ATAndreia Tomazoni

Andreia Tomazoni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andreia Tomazoni has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Methods for peripherally inserted central catheter measurement in neonates and children: protocol for a randomized controlled trial

    by Giulia R. S. Regne, Catharine G. Diniz, Andreia Tomazoni, Denise M. Kusahara, Luciano M. Dos Santos, Patrícia K. Rocha, Bruna F. Manzo

    Background: Peripherally inserted central catheters (PICC) are widely used in neonates and children requiring intravenous therapy due to their clinical advantages. However, incorrect catheter tip positioning remains frequent and may lead to serious complications. The conventional anatomical landmark–based measurement presents important accuracy limitations. A new approach, the Tomazoni method, has been proposed to improve tip positioning, but current evidence is limited to a small single-center study, highlighting the need for further investigation in broader populations. The objective is to describe a study protocol designed to prospectively evaluate the effectiveness of the Tomazoni measurement method for PICC insertion in neonates and children. Methods: Study protocol for a pragmatic, parallel-group, double-blind randomized clinical trial. Eligible participants will be neonates and children requiring upper-limb PICC insertion. The control group will undergo the traditional measurement method, while the experimental group will receive the Tomazoni method. Data will be collected using an instrument including patient, procedure, and catheter characteristics. Analyses are planned to involve frequency distributions, association tests, and relative risk. The primary outcome will be the initial catheter tip position. Conclusions: The findings are expected to contribute to the development of safer and more effective practices in PICC insertion in children and neonates’ populations, supporting patient safety and quality of care in critical neonatal and pediatric environments.

  • Open Access

    Knowledge translation technologies for educating child health professionals: a scoping review

    by Kaili da Silva Medeiros, Andreia Tomazoni, Thiago Lopes Silva, Aline de Souza Bitencourt, Isadora Silva de Souza, Michel Zaghi Vitor, Sayonara Stéfane Tavares de Moura, Jane Cristina Anders, Patrícia Kuerten Rocha

    Objective To map scientific evidence on the technological tools that have been used in knowledge translation for the education of professionals in the context of child health. Methods This is a scoping review. The JBI Manual for Evidence Synthesis recommendations were followed. Primary studies, with no time restrictions, in Portuguese, English, and Spanish were included. The search was conducted across eight databases up to November 2022. Rayyan® QCRI software was used for the screening process. Data analysis occurred in three stages: data extraction, thematic categorization, and synthesis. Results The sample included 14 studies. Canada stood out as the largest publisher of studies in this area. Most of the technologies created were soft-hard and hard, with video being the most produced technology. Conclusion The video stood out as the primary technology used in the education of healthcare professionals in pediatric settings. We can see the importance of educational technologies in health as promoters of knowledge translation and facilitators in the process of continuing education for healthcare professionals who work in child healthcare.

  • Open Access

    Técnicas de reposicionamento de cateter venoso central de inserção periférica: revisão integrativa

    by Leticia Velozo Domingos Pinto, Gisele Weissheimer Kaufmann, Clélia Mozara Giacomozzi, Andreia Tomazoni

    Objetivo: identificar as técnicas de reposicionamento da ponta do cateter central de inserção periférica disponíveis na literatura científica. Método: revisão integrativa de literatura conduzida entre os meses de junho de 2022 e abril de 2024, nas bases de dados Scopus, Web of Science, MEDLINE/Pubmed, biblioteca virtual SciELO por meio de descritores que resultaram em 209 registros. Após a leitura simultânea e independente de duas pesquisadoras, e da aplicação dos critérios de elegibilidade, foram selecionadas 18 publicações. Utilizou-se a análise categorial temática dos dados. Resultados: identificaram-se sete técnicas: reposicionamento espontâneo, manobras combinadas, movimentação de membros superiores, infusão rápida e simultânea de solução fisiológica/Simultaneos Rapid Saline Flush Technique, infusão rápida de solução fisiológica/Rapid Saline Flush Technique, High-Flow-Flush-Tecnhique e tração. Quanto aos estudos incluídos, estes alcançaram a conformidade de 40 a 87,5% em relação aos respectivos instrumentos de avaliação de viés. Conclusão: sugere-se a utilização de técnicas não invasivas para o reposicionamento do cateter de forma cautelosa. Destaca-se a relevância da competência profissional na tomada de decisões, a fim de garantir um cuidado seguro, de qualidade e prevenir os eventos adversos.

  • Open Access

    PICCTIP TOOL: VIDEO VALIDITY FOR MEASUREMENT OF PERIPHERALLY INSERTED CENTRAL CATHETER IN INFANTS

    by Kaili da Silva Medeiros, Andreia Tomazoni, Sabrina de Souza, Jefferson Wildes da Silva Moura, Thiago Lopes Silva, Patrícia de Amorim Rodrigues, Denise Miyuki Kusahara, Patrícia Kurten Rocha

    Objective: To validate the content and appearance of a video about PICCTIP Tool for measuring PICC in infants. Method: A methodological study to validate a video about PICCTIP Tool. Validity occurred based on video assessment by 78 judges (nurses, educators and designers) from July to August 2023. The Content Validity index was used to analyze the data, and internal consistency was measured by Cronbach’s alpha, with a cut-off point of 0.80 or greater and 0.75, respectively. Results: The video content was validated with an overall index of 0.98 in the nurses category, 0.99 in the pedagogues category and 0.90 in the designers category. Appearance was also validated with indexes of 0.97 in the nurses and pedagogues categories and 0.95 in the designers category. Regarding overall appearance, Cronbach’s alpha obtained in the nurses category was 0.98, in the pedagogues category it was 0.99 and in the designers category it was 0.96. Conclusion: The video about PICCTIP Tool is valid in terms of content and appearance, and has good internal consistency. It can be used as a knowledge translation tool for qualified physicians and nurses who perform PICC insertion in infants.

  • Open Access

    FERRAMENTA PICCTIP: VALIDAÇÃO DE VÍDEO PARA MENSURAÇÃO DO CATETER CENTRAL DE INSERÇÃO PERIFÉRICA EM NEONATOS

    by Kaili da Silva Medeiros, Andreia Tomazoni, Sabrina de Souza, Jefferson Wildes da Silva Moura, Thiago Lopes Silva, Patrícia de Amorim Rodrigues, Denise Miyuki Kusahara, Patrícia Kurten Rocha

    RESUMO Objetivo: Validar o conteúdo e aparência de um vídeo sobre a Ferramenta PICCTIP para mensuração do PICC em neonatos. Método: Estudo metodológico para validação de vídeo sobre a Ferramenta PICCTIP. A validação ocorreu a partir da avaliação do vídeo por 78 juízes (enfermeiros, pedagogos e designers), no período de julho a agosto de 2023. Para a análise dos dados foi utilizado o índice de Validação de Conteúdo e a consistência interna foi mensurada pelo Alpha de Cronbach, tendo como ponto de corte valor igual ou superior a 0,80 e 0,75, respectivamente. Resultados: O vídeo teve seu conteúdo validado com índice global de 0,98 na categoria dos enfermeiros, 0,99 na categoria pedagogos e 0,90 na categoria designers. A aparência também foi validada com índices de 0,97 nas categorias dos enfermeiros e pedagogos e 0,95 na categoria designers. Quanto a aparência geral, o alfa de Cronbach obtido na categoria dos enfermeiros foi 0,98, na categoria pedagogos de 0,99 e designers de 0,96. Conclusão: O vídeo sobre a Ferramenta PICCTIP é válido quanto ao conteúdo e aparência, além de possuir uma boa consistência interna. Pode ser utilizado como uma ferramenta para translação do conhecimento, para médicos e enfermeiros habilitados que realizam a inserção de PICC em neonatos.

  • Tecnologias de translação do conhecimento para educação de profissionais da saúde da criança: revisão de escopo

    by Kaili da Silva Medeiros, Andreia Tomazoni, Thiago Lopes Silva, Aline de Souza Bitencourt, Isadora Silva de Souza, Michel Zaghi Vitor, Sayonara Stéfane Tavares de Moura, Jane Cristina Anders, Patrícia Kuerten Rocha

  • Open Access

    Efficacy of disinfection procedures to reduce Acinetobacter baumanii blaOXA-23 contamination rate of needleless connectors: an in-vitro study

    by C. Biazus-Dalcin, T.C.M. Sincero, C.P. Zamparette, D.C. Tartari, S. de Souza, T.L. Silva, A. Tomazoni, P.K. Rocha


  • Open Access

    Obstrução do cateter central de inserção periférica nas transfusões de concentrado de hemácias em neonatos

    by Maria Gorete de Brito Cunha, Mitzy Tânnia Reichembach Danski, Clélia Mozara Giacomozzi, Andreia Tomazoni, Denise Miyuki Kussahara

    RESUMO Objetivos: estimar incidência e tempo livre de obstrução do cateter central de inserção periférica em recém-nascidos submetidos à transfusão de hemácias nas primeiras 24 horas após o procedimento. Métodos: estudo longitudinal, realizado com neonatos em Unidade de Terapia Intensiva Neonatal em hospital de ensino do Paraná, entre janeiro e julho de 2019. Amostra foi composta por 46 eventos de transfusões realizadas em neonatos pelo cateter central de inserção periférica. Análise realizada segundo estatística descritiva. Resultados: foram analisados 31 cateteres, inseridos em 24 neonatos, por meio dos quais foram realizadas 46 transfusões de hemácias. A maioria dos neonatos era do sexo masculino, idade gestacional <32 semanas, peso <1.500 gramas, internados principalmente por prematuridade. Dentre os 31 cateteres, um (3,2%) apresentou obstrução após a transfusão. Conclusões: A ocorrência de obstruções imediatamente após transfusão foi baixa e os cateteres permaneceram livres da complicação nas 24h seguintes.


  • Open Access

    Peripherally inserted central catheter obstruction in packed red blood cell transfusions in neonates

    by Maria Gorete de Brito Cunha, Mitzy Tânnia Reichembach Danski, Clélia Mozara Giacomozzi, Andreia Tomazoni, Denise Miyuki Kussahara

    Objectives: to estimate incidence and free time of peripherally inserted central catheter obstruction in newborns undergoing red blood cell transfusion in the first 24 hours after the procedure. Methods: a longitudinal study, carried out with neonates in Neonatal Intensive Care Unit at a teaching hospital in Paraná, between January and July 2019. The sample consisted of 46 transfusion events performed in neonates through a peripherally inserted central catheter. Analysis performed according to descriptive statistics. Results: thirty-one catheters were analyzed, inserted in 24 neonates, through which 46 red blood cell transfusions were performed. Most neonates were male, gestational age <32 weeks, weight <1,500 grams, hospitalized mainly for prematurity. Among the 31 catheters, one (3.2%) presented obstruction after transfusion. Conclusions: The occurrence of obstructions immediately after transfusion was low and the catheters remained complication free for the next 24 hours.


  • Open Access

    Methods for measuring venous peripherally inserted central catheters in newborns

    by Andreia Tomazoni, Patrícia Kuerten Rocha, Mavilde da Luz Gonçalves Pedreira, Elisa da Conceição Rodrigues, Bruna Figueiredo Manzo, Luciano Marques dos Santos

    Objective: to analyze the results of insertion procedures of Peripherally Inserted Central Catheters in newborns using two measurement methods. Methods: this is a randomized clinical trial, presenting descriptive and exploratory results of variables. It was held at a Neonatal Intensive Care Unit. Data were collected between September 2018 and 2019. The sample analyzed was 88 catheter insertion procedures, distributed in two groups. Study approved by an Institutional Review Board and obtained registration in the country and abroad. Descriptive analysis and logistic regression of data. Results: modified measurement obtained a significant difference for the central catheter tip location. Elective removals and adverse events were not significant between groups; however, poor positioning was related to adverse events. Conclusions: between the two methods analyzed, the modified measurement obtained better results in the proper catheter tip positioning and, consequently, less risk to patients.