TSThomas Steffens

Thomas Steffens

*This is an algorithmically generated author record based on publicly available information.

Thomas Steffens has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    One Operating Room, Two Thermal Worlds: Determinants and Limits of Thermal Comfort for Surgical Staff

    by Mareike Ziegler, Hans-Martin Seipp, Thomas Steffens, Michael Klages, Jennifer Herzog-Niescery

    Thermal comfort in operating rooms is critical for staff performance and safety, but conflicting requirements among professional groups create complex challenges. In a real operating room with a unidirectional airflow system, air velocity and temperature were measured, and predicted thermal sensation as well as the proportion of dissatisfied staff were calculated according to international standards. Analyses included surgeons, technical assistants, and anesthesiologists, considering clothing insulation, task-specific activity, gender, body mass index, and the use of lead aprons of different weights. Gender, body mass index, and temperature strongly influenced thermal comfort, whereas variation in air velocity had only minor effects. Thermal comfort targets diverged markedly between professional groups. Under identical conditions in our operating room, up to 75% of male surgeons wearing lead aprons experienced pronounced heat stress, whereas approximately 22% of female anesthesiologists experienced predominantly cold discomfort. Female surgeons would require temperatures as low as 16 °C to achieve thermal comfort, while nearly 50% of male surgeons perceived even this temperature as uncomfortably warm. Removing lead aprons reduced heat stress in surgeons but increased cold stress in anesthesiologists. Higher body-mass index improved heat dissipation in surgeons but aggravated cold stress in anesthesiologists. These findings demonstrate that uniform temperature settings cannot ensure thermal comfort for all professional groups. Practical implications include the need for role-specific strategies, such as targeted personal cooling or warming measures and differentiated clothing systems, to improve working conditions and maintain patient safety in operating rooms.


  • Open Access

    Photoacoustic gas monitoring for anesthetic gas pollution measurements and its cross-sensitivity to alcoholic disinfectants

    by Jennifer Herzog-Niescery, Thomas Steffens, Martin Bellgardt, Andreas Breuer-Kaiser, Philipp Gude, Heike Vogelsang, Thomas Peter Weber, Hans-Martin Seipp

    Real-time photoacoustic gas monitoring is used for personnel exposure and environmental monitoring, but its accuracy varies when organic solvents such as alcohol contaminate measurements. This is problematic for anesthetic gas measurements in hospitals, because most disinfectants contain alcohol, which could lead to false-high gas concentrations. We investigated the cross-sensitivities of the photoacoustic gas monitor Innova 1412 (AirTech Instruments, LumaSense, Denmark) against alcohols and alcoholic disinfectants while measuring sevoflurane, desflurane and isoflurane in a laboratory and in hospital during surgery. 25 mL ethyl alcohol was distributed on a hotplate. An optical filter for isoflurane was used and the gas monitor measured the ‘isoflurane’ concentration for five minutes with the measuring probe fixed 30 cm above the hotplate. Then, 5 mL isoflurane was added vaporized via an Anesthetic Conserving Device (Sedana Medical, Uppsala, Sweden). After one-hour measurement, 25 mL isopropyl alcohol, N-propanol, and two alcoholic disinfectants were subsequently added, each in combination with 5 mL isoflurane. The same experiment was in turn performed for sevoflurane and desflurane. The practical impact of the cross-sensitivity was investigated on abdominal surgeons who were exposed intraoperatively to sevoflurane. A new approach to overcome the gas monitor’s cross-sensitivity is presented. Cross-sensitivity was observed for all alcohols and its strength characteristic for the tested agent. Simultaneous uses of anesthetic gases and alcohols increased the concentrations and the recovery times significantly, especially while sevoflurane was utilized. Intraoperative measurements revealed mean and maximum sevoflurane concentrations of 0.61 ± 0.26 ppm and 15.27 ± 14.62 ppm. We replaced the cross-sensitivity peaks with the 10th percentile baseline of the anesthetic gas concentration. This reduced mean and maximum concentrations significantly by 37% (p < 0.001) and 86% (p < 0.001), respectively. Photoacoustic gas monitoring is useful to detect lowest anesthetic gases concentrations, but cross-sensitivity caused one third falsely high measured mean gas concentration. One possibility to eliminate these peaks is the recovery time-based baseline approach. Caution should be taken while measuring sevoflurane, since marked cross-sensitivity peaks are to be expected.