Oliver Löhmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Oliver Löhmann has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Regine von Klitzing
Soft Matter at Interfaces, Department of Physics, Technische Universität Darmstadt, Darmstadt, Germany
11 shared publications - Henrich Frielinghaus
Jülich Centre for Neutron Science JCNS at MLZ, Forschungszentrum Jülich GmbH, 85748 Garching, Germany
4 shared publications - Matthias Kühnhammer
Institut für Physik Kondensierter Materie, Technische Universität Darmstadt, Hochschulstraße 8, 64289 Darmstadt, Germany
4 shared publications - Arno Hiess
Institut Laue-Langevin 71 avenue des Martyrs CS 20156 38042 Grenoble CEDEX 9 France
3 shared publications - Emanuel Schneck
Soft Matter Biophysics, Institute for Condensed Matter Physics
3 shared publications - Harald Schneider
European Spallation Source ERIC, P.O. Box 176, SE-221 00 Lund, Sweden
3 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Wiley in Advanced Energy Materials
- Vol. 16 (40) , e71554
Multi‐modal Operando Analysis of Lithium–Sulfur Batteries: A Comparative Study on the Influence of Electrolyte Composition
The effect of electrolytes on battery cell performance is multifaceted, and it is difficult to isolate their impact on individual processes. Operando analysis of batteries is a powerful tool to investigate battery degradation mechanisms. By combining different techniques on the same cell a wider perspective can be opened and enables easier cross‐correlation. Here, we introduce a fully laboratory‐based multimodal operando platform that synchronizes EIS/DRT, Raman spectroscopy, UV–vis reflectance spectroscopy, temperature monitoring, and galvanostatic cycling in one sealed Li–S cell. The platform is demonstrated over an extended observation window of up to 20 cycles to compare electrolyte‐dependent polysulfide speciation, transport limitations, and resistance evolution. The experimental design is optimized for reproducible mechanistic characterization and is not intended as a benchmark of practical cell performance or long‐term cycle life.
- 21 September 2026
- Published by Wiley in Advanced Energy Materials
- Vol. 16 (40) , e71554
Open AccessMulti‐modal Operando Analysis of Lithium–Sulfur Batteries: A Comparative Study on the Influence of Electrolyte Composition
The effect of electrolytes on battery cell performance is multifaceted, and it is difficult to isolate their impact on individual processes. Operando analysis of batteries is a powerful tool to investigate battery degradation mechanisms. By combining different techniques on the same cell a wider perspective can be opened and enables easier cross‐correlation. Here, we introduce a fully laboratory‐based multimodal operando platform that synchronizes EIS/DRT, Raman spectroscopy, UV–vis reflectance spectroscopy, temperature monitoring, and galvanostatic cycling in one sealed Li–S cell. The platform is demonstrated over an extended observation window of up to 20 cycles to compare electrolyte‐dependent polysulfide speciation, transport limitations, and resistance evolution. The experimental design is optimized for reproducible mechanistic characterization and is not intended as a benchmark of practical cell performance or long‐term cycle life.
- Open Access
- 7 September 2023
- Published by TIB Open Publishing in Proceedings of the Conference on Research Data Infrastructure
- Vol. 1
BAM Data Store
As a partner in several NFDI consortia, the Bundesanstalt für Materialforschung und -prüfung (BAM, German federal institute for materials science and testing) contributes to research data standardization efforts in various domains of materials science and engineering (MSE). To implement a central research data management (RDM) infrastructure that meets the requirements of MSE groups at BAM, we initiated the Data Store pilot project in 2021. The resulting infrastructure should enable researchers to digitally document research processes and store related data in a standardized and interoperable manner. As a software solution, we chose openBIS, an open-source framework that is increasingly being used for RDM in MSE communities. The pilot project was conducted for one year with five research groups across different organizational units and MSE disciplines. The main results are presented for the use case “nanoPlattform”. The group registered experimental steps and linked associated instruments and chemicals in the Data Store to ensure full traceability of data related to the synthesis of ~400 nanomaterials. The system also supported researchers in implementing RDM practices in their workflows, e.g., by automating data import and documentation and by integrating infrastructure for data analysis. Based on the promising results of the pilot phase, we will roll out the Data Store as the central RDM infrastructure of BAM starting in 2023. We further aim to develop openBIS plugins, metadata standards, and RDM workflows to contribute to the openBIS community and to foster RDM in MSE.
- 7 September 2023
- Published by TIB Open Publishing in Proceedings of the Conference on Research Data Infrastructure
- Vol. 1
Open AccessBAM Data Store
As a partner in several NFDI consortia, the Bundesanstalt für Materialforschung und -prüfung (BAM, German federal institute for materials science and testing) contributes to research data standardization efforts in various domains of materials science and engineering (MSE). To implement a central research data management (RDM) infrastructure that meets the requirements of MSE groups at BAM, we initiated the Data Store pilot project in 2021. The resulting infrastructure should enable researchers to digitally document research processes and store related data in a standardized and interoperable manner. As a software solution, we chose openBIS, an open-source framework that is increasingly being used for RDM in MSE communities. The pilot project was conducted for one year with five research groups across different organizational units and MSE disciplines. The main results are presented for the use case “nanoPlattform”. The group registered experimental steps and linked associated instruments and chemicals in the Data Store to ensure full traceability of data related to the synthesis of ~400 nanomaterials. The system also supported researchers in implementing RDM practices in their workflows, e.g., by automating data import and documentation and by integrating infrastructure for data analysis. Based on the promising results of the pilot phase, we will roll out the Data Store as the central RDM infrastructure of BAM starting in 2023. We further aim to develop openBIS plugins, metadata standards, and RDM workflows to contribute to the openBIS community and to foster RDM in MSE.
- Open Access
- 19 October 2022
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 18 (48) , 9249-9262
Structure formation of PNIPAM microgels in foams and foam films
PNIPAM microgels form inhomogeneous network-like structures with microgel depleted and microgel bearing zones when confined in foam films.
- 19 October 2022
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 18 (48) , 9249-9262
Open AccessStructure formation of PNIPAM microgels in foams and foam films
PNIPAM microgels form inhomogeneous network-like structures with microgel depleted and microgel bearing zones when confined in foam films.
- 31 May 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (23) , 27347-27359
Insights into Extended Structures and Their Driving Force: Influence of Salt on Polyelectrolyte/Surfactant Mixtures at the Air/Water Interface
This paper addresses the effect of polyelectrolyte stiffness on the surface structure of polyelectrolyte (P)/surfactant (S) mixtures. Therefore, two different anionic Ps with different intrinsic persistence length lP are studied while varying the salt concentration (0-10-2 M). Either monosulfonated polyphenylene sulfone (sPSO2-220, lP ∼20 nm) or sodium poly(styrenesulfonate) (PSS, lP ∼1 nm) is mixed with the cationic surfactant tetradecyltrimethylammonium bromide (C14TAB) well below its critical micelle concentration and studied with tensiometry and neutron reflectivity experiments. We kept the S concentration (10-4 M) constant, while we varied the P concentration (10-5-10-3 M of the monomer, denoted as monoM). P and S adsorb at the air/water interface for all studied mixtures. Around the bulk stoichiometric mixing point (BSMP), PSS/C14TAB mixtures lose their surface activity, whereas sPSO2-220/C14TAB mixtures form extended structures perpendicular to the surface (meaning a layer of S with attached P and additional layers of P and S underneath instead of only a monolayer of S with P). Considering the different P monomer structures as well as the impact of salt, we identified the driving force for the formation of these extended structures: compensation of all interfacial charges (P/S ratio ∼1) to maximize the gain of entropy. By increasing the flexibility of P, we can tune the interfacial structures from extended structures to monolayers. These findings may help improve applications based on the adsorption of P/S mixtures in the fields of cosmetic or oil recovery.
- 31 May 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (23) , 27347-27359
Insights into Extended Structures and Their Driving Force: Influence of Salt on Polyelectrolyte/Surfactant Mixtures at the Air/Water Interface
This paper addresses the effect of polyelectrolyte stiffness on the surface structure of polyelectrolyte (P)/surfactant (S) mixtures. Therefore, two different anionic Ps with different intrinsic persistence length lP are studied while varying the salt concentration (0-10-2 M). Either monosulfonated polyphenylene sulfone (sPSO2-220, lP ∼20 nm) or sodium poly(styrenesulfonate) (PSS, lP ∼1 nm) is mixed with the cationic surfactant tetradecyltrimethylammonium bromide (C14TAB) well below its critical micelle concentration and studied with tensiometry and neutron reflectivity experiments. We kept the S concentration (10-4 M) constant, while we varied the P concentration (10-5-10-3 M of the monomer, denoted as monoM). P and S adsorb at the air/water interface for all studied mixtures. Around the bulk stoichiometric mixing point (BSMP), PSS/C14TAB mixtures lose their surface activity, whereas sPSO2-220/C14TAB mixtures form extended structures perpendicular to the surface (meaning a layer of S with attached P and additional layers of P and S underneath instead of only a monolayer of S with P). Considering the different P monomer structures as well as the impact of salt, we identified the driving force for the formation of these extended structures: compensation of all interfacial charges (P/S ratio ∼1) to maximize the gain of entropy. By increasing the flexibility of P, we can tune the interfacial structures from extended structures to monolayers. These findings may help improve applications based on the adsorption of P/S mixtures in the fields of cosmetic or oil recovery.
- Open Access
- 31 May 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (11) , 5116
Flexible Sample Environments for the Investigation of Soft Matter at the European Spallation Source: Part III—The Macroscopic Foam Cell
The European Spallation Source (ESS), which is under construction in Lund (Sweden), will be the leading and most brilliant neutron source and aims at starting user operation at the end of 2023. Among others, two small angle neutron scattering (SANS) machines will be operated. Due to the high brilliance of the source, it is important to minimize the downtime of the instruments. For this, a collaboration between three German universities and the ESS was initialized to develop and construct a unified sample environment (SE) system. The main focus was set on the use of a robust carrier system for the different SEs, which allows setting up experiments and first prealignment outside the SANS instruments. This article covers the development and construction of a SE for SANS experiments with foams, which allows measuring foams at different drainage states and the control of the rate of foam formation, temperature, and measurement position. The functionality under ESS conditions was tested and neutron test measurement were carried out.
- 31 May 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (11) , 5116
Open AccessFlexible Sample Environments for the Investigation of Soft Matter at the European Spallation Source: Part III—The Macroscopic Foam Cell
The European Spallation Source (ESS), which is under construction in Lund (Sweden), will be the leading and most brilliant neutron source and aims at starting user operation at the end of 2023. Among others, two small angle neutron scattering (SANS) machines will be operated. Due to the high brilliance of the source, it is important to minimize the downtime of the instruments. For this, a collaboration between three German universities and the ESS was initialized to develop and construct a unified sample environment (SE) system. The main focus was set on the use of a robust carrier system for the different SEs, which allows setting up experiments and first prealignment outside the SANS instruments. This article covers the development and construction of a SE for SANS experiments with foams, which allows measuring foams at different drainage states and the control of the rate of foam formation, temperature, and measurement position. The functionality under ESS conditions was tested and neutron test measurement were carried out.
- Open Access
- 29 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (9) , 4089
Flexible Sample Environments for the Investigation of Soft Matter at the European Spallation Source: Part I—The In Situ SANS/DLS Setup
As part of the development of the new European Spallation Source (ESS) in Lund (Sweden), which will provide the most brilliant neutron beams worldwide, it is necessary to provide different sample environments with which the potential of the new source can be exploited as soon as possible from the start of operation. The overarching goal of the project is to reduce the downtimes of the instruments related to changing the sample environment by developing plug and play sample environments for different soft matter samples using the same general carrier platform and also providing full software integration and control by just using unified connectors. In the present article, as a part of this endeavor, the sample environment for in situ SANS and dynamic light scattering measurements is introduced.
- 29 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (9) , 4089
Open AccessFlexible Sample Environments for the Investigation of Soft Matter at the European Spallation Source: Part I—The In Situ SANS/DLS Setup
As part of the development of the new European Spallation Source (ESS) in Lund (Sweden), which will provide the most brilliant neutron beams worldwide, it is necessary to provide different sample environments with which the potential of the new source can be exploited as soon as possible from the start of operation. The overarching goal of the project is to reduce the downtimes of the instruments related to changing the sample environment by developing plug and play sample environments for different soft matter samples using the same general carrier platform and also providing full software integration and control by just using unified connectors. In the present article, as a part of this endeavor, the sample environment for in situ SANS and dynamic light scattering measurements is introduced.
- Open Access
- 29 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (9) , 4036
Flexible Sample Environment for the Investigation of Soft Matter at the European Spallation Source: Part II—The GISANS Setup
The FlexiProb project is a joint effort of three soft matter groups at the Universities of Bielefeld, Darmstadt, and Munich with scientific support from the European Spallation Source (ESS), the small-K advanced diffractometer (SKADI) beamline development group of the Jülich Centre for Neutron Science (JCNS), and the Heinz Maier-Leibnitz Zentrum (MLZ). Within this framework, a flexible and quickly interchangeable sample carrier system for small-angle neutron scattering (SANS) at the ESS was developed. In the present contribution, the development of a sample environment for the investigation of soft matter thin films with grazing-incidence small-angle neutron scattering (GISANS) is introduced. Therefore, components were assembled on an optical breadboard for the measurement of thin film samples under controlled ambient conditions, with adjustable temperature and humidity, as well as the optional in situ recording of the film thickness via spectral reflectance. Samples were placed in a 3D-printed spherical humidity metal chamber, which enabled the accurate control of experimental conditions via water-heated channels within its walls. A separately heated gas flow stream supplied an adjustable flow of dry or saturated solvent vapor. First test experiments proved the concept of the setup and respective component functionality.
- 29 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (9) , 4036
Open AccessFlexible Sample Environment for the Investigation of Soft Matter at the European Spallation Source: Part II—The GISANS Setup
The FlexiProb project is a joint effort of three soft matter groups at the Universities of Bielefeld, Darmstadt, and Munich with scientific support from the European Spallation Source (ESS), the small-K advanced diffractometer (SKADI) beamline development group of the Jülich Centre for Neutron Science (JCNS), and the Heinz Maier-Leibnitz Zentrum (MLZ). Within this framework, a flexible and quickly interchangeable sample carrier system for small-angle neutron scattering (SANS) at the ESS was developed. In the present contribution, the development of a sample environment for the investigation of soft matter thin films with grazing-incidence small-angle neutron scattering (GISANS) is introduced. Therefore, components were assembled on an optical breadboard for the measurement of thin film samples under controlled ambient conditions, with adjustable temperature and humidity, as well as the optional in situ recording of the film thickness via spectral reflectance. Samples were placed in a 3D-printed spherical humidity metal chamber, which enabled the accurate control of experimental conditions via water-heated channels within its walls. A separately heated gas flow stream supplied an adjustable flow of dry or saturated solvent vapor. First test experiments proved the concept of the setup and respective component functionality.
- Open Access
- 11 December 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (3) , 035903
Time- and energy-resolved effects in the boron-10 based multi-grid and helium-3 based thermal neutron detectors
The boron-10 based multi-grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few µeV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of ∼ µs short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of µs wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.
- 11 December 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (3) , 035903
Open AccessTime- and energy-resolved effects in the boron-10 based multi-grid and helium-3 based thermal neutron detectors
The boron-10 based multi-grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few µeV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of ∼ µs short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of µs wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.
- Open Access
- 1 December 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (12) , 125111
Wavelength frame multiplication for reflectometry at long-pulse neutron sources
The European Spallation Source (ESS), which is under construction in Lund (Sweden), will be the next leading neutron facility with an unprecedented brilliance and novel long-pulse time structure. A long-pulse source not only provides a high time-average flux but also opens the possibility to tune the resolution by using pulse shaping choppers. Thus, an instrument can readily be operated in either a high flux or a high resolution mode. Several of the shorter instruments at the ESS will employ Wavelength Frame Multiplication (WFM) in order to enable a sufficient resolution while offering a continuous and broad wavelength range. A test beamline was operated until the end of 2019 at the research reactor in Berlin to test components and methods, including WFM, in order to prepare the new facility for the operation of neutron instruments and successful first science. We herein demonstrate the implementation of WFM for reflectometry. By selecting a short pulse mode under the same geometrical configuration, we compare and discuss the results for two reference samples. The reported experiments not only serve to prove the reliability of the WFM approach but also, for the first time, demonstrate the full instrument control, data acquisition and data reduction chain that will be implemented at the ESS.
- 1 December 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (12) , 125111
Open AccessWavelength frame multiplication for reflectometry at long-pulse neutron sources
The European Spallation Source (ESS), which is under construction in Lund (Sweden), will be the next leading neutron facility with an unprecedented brilliance and novel long-pulse time structure. A long-pulse source not only provides a high time-average flux but also opens the possibility to tune the resolution by using pulse shaping choppers. Thus, an instrument can readily be operated in either a high flux or a high resolution mode. Several of the shorter instruments at the ESS will employ Wavelength Frame Multiplication (WFM) in order to enable a sufficient resolution while offering a continuous and broad wavelength range. A test beamline was operated until the end of 2019 at the research reactor in Berlin to test components and methods, including WFM, in order to prepare the new facility for the operation of neutron instruments and successful first science. We herein demonstrate the implementation of WFM for reflectometry. By selecting a short pulse mode under the same geometrical configuration, we compare and discuss the results for two reference samples. The reported experiments not only serve to prove the reliability of the WFM approach but also, for the first time, demonstrate the full instrument control, data acquisition and data reduction chain that will be implemented at the ESS.
- Open Access
- 20 December 2019
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 56 (6) , 952-955
New structural approach to rationalize the foam film stability of oppositely charged polyelectrolyte/surfactant mixtures
The foam film stability of polyelectrolyte/surfactant mixtures is rationalized using structural data from neutron reflectometry for the first time.
- 20 December 2019
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 56 (6) , 952-955
Open AccessNew structural approach to rationalize the foam film stability of oppositely charged polyelectrolyte/surfactant mixtures
The foam film stability of polyelectrolyte/surfactant mixtures is rationalized using structural data from neutron reflectometry for the first time.