CBCharles P. Blakemore

Charles P. Blakemore

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Charles P. Blakemore has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dipole moment background measurement and suppression for levitated charge sensors

    by Nadav Priel, Alexander Fieguth, Charles P. Blakemore, Emmett Hough, Akio Kawasaki, Denzal Martin, Gautam Venugopalan, Giorgio Gratta

    Optically levitated macroscopic objects are a powerful tool in the field of force sensing, owing to high sensitivity, absolute force calibration, environmental isolation, and the advanced degree of control over their dynamics that have been achieved. However, limitations arise from the spurious forces caused by electrical polarization effects that, even for nominally neutral objects, affect the force sensing because of the interaction of dipole moments with gradients of external electric fields. Here, we introduce a technique to measure, model, and eliminate dipole moment interactions, limiting the performance of sensors using levitated objects. This process leads to a noise-limited measurement with a sensitivity of 3.3 × 10 −5 e . As a demonstration, this is applied to the search for unknown charges of a magnitude much below that of an electron or for exceedingly small unbalances between electron and proton charges.


  • Librational feedback cooling

    by Charles P. Blakemore, Denzal Martin, Alexander Fieguth, Nadav Priel, Gautam Venugopalan, Akio Kawasaki, Giorgio Gratta

    Librational motion, whereby a rigid body undergoes angular oscillation around a preferred direction, can be observed in optically trapped, silica microspheres. We demonstrate the cooling of 1 librational degree of freedom for ∼5−μm-diameter spheres that have been induced to rotate with an external electric field coupled to their electric dipole moment. Cooling is accomplished by adding a phase modulation to the rotating field. The degree of cooling is quantified by applying a π/2 shift to the phase of the electric field and fitting the resulting exponential decay of the librational motion to obtain a damping time, as well as estimating a mode temperature from the observed libration in equilibrium. The result is an important step in the study of the dynamics of trapped microspheres, crucial to cooling the mechanical motion to its ground state, as well as providing insights regarding the charge mobility in the material at microscopic scales.


  • A background-free optically levitated charge sensor

    by Nadav Priel, Alexander Fieguth, Emmett Hough, Charles Blakemore, Akio Kawasaki, Denzal Martin, Gautam Venugopalan, Giorgio Gratta

    Optically levitated macroscopic objects are a powerful tool in the field of force sensing, owing to high sensitivity, absolute force calibration, |


  • Novel Technique to Measure μm-Scale Forces Using a Non-Linear Attractor

    by Emmett Hough, Alexander Fieguth, Nadav Priel, Gautam Venugopalan, Charles Blakemore, Giorgio Gratta

    The gravitational force, while well-understood at large distances, has not been measured on scales below a few tens of microns. Several theoreti |

  • Librational feedback cooling with spinning silica microspheres

    by Charles Blakemore, Denzal Martin, Alexander Fieguth, Nadav Priel, Gautam Venugopalan, Akio Kawasaki, Giorgio Gratta

    An optically-levitated, 4.7 μm diameter silica microsphere can be driven into rotation by coupling a rotating electric field of constant magnitud |

  • Open Access

    Search for non-Newtonian interactions at micrometer scale with a levitated test mass

    by Charles P. Blakemore, Alexander Fieguth, Akio Kawasaki, Nadav Priel, Denzal Martin, Alexander D. Rider, Qidong Wang, Giorgio Gratta

    We report on a search for non-Newtonian forces that couple to mass, with a characteristic scale of ∼10  μm, using an optically levitated microsphere as a precision force sensor. A silica microsphere trapped in an upward-propagating, single-beam, optical tweezer is utilized to probe for interactions sourced from a nanofabricated attractor mass with a density modulation brought into close proximity to the microsphere and driven along the axis of periodic density in order to excite an oscillating response. We obtain a force sensitivity of ≲10−16  N/Hz. Separately searching for attractive and repulsive forces results in the constraint on a new Yukawa interaction of |α|≳108 for λ>10  μm. This is the first test of the inverse-square law using an optically levitated test mass of dimensions comparable to λ, a complementary method subject to a different set of systematic effects compared to more established techniques.


  • High sensitivity, levitated microsphere apparatus for short-distance force measurements

    by Akio Kawasaki, Alexander Fieguth, Nadav Priel, Charles P. Blakemore, Denzal Martin, Giorgio Gratta

    A high sensitivity force sensor based on dielectric microspheres in vacuum, optically trapped by a single, upward-propagating laser beam, is described. Off-axis parabolic mirrors are used both to focus the 1064 nm trapping beam and to recollimate it to provide information on the horizontal position of the microsphere. The vertical degree of freedom is readout by forming an interferometer between the light retroreflected by the microsphere and a reference beam, hence eliminating the need for auxiliary beams. The focus of the trapping beam has a 1/E2 radius of 3.2 µm and small non-Gaussian tails, suitable for bringing devices close to the trapped microsphere without disturbing the optical field. Electrodes surrounding the trapping region provide excellent control of the electric field, which can be used to drive the translational degrees of freedom of a charged microsphere and the rotational degrees of freedom of a neutral microsphere, coupling to its electric dipole moment. With this control, the charge state can be determined with single electron precision, the mass of individual microspheres can be measured, and empirical calibrations of the force sensitivity can be made for each microsphere. A force noise of <1 × 10−17 N/Hz , which is comparable to previous reports, is measured on all three degrees of freedom for 4.7 µm diameter, 84 pg silica microspheres. Various devices have been brought within 1.6 µm of the surface of a trapped microsphere. Metrology in the trapping region is provided by two custom-designed microscopes providing views in the horizontal and one of the vertical planes. The apparatus opens the way to performing high sensitivity three-dimensional force measurements at a short distance.


  • Absolute pressure and gas species identification with an optically levitated rotor

    by Charles P. Blakemore, Denzal Martin, Alexander Fieguth, Akio Kawasaki, Nadav Priel, Alexander D. Rider, Giorgio Gratta

    The authors describe a novel variety of spinning-rotor vacuum gauge in which the rotor is a ∼4.7−μm−diameter silica microsphere, optically levitated. A rotating electrostatic field is used to apply torque to the permanent electric dipole moment of the silica microsphere and control its rotational degrees of freedom. When released from a driving field, the microsphere’s angular velocity decays exponentially with a damping time inversely proportional to the residual gas pressure and dependent on gas composition. The gauge is calibrated by measuring the rotor mass with electrostatic co-levitation and assuming a spherical shape, confirmed separately, and uniform density. The gauge is cross-checked against a capacitance manometer by observing the torsional drag due to a number of different gas species. The techniques presented can be used to perform absolute vacuum measurements localized in space, owing to the small dimensions of the microsphere and the ability to translate the optical trap in three dimensions, as well as measurements in magnetic field environments. In addition, the dynamics of the microsphere, paired with a calibrated vacuum gauge, can be used to measure the effective molecular mass of a gas mixture without the need for ionization and at pressures up to approximately 1 mbar.


  • Precision Mass and Density Measurement of Individual Optically Levitated Microspheres

    by Charles P. Blakemore, Alexander D. Rider, Sandip Roy, Alexander Fieguth, Akio Kawasaki, Nadav Priel, Giorgio Gratta

    We report an in situ mass measurement of approximately-4.7-μm-diameter, optically levitated microspheres with an electrostatic co-levitation technique. The mass of a trapped, charged microsphere is measured by holding its axial (vertical) position fixed with an optical feedback force, under the influence of a known electrostatic force. A mass measurement with 1.8% systematic uncertainty is obtained by extrapolating the electrostatic force required to support the microsphere against gravity in the absence of optical power. In three cases the microspheres are recovered from the trap on a polymer-coated silicon beam and imaged with an electron microscope to measure their radii. The simultaneous precision characterization of the mass and radius of individual microspheres implies a density of 1.55±0.08g/cm3. The ability to recover individual microspheres from an optical trap opens the door to further diagnostics.


  • Open Access

    Electrically driven, optically levitated microscopic rotors

    by Alexander D. Rider, Charles P. Blakemore, Akio Kawasaki, Nadav Priel, Sandip Roy, Giorgio Gratta

    We report on the electrically driven rotation of 2.4−μm-radius, optically levitated dielectric microspheres. Electric fields are used to apply torques to a microsphere's permanent electric dipole moment, while angular displacement is measured by detecting the change in polarization state of light transmitted through the microsphere (MS). This technique enables greater control than previously achieved with purely optical means because the direction and magnitude of the electric torque can be set arbitrarily. We measure the spin-down of a microsphere released from a rotating electric field, the harmonic motion of the dipole relative to the instantaneous direction of the field, and the phase lag between the driving electric field and the dipole moment of the MS due to drag from residual gas. We also observe the gyroscopic precession of the MS when the axis of rotation of the driving field and the angular momentum of the microsphere are orthogonal. These observations are in quantitative agreement with the equation of motion. The control offered by the electrical drive enables precise measurements of microsphere properties and torque as well as a method for addressing the direction of angular momentum for an optically levitated particle.