Ganggang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ganggang Zhang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Weihua Lai
Nanchang University
3 shared publications - Xiaocui Lai
State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
3 shared publications Liu Su
Institute of Microbiology, Jiangxi Academy of Sciences, 7777 Changdong Avenue, Nanchang 330096, China
2 shared publications- Shengliang Deng
Institute of Microbiology, Jiangxi Academy of Sciences, Nanchang 330096, China
2 shared publications Weihua He
Institute of Microbiology, Jiangxi Academy of Sciences, 7777 Changdong Avenue, Nanchang 330096, China
2 shared publications- Bolong Fang
State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
1 shared publication
Latest Publications
- 2 June 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (14) , 3207-3216
High-flux smartphone-integrated lateral flow assay based on chrysanthemum-like Au@polydopamine for sensitive detection of enrofloxacin in milk
Lateral flow assays (LFAs) are widely used in screening analysis. However, the detection flux and sensitivity of LFAs are unsatisfactory because of the ‘one-to-one’ read mode and the ordinary performance conventional probe. In this work, a high-flux smartphone-integrated LFA (sLFA) based on chrysanthemum-like Au@polydopamine (AuNC@PDA) for the detection of enrofloxacin (ENR) in milk was established. The smartphone-integrated device was developed and applied in the LFA, giving rise to a reading maximum of 64 samples with only two photos in less than 2 min compared to a ‘one-to-one’ read mode of a conventional LFA in more than 14 min with a 36.4% deviation. For ENR detection, the limits of detection of sLFA based on AuNC@PDA (33.78 pg mL−1) had 5.0-fold and 6.4-fold reduction compared with those based on AuNP (169.99 pg mL−1, conventional probe) and vvAuNP (216.47 pg mL−1, commercial probe), respectively. This study provides an effective technical means for screening ENR in large quantities of milk samples.
- 2 June 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (14) , 3207-3216
High-flux smartphone-integrated lateral flow assay based on chrysanthemum-like Au@polydopamine for sensitive detection of enrofloxacin in milk
Lateral flow assays (LFAs) are widely used in screening analysis. However, the detection flux and sensitivity of LFAs are unsatisfactory because of the ‘one-to-one’ read mode and the ordinary performance conventional probe. In this work, a high-flux smartphone-integrated LFA (sLFA) based on chrysanthemum-like Au@polydopamine (AuNC@PDA) for the detection of enrofloxacin (ENR) in milk was established. The smartphone-integrated device was developed and applied in the LFA, giving rise to a reading maximum of 64 samples with only two photos in less than 2 min compared to a ‘one-to-one’ read mode of a conventional LFA in more than 14 min with a 36.4% deviation. For ENR detection, the limits of detection of sLFA based on AuNC@PDA (33.78 pg mL−1) had 5.0-fold and 6.4-fold reduction compared with those based on AuNP (169.99 pg mL−1, conventional probe) and vvAuNP (216.47 pg mL−1, commercial probe), respectively. This study provides an effective technical means for screening ENR in large quantities of milk samples.
- 24 April 2023
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 35 (9) , 3494-3502
Highly Sensitive and Ultrastable Lateral Flow Immunoassay Based on Polydopamine-Coated Aggregation-Induced Emission Fluorescent Microspheres with Excellent Fluorescence Performance and Biofriendly Coupling Strategy
- 24 April 2023
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 35 (9) , 3494-3502
Highly Sensitive and Ultrastable Lateral Flow Immunoassay Based on Polydopamine-Coated Aggregation-Induced Emission Fluorescent Microspheres with Excellent Fluorescence Performance and Biofriendly Coupling Strategy
- 21 December 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 13 (1) , 1413-1423
Synthesis of PDA-Mediated Magnetic Bimetallic Nanozyme and Its Application in Immunochromatographic Assay
Immunochromatographic assay (ICA) is widely applied in various fields. However, severe matrix interference and weak signal output present major challenges in achieving accurate and ultrasensitive detection in ICA. Here, a polydopamine (PDA)-mediated magnetic bimetallic nanozyme (Fe3O4@[email protected]/Pt) with peroxidase-like activity was synthesized and used as a probe in ICA. The magnetic property of Fe3O4@[email protected]/Pt enabled effective magnetic enrichment of targets, thereby reducing the matrix interference in the sample. PDA coating on the magnetic bimetallic nanozyme was employed as a mediator and a stabilizer. It improved the catalytic ability and stability of the magnetic bimetallic nanozyme by providing more coordination sites for Pd/Pt growth and functional groups (−NH and −OH). In addition, the Pd/Pt bimetallic synergistic effect could further enhance the catalytic ability of the nanozyme. A method was developed by integrating Fe3O4, PDA, and Pd/Pt into Fe3O4@[email protected]/Pt as a probe in ICA. With the proposed method, human chorionic gonadotropin and Escherichia coli O157:H7 were successfully detected to be as low as 0.0094 mIU/mL in human blood serum and 9 × 101 CFU/mL in the milk sample, respectively. This method may be readily adapted for accurate and ultrasensitive detection of other biomolecules in various fields.
- 21 December 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 13 (1) , 1413-1423
Synthesis of PDA-Mediated Magnetic Bimetallic Nanozyme and Its Application in Immunochromatographic Assay
Immunochromatographic assay (ICA) is widely applied in various fields. However, severe matrix interference and weak signal output present major challenges in achieving accurate and ultrasensitive detection in ICA. Here, a polydopamine (PDA)-mediated magnetic bimetallic nanozyme (Fe3O4@[email protected]/Pt) with peroxidase-like activity was synthesized and used as a probe in ICA. The magnetic property of Fe3O4@[email protected]/Pt enabled effective magnetic enrichment of targets, thereby reducing the matrix interference in the sample. PDA coating on the magnetic bimetallic nanozyme was employed as a mediator and a stabilizer. It improved the catalytic ability and stability of the magnetic bimetallic nanozyme by providing more coordination sites for Pd/Pt growth and functional groups (−NH and −OH). In addition, the Pd/Pt bimetallic synergistic effect could further enhance the catalytic ability of the nanozyme. A method was developed by integrating Fe3O4, PDA, and Pd/Pt into Fe3O4@[email protected]/Pt as a probe in ICA. With the proposed method, human chorionic gonadotropin and Escherichia coli O157:H7 were successfully detected to be as low as 0.0094 mIU/mL in human blood serum and 9 × 101 CFU/mL in the milk sample, respectively. This method may be readily adapted for accurate and ultrasensitive detection of other biomolecules in various fields.
- 7 August 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (34) , 31283-31290
Lateral Flow Immunoassay Based on Polydopamine-Coated Gold Nanoparticles for the Sensitive Detection of Zearalenone in Maize
In this work, polydopamine-coated gold nanoparticles ([email protected]) were synthesized by the oxidative self-polymerization of dopamine (DA) on the surface of AuNPs and applied for the first time as a signal-amplification label in lateral flow immunoassays (LFIAs) for the sensitive detection of zearalenone (ZEN) in maize. The PDA layer functioned as a linker between AuNPs and anti-ZEN monoclonal antibody (mAb) to form a probe ([email protected]). Compared with AuNPs, [email protected] had excellent color intensity, colloidal stability, and mAb coupling efficiency. The limit of detection of the [email protected] LFIA ([email protected]) was 7.4 pg/mL, which was 10-fold lower than that of the traditional AuNP-based LFIA (AuNP-LFIA) (76.1 pg/mL). The recoveries of [email protected] were 93.80–111.82%, with the coefficient of variation of 1.08–9.04%. In addition, the reliability of [email protected] was further confirmed by the high-performance liquid chromatography method. Overall, our study showed that PDA coating can chemically modify the surface of AuNPs through a simple method and can thus significantly improve the detection sensitivity of LFIA.
- 7 August 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (34) , 31283-31290
Lateral Flow Immunoassay Based on Polydopamine-Coated Gold Nanoparticles for the Sensitive Detection of Zearalenone in Maize
In this work, polydopamine-coated gold nanoparticles ([email protected]) were synthesized by the oxidative self-polymerization of dopamine (DA) on the surface of AuNPs and applied for the first time as a signal-amplification label in lateral flow immunoassays (LFIAs) for the sensitive detection of zearalenone (ZEN) in maize. The PDA layer functioned as a linker between AuNPs and anti-ZEN monoclonal antibody (mAb) to form a probe ([email protected]). Compared with AuNPs, [email protected] had excellent color intensity, colloidal stability, and mAb coupling efficiency. The limit of detection of the [email protected] LFIA ([email protected]) was 7.4 pg/mL, which was 10-fold lower than that of the traditional AuNP-based LFIA (AuNP-LFIA) (76.1 pg/mL). The recoveries of [email protected] were 93.80–111.82%, with the coefficient of variation of 1.08–9.04%. In addition, the reliability of [email protected] was further confirmed by the high-performance liquid chromatography method. Overall, our study showed that PDA coating can chemically modify the surface of AuNPs through a simple method and can thus significantly improve the detection sensitivity of LFIA.
- 1 October 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21627541,p. 379-382
SCR-type ESD protection circuit for RFICs
A novel SCR-type ESD protection circuit for RFICs is proposed, which have a good ESD level above 5kV, a low leakage current below 5pA, a low capacitive loading, and a low latch-up risk.
- 1 October 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21627541,p. 379-382
SCR-type ESD protection circuit for RFICs
A novel SCR-type ESD protection circuit for RFICs is proposed, which have a good ESD level above 5kV, a low leakage current below 5pA, a low capacitive loading, and a low latch-up risk.