Andrew Schranck
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew Schranck has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Kela Brathwaite
Case Manager, Love City Strong Inc., 5000 Estate Enighed PMB 435 St. John, VI 00830
5 shared publicationsMandy Lemley
Operations Manager, Love City Strong Inc., 5000 Estate Enighed PMB 435 St. John, VI 00830
5 shared publicationsStephen Libbey
Operations Manager, Love City Strong Inc., 5000 Estate Enighed PMB 435 St. John, VI 00830
5 shared publications- Douglas Momberg
SAMRC/Wits Developmental Pathways for Health Research Unit, Department of Paediatrics and Child Health, School of Clinical Medicine, Faculty of Health Sciences University of the Witwatersrand Soweto South Africa
4 shared publications - Lee Emerson Voth-Gaeddert
Biodesign Center for Health through Microbiomes, Arizona State University, Tempe, AZ 85281, USA
3 shared publications Lee E. Voth-Gaeddert
Honorary Researcher, SAMRC/Wits Developmental Pathways for Health Research Unit, Dept. of Paediatrics and Child Health, School of Clinical Medicine, Faculty of Health Sciences, Univ. of the Witwatersrand, Diepkloof 319-Iq, Soweto 1862, South Africa; Co-Founder, Global Health Engineering, Limited Liability Company, 6809 Alexander St., St. Louis, MO 63116
2 shared publications
Latest Publications
- 1 October 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 149 (10)
Point-of-Entry Ultraviolet Water Treatment Program in the US Virgin Islands: Final Program Results
- 1 October 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 149 (10)
Point-of-Entry Ultraviolet Water Treatment Program in the US Virgin Islands: Final Program Results
- 1 November 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 148 (11) , 06022002
Design and Evaluation of a Household Chlorination System for Treating Cistern Water in the US Virgin Islands
In the US Virgin Islands, of households have rain catchment systems that utilize large cisterns; however, these systems are at high risk of microbial contamination. Available water treatment technologies provide varying levels of protection from microbial contamination and can be expensive. Therefore, we evaluated a low-cost water treatment train that included a passive chlorinator, carbon filter, and membrane filter to provide whole-house treatment for microbial contamination in a mock, pressurized, intermittent-use water system. Two types of locally available passive pool chlorinators were modified and tested for free chlorine residual (FCR) levels across a set of different water use scenarios. Additionally, tracer dye tests were conducted to evaluate chlorine contact time in the system, a carbon filter was evaluated for chlorine removal efficiencies, and a 1-micron nominal filter was evaluated for its effect on system pressure and microbial removal efficiencies. Results suggested the modified passive chlorinators provided relatively consistent chlorine dosing (offline: standard deviation range 0.54 to 0.79 ppm FCR, 3 trials, ; inline: standard deviation 0.53 ppm FCR, 1 trial, ) and tracer dye tests identified a minimum contact time for high flow rates (18.9 LPM, 5 GPM) of . The carbon filter reduced FCR levels from as high as 18.5 ppm to ( ), while the 1-micron nominal filter had negligible effects on system pressure and provided removal of total coliforms ( ). The data suggest that passive chlorination can potentially be a low-cost option for whole-house water treatment for microbial contamination, but further research is needed to demonstrate system stability in a wider range of use cases over a longer period of time along with simplified practitioner protocols for field use.- 1 November 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 148 (11) , 06022002
Design and Evaluation of a Household Chlorination System for Treating Cistern Water in the US Virgin Islands
In the US Virgin Islands, of households have rain catchment systems that utilize large cisterns; however, these systems are at high risk of microbial contamination. Available water treatment technologies provide varying levels of protection from microbial contamination and can be expensive. Therefore, we evaluated a low-cost water treatment train that included a passive chlorinator, carbon filter, and membrane filter to provide whole-house treatment for microbial contamination in a mock, pressurized, intermittent-use water system. Two types of locally available passive pool chlorinators were modified and tested for free chlorine residual (FCR) levels across a set of different water use scenarios. Additionally, tracer dye tests were conducted to evaluate chlorine contact time in the system, a carbon filter was evaluated for chlorine removal efficiencies, and a 1-micron nominal filter was evaluated for its effect on system pressure and microbial removal efficiencies. Results suggested the modified passive chlorinators provided relatively consistent chlorine dosing (offline: standard deviation range 0.54 to 0.79 ppm FCR, 3 trials, ; inline: standard deviation 0.53 ppm FCR, 1 trial, ) and tracer dye tests identified a minimum contact time for high flow rates (18.9 LPM, 5 GPM) of . The carbon filter reduced FCR levels from as high as 18.5 ppm to ( ), while the 1-micron nominal filter had negligible effects on system pressure and provided removal of total coliforms ( ). The data suggest that passive chlorination can potentially be a low-cost option for whole-house water treatment for microbial contamination, but further research is needed to demonstrate system stability in a wider range of use cases over a longer period of time along with simplified practitioner protocols for field use.- Open Access
Evaluating the Effectiveness of Point-of-Entry UV Treatment for Cistern Water Among Households in the US Virgin Islands
UV water treatment can be a viable option for point-of-entry applications among households utilizing private water sources. In the US Virgin Islands (USVI), the primary water source is roof-harvested rainwater, collected in large cisterns and supplied to household taps via a pump. While diversification of water sources provides increased resilience to climate change, literature suggests rainwater catchment systems are at high risk of microbial contamination. One option USVI households have is UV systems. However, limited data is available on UV system effectiveness for USVI installations while these systems can be expensive. Therefore, Love City Strong, a local NGO, piloted a multi-year UV access program which included free UV systems with prefiltration along with installation and monthly household visits for up to 12 months including water quality testing. In addition, due to the significant costs associated with the prefiltration portion of the system, a pilot study was conducted to evaluate the effectiveness of the UV systems without prefiltration. The results from the UV system access program demonstrated that E. coli was not detected in 95.2% of tap samples (n=271). Among samples with detectable levels of E. coli and total coliforms, turbidity was lower compared to samples with non-detections. Field teams reported user error was often identified in association with E. coli detections (e.g., bypass was opened). Among all samples from the pilot study of UV systems without prefiltration, no E. coli was detected (n=24). Total first-year costs for locally available UV systems with and without prefiltration ranged from $1,059-$1,645 and $927-$1,183, respectively, while operation and maintenance (O& M) costs ranged from $166-$266 and $142-$146, respectively. Given these data, UV systems may be a viable option for generating potable water; however, clear purchasing and installation protocols are needed as well as simple O&M guidelines for households to reduce user error. Synopsis: Point-of-entry UV systems were able to produce water for domestic use with no detectable E. coli in 95.2% of samples among USVI households using roof-harvested rainwater.
Open AccessEvaluating the Effectiveness of Point-of-Entry UV Treatment for Cistern Water Among Households in the US Virgin Islands
UV water treatment can be a viable option for point-of-entry applications among households utilizing private water sources. In the US Virgin Islands (USVI), the primary water source is roof-harvested rainwater, collected in large cisterns and supplied to household taps via a pump. While diversification of water sources provides increased resilience to climate change, literature suggests rainwater catchment systems are at high risk of microbial contamination. One option USVI households have is UV systems. However, limited data is available on UV system effectiveness for USVI installations while these systems can be expensive. Therefore, Love City Strong, a local NGO, piloted a multi-year UV access program which included free UV systems with prefiltration along with installation and monthly household visits for up to 12 months including water quality testing. In addition, due to the significant costs associated with the prefiltration portion of the system, a pilot study was conducted to evaluate the effectiveness of the UV systems without prefiltration. The results from the UV system access program demonstrated that E. coli was not detected in 95.2% of tap samples (n=271). Among samples with detectable levels of E. coli and total coliforms, turbidity was lower compared to samples with non-detections. Field teams reported user error was often identified in association with E. coli detections (e.g., bypass was opened). Among all samples from the pilot study of UV systems without prefiltration, no E. coli was detected (n=24). Total first-year costs for locally available UV systems with and without prefiltration ranged from $1,059-$1,645 and $927-$1,183, respectively, while operation and maintenance (O& M) costs ranged from $166-$266 and $142-$146, respectively. Given these data, UV systems may be a viable option for generating potable water; however, clear purchasing and installation protocols are needed as well as simple O&M guidelines for households to reduce user error. Synopsis: Point-of-entry UV systems were able to produce water for domestic use with no detectable E. coli in 95.2% of samples among USVI households using roof-harvested rainwater.
- 1 October 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 148 (10) , 04022063
Evaluating a Large-Scale Batch Chlorination Method for Household Cistern Water Treatment in the US Virgin Islands
In the US Virgin Islands (USVI), roof-harvested rainwater is a primary source of domestic water and is collected in large cisterns and pumped throughout the household premise plumbing system. However, previous literature suggests that roof-harvest rainwater is prone to microbial contamination. A common local water treatment practice is direct batch chlorination of this water ( L). Provided this local habit, Love City Strong (LCS) established a pilot program to evaluate if direct batch chlorination of water in cisterns was effective and economically feasible to produce consistently adequate levels of free chlorine residual (FCR) at the kitchen tap. A trained field team utilized nine actively used cisterns to conduct a series of chlorine dosing trials where the cistern water was dosed, and, subsequently, monitored every three days. Water quality data were collected throughout, and new trials were initiated once FCR values reached . Evaluation criteria included: (1) the variability in duration between a dosing event and an FCR measurement , (2) the variability of achieving a target FCR level of 1.5 ppm, (3) the variability in the first-order chlorine decay rate, and (4) the costs of the method. Results suggested that the variability in duration, achieving a target FCR, and the decay rate were prohibitively high for consistent use of the method. The duration ranged from 3 to 33 days (mean: 11.5; ). This large range may have been influenced by the low probability (18%) of achieving an initial target FCR between 1.25 and 1.75 ppm. In addition, the chlorine decay rate ranged from 0.095 to (mean: ), resulting in an estimated duration ranging between 5 and 22 days. Finally, the first-year cost was $622 ($244 excluding person-time costs), while annual costs thereafter were $567 ($204 excluding person-time costs). Given these data, we do not recommend the use of direct batch chlorination for treating cistern water for microbial contamination in USVI households.- 1 October 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 148 (10) , 04022063
Evaluating a Large-Scale Batch Chlorination Method for Household Cistern Water Treatment in the US Virgin Islands
In the US Virgin Islands (USVI), roof-harvested rainwater is a primary source of domestic water and is collected in large cisterns and pumped throughout the household premise plumbing system. However, previous literature suggests that roof-harvest rainwater is prone to microbial contamination. A common local water treatment practice is direct batch chlorination of this water ( L). Provided this local habit, Love City Strong (LCS) established a pilot program to evaluate if direct batch chlorination of water in cisterns was effective and economically feasible to produce consistently adequate levels of free chlorine residual (FCR) at the kitchen tap. A trained field team utilized nine actively used cisterns to conduct a series of chlorine dosing trials where the cistern water was dosed, and, subsequently, monitored every three days. Water quality data were collected throughout, and new trials were initiated once FCR values reached . Evaluation criteria included: (1) the variability in duration between a dosing event and an FCR measurement , (2) the variability of achieving a target FCR level of 1.5 ppm, (3) the variability in the first-order chlorine decay rate, and (4) the costs of the method. Results suggested that the variability in duration, achieving a target FCR, and the decay rate were prohibitively high for consistent use of the method. The duration ranged from 3 to 33 days (mean: 11.5; ). This large range may have been influenced by the low probability (18%) of achieving an initial target FCR between 1.25 and 1.75 ppm. In addition, the chlorine decay rate ranged from 0.095 to (mean: ), resulting in an estimated duration ranging between 5 and 22 days. Finally, the first-year cost was $622 ($244 excluding person-time costs), while annual costs thereafter were $567 ($204 excluding person-time costs). Given these data, we do not recommend the use of direct batch chlorination for treating cistern water for microbial contamination in USVI households.- Open Access
- 29 September 2022
- Published by IWA Publishing in Water Policy
- Vol. 24 (10) , 1692-1703
Evaluating the costs and components of a territory-wide household water storage and treatment program in the US Virgin Islands
Among island communities, water security and access continue to be a critical issue. In the US Virgin Islands (USVI), 90% of households are capable of collecting roof-harvested rainwater, whereas less than 25% of households are connected to a municipal water system serviced by desalination plants. Rainwater collection leaves the household in charge of managing and treating their own water. Therefore, understanding current barriers to accessing water treatment technologies and the costs of a water storage and treatment program at scale are critical in developing a territory-wide program. In this study, we evaluate (1) household-level barriers to accessing water treatment technologies, (2) a cost breakdown of a UV water treatment pilot program, and (3) potential estimates of program costs at a territory-wide scale. The results suggest that for households, key barriers include knowledge of the problem or solution and capital and installation costs. From the programmatic cost evaluation, the water treatment technology and water testing services were the most expensive. However, given key adjustments, a territory-wide program is estimated to cost $30.4 M covering 50% of households. These data can be used by a coalition of stakeholders in allocating financial and managerial responsibility for a territory-wide water storage and treatment program in USVI.
- 29 September 2022
- Published by IWA Publishing in Water Policy
- Vol. 24 (10) , 1692-1703
Open AccessEvaluating the costs and components of a territory-wide household water storage and treatment program in the US Virgin Islands
Among island communities, water security and access continue to be a critical issue. In the US Virgin Islands (USVI), 90% of households are capable of collecting roof-harvested rainwater, whereas less than 25% of households are connected to a municipal water system serviced by desalination plants. Rainwater collection leaves the household in charge of managing and treating their own water. Therefore, understanding current barriers to accessing water treatment technologies and the costs of a water storage and treatment program at scale are critical in developing a territory-wide program. In this study, we evaluate (1) household-level barriers to accessing water treatment technologies, (2) a cost breakdown of a UV water treatment pilot program, and (3) potential estimates of program costs at a territory-wide scale. The results suggest that for households, key barriers include knowledge of the problem or solution and capital and installation costs. From the programmatic cost evaluation, the water treatment technology and water testing services were the most expensive. However, given key adjustments, a territory-wide program is estimated to cost $30.4 M covering 50% of households. These data can be used by a coalition of stakeholders in allocating financial and managerial responsibility for a territory-wide water storage and treatment program in USVI.
- 14 June 2018
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 52 (15) , 8638-8648
Effect of Urine Compounds on the Electrochemical Oxidation of Urea Using a Nickel Cobaltite Catalyst: An Electroanalytical and Spectroscopic Investigation
Cyclic voltammetry (CV) and in-situ attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy were used to investigate the effect of major urine compounds on the electrooxidation activity of urea using a nickel cobaltite (NiCo2O4) catalyst. As a substrate, carbon paper exhibited better benchmark potential and current values compared to stainless steel and fluorine-doped tin oxide glass, which was attributed to its greater active surface area per electrode geometric area. CV analysis of a synthetic urine showed that phosphate, creatinine, and gelatin (i.e., proteins) had the most negative effect on the electrooxidation activity of urea with decreases in peak current up to 80% compared to a urea-only solution. Further investigation on the binding mechanisms of the deleterious compounds using in-situ ATR-FTIR spectroscopy revealed that urea and phosphate weakly bind to NiCo2O4 through hydrogen bonding or long-range forces, whereas creatinine interacts strongly, forming deactivating inner-sphere complexes. Phosphate is presumed to disrupt the interaction between urea and NiCo2O4 by serving as a hydrogen bond acceptor in place of catalyst sites. Weak binding of urea supports the hypothesis that it is oxidized through an indirect electron transfer. Outcomes of this study contribute to the development of electrolytic systems for treating source-separated urine.
- 14 June 2018
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 52 (15) , 8638-8648
Effect of Urine Compounds on the Electrochemical Oxidation of Urea Using a Nickel Cobaltite Catalyst: An Electroanalytical and Spectroscopic Investigation
Cyclic voltammetry (CV) and in-situ attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy were used to investigate the effect of major urine compounds on the electrooxidation activity of urea using a nickel cobaltite (NiCo2O4) catalyst. As a substrate, carbon paper exhibited better benchmark potential and current values compared to stainless steel and fluorine-doped tin oxide glass, which was attributed to its greater active surface area per electrode geometric area. CV analysis of a synthetic urine showed that phosphate, creatinine, and gelatin (i.e., proteins) had the most negative effect on the electrooxidation activity of urea with decreases in peak current up to 80% compared to a urea-only solution. Further investigation on the binding mechanisms of the deleterious compounds using in-situ ATR-FTIR spectroscopy revealed that urea and phosphate weakly bind to NiCo2O4 through hydrogen bonding or long-range forces, whereas creatinine interacts strongly, forming deactivating inner-sphere complexes. Phosphate is presumed to disrupt the interaction between urea and NiCo2O4 by serving as a hydrogen bond acceptor in place of catalyst sites. Weak binding of urea supports the hypothesis that it is oxidized through an indirect electron transfer. Outcomes of this study contribute to the development of electrolytic systems for treating source-separated urine.