Dua Özsoylu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dua Özsoylu has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Michael Josef Schöening
Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428 Jülich, Germany
7 shared publications Sefa Kizildag
4 shared publications- Patrick Wagner
Laboratory for Soft Matter and Biophysics, Department of Physics and Astronomy, KU Leuven, Celestijnenlaan 200 D, 3001 Leuven, Belgium
3 shared publications Torsten Wagner
Institute of Nano and Biotechnologies (INB), Aachen University of Applied Sciences, Jülich, Germany
3 shared publications- Torsten Wagner
Institute of Nano- and Biotechnologies, Aachen University of Applied Sciences, 52428 Jülich, Germany
3 shared publications Michael J. Schöning
2 shared publications
Latest Publications
- Open Access
- 10 February 2026
- Published by Elsevier in Chemical Engineering Journal
- Vol. 531
Lipopolysaccharide-templated biomimetic molecularly imprinted polymer (MIP) surfaces for high-affinity bacterial capture
- 10 February 2026
- Published by Elsevier in Chemical Engineering Journal
- Vol. 531
Open AccessLipopolysaccharide-templated biomimetic molecularly imprinted polymer (MIP) surfaces for high-affinity bacterial capture
- Open Access
- 29 January 2026
- Published by Elsevier in Applied Surface Science Advances
- Vol. 32
Nanocrystalline graphite-patterned silicon substrates for molecularly imprinted biopolymer-based electrochemical detection of glyphosate
- 29 January 2026
- Published by Elsevier in Applied Surface Science Advances
- Vol. 32
Open AccessNanocrystalline graphite-patterned silicon substrates for molecularly imprinted biopolymer-based electrochemical detection of glyphosate
- Open Access
- 13 January 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (1) , 60
Surface-Imprinted Polymer Coupled with Diffraction Gratings for Low-Cost, Label-Free and Differential E. coli Detection
Surface-imprinted polymer (SIP)-based biomimetic sensors are promising for direct whole-bacteria detection; however, the commonly used fabrication approach (micro-contact imprinting) often suffers from limited imprint density, heterogeneous template distribution, and poor reproducibility. Here, we introduce a photolithography-defined master stamp featuring E. coli mimics, enabling high-density, well-oriented cavity arrays (3 × 107 imprints/cm2). Crucially, the cavity arrangement is engineered such that the SIP layer functions simultaneously as the bioreceptor and as a diffraction grating, enabling label-free optical quantification by reflectance changes without additional transduction layers. Finite-difference time-domain (FDTD) simulations are used to model and visualize the optical response upon bacterial binding. Proof-of-concept experiments using a differential two-well configuration confirm concentration-dependent detection of E. coli in PBS, demonstrating a sensitive, low-cost, and scalable sensing concept that can be readily extended to other bacterial targets by redesigning the photolithographic master.
- 13 January 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (1) , 60
Open AccessSurface-Imprinted Polymer Coupled with Diffraction Gratings for Low-Cost, Label-Free and Differential E. coli Detection
Surface-imprinted polymer (SIP)-based biomimetic sensors are promising for direct whole-bacteria detection; however, the commonly used fabrication approach (micro-contact imprinting) often suffers from limited imprint density, heterogeneous template distribution, and poor reproducibility. Here, we introduce a photolithography-defined master stamp featuring E. coli mimics, enabling high-density, well-oriented cavity arrays (3 × 107 imprints/cm2). Crucially, the cavity arrangement is engineered such that the SIP layer functions simultaneously as the bioreceptor and as a diffraction grating, enabling label-free optical quantification by reflectance changes without additional transduction layers. Finite-difference time-domain (FDTD) simulations are used to model and visualize the optical response upon bacterial binding. Proof-of-concept experiments using a differential two-well configuration confirm concentration-dependent detection of E. coli in PBS, demonstrating a sensitive, low-cost, and scalable sensing concept that can be readily extended to other bacterial targets by redesigning the photolithographic master.
- 17 February 2025
- Published by Walter de Gruyter GmbH in Journal of Pediatric Endocrinology and Metabolism
- Vol. 38 (4) , 318-325
Is oxytocin related to psychiatric symptoms in adolescents with obesity?
Objectives: We aimed to investigate the relation of oxytocin receptor (OXTR) gene variants (rs53576 and rs2254298) and serum oxytocin (OXT) levels with psychiatric symptoms in healthy adolescents and adolescents with obesity. Methods: A total of 250 adolescents with obesity and 250 healthy adolescents were included in this study. Attachment properties, anxiety, and depression were evaluated with self-reports while diagnoses were ascertained with KIDDIE-SADS-PL Turkish version. Serum OXT level was studied with the ELISA method, and OXTR gene variants were studied by quantitative polymerase chain reaction (rs53576) and restriction fragment length polymorphism (RFLP) (rs2254298) methods. Results: Serum OXT level was significantly lower in adolescents with obesity than in healthy controls. Self-reported symptoms of anxiety and depression were significantly elevated, especially in female adolescents with obesity, whereas parent/peer attachment was significantly lower. The rs53576 G/G genotype was found to be significantly more prevalent among obese youth. About 29.2 % of obese youth were diagnosed with psychopathology, especially anxiety and depression. OXT levels and receptor polymorphisms were not related to self-reported symptoms, attachment, and presence of psychopathology. Conclusions: Further studies should evaluate the roles of other constructs (e.g., early adversity, parenting, social supports, coping, temperament, etc.) and discern the roles of parent–child synchrony in elucidating relationships between OXT, pediatric obesity, and psychopathology.
- 17 February 2025
- Published by Walter de Gruyter GmbH in Journal of Pediatric Endocrinology and Metabolism
- Vol. 38 (4) , 318-325
Is oxytocin related to psychiatric symptoms in adolescents with obesity?
Objectives: We aimed to investigate the relation of oxytocin receptor (OXTR) gene variants (rs53576 and rs2254298) and serum oxytocin (OXT) levels with psychiatric symptoms in healthy adolescents and adolescents with obesity. Methods: A total of 250 adolescents with obesity and 250 healthy adolescents were included in this study. Attachment properties, anxiety, and depression were evaluated with self-reports while diagnoses were ascertained with KIDDIE-SADS-PL Turkish version. Serum OXT level was studied with the ELISA method, and OXTR gene variants were studied by quantitative polymerase chain reaction (rs53576) and restriction fragment length polymorphism (RFLP) (rs2254298) methods. Results: Serum OXT level was significantly lower in adolescents with obesity than in healthy controls. Self-reported symptoms of anxiety and depression were significantly elevated, especially in female adolescents with obesity, whereas parent/peer attachment was significantly lower. The rs53576 G/G genotype was found to be significantly more prevalent among obese youth. About 29.2 % of obese youth were diagnosed with psychopathology, especially anxiety and depression. OXT levels and receptor polymorphisms were not related to self-reported symptoms, attachment, and presence of psychopathology. Conclusions: Further studies should evaluate the roles of other constructs (e.g., early adversity, parenting, social supports, coping, temperament, etc.) and discern the roles of parent–child synchrony in elucidating relationships between OXT, pediatric obesity, and psychopathology.
- Open Access
- 13 June 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 261, 116491
Template bacteria-free fabrication of surface imprinted polymer-based biosensor for E. coli detection using photolithographic mimics: Hacking bacterial adhesion
- 13 June 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 261, 116491
Open AccessTemplate bacteria-free fabrication of surface imprinted polymer-based biosensor for E. coli detection using photolithographic mimics: Hacking bacterial adhesion
- Open Access
- 4 June 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (6) , 755
Development and Calibration of a Microfluidic, Chip-Based Sensor System for Monitoring the Physical Properties of Water Samples in Aquacultures
In this work, we present a compact, bifunctional chip-based sensor setup that measures the temperature and electrical conductivity of water samples, including specimens from rivers and channels, aquaculture, and the Atlantic Ocean. For conductivity measurements, we utilize the impedance amplitude recorded via interdigitated electrode structures at a single triggering frequency. The results are well in line with data obtained using a calibrated reference instrument. The new setup holds for conductivity values spanning almost two orders of magnitude (river versus ocean water) without the need for equivalent circuit modelling. Temperature measurements were performed in four-point geometry with an on-chip platinum RTD (resistance temperature detector) in the temperature range between 2 °C and 40 °C, showing no hysteresis effects between warming and cooling cycles. Although the meander was not shielded against the liquid, the temperature calibration provided equivalent results to low conductive Milli-Q and highly conductive ocean water. The sensor is therefore suitable for inline and online monitoring purposes in recirculating aquaculture systems.
- 4 June 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (6) , 755
Open AccessDevelopment and Calibration of a Microfluidic, Chip-Based Sensor System for Monitoring the Physical Properties of Water Samples in Aquacultures
In this work, we present a compact, bifunctional chip-based sensor setup that measures the temperature and electrical conductivity of water samples, including specimens from rivers and channels, aquaculture, and the Atlantic Ocean. For conductivity measurements, we utilize the impedance amplitude recorded via interdigitated electrode structures at a single triggering frequency. The results are well in line with data obtained using a calibrated reference instrument. The new setup holds for conductivity values spanning almost two orders of magnitude (river versus ocean water) without the need for equivalent circuit modelling. Temperature measurements were performed in four-point geometry with an on-chip platinum RTD (resistance temperature detector) in the temperature range between 2 °C and 40 °C, showing no hysteresis effects between warming and cooling cycles. Although the meander was not shielded against the liquid, the temperature calibration provided equivalent results to low conductive Milli-Q and highly conductive ocean water. The sensor is therefore suitable for inline and online monitoring purposes in recirculating aquaculture systems.
- 28 April 2022
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (12) , 825-833
Photopolymer composite magnetic actuators for cell-based biosensors
Nowadays, biosensors play a significant role in numerous areas and become part of our daily life. Here, electrochemical cell-based biosensors either use cells as a biorecognition element or they can monitor physiologically relevant information of cells. One of the greatest challenges for commercialization of cell-based biosensors comes from their main component, the cells, which are complex “living” systems and very vulnerable to environmental changes. Recently, to address this issue, a novel method, the cryopreservation of cell monolayers in a ready-to-use set-up, has been introduced. To further improve this method, herein we develop photopolymer-based magnetic composites (cell carriers) by photolithographically patterning different photopolymer resins (flexible resin and SU-8 photoresist) mixed with superparamagnetic iron oxide (Fe3O4) nanoparticles. These magnetic composites were designed for cryopreservation of cells grown on them in a ready-to-use concept: it allows the on-demand transfer of the actuators to the culture environment with integrated cell-based biosensor and positioning them close to the sensor surface or taking them away for the next cell population on another actuator by an external magnetic field. The key performance characteristics of the developed magnetic composites such as being able to control their location, mobility and orientation have been demonstrated in cell culture medium.
- 28 April 2022
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (12) , 825-833
Photopolymer composite magnetic actuators for cell-based biosensors
Nowadays, biosensors play a significant role in numerous areas and become part of our daily life. Here, electrochemical cell-based biosensors either use cells as a biorecognition element or they can monitor physiologically relevant information of cells. One of the greatest challenges for commercialization of cell-based biosensors comes from their main component, the cells, which are complex “living” systems and very vulnerable to environmental changes. Recently, to address this issue, a novel method, the cryopreservation of cell monolayers in a ready-to-use set-up, has been introduced. To further improve this method, herein we develop photopolymer-based magnetic composites (cell carriers) by photolithographically patterning different photopolymer resins (flexible resin and SU-8 photoresist) mixed with superparamagnetic iron oxide (Fe3O4) nanoparticles. These magnetic composites were designed for cryopreservation of cells grown on them in a ready-to-use concept: it allows the on-demand transfer of the actuators to the culture environment with integrated cell-based biosensor and positioning them close to the sensor surface or taking them away for the next cell population on another actuator by an external magnetic field. The key performance characteristics of the developed magnetic composites such as being able to control their location, mobility and orientation have been demonstrated in cell culture medium.
- 1 April 2022
- Published by Bentham Science Publishers Ltd. in Current Topics in Medicinal Chemistry
- Vol. 22 (9) , 713-733
Electrochemical Cell-based Biosensors for Biomedical Applications
Electrochemical cell-based biosensors have attracted increasing interest within the last 15 years, with a large number of reports generally dealing with the sensors’ sensitivity, selectivity, sta-bility, signal-to-noise ratio, spatiotemporal resolution, etc. However, only a few of them are now available as commercial products. In this review, technological advances, current challenges, and opportunities of electrochemical cell-based biosensors are presented. The article encompasses emerging studies on cell-based biological field-effect devices, cell-based impedimetric sensors, and cell-based microelectrode arrays, mainly focusing on the last five years (from 2016 to mid-2021). In addition, special attention lies in recent progress at the single-cellular level, including intracellular monitoring with high spatiotemporal resolution as well as integration into microfluidics for lab-on-a-chip applications. Moreover, a comprehensive discussion on challenges and future perspectives will address the future potential of electrochemical cell-based biosensors.
- 1 April 2022
- Published by Bentham Science Publishers Ltd. in Current Topics in Medicinal Chemistry
- Vol. 22 (9) , 713-733
Electrochemical Cell-based Biosensors for Biomedical Applications
Electrochemical cell-based biosensors have attracted increasing interest within the last 15 years, with a large number of reports generally dealing with the sensors’ sensitivity, selectivity, sta-bility, signal-to-noise ratio, spatiotemporal resolution, etc. However, only a few of them are now available as commercial products. In this review, technological advances, current challenges, and opportunities of electrochemical cell-based biosensors are presented. The article encompasses emerging studies on cell-based biological field-effect devices, cell-based impedimetric sensors, and cell-based microelectrode arrays, mainly focusing on the last five years (from 2016 to mid-2021). In addition, special attention lies in recent progress at the single-cellular level, including intracellular monitoring with high spatiotemporal resolution as well as integration into microfluidics for lab-on-a-chip applications. Moreover, a comprehensive discussion on challenges and future perspectives will address the future potential of electrochemical cell-based biosensors.
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (55) , 1391
On-Sensor Cryopreservation of Adherent Cells in Lab-on-a-Chip Systems
Introduction Biochemical sensors are one of the essential tools for cell-based assays used in major research fields including drug discovery, cancer research, and immunology. Although significant efforts have been made to develop new technologies and tools, most existing systems in this field are still not suitable for “ready‐to‐use in-field” applications, as the cells inside the assay need vital parameters, such as oxygen, nutrients, and temperature and therefore will not survive during a transportation to an end user. Nevertheless, providing these parameters is not practicable during conventional transportation either. Those systems need to be assembled and prepared on-site, which often requires a cell culture laboratory setting and trained staff. Thus, there is an urgent need for preserving the whole optimized assay system to utilize them for concepts like “ready-to-use” or “on-demand-use”. Cryopreservation, the process of freezing and preserving the cells at sub-zero temperatures is a well-known technique for cell culturing. It could be one possible solution to solve the transportation and storage challenges in the fields mentioned above. However, freezing of adherent cells is more prone to the cell membrane damage and cell detachment, due to ice crystal formation and a mismatch in the linear thermal expansion between the frozen cell membrane and the rigid substrate [1]. Therefore, innovative methods and tools must be implemented to overcome these challenges. In this work, for the first time, the surface of a field-effect-based sensor was modified with flexible electrospun fibers to allow on-sensor cryopreservation. Furthermore, a protocol was developed to freeze and to thaw adherent cells in a microfluidic channel. Method The light-addressable potentiometric sensor (LAPS), a field-effect-based biochemical sensor, can detect the extracellular acidification of the cells due to its pH sensitive transducer layer (Ta2O5). The LAPS was fabricated as a structure of Al/p-Si/SiO2/Ta2O5 as described in ref. [2]. The sensor surface was modified with flexible polyethylene vinyl acetate (PEVA) fibers using an electrospinning method. The modified LAPS chip was then fixed to the underside of a bottomless microfluidic slide to form a miniaturized device (cryo-chip) (Figure 1(a) and (b)). A flexible polymer coverslip and a conventional LAPS were used as control samples. All samples were sterilized by 70% ethanol for one hour under aseptic conditions in a laminar flow cabinet to maintain the sterility. Chinese hamster ovary (CHO-K1) cells were adherently cultured inside the channels of the device with the mixture of Ham’s Nutrient Mixture F-12/Dulbecco’s Modified Eagle Medium (Ham’s F-12/DMEM, 1:2 mixture, pH 7) supplemented with 5% fetal calf serum (FCS), 100 U/ml penicillin and 100 mg/ml streptomycin. After the cell culture inside the channels were obtained for 48h under cell culture conditions in an incubator, the entire device was placed in a 3D-printed freezing container and frozen at -80oC using a cryoprotectant solution (90% fetal calf serum supplemented with 10% dimethyl sulfoxide). The samples were kept in the freezer overnight. The frozen device was then thawed rapidly by transferring them directly to the incubator (37oC). The cryoprotectant solution inside the channels was removed by washing with the fresh medium (37oC) four times, as soon as the ice crystals disappeared. Cell recovery and cell viability were analyzed before and after cryopreservation using a dye exclusion assay and a cell counting kit (CCK)-8 assay. In addition, as proof-of-concept measurements, the extracellular acidification of the cells was monitored by the LAPS chip, after the cryopreservation. Results and Conclusions The results showed that the sensor surface modified with the electrospun PEVA fibers exhibits enhanced biocompatibility, which promotes cell proliferation and spreading. In addition, the novel cryo-chip system using this hybrid structure (rigid/flexible) is effective compared to an un-modified LAPS surface for keeping cells viable during on-sensor cryopreservation. These findings showed, for the first time, that a cryopreservation on-chip is possible and that microfluidic systems including semiconductor based sensors can survive the cryopreservation treatment. Thus, this kind of cryo-chip systems enable on-sensor cryopreservation and measurement which can open up a new possibility for “ready-to-use, in field” applications. Being able to prepare the entire system at the manufacturing stage and to send them via a cold-chain transport further eliminate potential run-to-run and operator-to-operator variability, resulting in more reproducible results. Acknowledgements Dua Özsoylu (DÖ) would like to acknowledge the PhD research scholarship grant from Scientific and Technological Research Council of Turkey (TÜBITAK) under BIDEB 2214-A. The authors also gratefully thank the Federal Ministry of Education and Research of Germany (Opto-Switch FKZ: 13N12585). This study is a part of PhD thesis study of DÖ (thesis number DEU. HSI. PhD-2013970198) in Dokuz Eylül University, Institute of Health Sciences, Turkey. References [1] T. Rutt, N. Eskandari, M. Zhurova, J.A.W. Elliott, L.E. McGann, J.P. Acker, J.A. Nychka, Thermal expansion of substrate may affect adhesion of Chinese hamster fibroblasts to surfaces during freezing, Cryobiology. 86 (2019), 134–139. doi.org/10.1016/j.cryobiol.2018.10.006. [2] D. Özsoylu, S. Kizildag, M.J. Schöning, T. Wagner, Effect of plasma treatment on the sensor properties of a light-addressable potentiometric sensor (LAPS), physica status solidi (a). 216 (2019), 1900259. doi.org/10.1002/pssa.201900259. Figure 1: Photos of the cryo-chip system for on-sensor cryopreservation. a) The modified LAPS chip integrated in a microfluidic chip system and its complementary connections; b) culturing of the CHO-K1 cells inside the channels on the LAPS surface, which are modified by electrospun PEVA fibers. Figure 1
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (55) , 1391
On-Sensor Cryopreservation of Adherent Cells in Lab-on-a-Chip Systems
Introduction Biochemical sensors are one of the essential tools for cell-based assays used in major research fields including drug discovery, cancer research, and immunology. Although significant efforts have been made to develop new technologies and tools, most existing systems in this field are still not suitable for “ready‐to‐use in-field” applications, as the cells inside the assay need vital parameters, such as oxygen, nutrients, and temperature and therefore will not survive during a transportation to an end user. Nevertheless, providing these parameters is not practicable during conventional transportation either. Those systems need to be assembled and prepared on-site, which often requires a cell culture laboratory setting and trained staff. Thus, there is an urgent need for preserving the whole optimized assay system to utilize them for concepts like “ready-to-use” or “on-demand-use”. Cryopreservation, the process of freezing and preserving the cells at sub-zero temperatures is a well-known technique for cell culturing. It could be one possible solution to solve the transportation and storage challenges in the fields mentioned above. However, freezing of adherent cells is more prone to the cell membrane damage and cell detachment, due to ice crystal formation and a mismatch in the linear thermal expansion between the frozen cell membrane and the rigid substrate [1]. Therefore, innovative methods and tools must be implemented to overcome these challenges. In this work, for the first time, the surface of a field-effect-based sensor was modified with flexible electrospun fibers to allow on-sensor cryopreservation. Furthermore, a protocol was developed to freeze and to thaw adherent cells in a microfluidic channel. Method The light-addressable potentiometric sensor (LAPS), a field-effect-based biochemical sensor, can detect the extracellular acidification of the cells due to its pH sensitive transducer layer (Ta2O5). The LAPS was fabricated as a structure of Al/p-Si/SiO2/Ta2O5 as described in ref. [2]. The sensor surface was modified with flexible polyethylene vinyl acetate (PEVA) fibers using an electrospinning method. The modified LAPS chip was then fixed to the underside of a bottomless microfluidic slide to form a miniaturized device (cryo-chip) (Figure 1(a) and (b)). A flexible polymer coverslip and a conventional LAPS were used as control samples. All samples were sterilized by 70% ethanol for one hour under aseptic conditions in a laminar flow cabinet to maintain the sterility. Chinese hamster ovary (CHO-K1) cells were adherently cultured inside the channels of the device with the mixture of Ham’s Nutrient Mixture F-12/Dulbecco’s Modified Eagle Medium (Ham’s F-12/DMEM, 1:2 mixture, pH 7) supplemented with 5% fetal calf serum (FCS), 100 U/ml penicillin and 100 mg/ml streptomycin. After the cell culture inside the channels were obtained for 48h under cell culture conditions in an incubator, the entire device was placed in a 3D-printed freezing container and frozen at -80oC using a cryoprotectant solution (90% fetal calf serum supplemented with 10% dimethyl sulfoxide). The samples were kept in the freezer overnight. The frozen device was then thawed rapidly by transferring them directly to the incubator (37oC). The cryoprotectant solution inside the channels was removed by washing with the fresh medium (37oC) four times, as soon as the ice crystals disappeared. Cell recovery and cell viability were analyzed before and after cryopreservation using a dye exclusion assay and a cell counting kit (CCK)-8 assay. In addition, as proof-of-concept measurements, the extracellular acidification of the cells was monitored by the LAPS chip, after the cryopreservation. Results and Conclusions The results showed that the sensor surface modified with the electrospun PEVA fibers exhibits enhanced biocompatibility, which promotes cell proliferation and spreading. In addition, the novel cryo-chip system using this hybrid structure (rigid/flexible) is effective compared to an un-modified LAPS surface for keeping cells viable during on-sensor cryopreservation. These findings showed, for the first time, that a cryopreservation on-chip is possible and that microfluidic systems including semiconductor based sensors can survive the cryopreservation treatment. Thus, this kind of cryo-chip systems enable on-sensor cryopreservation and measurement which can open up a new possibility for “ready-to-use, in field” applications. Being able to prepare the entire system at the manufacturing stage and to send them via a cold-chain transport further eliminate potential run-to-run and operator-to-operator variability, resulting in more reproducible results. Acknowledgements Dua Özsoylu (DÖ) would like to acknowledge the PhD research scholarship grant from Scientific and Technological Research Council of Turkey (TÜBITAK) under BIDEB 2214-A. The authors also gratefully thank the Federal Ministry of Education and Research of Germany (Opto-Switch FKZ: 13N12585). This study is a part of PhD thesis study of DÖ (thesis number DEU. HSI. PhD-2013970198) in Dokuz Eylül University, Institute of Health Sciences, Turkey. References [1] T. Rutt, N. Eskandari, M. Zhurova, J.A.W. Elliott, L.E. McGann, J.P. Acker, J.A. Nychka, Thermal expansion of substrate may affect adhesion of Chinese hamster fibroblasts to surfaces during freezing, Cryobiology. 86 (2019), 134–139. doi.org/10.1016/j.cryobiol.2018.10.006. [2] D. Özsoylu, S. Kizildag, M.J. Schöning, T. Wagner, Effect of plasma treatment on the sensor properties of a light-addressable potentiometric sensor (LAPS), physica status solidi (a). 216 (2019), 1900259. doi.org/10.1002/pssa.201900259. Figure 1: Photos of the cryo-chip system for on-sensor cryopreservation. a) The modified LAPS chip integrated in a microfluidic chip system and its complementary connections; b) culturing of the CHO-K1 cells inside the channels on the LAPS surface, which are modified by electrospun PEVA fibers. Figure 1
- Open Access
- 1 December 2020
- Published by Elsevier in Physics in Medicine
- Vol. 10
Differential chemical imaging of extracellular acidification within microfluidic channels using a plasma-functionalized light-addressable potentiometric sensor (LAPS)
- 1 December 2020
- Published by Elsevier in Physics in Medicine
- Vol. 10
Open AccessDifferential chemical imaging of extracellular acidification within microfluidic channels using a plasma-functionalized light-addressable potentiometric sensor (LAPS)