John J. Pitre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
John J. Pitre has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Ivan Pelivanov
University of Washington
4 shared publications - Matthew O'DOnnell
Department of Bioengineering, University of Washington, 3720 15th Ave NE, Seattle, Wa 98195, USA
4 shared publications Ruikang K. Wang
Department of Bioengineering, University of Washington, Seattle, WA, USA
4 shared publications- David Shicheng Li
Univ. of Washington
3 shared publications - Tueng T. Shen
Department of Ophthalmology, University of Washington, Seattle, USA
3 shared publications - Liang Gao
Department of Bioengineering, University of Washington 1 , Seattle, Washington 98195, USA
2 shared publications
Latest Publications
- Open Access
- 31 July 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-14
Nearly-incompressible transverse isotropy (NITI) of cornea elasticity: model and experiments with acoustic micro-tapping OCE
The cornea provides the largest refractive power for the human visual system. Its stiffness, along with intraocular pressure (IOP), are linked to several pathologies, including keratoconus and glaucoma. Although mechanical tests can quantify corneal elasticity ex vivo, they cannot be used clinically. Dynamic optical coherence elastography (OCE), which launches and tracks shear waves to estimate stiffness, provides an attractive non-contact probe of corneal elasticity. To date, however, OCE studies report corneal moduli around tens of kPa, orders-of-magnitude less than those (few MPa) obtained by tensile/inflation testing. This large discrepancy impedes OCE’s clinical adoption. Based on corneal microstructure, we introduce and fully characterize a nearly-incompressible transversely isotropic (NITI) model depicting corneal biomechanics. We show that the cornea must be described by at least two shear moduli, contrary to current single-modulus models, decoupling tensile and shear responses. We measure both as a function of IOP in ex vivo porcine cornea, obtaining values consistent with both tensile and shear tests. At pressures above 30 mmHg, the model begins to fail, consistent with non-linear changes in cornea at high IOP.
- 31 July 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-14
Open AccessNearly-incompressible transverse isotropy (NITI) of cornea elasticity: model and experiments with acoustic micro-tapping OCE
The cornea provides the largest refractive power for the human visual system. Its stiffness, along with intraocular pressure (IOP), are linked to several pathologies, including keratoconus and glaucoma. Although mechanical tests can quantify corneal elasticity ex vivo, they cannot be used clinically. Dynamic optical coherence elastography (OCE), which launches and tracks shear waves to estimate stiffness, provides an attractive non-contact probe of corneal elasticity. To date, however, OCE studies report corneal moduli around tens of kPa, orders-of-magnitude less than those (few MPa) obtained by tensile/inflation testing. This large discrepancy impedes OCE’s clinical adoption. Based on corneal microstructure, we introduce and fully characterize a nearly-incompressible transversely isotropic (NITI) model depicting corneal biomechanics. We show that the cornea must be described by at least two shear moduli, contrary to current single-modulus models, decoupling tensile and shear responses. We measure both as a function of IOP in ex vivo porcine cornea, obtaining values consistent with both tensile and shear tests. At pressures above 30 mmHg, the model begins to fail, consistent with non-linear changes in cornea at high IOP.
- Open Access
- 23 December 2019
- Published by Cold Spring Harbor Laboratory in bioRxiv
Real-time spectroscopic photoacoustic/ultrasound (PAUS) scanning with simultaneous fluence compensation and motion correction for quantitative molecular imaging
For over two decades photoacoustic (PA) imaging has been tested clinically, but successful human trials have been minimal. To enable quantitative clinical spectroscopy, the fundamental issues of wavelength-dependent fluence variations and inter-wavelength motion must be overcome. Here we propose a new real-time, spectroscopic photoacoustic/ultrasound (PAUS) imaging approach using a compact, 1-kHz rate wavelength-tunable laser. Instead of illuminating tissue over a large area, the fiber-optic delivery system surrounding an US array sequentially scans a narrow laser beam, with partial PA image reconstruction for each laser pulse. The final image is then formed by coherently summing partial images at a 50-Hz video rate. This scheme enables (i) automatic laser-fluence compensation in spectroscopic PA imaging and (ii) inter-wavelength motion correction using US speckle tracking, which have never been shown before in real-time systems. The 50-Hz video rate PAUS system is demonstrated in vivo using a murine model of drug delivery monitoring.
- 23 December 2019
- Published by Cold Spring Harbor Laboratory in bioRxiv
Open AccessReal-time spectroscopic photoacoustic/ultrasound (PAUS) scanning with simultaneous fluence compensation and motion correction for quantitative molecular imaging
For over two decades photoacoustic (PA) imaging has been tested clinically, but successful human trials have been minimal. To enable quantitative clinical spectroscopy, the fundamental issues of wavelength-dependent fluence variations and inter-wavelength motion must be overcome. Here we propose a new real-time, spectroscopic photoacoustic/ultrasound (PAUS) imaging approach using a compact, 1-kHz rate wavelength-tunable laser. Instead of illuminating tissue over a large area, the fiber-optic delivery system surrounding an US array sequentially scans a narrow laser beam, with partial PA image reconstruction for each laser pulse. The final image is then formed by coherently summing partial images at a 50-Hz video rate. This scheme enables (i) automatic laser-fluence compensation in spectroscopic PA imaging and (ii) inter-wavelength motion correction using US speckle tracking, which have never been shown before in real-time systems. The 50-Hz video rate PAUS system is demonstrated in vivo using a murine model of drug delivery monitoring.
- Open Access
- 18 September 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (09) , 096006-16
Spatial resolution in dynamic optical coherence elastography
Optical coherence elastography (OCE) uses optical coherence tomography (OCT) to detect local tissue displacement following an applied force, enabling the quantification of biomechanical properties within a region of interest. OCE can potentially identify pathologies opaque to classical OCT using local maps of tissue mechanical properties (namely Young’s modulus), which can vary greatly between healthy and disease states. Detecting spatial heterogeneities in a mechanical structure can help monitor and treat disease progression in numerous fields, including ophthalmology,1 – 5 dermatology,6 cardiology,7 gastroenterology,8 and oncology.9 – 11 While it is a general belief that dynamic OCE is capable of high-resolution (on the order of the imaging modality, OCT) mapping of tissue mechanical properties, the spatial resolution in wave-based optical elastography has not yet been characterized.
- 18 September 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (09) , 096006-16
Open AccessSpatial resolution in dynamic optical coherence elastography
Optical coherence elastography (OCE) uses optical coherence tomography (OCT) to detect local tissue displacement following an applied force, enabling the quantification of biomechanical properties within a region of interest. OCE can potentially identify pathologies opaque to classical OCT using local maps of tissue mechanical properties (namely Young’s modulus), which can vary greatly between healthy and disease states. Detecting spatial heterogeneities in a mechanical structure can help monitor and treat disease progression in numerous fields, including ophthalmology,1 – 5 dermatology,6 cardiology,7 gastroenterology,8 and oncology.9 – 11 While it is a general belief that dynamic OCE is capable of high-resolution (on the order of the imaging modality, OCT) mapping of tissue mechanical properties, the spatial resolution in wave-based optical elastography has not yet been characterized.
- 19 August 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 115 (8) , 083701
Super-shear evanescent waves for non-contact elastography of soft tissues
We describe surface wave propagation in soft elastic media at speeds exceeding the bulk shear wave speed. By linking these waves to the elastodynamic Green's function, we derive a simple relationship to quantify the elasticity of a soft medium from the speed of this supershear evanescent wave (SEW). We experimentally probe SEW propagation in tissue-mimicking phantoms, human cornea ex vivo, and skin in vivo using a high-speed optical coherence elastography system. Measurements confirm the predicted relationship between SEW and bulk shear wave speeds, agreeing well with both theoretical and numerical models. These results suggest that SEW measurements may be a robust method to quantify elasticity in soft media, particularly in complex, bounded materials where dispersive Rayleigh-Lamb modes complicate measurements.
- 19 August 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 115 (8) , 083701
Super-shear evanescent waves for non-contact elastography of soft tissues
We describe surface wave propagation in soft elastic media at speeds exceeding the bulk shear wave speed. By linking these waves to the elastodynamic Green's function, we derive a simple relationship to quantify the elasticity of a soft medium from the speed of this supershear evanescent wave (SEW). We experimentally probe SEW propagation in tissue-mimicking phantoms, human cornea ex vivo, and skin in vivo using a high-speed optical coherence elastography system. Measurements confirm the predicted relationship between SEW and bulk shear wave speeds, agreeing well with both theoretical and numerical models. These results suggest that SEW measurements may be a robust method to quantify elasticity in soft media, particularly in complex, bounded materials where dispersive Rayleigh-Lamb modes complicate measurements.
- Open Access
- 24 July 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (07) , 1-11
Does group velocity always reflect elastic modulus in shear wave elastography?
Dynamic elastography is an attractive method to evaluate tissue biomechanical properties. Recently, it was extended from US- and MR-based modalities to optical ones, such as optical coherence tomography for three-dimensional (3-D) imaging of propagating mechanical waves in subsurface regions of soft tissues, such as the eye. The measured group velocity is often used to convert wave speed maps into 3-D images of the elastic modulus distribution based on the assumption of bulk shear waves. However, the specific geometry of OCE measurements in bounded materials such as the cornea and skin calls into question elasticity reconstruction assuming a simple relationship between group velocity and shear modulus. We show that in layered media the bulk shear wave assumption results in highly underestimated shear modulus reconstructions and significant structural artifacts in modulus images. We urge the OCE community to be careful in using the group velocity to evaluate tissue elasticity and to focus on developing robust reconstruction methods to accurately reconstruct images of the shear elastic modulus in bounded media.
- 24 July 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (07) , 1-11
Open AccessDoes group velocity always reflect elastic modulus in shear wave elastography?
Dynamic elastography is an attractive method to evaluate tissue biomechanical properties. Recently, it was extended from US- and MR-based modalities to optical ones, such as optical coherence tomography for three-dimensional (3-D) imaging of propagating mechanical waves in subsurface regions of soft tissues, such as the eye. The measured group velocity is often used to convert wave speed maps into 3-D images of the elastic modulus distribution based on the assumption of bulk shear waves. However, the specific geometry of OCE measurements in bounded materials such as the cornea and skin calls into question elasticity reconstruction assuming a simple relationship between group velocity and shear modulus. We show that in layered media the bulk shear wave assumption results in highly underestimated shear modulus reconstructions and significant structural artifacts in modulus images. We urge the OCE community to be careful in using the group velocity to evaluate tissue elasticity and to focus on developing robust reconstruction methods to accurately reconstruct images of the shear elastic modulus in bounded media.