Shuang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuang Zhang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bo Jiang
Beijing Engineering Research Center of Precision Measurement Technology and Instruments (Beijing University of Technology), Beijing 100124, China
1 shared publication - Hongfang Chen
Beijing Engineering Research Center of Precision Measurement Technology and Instruments, Beijing University of Technology, Beijing 100124, People’s Republic of China
1 shared publication - Hu Lin
National Institute of Metrology, Chaoyang, Beijing, China
1 shared publication - Huixu Song
Beijing Engineering Research Center of Precision Measurement Technology and Instruments (Beijing University of Technology), Beijing 100124, China
1 shared publication - Yanqiang Sun
School of Construction Machinery, Shandong Jiaotong University, Jinan 250357, China
1 shared publication - Zhaoyao Shi
Beijing Engineering Research Center of Precision Measurement Technology and Instruments, Beijing University of Technology, Beijing 100124, China
1 shared publication
Latest Publications
- Open Access
- 19 August 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (16) , 3417
Calibration Method for Angular Positioning Deviation of a High-Precision Rotary Table Based on the Laser Tracer Multi-Station Measurement System
This paper proposes a calibration method for angular positioning deviation of a high-precision rotary table based on the laser tracer multi-station measurement system. The algorithm error of the calibration method for angular positioning deviation of a high-precision rotary table based on the laser tracer multi-station measurement system was mainly discussed. During the experiments, the laser tracer was fixed on the work surface of the rotary table, and the rotary was fixed on the work surface of the coordinate measurement machine (CMM). The rotary table was rotated with the same angular interval. In this case, an optimization method for calculating the coordinates of a laser tracer station by using Levenberg–Marquardt algorithm and singular value decomposition transform was proposed. Then, the angular positioning deviation of the rotary table was calibrated by an established geometric relationship model between the coordinates of laser tracer stations and the rotation angle of the rotary table. The angular positioning deviation of the high-precision rotary table was as low as ±0.9″, and the error of the calibration method was ±0.4″. The experimental results proved the feasibility of the proposed calibration method. The calibration method proposed in this paper is suitable for the case that the rotary table is not linked with the CMM, especially for large high-precision rotary tables.
- 19 August 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (16) , 3417
Open AccessCalibration Method for Angular Positioning Deviation of a High-Precision Rotary Table Based on the Laser Tracer Multi-Station Measurement System
This paper proposes a calibration method for angular positioning deviation of a high-precision rotary table based on the laser tracer multi-station measurement system. The algorithm error of the calibration method for angular positioning deviation of a high-precision rotary table based on the laser tracer multi-station measurement system was mainly discussed. During the experiments, the laser tracer was fixed on the work surface of the rotary table, and the rotary was fixed on the work surface of the coordinate measurement machine (CMM). The rotary table was rotated with the same angular interval. In this case, an optimization method for calculating the coordinates of a laser tracer station by using Levenberg–Marquardt algorithm and singular value decomposition transform was proposed. Then, the angular positioning deviation of the rotary table was calibrated by an established geometric relationship model between the coordinates of laser tracer stations and the rotation angle of the rotary table. The angular positioning deviation of the high-precision rotary table was as low as ±0.9″, and the error of the calibration method was ±0.4″. The experimental results proved the feasibility of the proposed calibration method. The calibration method proposed in this paper is suitable for the case that the rotary table is not linked with the CMM, especially for large high-precision rotary tables.