NMNanjundappa Madhukeshwara
Nanjundappa Madhukeshwara
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nanjundappa Madhukeshwara has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Hassan A. H. Alzahrani
Department of Chemistry, College of Science and Arts at Khulis, University of Jeddah, Jeddah, Saudi Arabia
3 shared publications Abdulmohsen O. Alsaiari
2 shared publications- B. M. Prasanna
Department of Chemistry, Bapuji Institute of Engineering & Technology (Affiliated to Visvesvaraya Technological University, Belagavi), Davanagere, India
2 shared publications B.M. Prasanna
2 shared publicationsEydhah Almatrafi
2 shared publicationsA Alhadhrami
Department of Chemistry, College of Science, Taif University, P. O. Box 11099, Taif 21944, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 27 October 2023
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 51
Enhancing solar air heater efficiency with 3D cylinder shaped roughness elements
- 27 October 2023
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 51
Open AccessEnhancing solar air heater efficiency with 3D cylinder shaped roughness elements
- Open Access
- 7 June 2023
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 48
Heat transfer and air flow friction in solar air heaters: A comprehensive computational and experimental investigation with wire-roughened absorber plate
- 7 June 2023
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 48
Open AccessHeat transfer and air flow friction in solar air heaters: A comprehensive computational and experimental investigation with wire-roughened absorber plate
- Open Access
- 29 October 2022
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 40
Heat transmission and air flow friction in a solar air heater with a ribbed absorber plate: A computational study
- 29 October 2022
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 40
Open AccessHeat transmission and air flow friction in a solar air heater with a ribbed absorber plate: A computational study
- 9 December 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
Thermal–hydraulic analysis of a solar air heater fitted with a wire-roughened absorber plate
This study is to evaluate heat transmission and friction in a rectangular solar air heater with a V-shaped wire rib roughness on the absorber plate that operates in fully formed turbulent flow. Additionally, studies are performed to generate prediction equations for the average friction factor, Stanton number, and efficiency index. The Reynolds number – , angle of attack 20 –90 ), relative roughness pitch – , relative roughness height – , and the aspect ratio – was varied. The efficiency index is commonly employed as a thermo-hydraulic performance metric. It is computed as . The wire roughness and airflow parameters are optimized to maximize heat transfer while retaining minimal friction losses. On the basis of resemblance criteria, average Stanton numbers, average Nusselt numbers, and even average friction factors are derived. The results are compared to those obtained with a smooth absorber duct under similar airflow circumstances in order to assess the increase in heat transfer coefficient and friction factor. The , and have a significant influence on thermo–hydraulic performance, according to these studies. With , , , and , the optimal configuration geometry for wire roughness and solar air heater duct is identified.- 9 December 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
Thermal–hydraulic analysis of a solar air heater fitted with a wire-roughened absorber plate
This study is to evaluate heat transmission and friction in a rectangular solar air heater with a V-shaped wire rib roughness on the absorber plate that operates in fully formed turbulent flow. Additionally, studies are performed to generate prediction equations for the average friction factor, Stanton number, and efficiency index. The Reynolds number – , angle of attack 20 –90 ), relative roughness pitch – , relative roughness height – , and the aspect ratio – was varied. The efficiency index is commonly employed as a thermo-hydraulic performance metric. It is computed as . The wire roughness and airflow parameters are optimized to maximize heat transfer while retaining minimal friction losses. On the basis of resemblance criteria, average Stanton numbers, average Nusselt numbers, and even average friction factors are derived. The results are compared to those obtained with a smooth absorber duct under similar airflow circumstances in order to assess the increase in heat transfer coefficient and friction factor. The , and have a significant influence on thermo–hydraulic performance, according to these studies. With , , , and , the optimal configuration geometry for wire roughness and solar air heater duct is identified.- Open Access
- 1 December 2021
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 28
Impact of thermophoretic particle deposition on Glauert wall jet slip flow of nanofluid
- 1 December 2021
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 28
Open AccessImpact of thermophoretic particle deposition on Glauert wall jet slip flow of nanofluid
- 25 May 2021
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 57 (12) , 1997-2013
Nusselt number and friction factor correlations for the solar air heater duct furnished with artificial cube shaped roughness elements on the absorber plate
- 25 May 2021
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 57 (12) , 1997-2013
Nusselt number and friction factor correlations for the solar air heater duct furnished with artificial cube shaped roughness elements on the absorber plate
- 22 August 2019
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 33 (4) , 374-387
Optimum thermo-hydraulic performance of solar air heater provided with cubical roughness on the absorber surface
Heat transfer augmentation in solar air heaters (SAHs) can be achieved economically and conveniently using artificial roughness elements on the absorber surface. Cubical roughness elements used in this investigation produces better heat transfer characteristics. However, this enhancement is particularly accompanied by increased pumping power due to increased friction. This study presents the results of the experiments carried out to determine the optimum design and operating conditions which gives a better thermohydraulic performance. Efficiency index ( ) is often used as thermohydraulic performance parameter which is evaluated using correlation = (( )/( )). Experiments are conducted within the limits of Reynolds number ( ) from 3000 to 8000, relative roughness pitch ( ) of 10 to 20 and relative roughness gap ( ) of 4 to 8. Relative roughness height ( ) of 0.06 and aspect ratio ( ) of 5 is maintained constants. Substantial enhancement in the Nusselt number (59.1–72.7%) accompanied by a large increase in the friction factor (138.7–179.4%) over SAH with smooth absorber plate is achieved. Optimum thermohydraulic performance is obtained for lower values of the Reynolds number, relative roughness pitch ( ) value 20 and relative roughness gap ( ) of 8.- 22 August 2019
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 33 (4) , 374-387
Optimum thermo-hydraulic performance of solar air heater provided with cubical roughness on the absorber surface
Heat transfer augmentation in solar air heaters (SAHs) can be achieved economically and conveniently using artificial roughness elements on the absorber surface. Cubical roughness elements used in this investigation produces better heat transfer characteristics. However, this enhancement is particularly accompanied by increased pumping power due to increased friction. This study presents the results of the experiments carried out to determine the optimum design and operating conditions which gives a better thermohydraulic performance. Efficiency index ( ) is often used as thermohydraulic performance parameter which is evaluated using correlation = (( )/( )). Experiments are conducted within the limits of Reynolds number ( ) from 3000 to 8000, relative roughness pitch ( ) of 10 to 20 and relative roughness gap ( ) of 4 to 8. Relative roughness height ( ) of 0.06 and aspect ratio ( ) of 5 is maintained constants. Substantial enhancement in the Nusselt number (59.1–72.7%) accompanied by a large increase in the friction factor (138.7–179.4%) over SAH with smooth absorber plate is achieved. Optimum thermohydraulic performance is obtained for lower values of the Reynolds number, relative roughness pitch ( ) value 20 and relative roughness gap ( ) of 8.