Madina Jelbuldina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Madina Jelbuldina has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Sanzhar Korganbayev
Laboratory of Biosensors and Bioinstruments, National Laboratory Astana, Nur-Sultan, Kazakhstan
5 shared publications- Daniele Tosi
National Laboratory astana, Laboratory of Biosensors and Bioinstruments, astana, Kazakhstan
4 shared publications - Vassilis J. Inglezakis
Department of Chemical & Process Engineering, University of Strathclyde, Glasgow G1 1XJ, UK
4 shared publications - Amal Al Ghaferi
Masdar Institute
3 shared publications - Hammad Younes
Department of Electrical Engineering, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA
3 shared publications Irfan Saadat
3 shared publications
Latest Publications
- Open Access
Distributed Sensing Network Enabled by High-Scattering MgO-Doped Optical Fibers for 3D Temperature Monitoring of Thermal Ablation in Liver Phantom
Thermal ablation is achieved by delivering heat directly to tissue through a minimally invasive applicator. The therapy requires a temperature control between 50–100 °C since the mortality of the tumor is directly connected with the thermal dosimetry. Existing temperature monitoring techniques have limitations such as single-point monitoring, require costly equipment, and expose patients to X-ray radiation. Therefore, it is important to explore an alternative sensing solution, which can accurately monitor temperature over the whole ablated region. The work aims to propose a distributed fiber optic sensor as a potential candidate for this application due to the small size, high resolution, bio-compatibility, and temperature sensitivity of the optical fibers. The working principle is based on spatial multiplexing of optical fibers to achieve 3D temperature monitoring. The multiplexing is achieved by high-scattering, nanoparticle-doped fibers as sensing fibers, which are spatially separated by lower-scattering level of single-mode fibers. The setup, consisting of twelve sensing fibers, monitors tissue of 16 mm × 16 mm × 25 mm in size exposed to a gold nanoparticle-mediated microwave ablation. The results provide real-time 3D thermal maps of the whole ablated region with a high resolution. The setup allows for identification of the asymmetry in the temperature distribution over the tissue and adjustment of the applicator to follow the allowed temperature limits.
Open AccessDistributed Sensing Network Enabled by High-Scattering MgO-Doped Optical Fibers for 3D Temperature Monitoring of Thermal Ablation in Liver Phantom
Thermal ablation is achieved by delivering heat directly to tissue through a minimally invasive applicator. The therapy requires a temperature control between 50–100 °C since the mortality of the tumor is directly connected with the thermal dosimetry. Existing temperature monitoring techniques have limitations such as single-point monitoring, require costly equipment, and expose patients to X-ray radiation. Therefore, it is important to explore an alternative sensing solution, which can accurately monitor temperature over the whole ablated region. The work aims to propose a distributed fiber optic sensor as a potential candidate for this application due to the small size, high resolution, bio-compatibility, and temperature sensitivity of the optical fibers. The working principle is based on spatial multiplexing of optical fibers to achieve 3D temperature monitoring. The multiplexing is achieved by high-scattering, nanoparticle-doped fibers as sensing fibers, which are spatially separated by lower-scattering level of single-mode fibers. The setup, consisting of twelve sensing fibers, monitors tissue of 16 mm × 16 mm × 25 mm in size exposed to a gold nanoparticle-mediated microwave ablation. The results provide real-time 3D thermal maps of the whole ablated region with a high resolution. The setup allows for identification of the asymmetry in the temperature distribution over the tissue and adjustment of the applicator to follow the allowed temperature limits.
- 2 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 3 (8) , 1-4
Fiber Bragg Grating Sensor for Temperature Monitoring During HIFU Ablation of Ex Vivo Breast Fibroadenoma
In this work, we report a fiber Bragg grating (FBG) sensing system for a real-time temperature monitoring during a high-intensity focused ultrasound (HIFU) treatment of breast fibroadenoma. Temperature monitoring of the HIFU procedure within the treated area contributes to a successful outcome of a thermal ablation procedure by providing a valid feedback to the clinician. The unique characteristics of the FBG sensors make them a valid alternative to traditional sensing techniques for a variety of biomedical applications, including thermotherapies. The experiments were conducted on ex vivo breast fibroadenoma tissues. Results confirm that proposed setup is able to perform multipoint temperature measurements and to distinguish between consecutive ultrasound pulses.
- 2 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 3 (8) , 1-4
Fiber Bragg Grating Sensor for Temperature Monitoring During HIFU Ablation of Ex Vivo Breast Fibroadenoma
In this work, we report a fiber Bragg grating (FBG) sensing system for a real-time temperature monitoring during a high-intensity focused ultrasound (HIFU) treatment of breast fibroadenoma. Temperature monitoring of the HIFU procedure within the treated area contributes to a successful outcome of a thermal ablation procedure by providing a valid feedback to the clinician. The unique characteristics of the FBG sensors make them a valid alternative to traditional sensing techniques for a variety of biomedical applications, including thermotherapies. The experiments were conducted on ex vivo breast fibroadenoma tissues. Results confirm that proposed setup is able to perform multipoint temperature measurements and to distinguish between consecutive ultrasound pulses.
- 16 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (19) , 8005-8011
Real-Time Temperature Monitoring in Liver During Magnetite Nanoparticle-Enhanced Microwave Ablation With Fiber Bragg Grating Sensors: Ex Vivo Analysis
In this paper, we present the design and experiments of a fiber Bragg grating (FBG) sensing network for nanoparticle-enhanced microwave ablation (MWA). MWA is an emerging minimally invasive treatment for cancer care, making use of a miniaturized applicator; it is possible to deliver a cytotoxic thermal treatment in situ with high spatial confinement. Cells' death is nearly instantaneous at 60 °C. The use of magnetite nanoparticles enhances the amount of ablated tissue, and reshapes the thermal distribution during the treatment. In order to measure the thermal maps (temperature as a function of space and time) instantaneously and in situ, a set of three arrays of five FBG sensors has been designed, mapping the thermal distribution of the tissue and estimating the ablated tissue in real time. Experiments carried out with different nanoparticle densities show that the extension of the ablated region is the highest for a density of 5 mg/mL. The results are displayed in the form of thermal maps, over the ablation plane.
- 16 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (19) , 8005-8011
Real-Time Temperature Monitoring in Liver During Magnetite Nanoparticle-Enhanced Microwave Ablation With Fiber Bragg Grating Sensors: Ex Vivo Analysis
In this paper, we present the design and experiments of a fiber Bragg grating (FBG) sensing network for nanoparticle-enhanced microwave ablation (MWA). MWA is an emerging minimally invasive treatment for cancer care, making use of a miniaturized applicator; it is possible to deliver a cytotoxic thermal treatment in situ with high spatial confinement. Cells' death is nearly instantaneous at 60 °C. The use of magnetite nanoparticles enhances the amount of ablated tissue, and reshapes the thermal distribution during the treatment. In order to measure the thermal maps (temperature as a function of space and time) instantaneously and in situ, a set of three arrays of five FBG sensors has been designed, mapping the thermal distribution of the tissue and estimating the ablated tissue in real time. Experiments carried out with different nanoparticle densities show that the extension of the ablated region is the highest for a density of 5 mg/mL. The results are displayed in the form of thermal maps, over the ablation plane.
- 7 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 36 (20) , 4723-4729
Thermal Profile Detection Through High-Sensitivity Fiber Optic Chirped Bragg Grating on Microstructured PMMA Fiber
In this paper, a linearly chirped fiber Bragg grating (CFBG) inscribed in a microstructured polymer optical fiber (mPOF) has been demonstrated for detecting temperature profiles during thermal treatments. A CFBG of 10-mm length and 0.98-nm bandwidth has been inscribed in an mPOF fiber by means of a KrF laser and uniform phase mask. The CFBG has a high temperature sensitivity of -191.4 pm/°C. The CFBG has been used as a semi-distributed temperature sensor, capable of detecting the temperature profile along the grating length, for scenarios that account minimally invasive biomedical treatments. Two experiments have been designed to validate the CFBG temperature reconstruction, using a linear gradient, and a research-grade radiofrequency ablation setup to apply Gaussian-shaped temperature spatial profiles. The result is that the higher sensitivity of the CFBG supports the detection of spatially nonuniform temperature fields by means of spectral reconstruction.
- 7 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 36 (20) , 4723-4729
Thermal Profile Detection Through High-Sensitivity Fiber Optic Chirped Bragg Grating on Microstructured PMMA Fiber
In this paper, a linearly chirped fiber Bragg grating (CFBG) inscribed in a microstructured polymer optical fiber (mPOF) has been demonstrated for detecting temperature profiles during thermal treatments. A CFBG of 10-mm length and 0.98-nm bandwidth has been inscribed in an mPOF fiber by means of a KrF laser and uniform phase mask. The CFBG has a high temperature sensitivity of -191.4 pm/°C. The CFBG has been used as a semi-distributed temperature sensor, capable of detecting the temperature profile along the grating length, for scenarios that account minimally invasive biomedical treatments. Two experiments have been designed to validate the CFBG temperature reconstruction, using a linear gradient, and a research-grade radiofrequency ablation setup to apply Gaussian-shaped temperature spatial profiles. The result is that the higher sensitivity of the CFBG supports the detection of spatially nonuniform temperature fields by means of spectral reconstruction.
- 1 July 2018
- Published by Elsevier in Optical Fiber Technology
- Vol. 43, 145-152
Fiber Bragg grating based temperature profiling in ferromagnetic nanoparticles-enhanced radiofrequency ablation
- 1 July 2018
- Published by Elsevier in Optical Fiber Technology
- Vol. 43, 145-152
Fiber Bragg grating based temperature profiling in ferromagnetic nanoparticles-enhanced radiofrequency ablation
- 1 January 2018
- Published by Optica Publishing Group
- p. WF3
Fiber Bragg Grating Sensors for Temperature Monitoring during Nanoparticle-assisted Microwave Ablation
We report a fiber Bragg grating (FBG) based sensing system for the real-time temperature profiling during a ferromagnetic nanoparticles (NPs)-enhanced microwave ablation. The obtained thermal maps show that injection of NPs solution helps enlarge the ablation lesion by about 20% compared to a standard MWA.
- 1 January 2018
- Published by Optica Publishing Group
- p. WF3
Fiber Bragg Grating Sensors for Temperature Monitoring during Nanoparticle-assisted Microwave Ablation
We report a fiber Bragg grating (FBG) based sensing system for the real-time temperature profiling during a ferromagnetic nanoparticles (NPs)-enhanced microwave ablation. The obtained thermal maps show that injection of NPs solution helps enlarge the ablation lesion by about 20% compared to a standard MWA.
- 1 August 2017
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 263, 349-356
Fabrication and design of CNTs inkjet-printed based micro FET sensor for sodium chloride scale detection in oil field
- 1 August 2017
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 263, 349-356
Fabrication and design of CNTs inkjet-printed based micro FET sensor for sodium chloride scale detection in oil field
- 1 January 2017
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 17 (1) , 405-412
Carbon Nanotube Inkjet Printing Based Resettable Sensor for Online Scale Monitoring
In this paper, a new type of sensor and associated system for complete online monitoring of scale deposition with great accuracy and reliability is fabricated and characterized. The system is based on carbon nanotubes (CNTs), which have unique sensing/electronic properties along with physical and chemical stability in corrosive and hostile environments required for the oil and gas application. CNTs inkjet printing technique is used to fabricate the CNTs sensor. The sensitivity of the films, real time monitoring of brine solution, stability of the films in various solvents and fluids and the ability of setting and resetting of the sensor are studied. The results of these studies indicate that adding of one brine solution on the surface of the CNTs inkjet printing increases the resistance from 0.50 kΩ to 1.50 kΩ. The CNTs inkjet printing sample is found to be stable even after 48 hours of soaking the whole sample in DI-water. This sensor not only shows good sensing response for detection of the deposition of brine, but can also be easily reset back many times by just wash it with DI-water. This simple sensor is ideally suited for real time monitoring and the response time of the film is found to be from 15–30 s.
- 1 January 2017
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 17 (1) , 405-412
Carbon Nanotube Inkjet Printing Based Resettable Sensor for Online Scale Monitoring
In this paper, a new type of sensor and associated system for complete online monitoring of scale deposition with great accuracy and reliability is fabricated and characterized. The system is based on carbon nanotubes (CNTs), which have unique sensing/electronic properties along with physical and chemical stability in corrosive and hostile environments required for the oil and gas application. CNTs inkjet printing technique is used to fabricate the CNTs sensor. The sensitivity of the films, real time monitoring of brine solution, stability of the films in various solvents and fluids and the ability of setting and resetting of the sensor are studied. The results of these studies indicate that adding of one brine solution on the surface of the CNTs inkjet printing increases the resistance from 0.50 kΩ to 1.50 kΩ. The CNTs inkjet printing sample is found to be stable even after 48 hours of soaking the whole sample in DI-water. This sensor not only shows good sensing response for detection of the deposition of brine, but can also be easily reset back many times by just wash it with DI-water. This simple sensor is ideally suited for real time monitoring and the response time of the film is found to be from 15–30 s.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 289-292
Carbon nanomaterials based TSVs for dual sensing and vertical interconnect application
We discuss fabrication and characterization of TSVs filled with carbon nano-materials (CNM) for dual function of sensing and vertical interconnect for hostile environment applications (Corrosive High Temperature and Pressure). Nano-composites, made by functionalization of CNTs were integrated using dispersion in epoxy resin and inkjet techniques to fill up the TSVs and provide sensing surface. The results reveal ability for the nano-composite to fill vias with electrical conductivity path and sensing established through the wafer backside.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 289-292
Carbon nanomaterials based TSVs for dual sensing and vertical interconnect application
We discuss fabrication and characterization of TSVs filled with carbon nano-materials (CNM) for dual function of sensing and vertical interconnect for hostile environment applications (Corrosive High Temperature and Pressure). Nano-composites, made by functionalization of CNTs were integrated using dispersion in epoxy resin and inkjet techniques to fill up the TSVs and provide sensing surface. The results reveal ability for the nano-composite to fill vias with electrical conductivity path and sensing established through the wafer backside.