Hui Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hui Lin has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ravishankar K. Iyer
University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
2 shared publications Bibek Shrestha
Computer Science and Engineering, University of Nevada, Reno, Nevada United States
1 shared publication- Dong Jin
University of Arkansas
1 shared publication Homa Alemzadeh
Electrical and Computer Engeering, University of Virginia, Charlottesville, Virginia United States
1 shared publication- Sayeb Mohammad Tadvin
University of Rhode Island, USA
1 shared publication Zbigniew Kalbarczyk
Coordinated Science Laboratory, University of Illinois at Urbana–Champaign, Urbana, Illinois United States
1 shared publication
Latest Publications
- Open Access
- 21 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 138-143
HELICSAuto: Automating the Development of Cyber-Physical Co-Simulation Framework for Smart Grids
Co-simulation is a powerful technique integrating various simulation tools to create a unified simulation environment. It provides an in-depth understanding of the interplay between cyber and physical infrastructures in industrial control systems like smart grids. HELICS is a framework that facilitates co-simulation development by providing common interfaces to enhance simulators, synchronize their executions, and exchange information. In this paper, we propose HELICSAuto, a code instrumentation procedure that automates the integration of domain-specific simulators with HELICS APIs. HELICSAuto requires developers to label their source codes using a pre-defined syntax, after which an interpreter automatically instruments the code with minimal manual involvement. We demonstrate the effectiveness of HELICSAuto by successfully applying it to simulators based on PandaPower, PowerWorld, OPAL-RT, and PyDNP3 to create a transmission-distribution-communication co-simulation environment for complex smart grids.
- 21 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 138-143
Open AccessHELICSAuto: Automating the Development of Cyber-Physical Co-Simulation Framework for Smart Grids
Co-simulation is a powerful technique integrating various simulation tools to create a unified simulation environment. It provides an in-depth understanding of the interplay between cyber and physical infrastructures in industrial control systems like smart grids. HELICS is a framework that facilitates co-simulation development by providing common interfaces to enhance simulators, synchronize their executions, and exchange information. In this paper, we propose HELICSAuto, a code instrumentation procedure that automates the integration of domain-specific simulators with HELICS APIs. HELICSAuto requires developers to label their source codes using a pre-defined syntax, after which an interpreter automatically instruments the code with minimal manual involvement. We demonstrate the effectiveness of HELICSAuto by successfully applying it to simulators based on PandaPower, PowerWorld, OPAL-RT, and PyDNP3 to create a transmission-distribution-communication co-simulation environment for complex smart grids.
- 7 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Computer
- Vol. 53 (5) , 35-43
Data-Centric Edge Computing to Defend Power Grids Against IoT-Based Attacks
The Internet of Things (IoT) introduces new attack surfaces to power grids through Wi-Fi-enabled high-wattage appliances, rendering security mechanisms ineffective. We propose a data-centric edge-computing infrastructure to host defend mechanisms in IoT clouds by integrating physical states in decentralized power-grid regions.
- 7 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Computer
- Vol. 53 (5) , 35-43
Data-Centric Edge Computing to Defend Power Grids Against IoT-Based Attacks
The Internet of Things (IoT) introduces new attack surfaces to power grids through Wi-Fi-enabled high-wattage appliances, rendering security mechanisms ineffective. We propose a data-centric edge-computing infrastructure to host defend mechanisms in IoT clouds by integrating physical states in decentralized power-grid regions.
- 12 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Computer
- Vol. 53 (3) , 26-37
Challenges and Opportunities in the Detection of Safety-Critical Cyberphysical Attacks
Cyberphysical systems (CPSs) are increasingly used in various application domains and face the threat of cyberphysical attacks. In this article, we discuss challenges in detecting these attacks. We use power grids and surgical robots to clarify our analysis, and we use this analysis to identify ongoing challenges and future research directions.
- 12 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Computer
- Vol. 53 (3) , 26-37
Challenges and Opportunities in the Detection of Safety-Critical Cyberphysical Attacks
Cyberphysical systems (CPSs) are increasingly used in various application domains and face the threat of cyberphysical attacks. In this article, we discuss challenges in detecting these attacks. We use power grids and surgical robots to clarify our analysis, and we use this analysis to identify ongoing challenges and future research directions.
- 14 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 10 (5) , 4893-4906
RAINCOAT: Randomization of Network Communication in Power Grid Cyber Infrastructure to Mislead Attackers
Though attackers aim to introduce different physical perturbations on power grids, they need to rely on periodic data acquisitions performed by control centers to estimate the physical state of the grid and thus to prepare for destructive activities. In this paper, we present Raincoat, which randomizes data acquisitions to disrupt and mislead attackers’ preparations. We transform one data acquisition into multiple rounds. In each round, we dynamically manipulate network flows in the control networks so that randomly selected “online” devices respond with real measurements. Meanwhile, we intelligently spoof measurements for other “offline” devices to mislead attackers into designing ineffective strategies. Based on experiments using large-scale power systems and six real wide area networks, Raincoat is effective against false data injection and control-related attacks with small overhead. The probability of successful attacks can be reduced from 70% to 1%; attacks introduce little damage even if they are executed. Network latency of data acquisition increases on average by less than 6%.
- 14 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 10 (5) , 4893-4906
RAINCOAT: Randomization of Network Communication in Power Grid Cyber Infrastructure to Mislead Attackers
Though attackers aim to introduce different physical perturbations on power grids, they need to rely on periodic data acquisitions performed by control centers to estimate the physical state of the grid and thus to prepare for destructive activities. In this paper, we present Raincoat, which randomizes data acquisitions to disrupt and mislead attackers’ preparations. We transform one data acquisition into multiple rounds. In each round, we dynamically manipulate network flows in the control networks so that randomly selected “online” devices respond with real measurements. Meanwhile, we intelligently spoof measurements for other “offline” devices to mislead attackers into designing ineffective strategies. Based on experiments using large-scale power systems and six real wide area networks, Raincoat is effective against false data injection and control-related attacks with small overhead. The probability of successful attacks can be reduced from 70% to 1%; attacks introduce little damage even if they are executed. Network latency of data acquisition increases on average by less than 6%.