Zhenxing Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhenxing Shen has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Gengkai Hu
Key Laboratory of Dynamics and Control of Flight Vehicle, Ministry of Education, School of Aerospace Engineering, Beijing Institute of Technology, Beijing, China
6 shared publicationsHuijian Li
4 shared publicationsMinggang Wu
3 shared publicationsZhe Ma
3 shared publicationsCheng Liu
2 shared publicationsXiaofeng Xing
Key Laboratory of Mechanical Reliability for Heavy Equipment and Large Structures of Hebei Province, School of Civil Engineering and Mechanics, Yanshan University, Qinhuangdao, China
2 shared publications
Latest Publications
- 12 October 2026
- Published by Elsevier in Composite Structures
- Vol. 399
Mechanical performance enhancement of a compression–torsion chiral metamaterial
- 12 October 2026
- Published by Elsevier in Composite Structures
- Vol. 399
Mechanical performance enhancement of a compression–torsion chiral metamaterial
- 31 January 2026
- Published by Elsevier in Thin-Walled Structures
- Vol. 223
Hierarchical finite beam elements using natural absolute coordinates
- 31 January 2026
- Published by Elsevier in Thin-Walled Structures
- Vol. 223
Hierarchical finite beam elements using natural absolute coordinates
- 18 December 2025
- Published by Elsevier in Composite Structures
- Vol. 379
Thermally induced vibrations of thin-walled composite circular tubes on spacecraft via higher-order ANCF beam elements
- 18 December 2025
- Published by Elsevier in Composite Structures
- Vol. 379
Thermally induced vibrations of thin-walled composite circular tubes on spacecraft via higher-order ANCF beam elements
- 2 October 2025
- Published by Springer Nature in Acta Mechanica
- Vol. 237 (1) , 317-334
On the use of higher-order ANCF beam elements in modeling solid rods with various cross-section configurations
- 2 October 2025
- Published by Springer Nature in Acta Mechanica
- Vol. 237 (1) , 317-334
On the use of higher-order ANCF beam elements in modeling solid rods with various cross-section configurations
- Open Access
A Single-Phase Aluminum-Based Chiral Metamaterial with Simultaneous Negative Mass Density and Bulk Modulus
We propose a single-phase chiral elastic metamaterial capable of simultaneously exhibiting negative effective mass density and negative bulk modulus in the ultrasonic frequency range. The unit cell consists of a regular hexagonal frame connected to a central circular mass through six obliquely oriented, slender aluminum beams. The design avoids the manufacturing complexity of multi-phase systems by relying solely on geometric topology and chirality to induce dipolar and rotational resonances. Dispersion analysis and effective parameter retrieval confirm a double-negative frequency region from 30.9 kHz to 34 kHz. Finite element simulations further demonstrate negative refraction behavior when the metamaterial is immersed in water and subjected to 32 kHz and 32.7 kHz incident plane wave. Equifrequency curves (EFCs) analysis shows excellent agreement with simulated refraction angles, validating the material’s double-negative performance. This study provides a robust, manufacturable platform for elastic wave manipulation using a single-phase metallic metamaterial design.
Open AccessA Single-Phase Aluminum-Based Chiral Metamaterial with Simultaneous Negative Mass Density and Bulk Modulus
We propose a single-phase chiral elastic metamaterial capable of simultaneously exhibiting negative effective mass density and negative bulk modulus in the ultrasonic frequency range. The unit cell consists of a regular hexagonal frame connected to a central circular mass through six obliquely oriented, slender aluminum beams. The design avoids the manufacturing complexity of multi-phase systems by relying solely on geometric topology and chirality to induce dipolar and rotational resonances. Dispersion analysis and effective parameter retrieval confirm a double-negative frequency region from 30.9 kHz to 34 kHz. Finite element simulations further demonstrate negative refraction behavior when the metamaterial is immersed in water and subjected to 32 kHz and 32.7 kHz incident plane wave. Equifrequency curves (EFCs) analysis shows excellent agreement with simulated refraction angles, validating the material’s double-negative performance. This study provides a robust, manufacturable platform for elastic wave manipulation using a single-phase metallic metamaterial design.
- 15 October 2024
- Published by Elsevier in Thin-Walled Structures
- Vol. 205
Cross-sectional zero-dimension temperature model for thin-walled circular tubes in space environment
- 15 October 2024
- Published by Elsevier in Thin-Walled Structures
- Vol. 205
Cross-sectional zero-dimension temperature model for thin-walled circular tubes in space environment
- Open Access
Design of an Automatic Sealing Mechanism for Extraterrestrial Sample-Collecting Robot
Returning extraterrestrial samples to Earth for analysis is crucial for planetary geological research and resource utilization. However, during their return journey, these samples undergo significant environmental changes, such as varying pressure, temperature, impact, and vibration. Hence, a dependable sealing technique that preserves sample integrity without requiring high-powered tools is necessary. This article aims to develop an automatic sealing system for collecting extraterrestrial samples, conducting parametric design and mechanical analysis on two types of proposed sealing structures with minimal sealing force as the benchmark. Additionally, the system will undergo validation through sealing and leakage detection experiments. An automated sealing system, capable of storing samples in multiple sampling tubes, is assembled for the extraterrestrial sampling device.
Open AccessDesign of an Automatic Sealing Mechanism for Extraterrestrial Sample-Collecting Robot
Returning extraterrestrial samples to Earth for analysis is crucial for planetary geological research and resource utilization. However, during their return journey, these samples undergo significant environmental changes, such as varying pressure, temperature, impact, and vibration. Hence, a dependable sealing technique that preserves sample integrity without requiring high-powered tools is necessary. This article aims to develop an automatic sealing system for collecting extraterrestrial samples, conducting parametric design and mechanical analysis on two types of proposed sealing structures with minimal sealing force as the benchmark. Additionally, the system will undergo validation through sealing and leakage detection experiments. An automated sealing system, capable of storing samples in multiple sampling tubes, is assembled for the extraterrestrial sampling device.
- 12 December 2023
- Published by Springer Nature in Multibody System Dynamics
- Vol. 62 (1) , 107-135
Thin-walled composite beam elements via the absolute nodal coordinate formulation
- 12 December 2023
- Published by Springer Nature in Multibody System Dynamics
- Vol. 62 (1) , 107-135
Thin-walled composite beam elements via the absolute nodal coordinate formulation
- 19 May 2023
- Published by Elsevier in Composite Structures
- Vol. 320
Comparison of various thin-walled composite beam models for thermally induced vibrations of spacecraft boom
- 19 May 2023
- Published by Elsevier in Composite Structures
- Vol. 320
Comparison of various thin-walled composite beam models for thermally induced vibrations of spacecraft boom
- 10 December 2022
- Published by Springer Nature in Acta Mechanica
- Vol. 234 (3) , 1259-1273
Thermoelastic–structural dynamics analysis of a satellite with composite thin-walled boom
- 10 December 2022
- Published by Springer Nature in Acta Mechanica
- Vol. 234 (3) , 1259-1273
Thermoelastic–structural dynamics analysis of a satellite with composite thin-walled boom