilitation Sensing Systems with Respect to Standardised Clinical Tests
With increased demand for tele-rehabilitation, many autonomous home-based rehabilitation systems have appeared recently. Many of these systems, however, suffer from lack of patient acceptance and engagement or fail to provide satisfactory accuracy; both are needed for appropriate diagnostics. This paper first provides a detailed discussion of current sensor-based home-based rehabilitation systems with respect to four recently established criteria for wide acceptance and long engagement. A methodological procedure is then proposed for the evaluation of accuracy of portable sensing home-based rehabilitation systems, in line with medically-approved tests and recommendations. For experiments, we deploy an in-house low-cost sensing system meeting the four criteria of acceptance to demonstrate the effectiveness of the proposed evaluation methodology. We observe that the deployed sensor system has limitations in sensing fast movement. Indicators of enhanced motivation and engagement are recorded through the questionnaire responses with more than of the respondents supporting the system’s motivation and engagement enhancement. The evaluation results demonstrate that the deployed system is fit for purpose with statistically significant ( , , ) and unbiased correlation to the golden standard. - Open Access
- 15 August 2019
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 4 (1) , e13732
Factors That Contribute to the Use of Stroke Self-Rehabilitation Technologies: A Review
Background: Stroke is increasingly one of the main causes of impairment and disability. Contextual and empirical evidence demonstrate that, mainly due to service delivery constraints, but also due to a move toward personalized health care in the comfort of patients’ homes, more stroke survivors undergo rehabilitation at home with minimal or no supervision. Due to this trend toward telerehabilitation, systems for stroke patient self-rehabilitation have become increasingly popular, with many solutions recently proposed based on technological advances in sensing, machine learning, and visualization. However, by targeting generic patient profiles, these systems often do not provide adequate rehabilitation service, as they are not tailored to specific patients’ needs.Objective: Our objective was to review state-of-the-art home rehabilitation systems and discuss their effectiveness from a patient-centric perspective. We aimed to analyze engagement enhancement of self-rehabilitation systems, as well as motivation, to identify the challenges in technology uptake.Methods: We performed a systematic literature search with 307,550 results. Then, through a narrative review, we selected 96 sources of existing home rehabilitation systems and we conducted a critical analysis. Based on the critical analysis, we formulated new criteria to be used when designing future solutions, addressing the need for increased patient involvement and individualism. We categorized the criteria based on (1) motivation, (2) acceptance, and (3) technological aspects affecting the incorporation of the technology in practice. We categorized all reviewed systems based on whether they successfully met each of the proposed criteria.Results: The criteria we identified were nonintrusive, nonwearable, motivation and engagement enhancing, individualized, supporting daily activities, cost-effective, simple, and transferable. We also examined the motivation method, suitability for elderly patients, and intended use as supplementary criteria. Through the detailed literature review and comparative analysis, we found no system reported in the literature that addressed all the set criteria. Most systems successfully addressed a subset of the criteria, but none successfully addressed all set goals of the ideal self-rehabilitation system for home use.Conclusions: We identified a gap in the state-of-the-art in telerehabilitation and propose a set of criteria for a novel patient-centric system to enhance patient engagement and motivation and deliver better self-rehabilitation commitment.
- 15 August 2019
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 4 (1) , e13732
Open AccessFactors That Contribute to the Use of Stroke Self-Rehabilitation Technologies: A Review
Background: Stroke is increasingly one of the main causes of impairment and disability. Contextual and empirical evidence demonstrate that, mainly due to service delivery constraints, but also due to a move toward personalized health care in the comfort of patients’ homes, more stroke survivors undergo rehabilitation at home with minimal or no supervision. Due to this trend toward telerehabilitation, systems for stroke patient self-rehabilitation have become increasingly popular, with many solutions recently proposed based on technological advances in sensing, machine learning, and visualization. However, by targeting generic patient profiles, these systems often do not provide adequate rehabilitation service, as they are not tailored to specific patients’ needs.Objective: Our objective was to review state-of-the-art home rehabilitation systems and discuss their effectiveness from a patient-centric perspective. We aimed to analyze engagement enhancement of self-rehabilitation systems, as well as motivation, to identify the challenges in technology uptake.Methods: We performed a systematic literature search with 307,550 results. Then, through a narrative review, we selected 96 sources of existing home rehabilitation systems and we conducted a critical analysis. Based on the critical analysis, we formulated new criteria to be used when designing future solutions, addressing the need for increased patient involvement and individualism. We categorized the criteria based on (1) motivation, (2) acceptance, and (3) technological aspects affecting the incorporation of the technology in practice. We categorized all reviewed systems based on whether they successfully met each of the proposed criteria.Results: The criteria we identified were nonintrusive, nonwearable, motivation and engagement enhancing, individualized, supporting daily activities, cost-effective, simple, and transferable. We also examined the motivation method, suitability for elderly patients, and intended use as supplementary criteria. Through the detailed literature review and comparative analysis, we found no system reported in the literature that addressed all the set criteria. Most systems successfully addressed a subset of the criteria, but none successfully addressed all set goals of the ideal self-rehabilitation system for home use.Conclusions: We identified a gap in the state-of-the-art in telerehabilitation and propose a set of criteria for a novel patient-centric system to enhance patient engagement and motivation and deliver better self-rehabilitation commitment.