Pika Meško Brguljan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pika Meško Brguljan has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Guilaine Boursier
Department of Molecular Genetics and Cytogenomics, Montpellier University Hospital, Reference Center for Auto-Inflammatory Diseases and Inflammatory Amyloidosis, French National Institute of Health and Medical Research
9 shared publications - Marc Thelen
Department of Laboratory Medicine , Radboud University Medical Center , Nijmegen , The Netherlands
9 shared publications - Florent Vanstapel
Laboratory Medicine , University Hospital Leuven , Leuven , Belgium
7 shared publications - Francisco Antonio Bernabeu Andreu
Servicio de Análisis Clinicos - H.U. Puerta de Hierro Majadahonda, Majadahonda, Madrid, Spain
7 shared publications - Solveig Linko
Linko Q-Solutions , Helsinki , Finland
6 shared publications - Duilio Brugnoni
Clinical Chemistry Laboratory, Spedali Civili, Brescia, Italy
5 shared publications
Latest Publications
- 29 July 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 65 (1) , 41-50
The severity of harm score database: an evidence-based foundation for laboratory test risk analysis
Background: Patient risk management has become central to clinical laboratory quality standards, including the Clinical and Laboratory Standards Institute (CLSI) EP23 2nd edition (CLSI EP23-ED2), International Organization for Standardization (ISO) 15189:2022, ISO 22367:2026, and ISO 14971:2019. A key component of risk analysis is estimating the severity of harm (SoH) that may result from erroneous laboratory results. We present here the Severity of Harm Evidence Database, a structured, multi-study resource that integrates survey-based SoH assessments from the published independent studies. The database provides ordinal distributions and pooled SoH for 196 unique laboratory tests. Methods: A canonical five-level scale (negligible, minor, serious, critical, catastrophic) was adopted, aligned with ISO 14971:2019. For the 19 tests common to both studies, direct count pooling was performed by summing category-level respondent counts. Wilson score confidence intervals were calculated for all proportions. The database is organized into nine relational sheets and is accompanied by an interactive web application. Results: Out of the 196 tests covered, 19 have pooled estimates from both studies (total n=781 respondents). Pooled analysis confirms that cardiac biomarkers, blood gases, coagulation parameters, electrolytes (potassium, sodium), and therapeutic drug concentrations (digoxin, lithium) consistently receive the highest severity ratings, while certain endocrine markers receive lower scores. Conclusions: The SoH evidence database offers the first publicly available, structured repository of SoH assessments for clinical laboratory tests. It supports compliance with risk management requirements, informs risk-based strategies per CLSI EP23-ED2, and provides an evidence-based foundation for laboratory risk analysis.
- 29 July 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 65 (1) , 41-50
The severity of harm score database: an evidence-based foundation for laboratory test risk analysis
Background: Patient risk management has become central to clinical laboratory quality standards, including the Clinical and Laboratory Standards Institute (CLSI) EP23 2nd edition (CLSI EP23-ED2), International Organization for Standardization (ISO) 15189:2022, ISO 22367:2026, and ISO 14971:2019. A key component of risk analysis is estimating the severity of harm (SoH) that may result from erroneous laboratory results. We present here the Severity of Harm Evidence Database, a structured, multi-study resource that integrates survey-based SoH assessments from the published independent studies. The database provides ordinal distributions and pooled SoH for 196 unique laboratory tests. Methods: A canonical five-level scale (negligible, minor, serious, critical, catastrophic) was adopted, aligned with ISO 14971:2019. For the 19 tests common to both studies, direct count pooling was performed by summing category-level respondent counts. Wilson score confidence intervals were calculated for all proportions. The database is organized into nine relational sheets and is accompanied by an interactive web application. Results: Out of the 196 tests covered, 19 have pooled estimates from both studies (total n=781 respondents). Pooled analysis confirms that cardiac biomarkers, blood gases, coagulation parameters, electrolytes (potassium, sodium), and therapeutic drug concentrations (digoxin, lithium) consistently receive the highest severity ratings, while certain endocrine markers receive lower scores. Conclusions: The SoH evidence database offers the first publicly available, structured repository of SoH assessments for clinical laboratory tests. It supports compliance with risk management requirements, informs risk-based strategies per CLSI EP23-ED2, and provides an evidence-based foundation for laboratory risk analysis.
- 22 June 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (10) , 2173-2187
Guidance in the application of quality management in the field of chromatography in routine medical laboratories – EFLM Committee: Accreditation and ISO/CEN Standards point of view
Background: Chromatographic separation has become a critical analytical technique in routine laboratory medicine. Although several documents address standardisation in chromatography, they largely focus on industrial and pharmaceutical applications. Routine medical laboratories remain underserved, creating a need for guidance tailored to their specific context. This paper aims to provide technical guidance on applying ISO 15189:2022 requirements to chromatographic methods, ensuring quality and risk management across all laboratory phases. Content: Building on previous work of the European Federation of Laboratory Medicine Committee on Accreditation and ISO/CEN Standards, we reviewed ISO 15189:2022 requirements and interpreted them in relation to chromatographic procedures. Key vulnerabilities inherent to chromatography – such as sample preparation variability, column performance drift, and detector calibration – were identified and mapped to relevant quality and competence clauses. Summary and Outlook: The guidance highlights chromatography-specific risks and proposes structured verification, documentation, and risk management strategies. It addresses pre-analytical, analytical, and post-analytical phases, emphasizing traceability, method verification, and result of release. Special consideration is given to laboratory-developed tests using chromatographic techniques, aligning them with European in vitro diagnostic regulation. By contextualising ISO 15189:2022 within the technical realities of chromatography, this paper provides laboratories and auditors with practical tools to safeguard quality, reduce uncertainty, and ensure reliable patient results. The proposed framework advances regulatory harmonisation and supports the routine implementation of chromatography in medical laboratories.
- 22 June 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (10) , 2173-2187
Guidance in the application of quality management in the field of chromatography in routine medical laboratories – EFLM Committee: Accreditation and ISO/CEN Standards point of view
Background: Chromatographic separation has become a critical analytical technique in routine laboratory medicine. Although several documents address standardisation in chromatography, they largely focus on industrial and pharmaceutical applications. Routine medical laboratories remain underserved, creating a need for guidance tailored to their specific context. This paper aims to provide technical guidance on applying ISO 15189:2022 requirements to chromatographic methods, ensuring quality and risk management across all laboratory phases. Content: Building on previous work of the European Federation of Laboratory Medicine Committee on Accreditation and ISO/CEN Standards, we reviewed ISO 15189:2022 requirements and interpreted them in relation to chromatographic procedures. Key vulnerabilities inherent to chromatography – such as sample preparation variability, column performance drift, and detector calibration – were identified and mapped to relevant quality and competence clauses. Summary and Outlook: The guidance highlights chromatography-specific risks and proposes structured verification, documentation, and risk management strategies. It addresses pre-analytical, analytical, and post-analytical phases, emphasizing traceability, method verification, and result of release. Special consideration is given to laboratory-developed tests using chromatographic techniques, aligning them with European in vitro diagnostic regulation. By contextualising ISO 15189:2022 within the technical realities of chromatography, this paper provides laboratories and auditors with practical tools to safeguard quality, reduce uncertainty, and ensure reliable patient results. The proposed framework advances regulatory harmonisation and supports the routine implementation of chromatography in medical laboratories.
- Top Cited Papers
- 28 May 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 63 (10) , 1891-1914
Regulating the future of laboratory medicine: European regulatory landscape of AI-driven medical device software in laboratory medicine
Artificial intelligence (AI) is rapidly transforming laboratory medicine, impacting medical devices and healthcare practices. Despite these advancements, AI-based medical device software (MDSW) introduces a new layer of complexity in regulatory compliance. This paper outlines the regulatory landscape for MDSW and AI-driven MDSW, clarifying the responsibilities of laboratory professionals and manufacturers under the In Vitro Diagnostic Regulation (IVDR), ISO 15189:2022, and the Artificial Intelligence Act. An analysis of 89 MDSWs approved under the IVDR, derived from the European Database on Medical Devices (EUDAMED) reveals a diverse landscape of applications, ranging from digital pathology and molecular diagnostics to laboratory automation and clinical decision support. While Germany currently dominates the EU market for these devices, and the majority of approved MDSW remain non-AI driven and classified as low-risk, the increasing presence of AI-powered Class C devices underscores the growing potential of software in complex diagnostic scenarios. However, realizing the full potential of AI in laboratory medicine requires careful navigation of the evolving regulatory landscape. Key challenges persist, including defining intended use, ensuring robust clinical evidence, mitigating data bias, and establishing rigorous post-market surveillance. Balancing regulatory oversight with innovation is critical to fostering the development of trustworthy AI systems without stifling progress. As regulatory frameworks continue to evolve, establishing clear validation methodologies and transparent compliance pathways will be essential to unlocking the full potential of AI in laboratory medicine while ensuring the highest standards of safety and clinical effectiveness.
- 28 May 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 63 (10) , 1891-1914
Top Cited PapersRegulating the future of laboratory medicine: European regulatory landscape of AI-driven medical device software in laboratory medicine
Artificial intelligence (AI) is rapidly transforming laboratory medicine, impacting medical devices and healthcare practices. Despite these advancements, AI-based medical device software (MDSW) introduces a new layer of complexity in regulatory compliance. This paper outlines the regulatory landscape for MDSW and AI-driven MDSW, clarifying the responsibilities of laboratory professionals and manufacturers under the In Vitro Diagnostic Regulation (IVDR), ISO 15189:2022, and the Artificial Intelligence Act. An analysis of 89 MDSWs approved under the IVDR, derived from the European Database on Medical Devices (EUDAMED) reveals a diverse landscape of applications, ranging from digital pathology and molecular diagnostics to laboratory automation and clinical decision support. While Germany currently dominates the EU market for these devices, and the majority of approved MDSW remain non-AI driven and classified as low-risk, the increasing presence of AI-powered Class C devices underscores the growing potential of software in complex diagnostic scenarios. However, realizing the full potential of AI in laboratory medicine requires careful navigation of the evolving regulatory landscape. Key challenges persist, including defining intended use, ensuring robust clinical evidence, mitigating data bias, and establishing rigorous post-market surveillance. Balancing regulatory oversight with innovation is critical to fostering the development of trustworthy AI systems without stifling progress. As regulatory frameworks continue to evolve, establishing clear validation methodologies and transparent compliance pathways will be essential to unlocking the full potential of AI in laboratory medicine while ensuring the highest standards of safety and clinical effectiveness.
- Open Access
- 19 February 2024
- Published by Walter de Gruyter GmbH in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
- Vol. 5 (2) , 109-114
Grupo de Trabajo de la EFLM sobre Acreditación y Normas ISO/CEN sobre cómo abordar los requisitos de la norma ISO15189 sobre retención de documentación y muestras
Resumen: Gran parte de la actividad en el laboratorio clínico debe quedar documentada para facilitar el mantenimiento de la calidad del servicio, lo que deriva en la generación de una gran cantidad de documentación, formularios e informes. Con tal objeto, es necesario especificar el tiempo de retención requerido para cada tipo de documento y muestra. Además de la obligación de conservar los informes del laboratorio clínico como parte de la historia clínica de los pacientes, el laboratorio también está obligado por ley, o según las directrices de las organizaciones profesionales, si las hubiera, a retener un gran volumen de documentación y muestras. En caso contrario, la dirección del laboratorio deberá establecer un calendario de retención, en el que se especifiquen las condiciones y el periodo de conservación, de acuerdo con los requisitos de la norma ISO 15189:2022 sobre retención de documentación y registros de gestión de la calidad. En el presente proyecto, el Grupo de Trabajo de la EFLM sobre Acreditación y Normas ISO/CEN propone una serie de periodos de retención de documentación y muestras, basada en la metodología de análisis modal de fallos y efectos (AMFE), un método para la reducción de riesgos que ha pasado a formar parte integral de los estándares actuales.
- 19 February 2024
- Published by Walter de Gruyter GmbH in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
- Vol. 5 (2) , 109-114
Open AccessGrupo de Trabajo de la EFLM sobre Acreditación y Normas ISO/CEN sobre cómo abordar los requisitos de la norma ISO15189 sobre retención de documentación y muestras
Resumen: Gran parte de la actividad en el laboratorio clínico debe quedar documentada para facilitar el mantenimiento de la calidad del servicio, lo que deriva en la generación de una gran cantidad de documentación, formularios e informes. Con tal objeto, es necesario especificar el tiempo de retención requerido para cada tipo de documento y muestra. Además de la obligación de conservar los informes del laboratorio clínico como parte de la historia clínica de los pacientes, el laboratorio también está obligado por ley, o según las directrices de las organizaciones profesionales, si las hubiera, a retener un gran volumen de documentación y muestras. En caso contrario, la dirección del laboratorio deberá establecer un calendario de retención, en el que se especifiquen las condiciones y el periodo de conservación, de acuerdo con los requisitos de la norma ISO 15189:2022 sobre retención de documentación y registros de gestión de la calidad. En el presente proyecto, el Grupo de Trabajo de la EFLM sobre Acreditación y Normas ISO/CEN propone una serie de periodos de retención de documentación y muestras, basada en la metodología de análisis modal de fallos y efectos (AMFE), un método para la reducción de riesgos que ha pasado a formar parte integral de los estándares actuales.
- Open Access
- 30 January 2024
- Published by Walter de Gruyter GmbH in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
- Vol. 5 (2) , 103-108
EFLM Working Group Accreditation and ISO/CEN standards on dealing with ISO 15189 demands for retention of documents and examination objects
Many aspects of the activity of a medical laboratory have to be documented so as to facilitate the maintenance of the ongoing quality of service. As a consequence, many documents, forms and reports are generated. The retention time for each of these has to be specified. In addition to medical laboratory reports as part of the patient’s medical record, the medical laboratory has to retain many documents and specimens according to national legislation or guidance from professional organizations, if these exist. If not, the laboratory management needs to define a retention schedule, which shall define the storage conditions and period of storage, according to ISO 15189:2022 requirements for retention of general quality management documents and records. The EFLM Working Group on Accreditation and ISO/CEN standards provides here a proposal on retention periods of documentation and specimens based on a failure-mode-effects-analysis (FMEA) risk-based approach, a concept of risk reduction that has become an integral part of modern standards.
- 30 January 2024
- Published by Walter de Gruyter GmbH in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
- Vol. 5 (2) , 103-108
Open AccessEFLM Working Group Accreditation and ISO/CEN standards on dealing with ISO 15189 demands for retention of documents and examination objects
Many aspects of the activity of a medical laboratory have to be documented so as to facilitate the maintenance of the ongoing quality of service. As a consequence, many documents, forms and reports are generated. The retention time for each of these has to be specified. In addition to medical laboratory reports as part of the patient’s medical record, the medical laboratory has to retain many documents and specimens according to national legislation or guidance from professional organizations, if these exist. If not, the laboratory management needs to define a retention schedule, which shall define the storage conditions and period of storage, according to ISO 15189:2022 requirements for retention of general quality management documents and records. The EFLM Working Group on Accreditation and ISO/CEN standards provides here a proposal on retention periods of documentation and specimens based on a failure-mode-effects-analysis (FMEA) risk-based approach, a concept of risk reduction that has become an integral part of modern standards.
- 19 October 2023
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (4) , 597-607
APS calculator: a data-driven tool for setting outcome-based analytical performance specifications for measurement uncertainty using specific clinical requirements and population data
Objectives: According to ISO 15189:2022, analytical performance specifications (APS) should relate to intended clinical use and impact on patient care. Therefore, we aimed to develop a web application for laboratory professionals to calculate APS based on a simulation of the impact of measurement uncertainty (MU) on the outcome using the chosen decision limits, agreement thresholds, and data of the population of interest. Methods: We developed the “APS Calculator” allowing users to upload and select data of concern, specify decision limits and agreement thresholds, and conduct simulations to determine APS for MU. The simulation involved categorizing original measurand concentrations, generating measured (simulated) results by introducing different degrees of MU, and recategorizing measured concentrations based on clinical decision limits and acceptable clinical misclassification rates. The agreements between original and simulated result categories were assessed, and values that met or exceeded user-specified agreement thresholds that set goals for the between-category agreement were considered acceptable. The application generates contour plots of agreement rates and corresponding MU values. We tested the application using National Health and Nutrition Examination Survey data, with decision limits from relevant guidelines. Results: We determined APS for MU of six measurands (blood total hemoglobin, plasma fasting glucose, serum total and high-density lipoprotein cholesterol, triglycerides, and total folate) to demonstrate the potential of the application to generate APS. Conclusions: The developed data-driven web application offers a flexible tool for laboratory professionals to calculate APS for MU using their chosen decision limits and agreement thresholds, and the data of the population of interest.
- 19 October 2023
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (4) , 597-607
APS calculator: a data-driven tool for setting outcome-based analytical performance specifications for measurement uncertainty using specific clinical requirements and population data
Objectives: According to ISO 15189:2022, analytical performance specifications (APS) should relate to intended clinical use and impact on patient care. Therefore, we aimed to develop a web application for laboratory professionals to calculate APS based on a simulation of the impact of measurement uncertainty (MU) on the outcome using the chosen decision limits, agreement thresholds, and data of the population of interest. Methods: We developed the “APS Calculator” allowing users to upload and select data of concern, specify decision limits and agreement thresholds, and conduct simulations to determine APS for MU. The simulation involved categorizing original measurand concentrations, generating measured (simulated) results by introducing different degrees of MU, and recategorizing measured concentrations based on clinical decision limits and acceptable clinical misclassification rates. The agreements between original and simulated result categories were assessed, and values that met or exceeded user-specified agreement thresholds that set goals for the between-category agreement were considered acceptable. The application generates contour plots of agreement rates and corresponding MU values. We tested the application using National Health and Nutrition Examination Survey data, with decision limits from relevant guidelines. Results: We determined APS for MU of six measurands (blood total hemoglobin, plasma fasting glucose, serum total and high-density lipoprotein cholesterol, triglycerides, and total folate) to demonstrate the potential of the application to generate APS. Conclusions: The developed data-driven web application offers a flexible tool for laboratory professionals to calculate APS for MU using their chosen decision limits and agreement thresholds, and the data of the population of interest.
- 29 August 2022
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 61 (4) , 608-626
ISO 15189 is a sufficient instrument to guarantee high-quality manufacture of laboratory developed tests for in-house-use conform requirements of the European In-Vitro-Diagnostics Regulation
The EU In-Vitro Diagnostic Device Regulation (IVDR) aims for transparent risk-and purpose-based validation of diagnostic devices, traceability of results to uniquely identified devices, and post-market surveillance. The IVDR regulates design, manufacture and putting into use of devices, but not medical services using these devices. In the absence of suitable commercial devices, the laboratory can resort to laboratory-developed tests (LDT) for in-house use. Documentary obligations (IVDR Art 5.5), the performance and safety specifications of ANNEX I, and development and manufacture under an ISO 15189-equivalent quality system apply. LDTs serve specific clinical needs, often for low volume niche applications, or correspond to the translational phase of new tests and treatments, often extremely relevant for patient care. As some commercial tests may disappear with the IVDR roll-out, many will require urgent LDT replacement. The workload will also depend on which modifications to commercial tests turns them into an LDT, and on how national legislators and competent authorities (CA) will handle new competences and responsibilities. We discuss appropriate interpretation of ISO 15189 to cover IVDR requirements. Selected cases illustrate LDT implementation covering medical needs with commensurate management of risk emanating from intended use and/or design of devices. Unintended collateral damage of the IVDR comprises loss of non-profitable niche applications, increases of costs and wasted resources, and migration of innovative research to more cost-efficient environments. Taking into account local specifics, the legislative framework should reduce the burden on and associated opportunity costs for the health care system, by making diligent use of existing frameworks.
- 29 August 2022
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 61 (4) , 608-626
ISO 15189 is a sufficient instrument to guarantee high-quality manufacture of laboratory developed tests for in-house-use conform requirements of the European In-Vitro-Diagnostics Regulation
The EU In-Vitro Diagnostic Device Regulation (IVDR) aims for transparent risk-and purpose-based validation of diagnostic devices, traceability of results to uniquely identified devices, and post-market surveillance. The IVDR regulates design, manufacture and putting into use of devices, but not medical services using these devices. In the absence of suitable commercial devices, the laboratory can resort to laboratory-developed tests (LDT) for in-house use. Documentary obligations (IVDR Art 5.5), the performance and safety specifications of ANNEX I, and development and manufacture under an ISO 15189-equivalent quality system apply. LDTs serve specific clinical needs, often for low volume niche applications, or correspond to the translational phase of new tests and treatments, often extremely relevant for patient care. As some commercial tests may disappear with the IVDR roll-out, many will require urgent LDT replacement. The workload will also depend on which modifications to commercial tests turns them into an LDT, and on how national legislators and competent authorities (CA) will handle new competences and responsibilities. We discuss appropriate interpretation of ISO 15189 to cover IVDR requirements. Selected cases illustrate LDT implementation covering medical needs with commensurate management of risk emanating from intended use and/or design of devices. Unintended collateral damage of the IVDR comprises loss of non-profitable niche applications, increases of costs and wasted resources, and migration of innovative research to more cost-efficient environments. Taking into account local specifics, the legislative framework should reduce the burden on and associated opportunity costs for the health care system, by making diligent use of existing frameworks.
- Open Access
- 12 November 2019
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 58 (3) , 361-367
Validation and verification of examination procedures in medical laboratories: opinion of the EFLM Working Group Accreditation and ISO/CEN standards (WG-A/ISO) on dealing with ISO 15189:2012 demands for method verification and validation
This paper reflects the opinion of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group Accreditation and ISO/CEN standards (WG-A/ISO). It aims to provide guidance for drawing up local/national documents about validation and verification of laboratory methods. We demonstrate how risk evaluation can be used to optimize laboratory policies to meet intended use requirements as well as requirements of standards. This is translated in a number of recommendations on how to introduce risk evaluation in various stages of the implementation of new methods ultimately covering the whole process cycle.
- 12 November 2019
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 58 (3) , 361-367
Open AccessValidation and verification of examination procedures in medical laboratories: opinion of the EFLM Working Group Accreditation and ISO/CEN standards (WG-A/ISO) on dealing with ISO 15189:2012 demands for method verification and validation
This paper reflects the opinion of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group Accreditation and ISO/CEN standards (WG-A/ISO). It aims to provide guidance for drawing up local/national documents about validation and verification of laboratory methods. We demonstrate how risk evaluation can be used to optimize laboratory policies to meet intended use requirements as well as requirements of standards. This is translated in a number of recommendations on how to introduce risk evaluation in various stages of the implementation of new methods ultimately covering the whole process cycle.
- 4 December 2018
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 57 (4) , 459-464
Documenting metrological traceability as intended by ISO 15189:2012: A consensus statement about the practice of the implementation and auditing of this norm element
ISO15189:2012 requires medical laboratories to document metrological traceability of their results. While the ISO17511:2003 standard on metrological traceability in laboratory medicine requires the use of the highest available level in the traceability chain, it recognizes that for many measurands there is no reference above the manufacturer’s selected measurement procedure and the manufacturer’s working calibrator. Some immunoassays, although they intend to measure the same quantity and may even refer to the same reference material, unfortunately produce different results because of differences in analytical selectivity as manufacturers select different epitopes and antibodies for the same analyte. In other cases, the cause is the use of reference materials, which are not commutable. The uncertainty associated with the result is another important aspect in metrological traceability implementation. As the measurement uncertainty on the clinical samples is influenced by the uncertainty of all steps higher in the traceability chain, laboratories should be provided with adequate and appropriate information on the uncertainty of the value assignment to the commercial calibrators that they use. Although the between-lot variation in value assignment will manifest itself as part of the long-term imprecision as estimated by the end-user, information on worst-case to be expected lot-lot variation has to be communicated to the end-user by the IVD provider. When laboratories use ancillary equipment that potentially could have a critical contribution to the reported results, such equipment needs verification of its proper calibration and criticality to the result uncertainty could be assessed by an approach based on risk analysis, which is a key element of ISO15189:2012 anyway. This paper discusses how the requirement for metrological traceability as stated in ISO15189 should be met by the medical laboratory and how this should be assessed by accreditation bodies.
- 4 December 2018
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 57 (4) , 459-464
Documenting metrological traceability as intended by ISO 15189:2012: A consensus statement about the practice of the implementation and auditing of this norm element
ISO15189:2012 requires medical laboratories to document metrological traceability of their results. While the ISO17511:2003 standard on metrological traceability in laboratory medicine requires the use of the highest available level in the traceability chain, it recognizes that for many measurands there is no reference above the manufacturer’s selected measurement procedure and the manufacturer’s working calibrator. Some immunoassays, although they intend to measure the same quantity and may even refer to the same reference material, unfortunately produce different results because of differences in analytical selectivity as manufacturers select different epitopes and antibodies for the same analyte. In other cases, the cause is the use of reference materials, which are not commutable. The uncertainty associated with the result is another important aspect in metrological traceability implementation. As the measurement uncertainty on the clinical samples is influenced by the uncertainty of all steps higher in the traceability chain, laboratories should be provided with adequate and appropriate information on the uncertainty of the value assignment to the commercial calibrators that they use. Although the between-lot variation in value assignment will manifest itself as part of the long-term imprecision as estimated by the end-user, information on worst-case to be expected lot-lot variation has to be communicated to the end-user by the IVD provider. When laboratories use ancillary equipment that potentially could have a critical contribution to the reported results, such equipment needs verification of its proper calibration and criticality to the result uncertainty could be assessed by an approach based on risk analysis, which is a key element of ISO15189:2012 anyway. This paper discusses how the requirement for metrological traceability as stated in ISO15189 should be met by the medical laboratory and how this should be assessed by accreditation bodies.
- Open Access
- 1 January 2011
- Published by Croatian Society for Medical Biochemistry and Laboratory Medicine in Biochemia Medica
- Vol. 21 (1) , 7-11
The regulation of clinical chemistry in Slovenia
The regulation of clinical chemistry in Slovenia
- 1 January 2011
- Published by Croatian Society for Medical Biochemistry and Laboratory Medicine in Biochemia Medica
- Vol. 21 (1) , 7-11
Open AccessThe regulation of clinical chemistry in Slovenia
The regulation of clinical chemistry in Slovenia