Misin Misini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Misin Misini has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Zijadin Guri
Faculty of Civil Engineering and Architecture University of Prishtina Prishtina Kosovo
3 shared publications - Danilo Ristic
Institute of Earthquake Engineering and Engineering Seismology (IZIIS), Ss. Cyril and Methodius University, 1000 Skopje, North Macedonia
2 shared publications Jelena Ristic
Assistant Professor, Faculty of Engineering, Department of Civil Engineering, International Balkan University, Skopje, Republic of Macedonia
2 shared publications- Nebi Pllana
Faculty of Civil Engineering and Architecture University of Prishtina Prishtina Kosovo
2 shared publications Zijadin Guri
Teaching Assistant, Faculty of Civil Engineering and Architecture, University of Pristina, Kosovo, Albania
2 shared publicationsAssoc Misin Misini
Faculty of Civil Engineering and Architecture University of Prishtina Prishtina Kosovo
1 shared publication
Latest Publications
- 1 August 2021
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Structures and Buildings
- Vol. 174 (8) , 655-669
Upgrading seismically isolated bridges with space-flange energy-dissipation devices
Non-linear three-dimensional analytical models of bridges with laminated-rubber seismic bearing devices upgraded with multi-directional space-flange energy-dissipation (SF-ED) devices were experimentally validated under multi-directional seismic action by shaking table tests of large-scale prototypes. The experimentally verified hysteretic models were used to model the upgraded seismic isolation (USI) system. The seismic protection benefits of the USI were demonstrated through a comparative analysis of bridge prototypes with both standard and upgraded systems. It was confirmed that the SF-ED devices provided a qualitative contribution under very strong earthquakes in all directions. The variation of the structural characteristics of the devices illustrates the technological options for qualitative seismic upgrading of various types of isolated bridges with complex plane geometries under multi-directional seismic actions.
- 1 August 2021
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Structures and Buildings
- Vol. 174 (8) , 655-669
Upgrading seismically isolated bridges with space-flange energy-dissipation devices
Non-linear three-dimensional analytical models of bridges with laminated-rubber seismic bearing devices upgraded with multi-directional space-flange energy-dissipation (SF-ED) devices were experimentally validated under multi-directional seismic action by shaking table tests of large-scale prototypes. The experimentally verified hysteretic models were used to model the upgraded seismic isolation (USI) system. The seismic protection benefits of the USI were demonstrated through a comparative analysis of bridge prototypes with both standard and upgraded systems. It was confirmed that the SF-ED devices provided a qualitative contribution under very strong earthquakes in all directions. The variation of the structural characteristics of the devices illustrates the technological options for qualitative seismic upgrading of various types of isolated bridges with complex plane geometries under multi-directional seismic actions.
- 1 February 2021
- Published by Emerald Publishing in Magazine of Concrete Research
- Vol. 73 (4) , 163-173
Experimental and numerical study of circular columns reinforced with steel and glass FRP bars
Fibre-reinforced polymer (FRP) bars are important replacements for reinforcements made of ordinary steel because the former offer structural durability, electromagnetic neutrality and a high strength/weight ratio, as well as being lightweight and flexible. In the present study, six concrete columns with a diameter of 29·7 cm, a height of 1·5 m but with different percentages of steel and glass FRP bars were tested for endurance under a combination of an axial load and a reversed cyclic bending load up to failure. The experimental and numerical results in terms of force–displacement hysteresis are presented and discussed in this paper. Theoretical analysis was devoted to the refined modelling of the complex hysteretic response of experimentally tested columns with ordinary and composite reinforcement. Finite-element models of the specimens were formulated using a modelling concept of refined fibre sections.
- 1 February 2021
- Published by Emerald Publishing in Magazine of Concrete Research
- Vol. 73 (4) , 163-173
Experimental and numerical study of circular columns reinforced with steel and glass FRP bars
Fibre-reinforced polymer (FRP) bars are important replacements for reinforcements made of ordinary steel because the former offer structural durability, electromagnetic neutrality and a high strength/weight ratio, as well as being lightweight and flexible. In the present study, six concrete columns with a diameter of 29·7 cm, a height of 1·5 m but with different percentages of steel and glass FRP bars were tested for endurance under a combination of an axial load and a reversed cyclic bending load up to failure. The experimental and numerical results in terms of force–displacement hysteresis are presented and discussed in this paper. Theoretical analysis was devoted to the refined modelling of the complex hysteretic response of experimentally tested columns with ordinary and composite reinforcement. Finite-element models of the specimens were formulated using a modelling concept of refined fibre sections.
- Open Access
- 1 May 2019
- Published by Croatian Association of Civil Engineers in Journal of the Croatian Association of Civil Engineers
- Vol. 71 (4) , 255-272
Seismic upgrading of isolated bridges with SF-ED devices: Analytical study validated by shaking table testing
Seismic upgrading of isolated bridges with SF-ED devices: Analytical study validated by shaking table testing A nonlinear 3D analytical model, experimentally validated by seismic shaking table tests of a large-scale bridge model constructed with upgraded seismically isolated system with space flange devices, representing an advanced USI-SF seismic protection system, is presented. Seismic protection advances of USI-SF system are demonstrated through comparative analysis of the model prototype with the proposed new system. Technological options for qualitative upgrading of various types of isolated bridges are made possible with structural generalization of SF-ED devices.
- 1 May 2019
- Published by Croatian Association of Civil Engineers in Journal of the Croatian Association of Civil Engineers
- Vol. 71 (4) , 255-272
Open AccessSeismic upgrading of isolated bridges with SF-ED devices: Analytical study validated by shaking table testing
Seismic upgrading of isolated bridges with SF-ED devices: Analytical study validated by shaking table testing A nonlinear 3D analytical model, experimentally validated by seismic shaking table tests of a large-scale bridge model constructed with upgraded seismically isolated system with space flange devices, representing an advanced USI-SF seismic protection system, is presented. Seismic protection advances of USI-SF system are demonstrated through comparative analysis of the model prototype with the proposed new system. Technological options for qualitative upgrading of various types of isolated bridges are made possible with structural generalization of SF-ED devices.
- Open Access
- 1 July 2018
- Published by Croatian Association of Civil Engineers in Journal of the Croatian Association of Civil Engineers
- Vol. 70 (6) , 463-485
Seismic upgrading of bridges isolated with SF-ED devices: Large-scale model testing on shaking table
- 1 July 2018
- Published by Croatian Association of Civil Engineers in Journal of the Croatian Association of Civil Engineers
- Vol. 70 (6) , 463-485
Open AccessSeismic upgrading of bridges isolated with SF-ED devices: Large-scale model testing on shaking table
- 31 January 2017
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 79 (2)
KOSOVO FLY ASH: UTILIZATION IN CONCRETE AS PARTIAL CEMENT SUBSTITUENT AND THE ENVIRONMENTAL IMPACT
In Kosovo, except electrical energy, thermal power plants (TPP) annually produce more than 1.5 Mt of solid waste: Fly Ash (FA) and Bottom Ash (BA). Kosovo’s construction sector annually consumes around 1 Mt of cement. The environmental impact from cement production (consumption) is the emission of around 1 Mt of CO2. The focus of this study is the utilization of FA in concrete as cement replacement, which will indirectly mitigate the CO2 emissions from cement production. The properties of concrete with FA were investigated. For determining the optimum quantity of FA in concrete, four concrete mixes with different content of class C FA were tested. Density and consistence tests of FA fresh concrete, as well as tests of mechanical properties: compressive, tensile and splitting strength of FA hardened concrete specimens were performed. Concrete resistance to permeability was tested by measuring the depth of water penetration under hydrostatic pressure. The correlation between test results of concrete specimens with FA to reference concrete without FA was done. A 30% cement replacement by fly ash showed experimentally to be reasonable. The environmental benefit would be twofold: indirect decrease of 300,000 t of CO2 and removal of 125,000 m3 of industrial waste (FA).
- 31 January 2017
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 79 (2)
KOSOVO FLY ASH: UTILIZATION IN CONCRETE AS PARTIAL CEMENT SUBSTITUENT AND THE ENVIRONMENTAL IMPACT
In Kosovo, except electrical energy, thermal power plants (TPP) annually produce more than 1.5 Mt of solid waste: Fly Ash (FA) and Bottom Ash (BA). Kosovo’s construction sector annually consumes around 1 Mt of cement. The environmental impact from cement production (consumption) is the emission of around 1 Mt of CO2. The focus of this study is the utilization of FA in concrete as cement replacement, which will indirectly mitigate the CO2 emissions from cement production. The properties of concrete with FA were investigated. For determining the optimum quantity of FA in concrete, four concrete mixes with different content of class C FA were tested. Density and consistence tests of FA fresh concrete, as well as tests of mechanical properties: compressive, tensile and splitting strength of FA hardened concrete specimens were performed. Concrete resistance to permeability was tested by measuring the depth of water penetration under hydrostatic pressure. The correlation between test results of concrete specimens with FA to reference concrete without FA was done. A 30% cement replacement by fly ash showed experimentally to be reasonable. The environmental benefit would be twofold: indirect decrease of 300,000 t of CO2 and removal of 125,000 m3 of industrial waste (FA).
- Open Access
- 8 November 2014
- Published by University for Business and Technology
Evaluation of the Behavior of Flat Slab Systems Subjected to Lateral Loads
. In this paper behavior of flat slab structures under lateral loads, has been evaluated and analyzed. Flat slab structures show more flexibility and lateral displacement of this type of structures are considerable greater comparing to other systems. Nonlinear behavior in the regions near the slabcolumn connection and the change of stiffness in this region needs to be taken into account during the analysis. Slab-column connection characteristics needs to include the potential for punching failure which rise as a function of gravity shear ratio and the interstory drift ratio. Modeling of this type of structures based on effective slab width, which is based in flat slab frame, it describes in the best manner the behavior during lateral loads in sense that pushover and P-delta can be included to the analysis. The theoretical moment distribution from slab to column, and lateral drift in many studies has shown poor agreement with practical results. Ductile properties of the plastic hinges and their prediction of occurrence must be included in analytical model in order to represent the real behavior of this type of structures. Slab shear reinforcement over the columns will avoid the brittle punching shear failure and will provide a necessary strength and ductility to withstand lateral drift during seismic loads. Multi story buildings with flat slabs needs to include shear walls or other stiffer systems to provide good resistance and would limit the inter-story drifts.
- 8 November 2014
- Published by University for Business and Technology
Open AccessEvaluation of the Behavior of Flat Slab Systems Subjected to Lateral Loads
. In this paper behavior of flat slab structures under lateral loads, has been evaluated and analyzed. Flat slab structures show more flexibility and lateral displacement of this type of structures are considerable greater comparing to other systems. Nonlinear behavior in the regions near the slabcolumn connection and the change of stiffness in this region needs to be taken into account during the analysis. Slab-column connection characteristics needs to include the potential for punching failure which rise as a function of gravity shear ratio and the interstory drift ratio. Modeling of this type of structures based on effective slab width, which is based in flat slab frame, it describes in the best manner the behavior during lateral loads in sense that pushover and P-delta can be included to the analysis. The theoretical moment distribution from slab to column, and lateral drift in many studies has shown poor agreement with practical results. Ductile properties of the plastic hinges and their prediction of occurrence must be included in analytical model in order to represent the real behavior of this type of structures. Slab shear reinforcement over the columns will avoid the brittle punching shear failure and will provide a necessary strength and ductility to withstand lateral drift during seismic loads. Multi story buildings with flat slabs needs to include shear walls or other stiffer systems to provide good resistance and would limit the inter-story drifts.